S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd

ShenZhen Zhouji Hengtong technology Co.,Ltd Smartphone

Page 1 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 2 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 3 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 4 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 5 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 6 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 7 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 8 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 9 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 10 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 11 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 12 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 13 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 14 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 15 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Page 16 of S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd

Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Report No: CCISE171108905
Cover Page
FCC REPORT
Applicant:
ShenZhen Zhouji Hengtong technology Co., Ltd
Address of Applicant:
A Floor 3, Bld A2, Enet Digital Industries Park, NO.22, Dafu
Industries Area, Aobei Community, Longhua New District,
Shenzhen, China
Equipment Under Test (EUT)
Product Name:
Smartphone
Model No.:
S16
Trade mark:
HOMTOM
FCC ID:
2AH8Q-S16
Applicable standards:
FCC CFR Title 47 Part 15 Subpart B
Date of sample receipt:
30 Nov., 2017
Date of Test:
30 Nov., to 14 Dec., 2017
Date of report issued:
15 Dec., 2017
Test Result:
Pass *
* In the configuration tested, the EUT complied with the standards specified above.
Authorized Signature:
Bruce Zhang
Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.
Report No: CCISE171108905
Version
Version No.
Date
Description
00
15 Dec., 2017
Original
Tested by:
Date:
15 Dec., 2017
Date:
15 Dec., 2017
Test Engineer
Reviewed by:
Project Engineer
Contents
Page
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 2 of 18
Report No: CCISE171108905
COVER PAGE ....................................................................................................................................................... 1
VERSION ............................................................................................................................................................... 2
CONTENTS ........................................................................................................................................................... 2
TEST SUMMARY .................................................................................................................................................. 4
GENERAL INFORMATION .................................................................................................................................. 5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
CLIENT INFORMATION ...................................................................................................................................................... 5
GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
TEST MODE.................................................................................................................................................................... 5
MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
LABORATORY FACILITY ...................................................................................................................................................... 6
LABORATORY LOCATION ................................................................................................................................................... 6
TEST INSTRUMENTS LIST.................................................................................................................................................... 7
TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
6.1
6.2
CONDUCTED EMISSION ..................................................................................................................................................... 8
RADIATED EMISSION ...................................................................................................................................................... 11
TEST SETUP PHOTO ........................................................................................................................................ 17
EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 3 of 18
Report No: CCISE171108905
Test Summary
Test Item
Section in CFR 47
Result
Conducted Emission
Part 15.107
Pass
Radiated Emission
Part 15.109
Pass
Pass: The EUT complies with the essential requirements in the standard.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 4 of 18
Report No: CCISE171108905
General Information
5.1 Client Information
Applicant:
ShenZhen Zhouji Hengtong technology Co., Ltd
Address:
A Floor 3, Bld A2, Enet Digital Industries Park, NO.22, Dafu
Industries Area, Aobei Community, Longhua New District, Shenzhen,
China
Manufacturer:
ShenZhen Zhouji Hengtong technology Co., Ltd
Address:
A Floor 3, Bld A2, Enet Digital Industries Park, NO.22, Dafu
Industries Area, Aobei Community, Longhua New District, Shenzhen,
China
5.2 General Description of E.U.T.
Product Name:
Smartphone
Model No.:
S16
Power supply:
Rechargeable Li-ion Battery DC3.8V-3000mAh
AC adapter with two plugs :
Model: HJ-0501000B2-US
Input: AC100-240V, 50/60Hz, 0.15A
Output: DC 5.0V, 1000mA
5.3 Test Mode
Operating mode
PC mode
Charging+Recording mode
Charging+Playing mode
FM mode
Detail description
Keep the EUT in Downloading mode(Worst case)
Keep the EUT in Charging+Recording mode
Keep the EUT in Charging+Playing mode
Keep the EUT in FM receiver mode
GPS mode
Keep the EUT in GPS receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying
antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown
in Test Results of the following pages.
5.4 Measurement Uncertainty
Items
Conducted Emission (9kHz ~ 30MHz)
Radiated Emission (9kHz ~ 30MHz)
Radiated Emission (30MHz ~ 1000MHz)
Radiated Emission (1GHz ~ 18GHz)
Radiated Emission (18GHz ~ 26.5GHz)
Expanded Uncertainty (Confidence of 95%)
2.14 dB (k=2)
4.24 dB (k=2)
4.35 dB (k=2)
4.44 dB (k=2)
4.56 dB (k=2)
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 5 of 18
Report No: CCISE171108905
5.5 Description of Support Units
Manufacturer
Description
Model
Serial Number
FCC ID/DoC
DELL
PC
OPTIPLEX745
N/A
DoC
DELL
MONITOR
E178FPC
N/A
DoC
DELL
KEYBOARD
SK-8115
N/A
DoC
DELL
MOUSE
MOC5UO
N/A
DoC
HP
Printer
CB495A
05257893
DoC
5.6 Related Submittal(s) / Grant (s)
This is an original grant, no related submittals and grants.
5.7 Laboratory Facility
The test facility is recognized, certified, or accredited by the following organizations:
 FCC - Registration No.: 727551
Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
(Federal Communications Commission). The Registration No. is 727551.
 IC - Registration No.: 10106A-1
The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
with Registration No.: 10106A-1.
 CNAS - Registration No.: CNAS L6048
Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
Requirements for the Competence of Testing and Calibration laboratories for the competence of
testing. The Registration No. is CNAS L6048.
 A2LA - Registration No.: 4346.01
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
17025:2005 General requirements for the competence of testing and calibration laboratories. The test
scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf
5.8 Laboratory Location
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Tel: +86-755-23118282, Fax: +86-755-23116366
Email: info@ccis-cb.com, Website: http://www.ccis-cb.com
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 6 of 18
Report No: CCISE171108905
5.9 Test Instruments list
Radiated Emission:
Item
10
Test Equipment
3m SAC
BiConiLog Antenna
Horn Antenna
Pre-amplifier
(10kHz-1.3GHz)
Pre-amplifier
(1GHz-18GHz)
Spectrum analyzer
9k-30GHz
EMI Test Receiver
EMI Test Software
Coaxial Cable
Coaxial Cable
SAEMC
SCHWARZBECK
SCHWARZBECK
9(L)*6(W)* 6(H)
VULB9163
BBHA9120D
Inventory
No.
CCIS0001
CCIS0005
CCIS0006
HP
8447D
CCIS0003
02-25-2017
02-24-2018
Compliance Direction
Systems Inc.
PAP-1G18
CCIS0011
02-25-2017
02-24-2018
Rohde & Schwarz
FSP30
CCIS0023
02-25-2017
02-24-2018
Rohde & Schwarz
AUDIX
N/A
N/A
ESRP7
E3
N/A
N/A
CCIS0167
N/A
CCIS0018
CCIS0020
02-25-2017
N/A
02-25-2017
02-25-2017
02-24-2018
N/A
02-24-2018
02-24-2018
Inventory
No.
CCIS0061
CCIS0002
CCIS0074
CCIS0086
N/A
Cal.Date
(mm-dd-yy)
07-22-2017
02-25-2017
02-25-2017
02-25-2017
N/A
Cal.Due date
(mm-dd-yy)
07-21-2020
02-24-2018
02-24-2018
02-24-2018
N/A
Manufacturer
Model No.
Cal. Date
(mm-dd-yy)
07-22-2017
02-25-2017
02-25-2017
Cal. Due date
(mm-dd-yy)
07-21-2020
02-24-2018
02-24-2018
Conducted Emission:
Item
Test Equipment
Shielding Room
EMI Test Receiver
LISN
Coaxial Cable
EMI Test Software
Manufacturer
ZhongShuo Electron
Rohde & Schwarz
CHASE
CCIS
AUDIX
Model No.
11.0(L)x4.0(W)x3.0(H)
ESCI
MN2050D
N/A
E3
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 7 of 18
Report No: CCISE171108905
Test results and Measurement Data
6.1 Conducted Emission
Test Requirement:
FCC Part 15 B Section 15.107
Test Method:
ANSI C63.4:2014
Test Frequency Range:
150kHz to 30MHz
Class / Severity:
Class B
Receiver setup:
RBW=9kHz, VBW=30kHz
Limit:
Limit (dBµV)
Quasi-peak
Average
0.15-0.5
66 to 56*
56 to 46*
0.5-5
56
46
0.5-30
60
50
* Decreases with the logarithm of the frequency.
Class B
Frequency range (MHz)
Test setup:
Test procedure
1. The E.U.T and simulators are connected to the main power through a
line impedance stabilization network(L.I.S.N.). The provide a
50ohm/50uH coupling impedance for the measuring equipment.
2. The peripheral devices are also connected to the main power through
a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
termination. (Please refers to the block diagram of the test setup and
photographs).
3. Both sides of A.C. line are checked for maximum conducted
interference. In order to find the maximum emission, the relative
positions of equipment and all of the interface cables must be changed
according to ANSI C63.4: 2014 on conducted measurement.
Test environment:
Temp.:
Test Instruments:
Refer to section 5.9 for details
Test mode:
Refer to section 5.3 for details
Test results:
Pass
23 C
Humid.:
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
56%
Press.:
101kPa
Project No.: CCISE1711089
Page 8 of 18
Report No: CCISE171108905
Measurement data:
Test Polarization: Line
Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 9 of 18
Report No: CCISE171108905
Test Polarization: Neutral
Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 10 of 18
Report No: CCISE171108905
6.2 Radiated Emission
Test Requirement:
FCC Part 15 B Section 15.109
Test Method:
ANSI C63.4:2014
Test Frequency Range:
30MHz to 6000MHz
Test site:
Limit:
Measurement Distance: 3m (Semi-Anechoic Chamber)
Frequency
Detector
RBW
VBW
Remark
30MHz-1GHz
Quasi-peak
120kHz
300kHz
Quasi-peak Value
Peak
1MHz
3MHz
Peak Value
Above 1GHz
RMS
1MHz
3MHz
Average Value
Frequency
Limit (dBuV/m @3m)
Remark
30MHz-88MHz
40.0
Quasi-peak Value
88MHz-216MHz
43.5
Quasi-peak Value
216MHz-960MHz
46.0
Quasi-peak Value
960MHz-1GHz
54.0
Quasi-peak Value
54.0
Average Value
Above 1GHz
74.0
Peak Value
Test setup:
Below 1GHz
Receiver setup:
Above 1GHz
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 11 of 18
Report No: CCISE171108905
Test Procedure:
1. The EUT was placed on the top of a rotating table 0.8 meters above the
ground at a 3 meter semi-anechoic camber. The table was rotated 360
degrees to determine the position of the highest radiation.
2. The EUT was set 3 meters away from the interference-receiving
antenna, which was mounted on the top of a variable-height antenna
tower.
3. The antenna height is varied from one meter to four meters above the
ground to determine the maximum value of the field strength. Both
horizontal and vertical polarizations of the antenna are set to make the
measurement.
4. For each suspected emission, the EUT was arranged to its worst case
and then the antenna was tuned to heights from 1 meter to 4 meters
and the rotatable table was turned from 0 degrees to 360 degrees to
find the maximum reading.
5. The test-receiver system was set to Peak Detect Function and Specified
Bandwidth with Maximum Hold Mode.
6. If the emission level of the EUT in peak mode was 10dB lower than the
limit specified, then testing could be stopped and the peak values of the
EUT would be reported. Otherwise the emissions that did not have 10dB
margin would be re-tested one by one using peak, quasi-peak or
average method as specified and then reported in a data sheet.
Test environment:
Temp.:
Test Instruments:
Refer to section 5.9 for details
Test mode:
Refer to section 5.3 for details
Test results:
Passed
Remark:
All of the observed value above 6GHz ware the niose floor , which were no
recorded
25 C
Humid.:
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
55%
Press.:
1 01kPa
Project No.: CCISE1711089
Page 12 of 18
Report No: CCISE171108905
Measurement Data:
Below 1GHz
Test Polarization: Horizontal
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 13 of 18
Report No: CCISE171108905
Test Polarization: Vertical
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 14 of 18
Report No: CCISE171108905
Above 1GHz
Test Polarization: Horizontal
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 15 of 18
Report No: CCISE171108905
Test Polarization: Vertical
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1711089
Page 16 of 18
Download: S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Mirror Download [FCC.gov]S16 Smartphone Test Report HD 271 S1 ShenZhen Zhouji Hengtong technology Co.,Ltd
Document ID3708188
Application IDd/ltU1YZuBVwtpDyUlSFjw==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize133.39kB (1667328 bits)
Date Submitted2018-01-10 00:00:00
Date Available2018-01-10 00:00:00
Creation Date2017-12-20 17:52:51
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2017-12-20 17:53:20
Document TitleHD 271 S1
Document CreatorMicrosoft® Word 2010
Document Author: LAB02

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : LAB02
Create Date                     : 2017:12:20 17:52:51+08:00
Modify Date                     : 2017:12:20 17:53:20+08:00
Language                        : zh-CN
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : LAB02
Title                           : HD 271 S1
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2017:12:20 17:53:20+08:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:a8deb39d-c91b-4f7a-b195-2937c861074d
Instance ID                     : uuid:cf3b8330-ad73-48bf-ae1c-8fee693549c6
Page Count                      : 16