OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.

Aiut sp. z o.o. Mobile Data Gateway

FCC ID Filing: 2AKQSOKO5875
Purchase on Amazon: Mobile Data Gateway

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 2 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 3 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 4 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 5 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 6 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 7 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 8 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 9 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 10 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 11 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 12 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 13 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 14 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 15 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 16 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 17 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 18 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 19 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 20 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Page 21 of OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.

AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
FCC LISTED, REGISTRATION
NUMBER: 720267
Informe de ensayo nº:
Test report No:
IC LISTED REGISTRATION
NUMBER IC 4621A-2
NIE: 51934RRF.002
Test report
USA FCC Part 15.249 & 15.209
CANADA RSS-210, RSS-Gen
Radio Frequency Devices. Operation within the bands 902 - 928 MHz, 2400 -2483.5 MHz,
5725 - 5875 MHz, and 24.0 – 24.25 GHz.
Identificación del objeto ensayado...................... Mobile
Identification of item tested
Marca ................................................................... imr
Data Gateway
/ AIUT
Trade
Modelo y/o referencia tipo .................................. OKO
5875
Model and /or type reference
Other identification of the product .................... FCC
ID: 2AKQSOKO5875
IC: 22378-OKO5875
Final HW version ................................................ 3
Final SW version ................................................. C1
Características ..................................................... Not
Features
provided data
Fabricante ............................................................ AIUT
Manufacturer
SP. Z O.O.
ul. Wyczólkowskiego 113, 44-109 Gliwice, Poland.
Método de ensayo solicitado, norma................... USA FCC Part 15.249 10-1-15 Edition: Operation within the bands 902
Test method requested, standard
- 928 MHz, 2400 -2483.5 MHz, 5725 - 5875 MHz, and 24.0 – 24.25
GHz.
USA FCC Part 15.209 10-1-15 Edition: Radiated emission limits;
general requirements.
CANADA RSS-210 Issue 9 (August 2016).
CANADA RSS-Gen Issue 4 (November 2014).
ANSI C63.10-2013: American National Standard for Testing Unlicensed
Wireless Devices.
Resultado .............................................................. IN
COMPLIANCE
Summary
Aprobado por (nombre / cargo y firma) ........... A.
Approved by (name / position & signature)
Llamas
RF Lab. Manager
Fecha de realización ........................................... 2017-03-03
Firmado digitalmente
por ALEJANDRO
LLAMAS RODRIGUEZ
Fecha: 2017.03.03
13:00:34 +01'00'
Date of issue
Formato de informe No. ...................................... FDT08_18
Report template No
Report No: (NIE)
51934RRF.002
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Index
Competences and guarantees .........................................................................................................................3
General conditions .........................................................................................................................................3
Uncertainty ....................................................................................................................................................3
Usage of samples ...........................................................................................................................................3
Test sample description .................................................................................................................................4
Identification of the client .............................................................................................................................4
Testing period ................................................................................................................................................4
Environmental conditions..............................................................................................................................4
Remarks and comments .................................................................................................................................5
Testing verdicts .............................................................................................................................................6
Appendix A – Test result “Proprietary radio” ...............................................................................................7
Report No: (NIE)
51934RRF.002
Page 2 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Competences and guarantees
AT4 wireless is a testing laboratory accredited by the National Accreditation Body (ENAC -Entidad Nacional de
Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
AT4 wireless is a laboratory with a measurement facility in compliance with the requirements of Section 2.948 of the
FCC rules and has been added to the list of facilities whose measurements data will be accepted in conjuction with
applications for Certification under Parts 15 or 18 of the Commission's Rules. Registration Number: 720267.
AT4 wireless is a laboratory with a measurement site in compliance with the requirements of RSS 212, Issue 1
(Provisional) and has been added to the list of filed sites of the Canadian Certification and Engineering Bureau.
Reference File Number: IC 4621A-2.
In order to assure the traceability to other national and international laboratories, AT4 wireless has a calibration and
maintenance program for its measurement equipment.
AT4 wireless guarantees the reliability of the data presented in this report, which is the result of the measurements and
the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on
the knowledge and technical facilities available at AT4 wireless at the time of performance of the test.
AT4 wireless is liable to the client for the maintenance of the confidentiality of all information related to the item
under test and the results of the test.
The results presented in this Test Report apply only to the particular item under test established in this document.
IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
except in full, without the previous written permission of AT4 wireless.
General conditions
1. This report is only referred to the item that has undergone the test.
2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or
competent Authorities.
3. This document is only valid if complete; no partial reproduction can be made without previous written permission of
AT4 wireless.
4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written
permission of AT4 wireless and the Accreditation Bodies.
Uncertainty
Uncertainty (factor k=2) was calculated according to the AT4 wireless internal document PODT000.
Usage of samples
Samples undergoing test have been selected by: the client
Sample S/01 is composed of the following elements:
Control Nº
Description
Model
Serial Nº
Date of reception
51934/018
Mobile Data Gateway
OKO 5875
01000002
2017-01-11
51934/024
Battery
ABAT M020
12345678
2017-01-11
51934/030
Antenna
2JW0124
---
2017-01-11
1. Sample S/01 has undergone following test(s).
All radiated tests indicated in appendix A.
Report No: (NIE)
51934RRF.002
Page 3 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Sample S/02 is composed of the following elements:
Control Nº
Description
Model
Serial Nº
Date of reception
51934/016
Mobile Data Gateway
OKO 5875
01000001
2017-01-11
51934/024
Battery
ABAT M020
12345678
2017-01-11
1. Sample S/02 has undergone following test(s).
All conducted tests indicated in appendix A.
Test sample description
The product OKO 5875, a compact, battery-powered mobile data gateway, is an essential element of IMR Tank Monitoring
System that has been designed, developed and manufacturer by AIUT. OKO 5875 receives via radio measurements from
assigned smart level sensors ALEVEL 0275 installed on propane tanks. With configured frequency OKO 5875 collects the
tank level/volume data and retransmits the current stock information, archive measurement and the status of the device via
cellular network to acquisition server. OKO 5875 can be mounted next or directly on propane tank. The deice OKO 5875
comprises two printed circuit board with electronic circuitry, and integrated antenna (for link with ALEVEL 0275), a SMA
connector for external mobile antenna and primary battery, all housed in a polycarbonate enclosure.
Identification of the client
AIUT SP. Z O.O.
ul. Wyczólkowskiego 113, 44-109 Gliwice, Poland.
Testing period
The performed test started on 2017-01-31 and finished on 2017-02-06.
The tests have been performed at AT4 wireless.
Environmental conditions
In the control chamber, the following limits were not exceeded during the test:
Temperature
Min. = 15 ºC
Max. = 35 ºC
Relative humidity
Min. = 20 %
Max. = 75 %
Shielding effectiveness
> 100 dB
Electric insulation
> 10 kΩ
Reference resistance to earth
<1Ω
Report No: (NIE)
51934RRF.002
Page 4 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
In the semianechoic chamber, the following limits were not exceeded during the test.
Temperature
Min. = 15 ºC
Max. = 35 ºC
Relative humidity
Min. = 20 %
Max. = 75 %
Air pressure
Min. = 860 mbar
Max. = 1060 mbar
Shielding effectiveness
> 100 dB
Electric insulation
> 10 kΩ
Reference resistance to earth
<1Ω
Normal site attenuation (NSA)
< ±4 dB at 10 m distance between item under test and
receiver antenna, (30 MHz to 1000 MHz)
Field homogeneity
More than 75% of illuminated surface is between 0 and 6
dB (26 MHz to 1000 MHz).
In the chamber for conducted measurements, the following limits were not exceeded during the test:
Temperature
Min. = 15 ºC
Max. = 35 ºC
Relative humidity
Min. = 20 %
Max. = 75 %
Air pressure
Min. = 860 mbar
Max. = 1060 mbar
Shielding effectiveness
> 100 dB
Electric insulation
> 10 kΩ
Reference resistance to earth
<1Ω
Remarks and comments
1: Used instrumentation:
Conducted Measurements
1.
2.
Spectrum analyser Agilent PSA
E4440A
DC power supply R&S NGPE 40/40
Report No: (NIE)
51934RRF.002
Last Cal. date
Cal. due date
2015/10
2017/10
2014/11
2017/11
Page 5 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Radiated Measurements
1.
2.
3.
4.
5.
6.
7.
8.
9.
Semianechoic Absorber Lined Chamber
ETS FACT3 200STP
BiconicalLog
antenna
ETS
LINDGREN 3142E
Multi Device Controller EMCO 2090
Double-ridge Guide Horn antenna 1-18
GHz SCHWARZBECK BBHA 9120 D
Broadband Horn antenna 18-40 GHz
SCHWARZBECK BBHA 9170
EMI Test Receiver R&S ESU 40
Spectrum analyser Rohde & Schwarz
FSW50
RF pre-amplifier 10 MHz-6 GHz
SCHWARZBECK BBV9743
RF pre-amplifier 1-18 GHz Bonn
Elektronik BLMA 0118-1M
Last Cal. date
Cal. due date
N.A.
N.A.
2014/03
2017/03
N.A.
N.A.
2016/11
2019/11
2014/03
2017/03
2016/03
2018/03
2015/12
2017/12
2016/04
2017/04
2016/02
2018/02
Testing verdicts
Not applicable ......................................................................... :
N/A
Pass .......................................................................................... :
Fail ........................................................................................... :
Not measured .......................................................................... :
N/M
FCC PART 15 PARAGRAPH / RSS-210
NA
FCC 15.249 Subclause (a) / RSS-210 B.10. (a)
Field strength of fundamental
and harmonics emissions
FCC 15.249 Subclause (d) / RSS-210 B.10. (b)
Emissions radiated outside of
the specific frequency bands
Report No: (NIE)
51934RRF.002
Page 6 of 21
VERDICT
NM
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Appendix A – Test result “Proprietary radio”
Report No: (NIE)
51934RRF.002
Page 7 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
INDEX
TEST CONDITIONS ............................................................................................................................................................ 9
Occupied Bandwidth ........................................................................................................................................................... 11
Section 15.249 Subclause (a) / RSS-210 B.10. (a) Field strength of Fundamental ............................................................. 14
Section 15.249 Subclause (a) and (d) / RSS-210 B.10 (b) Emissions limitations radiated (Transmitter) ........................... 17
Report No: (NIE)
51934RRF.002
Page 8 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
TEST CONDITIONS
Power supply (V):
Vnominal = 3.3Vdc
Type of power supply = DC voltage from external battery.
Type of antenna = Integral antenna (quarter-wave whip).
Declared Gain for antenna (maximum) = <0 dBi
TEST FREQUENCIES:
Lowest channel: 902.025 MHz
Middle channel: 915.025 MHz
Highest channel: 927.975 MHz
CONDUCTED MEASUREMENTS
The equipment under test was set up in a shielded room and it is directly connected to the spectrum analyzer.
RADIATED MEASUREMENTS
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna is situated at a distance of
3 m for the frequency range 30 MHz-1000 MHz (30 MHz-1000 MHz Bilog antenna) and at a distance of 1m for
the frequency range 1 GHz-10 GHz (1 GHz-18 GHz Double ridge horn antenna).
For radiated emissions in the range 1 GHz-10 GHz that is performed at a distance closer than the specified distance,
an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for determining
compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation and
orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna height was
varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.
Report No: (NIE)
51934RRF.002
Page 9 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Radiated measurements setup f < 1 GHz
Radiated measurements setup f > 1 GHz
Report No: (NIE)
51934RRF.002
Page 10 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Occupied Bandwidth
RESULTS
(see next plots).
Lowest frequency
Middle frequency
Highest frequency
902.025 MHz
915.025 MHz
927.975 MHz
99% bandwidth (kHz)
16.634
16.702
16.776
-26 dBc bandwidth (kHz)
20.483
20.445
20.553
Measurement uncertainty (kHz)
Report No: (NIE)
51934RRF.002
<±0.08
Page 11 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Lowest Channel
Middle Channel
Report No: (NIE)
51934RRF.002
Page 12 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Highest channel
Report No: (NIE)
51934RRF.002
Page 13 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Section 15.249 Subclause (a) / RSS-210 B.10. (a) Field strength of Fundamental
SPECIFICATION
The field strength of emissions from intentional radiators shall comply with the following
Fundamental
frequency (MHz)
Field strength of
fundamental (mV/m)
Field strength
(dBµV/m)
Measurement
distance (m)
902 - 928
50
93.98
2400 – 2483.5
50
93.98
5725 - 5875
50
93.98
24000-24250
250
107.96
For frequencies above 1000 MHz, the above field strength limits are based on average limits. However, the peak
field strength of any emission shall not exceed the maximum permitted average limits specified above by more than
20 dB under any condition of modulation.
RESULTS
Lowest frequency
Middle frequency
Highest frequency
902.025 MHz
915.025 MHz
927.975 MHz
Field strength (dBµV/m) average
93.75
93.63
93.95
Field strength (dBµV/m) peak
93.85
93.73
94.05
Measurement uncertainty (dB)
<±3.88
Verdict: PASS
Report No: (NIE)
51934RRF.002
Page 14 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
FIELD STRENGTH
Lowest Channel
Middle Channel
Report No: (NIE)
51934RRF.002
Page 15 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Highest Channel
Report No: (NIE)
51934RRF.002
Page 16 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Section 15.249 Subclause (a) and (d) / RSS-210 B.10 (b) Emissions limitations radiated (Transmitter)
SPECIFICATION
The field strength of harmonics from intentional radiators shall comply with the following
Fundamental
frequency (MHz)
Field strength of
harmonics (µV/m)
Field strength of
harmonics (dBµV/m)
Measurement
distance (m)
902 - 928
500
54
2400 – 2483.5
500
54
5725 - 5875
500
54
24000-24250
2500
67.96
Emissions radiated outside of the specific frequency bands, except for harmonics, shall be attenuated by at least 50
dB below the level of fundamental or to the general radiated emission limits specified in section 15.209:
Frequency Range
(MHz)
Field strength (µV/m)
Field strength
(dBµV/m)
Measurement
distance (m)
0.009-0.490
2400/F(kHz)
300
0.490-1.705
24000/F(kHz)
30
1.705 - 30.0
30
30
30 - 88
100
40
88 - 216
150
43.5
216 - 960
200
46
960 - 25000
500
54
Whichever is the lesser attenuation.
RESULTS:
The situation and orientation was varied to find the maximum radiated emission. It was also rotated 360º and the
antenna height was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.
All tests were performed in a semi-anechoic chamber at a distance of 3 m for the frequency range 30 MHz-1000
MHz and at distance of 1m for the frequency range 1 GHz-10 GHz.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyzer. This
correction factor includes antenna factor, cable loss and pre-amplifiers gain.
Report No: (NIE)
51934RRF.002
Page 17 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
Frequency range 30 MHz-1000 MHz.
The result does not depend on the operating channel.
Spurious frequency
(MHz)
Polarization
Detector
Emission Level
(dBµV/m)
Measurement
Uncertainty (dB)
268.5876
Quasi-Peak
25.15
± 3.88
398.8910
Quasi-Peak
26.65
± 3.88
710.0346
Quasi-Peak
28.04
± 3.88
Frequency range 1 GHz-10 GHz
The results in the next tables show the maximum measured levels in the 1-10 GHz range.
1. CHANNEL: LOWEST (902.025 MHz).
Spurious frequency
(GHz)
Polarization
3.60835
Detector
Emission Level
Measurement
(dBµV/m)
Uncertainty (dB)
Peak
45.16
<±4.87
Average
43.81
<±4.87
2. CHANNEL: MIDDLE (915.025 MHz).
Spurious frequency
(GHz)
Polarization
3.65995
Detector
Emission Level
Measurement
(dBµV/m)
Uncertainty (dB)
Peak
45.15
<±4.87
Average
43.61
<±4.87
3. CHANNEL: HIGHEST (927.975 MHz).
Spurious frequency
(GHz)
Polarization
3.71185
Detector
Emission Level
Measurement
(dBµV/m)
Uncertainty (dB)
Peak
43.48
<±4.87
Average
41.82
<±4.87
Verdict: PASS
Report No: (NIE)
51934RRF.002
Page 18 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
FREQUENCY RANGE 30 MHz-1000 MHz.
(This plot is valid for all three channels).
Report No: (NIE)
51934RRF.002
Page 19 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
FREQUENCY RANGE 1 GHz to 10 GHz.
CHANNEL: Lowest (902.025MHz).
CHANNEL: Middle (915.025 MHz).
Report No: (NIE)
51934RRF.002
Page 20 of 21
2017-03-03
AT4 wireless, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga ·
España
www.at4wireless.com · C.I.F. A29 507 456
CHANNEL: Highest (927.975 MHz).
Report No: (NIE)
51934RRF.002
Page 21 of 21
2017-03-03
Download: OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Mirror Download [FCC.gov]OKO5875 Mobile Data Gateway Test Report 51934RRF002_DraftV2 Aiut sp. z o.o.
Document ID3318604
Application IDvhzPZkrcm0B6ec7QaLYuDQ==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize35.8kB (447515 bits)
Date Submitted2017-03-16 00:00:00
Date Available2017-03-16 00:00:00
Creation Date2017-03-03 12:58:04
Producing SoftwareGPL Ghostscript 9.04
Document Lastmod2017-03-03 13:00:34
Document Title51934RRF002_DraftV2
Document CreatorPDFCreator Version 1.2.3
Document Author: ALL

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : ALL
Create Date                     : 2017:03:03 12:58:04+01:00
Modify Date                     : 2017:03:03 13:00:34+01:00
Subject                         : 
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : ALL
Description                     : 
Title                           : 51934RRF002_DraftV2
Creator Tool                    : PDFCreator Version 1.2.3
Metadata Date                   : 2017:03:03 13:00:34+01:00
Keywords                        : 
Producer                        : GPL Ghostscript 9.04
Document ID                     : uuid:7d810e4c-e781-43be-b0d4-7d7bff105c8b
Instance ID                     : uuid:efc89445-9c63-4dcb-a5a6-1fded9093f11
Page Count                      : 21
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2017