Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited

Zetta Technologies Limited HD Security Camcorder

FCC ID Filing: 2AMV7-Z18
Purchase on Amazon: HD Security Camcorder

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 2 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 3 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 4 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 5 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 6 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 7 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 8 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 9 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 10 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 11 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 12 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 13 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 14 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 15 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 16 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 17 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 18 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Page 19 of Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited

FCC PART 15 B
TEST REPORT
For
ZETTA TECHNOLOGIES LIMITED
Unit 513, No.8, Science Park west avenue, Shatin , Hong Kong
FCC ID: 2AMV7-Z18
Report Type:
Product Type:
Original Report
HD Security Camcorder
Report Number:
RDG170710009-00A
Report Date:
2017-08-30
Reviewed By:
Test Laboratory:
Jerry Zhang
EMC Manager
Bay Area Compliance Laboratories Corp. (Dongguan)
No.69 Pulongcun, Puxinhu Industry Area,
Tangxia, Dongguan, Guangdong, China
Tel: +86-769-86858888
Fax: +86-769-86858891
www.baclcorp.com.cn
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp.(Dongguan).
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
TABLE OF CONTENTS
GENERAL INFORMATION .......................................................................................................................................3
PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
OBJECTIVE ...................................................................................................................................................................3
RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
TEST METHODOLOGY ..................................................................................................................................................3
MEASUREMENT UNCERTAINTY ....................................................................................................................................3
TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
EUT EXERCISE SOFTWARE ..........................................................................................................................................5
EQUIPMENT MODIFICATIONS .......................................................................................................................................5
LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
CONFIGURATION OF TEST SETUP .................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.107 - CONDUCTED EMISSIONS ................................................................................................................8
EUT SETUP ..................................................................................................................................................................8
EMI TEST RECEIVER SETUP .........................................................................................................................................8
TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
TEST PROCEDURE ........................................................................................................................................................9
CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9
TEST RESULTS SUMMARY ..........................................................................................................................................10
TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ............................................................................................13
EUT SETUP ................................................................................................................................................................13
EMI TEST RECEIVER SETUP .......................................................................................................................................14
TEST PROCEDURE ......................................................................................................................................................14
TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................14
CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................15
TEST DATA ................................................................................................................................................................15
FCC Part15B
Page 2 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The ZETTA TECHNOLOGIES LIMITED’s product, model number: Z18 (FCC ID: 2AMV7-Z18) (the
"EUT") in this report was a HD Security Camcorder , which was measured approximately: 4.2 cm (L) x 2.7
cm (W) x 2.7 cm (H), DC 3.7V from Battery or DC 5V from USB port. The highest operation frequency is
2480 MHz.
*All measurement and test data in this report was gathered from production sample serial number: 170710009
(Assigned by BACL, Dongguan). The EUT was received on 2017-07-11.
Objective
This test report is prepared on behalf of ZETTA TECHNOLOGIES LIMITED in accordance with Part 2,
Subpart J, and Part 15-Subparts A and B of the Federal Communications Commission’s rules.
The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class B.
Related Submittal(s)/Grant(s)
FCC Part 15C DTS submissions with FCC ID: 2AMV7-Z18.
Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.
All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Dongguan).
Measurement Uncertainty
Parameter
Measurement Uncertainty
30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
Unwanted Emissions, radiated
200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
1G~6GHz: 4.45 dB, 6G~18GHz: 5.23 dB
Temperature
±1℃
Humidity
AC Power Lines Conducted Emission
3.12 dB (150 kHz to 30 MHz)
FCC Part15B
±5%
Page 3 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China
Bay Area Compliance Laboratories Corp. (Dongguan) has been accredited to ISO 17025 by CNAS(Lab
code: L5662). And accredited to ISO 17025 by NVLAP(Test Laboratory Accreditation Certificate Number
500069-0), the FCC Designation No. CN5002 under the KDB 974614 D01.
The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
273710. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.
Bay Area Compliance Laboratories Corp. (Dongguan) was registered with ISED Canada under ISED
Canada Registration Number 3062D.
FCC Part15B
Page 4 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in a typical fashion (as normally used by a typical user).
EUT Exercise Software
The software “winthrax.exe” was used during test.
Equipment Modifications
No modification was made to the EUT tested.
Local Support Equipment List and Details
Manufacturer
Description
Model
Serial Number
DELL
Laptop
PP11L
QDS-BRCM1017
HP
Printer
C3941A
JPTVOB2337
DELL
Keyboard
L100
CNORH656658907BL05DC
SAST
Modem
AEM-2100
0293
Kingston
Micro SD Card
4G
Support Cable List and Details
Cable Description
Shielding
Type
Ferrite Core
Length
(m)
From Port
To
Serial Cable
yes
No
1.2
Serial Port of Laptop
Modem
Parallel Cable
yes
No
1.2
Parallel Port of Laptop
Printer
Keyboard Cable
yes
No
1.8
USB Port of Laptop
Keyboard
USB Cable
Yes
No
0.33
EUT
Laptop
FCC Part15B
Page 5 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Configuration of Test Setup
1.0 Meter
FCC Part15B
Page 6 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
SUMMARY OF TEST RESULTS
FCC Rules
Description of Test
Results
§15.107
Conducted Emissions
Compliant
§15.109
Radiated Emissions
Compliant
FCC Part15B
Page 7 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
FCC§15.107 - CONDUCTED EMISSIONS
EUT Setup
The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The specification used
was with the FCC Part 15 B Class B limits.
The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle.
The adapter was connected to the Main LISN with 120V/60Hz AC power source.
EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.
During the conducted emission test, the EMI test receiver was set with the following configurations:
FCC Part15B
Frequency Range
IF B/W
150 kHz – 30 MHz
9 kHz
Page 8 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Test Equipment List and Details
892107/021
Calibration
Date
2016-09-01
Calibration
Due Date
2017-09-01
ENV 216
3560.6550.12
2016-12-08
2017-12-08
EMC32
2m
ESCS 30
Version8.53.0
Con-1
830245/006
N/A
2016-09-01
2016-12-08
N/A
2017-09-01
2017-12-08
Manufacturer
Description
Model
Serial Number
R&S
L.I.S.N
Two-line
V-network
Test Software
Coaxial Cable
EMI Test Receiver
ESH2-Z5
R&S
R&S
Unknown
R&S
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed traceable to National Primary Standards and International System of Units (SI).
Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the first LISN and the other
support equipments were connected to the outlet of the second LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.
All data was recorded in the Quasi-peak and average detection mode.
Corrected Amplitude & Margin Calculation
The basic equation is as follows:
VC = VR + AC + VDF
Herein,
VC: corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN or ISN
The “Margin” column of the following data tables indicates the degree of compliance within the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:
Margin = Limit – Corrected Amplitude
FCC Part15B
Page 9 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15 B Class B.
Test Data
Environmental Conditions
Temperature:
Relative Humidity:
ATM Pressure:
27.0C
51%
100.3 kPa
The testing was performed by Gaochao Gong on 2017-08-28.
FCC Part15B
Page 10 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Test Mode: Downloading
AC120V, 60Hz, Line:
80
70
Quasi-Peak Limit
60
Average Limit
Level in dBμ
50
40
30
20
10
150k
300
400 500
800 1M
2M
3M
4M 5M 6
8 10M
20M
30M
Frequency in Hz
Frequency
(MHz)
0.154858
0.193566
0.257874
0.338116
1.488418
4.193667
QuasiPeak
(dBμV)
41.3
56.5
46.7
41.6
36.9
37.6
Bandwidth
(kHz)
9.000
9.000
9.000
9.000
9.000
9.000
Frequency
(MHz)
0.206306
0.257874
1.418932
Average
(dBμV)
42.2
30.0
24.1
Bandwidth
(kHz)
9.000
9.000
9.000
1.488418
2.381750
4.127365
26.5
26.3
28.4
9.000
9.000
9.000
FCC Part15B
Corr.
(dB)
11.1
10.7
10.3
10.1
9.7
9.8
Margin
(dB)
24.4
7.4
14.8
17.6
19.1
18.4
Limit
(dBμV)
65.7
63.9
61.5
59.2
56.0
56.0
L1
L1
L1
Corr.
(dB)
10.6
10.3
9.7
Margin
(dB)
11.2
21.5
21.9
Limit
(dBμV)
53.4
51.5
46.0
Compliance
Compliance
Compliance
L1
L1
L1
9.7
9.8
9.8
19.5
19.7
17.6
46.0
46.0
46.0
Compliance
Compliance
Compliance
Line
L1
L1
L1
L1
L1
L1
Line
Comment
Compliance
Compliance
Compliance
Compliance
Compliance
Compliance
Comment
Page 11 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
AC120V, 60Hz, Neutral:
80
70
Quasi-Peak Limit
60
Average Limit
Level in dBμ
50
40
30
20
10
150k
300
400 500
800 1M
2M
3M
4M 5M 6
8 10M
20M
30M
Frequency in Hz
Frequency
(MHz)
0.150000
0.192030
0.259937
1.500325
2.147382
3.934683
QuasiPeak
(dBμV)
44.1
55.6
45.8
45.6
39.3
37.3
Bandwidth
(kHz)
9.000
9.000
9.000
9.000
9.000
9.000
Frequency
(MHz)
0.199835
0.264113
1.430284
1.500325
1.920710
2.234662
Average
(dBμV)
41.5
33.6
39.3
40.5
28.3
29.2
Bandwidth
(kHz)
9.000
9.000
9.000
9.000
9.000
9.000
FCC Part15B
Line
Line
Corr.
(dB)
11.2
10.7
10.3
9.7
9.8
9.8
Margin
(dB)
21.9
8.3
15.6
10.4
16.7
18.7
Limit
(dBμV)
66.0
63.9
61.4
56.0
56.0
56.0
Corr.
(dB)
10.6
10.3
9.7
9.7
9.7
9.8
Margin
(dB)
12.1
17.7
6.7
5.5
17.7
16.8
Limit
(dBμV)
53.6
51.3
46.0
46.0
46.0
46.0
Comment
Compliance
Compliance
Compliance
Compliance
Compliance
Compliance
Comment
Compliance
Compliance
Compliance
Compliance
Compliance
Compliance
Page 12 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
FCC §15.109 - RADIATED SPURIOUS EMISSIONS
EUT Setup
Below 1GHz:
Above 1GHz:
The radiated emission tests were performed in the 3 meters chamber test site for the range 30MHz to 1GHz
and the 3 meters chamber test site for above 1GHz, using the setup accordance with the ANSI C63.4-2014.
The specification used was the FCC Part 15.109 Class B limits.
FCC Part15B
Page 13 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
EMI Test Receiver Setup
The system was investigated from 30 MHz to 13 GHz.
During the radiated emission test, the EMI test receiver was set with the following configurations:
Frequency Range
RBW
Video B/W
IF B/W
Detector
30 MHz – 1000 MHz
120 kHz
300 kHz
120 kHz
QP
1 MHz
3 MHz
Peak
1 MHz
10 Hz
AVG
Above 1 GHz
Test Procedure
During the radiated emissions, the adapter was connected to the first AC floor outlet and the other support
equipments were connected to the second AC floor outlet.
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average detection mode
above 1 GHz.
Test Equipment List and Details
Manufacturer
Description
Model
R&S
Sunol Sciences
HP
Agilent
ETS-Lindgren
Mini-Circuit
Quinstar
Unknown
Unknown
Unknown
Unknown
EMI Test Receiver
Antenna
Amplifier
Spectrum Analyzer
Horn Antenna
Amplifier
Amplifier
Coaxial Cable
Coaxial Cable
Coaxial Cable
Coaxial Cable
Test Software
ESCI
JB3
8447E
E4440A
3115
ZVA-213-S+
QLW-18405536-JO
Chamber A-1
Chamber B-1
Chamber A-2
Chamber B-2
EZ-EMC
Farad
Serial
Number
100224
A060611-1
2434A02181
SG43360054
000 527 35
SN054201245
15964001001
4m
0.75m
10m
8m
V1.1.4.2
Calibration
Date
2016-09-01
2014-11-06
2016-09-01
2016-12-08
2016-01-05
2017-02-19
2016-09-06
2016-09-01
2016-09-01
2016-09-01
2016-09-01
N/A
Calibration
Due Date
2017-08-31
2017-11-05
2017-09-01
2017-12-08
2019-01-04
2018-02-19
2017-09-06
2017-09-01
2017-09-01
2017-09-01
2017-09-01
N/A
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).
FCC Part15B
Page 14 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
Margin = Limit – Corrected Amplitude
Test Data
Environmental Conditions
Temperature:
Relative Humidity:
ATM Pressure:
26.2~28.6 C
34~46 %
100~100.5 kPa
* The testing was performed by Calvin Chen on 2017-08-26&2017-08-29.
Test Result: Compliance
FCC Part15B
Page 15 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Test Mode: Downloading
1) Below 1GHz:
Horizontal
Frequency
(MHz)
Receiver
Reading
(dBμV)
Detector
Correction
Factor
(dB/m)
Cord.
Amp.
(dBμV/m)
Limit
(dBμV/m)
Margin
(dB)
56.1900
148.3400
195.8700
208.4800
239.5200
527.6100
47.35
39.19
43.39
45.13
43.22
38.85
QP
QP
QP
QP
QP
QP
-12.45
-6.69
-6.99
-7.53
-6.32
-0.45
34.90
32.50
36.40
37.60
36.90
38.40
40.00
43.50
43.50
43.50
46.00
46.00
5.10
11.00
7.10
5.90
9.10
7.60
FCC Part15B
Page 16 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Vertical
Frequency
(MHz)
Receiver
Reading
(dBμV)
Detector
Correction
Factor
(dB/m)
Cord.
Amp.
(dBμV/m)
Limit
(dBμV/m)
Margin
(dB)
57.1600
143.4900
195.8700
239.5200
471.3500
528.5800
40.43
36.36
32.89
33.72
32.18
38.49
QP
QP
QP
QP
QP
QP
-12.53
-6.56
-6.99
-6.32
-0.98
-0.39
27.90
29.80
25.90
27.40
31.20
38.10
40.00
43.50
43.50
46.00
46.00
46.00
12.10
13.70
17.60
18.60
14.80
7.90
FCC Part15B
Page 17 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
2) Above 1GHz:
Horizontal
Frequency
(MHz)
Receiver
Reading
(dBμV)
Detector
Correction
Factor
(dB/m)
Cord.
Amp.
(dBμV/m)
Limit
(dBμV/m)
Margin
(dB)
3298.000
3298.000
5938.000
5938.000
7780.000
7780.000
45.50
35.12
45.82
35.33
45.02
34.91
peak
AVG
peak
AVG
peak
AVG
-0.61
-0.61
3.08
3.08
6.57
6.57
44.89
34.51
48.90
38.41
51.59
41.48
74.00
54.00
74.00
54.00
74.00
54.00
29.11
19.49
25.10
15.59
22.41
12.52
FCC Part15B
Page 18 of 19
Bay Area Compliance Laboratories Corp. (Dongguan)
Report No.: RDG170710009-00A
Vertical
Frequency
(MHz)
Receiver
Reading
(dBμV)
Detector
Correction
Factor
(dB/m)
Cord.
Amp.
(dBμV/m)
Limit
(dBμV/m)
Margin
(dB)
3196.000
3196.000
5812.000
5812.000
7870.000
7870.000
51.90
41.21
46.84
36.55
45.28
35.00
peak
AVG
peak
AVG
peak
AVG
-0.96
-0.96
3.03
3.03
6.65
6.65
50.94
40.25
49.87
39.58
51.93
41.65
74.00
54.00
74.00
54.00
74.00
54.00
23.06
13.75
24.13
14.42
22.07
12.35
****END OF REPORT****
FCC Part15B
Page 19 of 19
Download: Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Mirror Download [FCC.gov]Z18 HD Security Camcorder Test Report RDG170710009-00A_EMC-EMI Report Zetta Technologies Limited
Document ID3557882
Application IDHwUFWYTNpZ1ii0O+nb83MA==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize27.78kB (347198 bits)
Date Submitted2017-09-12 00:00:00
Date Available2017-09-12 00:00:00
Creation Date2017-09-08 18:38:30
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-09-08 18:38:59
Document TitleRDG170710009-00A_EMC-EMI Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: DG06181

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : DG06181
Create Date                     : 2017:09:08 18:38:30+08:00
Modify Date                     : 2017:09:08 18:38:59+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:09:08 18:38:59+08:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - RDG170710009-00A_EMC-EMI Report
Creator                         : DG06181
Document ID                     : uuid:48bf3a08-9531-4e7c-9c83-b7248971bf98
Instance ID                     : uuid:502c4d0d-e25d-4302-aa2e-40373e77fc27
Page Count                      : 19
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2018