COOL-P800 Mini-split air conditioner Test Report 3B TECH Inc

3B TECH Inc Mini-split air conditioner

FCC ID Filing: 2ANDE-COOL-P800
Purchase on Amazon: Mini-split air conditioner

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 2 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 3 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 4 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 5 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 6 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 7 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 8 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 9 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 10 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 11 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 12 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 13 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 14 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 15 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 16 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 17 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 18 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 19 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 20 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 21 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 22 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 23 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 24 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 25 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 26 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 27 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 28 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 29 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 30 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 31 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 32 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 33 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 34 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 35 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 36 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 37 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 38 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 39 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 40 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 41 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 42 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 43 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 44 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 45 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 46 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 47 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 48 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 49 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 50 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 51 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 52 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 53 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 54 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 55 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 56 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 57 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 58 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 59 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 60 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 61 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 62 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 63 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc

Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 1 of 63 Report No.: R0217060020W1
FCC TEST REPORT
For
3B TECH Inc
Mini-split air conditioner
Model No.: COOL-P800
Prepared For
: 3B TECH Inc
Address
: 3431 William Richardson Dr., South Bend, IN 46628
Prepared By
: Shenzhen Anbotek Compliance Laboratory Limited
Address
: 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, Nanshan
District, Shenzhen, Guangdong, China
Tel: (86) 755-26066544
Report Number
: R0217060020W1
Date of Test
: Jun. 02~Jul. 04, 2017
Date of Report
: Jul. 04, 2017
Fax: (86) 755-26014772
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 2 of 63 Report No.: R0217060020W1
Contents
1. General Information..................................................................................................................................................5
1.1. Client Information......................................................................................................................................... 5
1.2. Description of Device (EUT)........................................................................................................................ 5
1.3. Auxiliary Equipment Used During Test........................................................................................................ 5
1.4. Description of Test Modes.............................................................................................................................6
1.5. List of channels..............................................................................................................................................7
1.6. Description Of Test Setup..............................................................................................................................8
1.7. Test Equipment List....................................................................................................................................... 9
1.8. Measurement Uncertainty..............................................................................................................................9
1.9. Description of Test Facility......................................................................................................................... 10
2. Summary of Test Results........................................................................................................................................ 11
3. Conducted Emission Test........................................................................................................................................12
3.1. Test Standard and Limit...............................................................................................................................12
3.2. Test Setup.....................................................................................................................................................12
3.3. Test Procedure..............................................................................................................................................12
3.4. Test Data...................................................................................................................................................... 12
4. Radiation Spurious Emission and Band Edge........................................................................................................ 17
4.1. Test Standard and Limit...............................................................................................................................17
4.2. Test Setup.....................................................................................................................................................17
4.3. Test Procedure..............................................................................................................................................18
4.4. Test Data...................................................................................................................................................... 19
5. Maximum Peak Output Power Test........................................................................................................................26
5.1. Test Standard and Limit...............................................................................................................................26
5.2. Test Setup.....................................................................................................................................................26
5.3. Test Procedure..............................................................................................................................................26
5.4. Test Data...................................................................................................................................................... 26
6. 20DB Occupy Bandwidth Test............................................................................................................................... 30
6.1. Test Standard................................................................................................................................................30
6.2. Test Setup.....................................................................................................................................................30
6.3. Test Procedure..............................................................................................................................................30
6.4. Test Data...................................................................................................................................................... 30
7. Carrier Frequency Separation Test......................................................................................................................... 34
7.1. Test Standard and Limit...............................................................................................................................34
7.2. Test Setup.....................................................................................................................................................34
7.3. Test Procedure..............................................................................................................................................34
7.4. Test Data...................................................................................................................................................... 34
8. Number of Hopping Channel Test..........................................................................................................................38
8.1. Test Standard and Limit...............................................................................................................................38
8.2. Test Setup.....................................................................................................................................................38
8.3. Test Procedure..............................................................................................................................................38
8.4. Test Data...................................................................................................................................................... 38
9. Dwell Time Test......................................................................................................................................................40
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 3 of 63 Report No.: R0217060020W1
9.1. Test Standard and Limit...............................................................................................................................40
9.2. Test Setup.....................................................................................................................................................40
9.3. Test Procedure..............................................................................................................................................40
9.4. Test Data...................................................................................................................................................... 40
10. 100kHz Bandwidth of Frequency Band Edge Requirement................................................................................ 44
10.1. Test Standard and Limit.............................................................................................................................44
10.2. Test Setup...................................................................................................................................................44
10.3. Test Procedure............................................................................................................................................44
10.4. Test Data.................................................................................................................................................... 44
11. Antenna Requirement............................................................................................................................................49
11.1. Test Standard and Requirement................................................................................................................. 49
11.2. Antenna Connected Construction.............................................................................................................. 49
APPENDIX I -- TEST SETUP PHOTOGRAPH....................................................................................................... 50
APPENDIX II -- EXTERNAL PHOTOGRAPH....................................................................................................... 52
APPENDIX III -- INTERNAL PHOTOGRAPH.......................................................................................................56
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 4 of 63 Report No.: R0217060020W1
TEST REPORT
Applicant
3B TECH Inc
Manufacturer
3B TECH Inc
Product Name
Mini-split air conditioner
Model No.
COOL-P800
Trade Mark
rollibot
Rating(s)
Input: AC 120-240V, 50/60Hz, 13A, 1560W
Test Standard(s)
FCC Part15 Subpart C 2016, Section 15.247
Test Method(s)
ANSI C63.10: 2013
The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the
maximum emission levels emanating from the device and the severe levels of the device can endure and its
performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek
Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these
measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the
FCC Part 15 Subpart C requirements.
This report applies to above tested sample only and shall not be reproduced in part without written approval of
Shenzhen Anbotek Compliance Laboratory Limited.
Date of Test :
Jun. 02~Jul. 04, 2017
Prepared by :
(Tested Engineer / Winkey Wang)
Reviewer :
(Project Manager / Dolly Mo)
Approved & Authorized Signer :
(Manager / Tom Chen)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 5 of 63 Report No.: R0217060020W1
1. General Information
1.1. Client Information
Applicant
3B TECH Inc
Address
3431 William Richardson Dr., South Bend, IN 46628
Manufacturer
3B TECH Inc
Address
3431 William Richardson Dr., South Bend, IN 46628
1.2. Description of Device (EUT)
Product Name
Mini-split air conditioner
Model No.
COOL-P800
Trade Mark
rollibot
Test Power Supply
AC 120V, 60Hz/AC 240V, 60Hz
Product
Description
Operation Frequency:
WiFi 2.4G 802.11b/ g/ n(HT20) 2412-2462MHz
WiFi 2.4G 802.11n(HT40) 2422-2452MHz
BT 3.0: 2402MHz~2480MHz
BT 4.0: 2402MHz~2480MHz
Transfer Rate:
1/2/3 Mbits/s
Number of Channel:
WiFi 2.4G: 11 Channels for 802.11b/ g/ n(HT20)
WiFi 2.4G: 7 Channels for 802.11n(HT40)
BT 4.0: 40 Channels
Modulation Type:
WiFi 2.4G: 802.11b CCK; 802.11g/n OFDM
BT 3.0: GFSK, π/4-DQPSK, 8-DPSK
BT 4.0: GFSK
Antenna Type:
PCB Antenna
Antenna Gain(Peak):
1.0 dBi
Remark: 1) For a more detailed features description, please refer to the manufacturer’s specifications or the
User’s Manual.
2)This report is for BT 3.0
1.3. Auxiliary Equipment Used During Test
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 6 of 63 Report No.: R0217060020W1
1.4. Description of Test Modes
To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning
tested base on the consideration of following EUT operation mode or test configuration mode which possible have
effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned
above was evaluated respectively.
Pretest Mode
Description
Mode 1
CH00
Mode 2
CH39
Mode 3
CH78
Mode 4
Keeping TX mode
For Conducted Emission
Final Test Mode
Description
Mode 4
Keeping TX mode
For Radiated Emission
Final Test Mode
Description
Mode 1
CH00
Mode 2
CH39
Mode 3
CH78
Note:
(1) The measurements are performed at the highest, middle, lowest available channels.
(2)The data rate was set in 1Mbps for radiated emission due to the highest RF output power.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 7 of 63 Report No.: R0217060020W1
1.5. List of channels
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
00
2402
17
2419
34
2436
51
2453
68
2470
01
2403
18
2420
35
2437
52
2454
69
2471
02
2404
19
2421
36
2438
53
2455
70
2472
03
2405
20
2422
37
2439
54
2456
71
2473
04
2406
21
2423
38
2440
55
2457
72
2474
05
2407
22
2424
39
2441
56
2458
73
2475
06
2408
23
2425
40
2442
57
2459
74
2476
07
2409
24
2426
41
2443
58
2460
75
2477
08
2410
25
2427
42
2444
59
2461
76
2478
09
2411
26
2428
43
2445
60
2462
77
2479
10
2412
27
2429
44
2446
61
2463
78
2480
11
2413
28
2430
45
2447
62
2464
12
2414
29
2431
46
2448
63
2465
13
2415
30
2432
47
2449
64
2466
14
2416
31
2433
48
2450
65
2467
15
2417
32
2434
49
2451
66
2468
16
2418
33
2435
50
2452
67
2469
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 8 of 63 Report No.: R0217060020W1
1.6. Description Of Test Setup
CE
E-1
EUT
AC Line
0.8m
Table
Table
1.5m
RE
E-1
EUT
0.8m
Table
1.5m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
LISN
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 9 of 63 Report No.: R0217060020W1
1.7. Test Equipment List
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal.
Interval
1.
L.I.S.N.
Artificial Mains
Network
Rohde & Schwarz
ENV216
100055
May 27, 2017
1 Year
2.
EMI Test Receiver
Rohde & Schwarz
ESCI
100627
May 27, 2017
1 Year
3.
RF Switching Unit
Compliance
Direction
RSU-M2
38303
May 27, 2017
1 Year
4.
Spectrum Analysis
Agilent
E4407B
US39390582
May 27, 2017
1 Year
5.
Preamplifier
SKET Electronic
BK1G18G30
KD17503
May 27, 2017
1 Year
6.
EMI Test Receiver
Rohde & Schwarz
ESPI
101604
May 27, 2017
1 Year
7.
Double Ridged Horn
Antenna
Instruments
corporation
GTH-0118
351600
May 31, 2017
1 Year
8.
Bilog Broadband
Antenna
Schwarzbeck
VULB9163
VULB 9163-289
May 31, 2017
1 Year
9.
Loop Antenna
HFH2-Z2
100047
Apr. 03, 2017
1 Year
10.
Pre-amplifier
SONOMA
310N
186860
May 27, 2017
1 Year
11.
EMI Test Software
EZ-EMC
SHURPLE
N/A
N/A
N/A
N/A
12.
Power Sensor
DAER
RPR3006W
15I00041SN045
May 27, 2017
1 Year
13.
Power Sensor
DAER
RPR3006W
15I00041SN046
May 27, 2017
1 Year
14.
MXA Spectrum
Analysis
Agilent
N9020A
MY51170037
May 27, 2017
1 Year
15.
MXG RF Vector
Signal Generator
Agilent
N5182A
MY48180656
May 27, 2017
1 Year
16.
Signal Generator
Agilent
E4421B
MY41000743
May 27, 2017
1 Year
17.
DC Power supply
IVYTECH
IV6003
1601D6030007
May 26, 2017
1 Year
18.
TEMP&HUMI
PROGRAMMABLE
CHAMBER
Sertep
ZJ-HWHS80
ZJ-17042804
Mar. 03, 2017
1 Year
Schwarzbeck
1.8. Measurement Uncertainty
Radiation Uncertainty
Ur = 4.1 dB (Horizontal)
Ur = 4.3 dB (Vertical)
Conduction Uncertainty
Uc = 3.4dB
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 10 of 63 Report No.: R0217060020W1
1.9. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 752021
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a
report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
maintained in our files. Registration 752021, July 06, 2016.
ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a
report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from
the ISED is maintained in our files. Registration 8058A-1, June 13, 2016.
Test Location
All Emissions tests were performed at
Shenzhen Anbotek Compliance Laboratory Limited.
at 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, Nanshan District, Shenzhen, Guangdong, China
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 11 of 63 Report No.: R0217060020W1
2. Summary of Test Results
Standard Section
Test Item
Result
15.203/15.247(c)
Antenna Requirement
PASS
15.207
Conducted Emission
PASS
15.205/15.209
Spurious Emission
PASS
15.247(b)(1)
Conducted Peak Output Power
PASS
15.247(a)(1)
20dB Occupied Bandwidth
PASS
15.247(a)(1)
Carrier Frequencies Separation
PASS
15.247(a)(1)
Hopping Channel Number
PASS
15.247(a)(1)
Dwell Time
PASS
15.247(d)
Band Edge
PASS
Remark: “N/A” is an abbreviation for Not Applicable.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 12 of 63 Report No.: R0217060020W1
3. Conducted Emission Test
3.1. Test Standard and Limit
Test Standard
FCC Part15 Section 15.207
Frequency
Test Limit
Maximum RF Line Voltage (dBuV)
Quasi-peak Level
Average Level
150kHz~500kHz
66 ~ 56 *
56 ~ 46 *
500kHz~5MHz
56
46
5MHz~30MHz
60
50
Remark: (1) *Decreasing linearly with logarithm of the frequency.
(2) The lower limit shall apply at the transition frequency.
3.2. Test Setup
3.3. Test Procedure
The EUT system is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This
provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and
photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the
maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed
according to FCC ANSI C63.10-2013 on Conducted Emission Measurement.
The bandwidth of test receiver (ESCI) set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.
3.4. Test Data
Please to see the following pages
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 13 of 63 Report No.: R0217060020W1
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 120V, 60Hz
Comment:
Live Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 14 of 63 Report No.: R0217060020W1
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 120V, 60Hz
Comment:
Neutral Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 15 of 63 Report No.: R0217060020W1
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 240V, 60Hz
Comment:
Live Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 16 of 63 Report No.: R0217060020W1
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 240V, 60Hz
Comment:
Neutral Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 17 of 63 Report No.: R0217060020W1
4. Radiation Spurious Emission and Band Edge
4.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.209 and 15.205
Test Limit
Frequency
(MHz)
Field strength
(microvolt/meter)
Limit
(dBuV/m)
Remark
Measurement
distance (m)
0.009MHz~0.490MHz
2400/F(kHz)
300
0.490MHz-1.705MHz
24000/F(kHz)
30
1.705MHz-30MHz
30
30
30MHz~88MHz
100
40.0
Quasi-peak
88MHz~216MHz
150
43.5
Quasi-peak
216MHz~960MHz
200
46.0
Quasi-peak
960MHz~1000MHz
500
54.0
Quasi-peak
500
54.0
Average
74.0
Peak
Above 1000MHz
Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the maximum permitted average
emission limit applicable to the equipment under test. This peak limit applies to the total peak emission level radiated by the device.
4.2. Test Setup
Figure 1. Below 30MHz
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 18 of 63 Report No.: R0217060020W1
Figure 2. 30MHz to 1GHz
Figure 3. Above 1 GHz
4.3. Test Procedure
For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane.
For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane.
The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3
meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and
down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes
to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The
EUT is tested in 9*6*6 Chamber. The device is evaluated in xyz orientation.
For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 19 of 63 Report No.: R0217060020W1
For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz,Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For above 1GHz,Set the spectrum analyzer as:
RBW =1MHz, VBW =1MHz, Detector= Peak, Trace mode= Max hold, Sweep- auto couple.
RBW =1MHz, VBW =10Hz, Detector= Average, Trace mode= Max hold, Sweep- auto couple.
4.4. Test Data
PASS
During the test, pre-scan the GFSK, π/4QPSK, 8DPSK modulation, and found the GFSK modulation which is
worse case.
The test results of 9kHz-30MHz and above 18000MHz are attenuated more than 20dB below the permissible
limits, so the results don't record in the report.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 20 of 63 Report No.: R0217060020W1
Test Results (30~1000MHz)
Job No.:
0217060020W
Temp.(℃)/Hum.(%RH):
24.3℃/55%RH
Standard:
FCC PART 15C
Power Source:
AC 120V, 60Hz
Test Mode:
TX Mode
Polarization:
Horizontal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 21 of 63 Report No.: R0217060020W1
Test Results (30~1000MHz)
Job No.:
0217060020W
Temp.(℃)/Hum.(%RH):
24.3℃/55%RH
Standard:
FCC PART 15C
Power Source:
AC 120V, 60Hz
Test Mode:
TX Mode
Polarization:
Vertical
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 22 of 63 Report No.: R0217060020W1
Test Results (Above 1000MHz)
Test Mode: GFSK
Test channel: Lowest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4804.00
38.73
34.04
6.58
34.09
45.26
74.00
-28.74
7206.00
32.78
37.11
7.73
34.50
43.12
74.00
-30.88
9608.00
32.31
39.31
9.23
34.79
46.06
74.00
-27.94
12010.00
74.00
14412.00
74.00
4804.00
43.31
34.04
6.58
34.09
49.84
74.00
-24.16
7206.00
34.66
37.11
7.73
34.50
45.00
74.00
-29.00
9608.00
31.87
39.31
9.23
34.79
45.62
74.00
-28.38
12010.00
74.00
14412.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4804.00
27.28
34.04
6.58
34.09
33.81
54.00
-20.19
7206.00
21.30
37.11
7.73
34.50
31.64
54.00
-22.36
9608.00
20.29
39.31
9.23
34.79
34.04
54.00
-19.96
12010.00
54.00
14412.00
54.00
4804.00
31.66
34.04
6.58
34.09
38.19
54.00
-15.81
7206.00
23.57
37.11
7.73
34.50
33.91
54.00
-20.09
9608.00
20.14
39.31
9.23
34.79
33.89
54.00
-20.11
12010.00
54.00
14412.00
54.00
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 23 of 63 Report No.: R0217060020W1
Test Results (Above 1000MHz)
Test Mode: GFSK
Test channel: Middle
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4882.00
37.37
34.38
6.69
34.09
44.35
74.00
-29.65
7323.00
31.87
37.22
7.78
34.53
42.34
74.00
-31.66
9764.00
31.51
39.46
9.35
34.80
45.52
74.00
-28.48
12205.00
74.00
14646.00
74.00
4882.00
41.67
34.38
6.69
34.09
48.65
74.00
-25.35
7323.00
33.64
37.22
7.78
34.53
44.11
74.00
-29.89
9764.00
30.94
39.46
9.35
34.80
44.95
74.00
-29.05
12205.00
74.00
14646.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4882.00
26.19
34.38
6.69
34.09
33.17
54.00
-20.83
7323.00
20.56
37.22
7.78
34.53
31.03
54.00
-22.97
9764.00
19.63
39.46
9.35
34.80
33.64
54.00
-20.36
12205.00
54.00
14646.00
54.00
4882.00
30.42
34.38
6.69
34.09
37.40
54.00
-16.60
7323.00
22.74
37.22
7.78
34.53
33.21
54.00
-20.79
9764.00
19.37
39.46
9.35
34.80
33.38
54.00
-20.62
12205.00
54.00
14646.00
54.00
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 24 of 63 Report No.: R0217060020W1
Test Results (Above 1000MHz)
Test Mode: GFSK
Test channel: Highest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4960.00
36.19
34.72
6.79
34.09
43.61
74.00
-30.39
7440.00
31.09
37.34
7.82
34.57
41.68
74.00
-32.32
9920.00
30.81
39.62
9.46
34.81
45.08
74.00
-28.92
12400.00
74.00
14880.00
74.00
4960.00
40.25
34.72
6.79
34.09
47.67
74.00
-26.33
7440.00
32.75
37.34
7.82
34.57
43.34
74.00
-30.66
9920.00
30.13
39.62
9.46
34.81
44.40
74.00
-29.60
12400.00
74.00
14880.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4960.00
25.27
34.72
6.79
34.09
32.69
54.00
-21.31
7440.00
19.94
37.34
7.82
34.57
30.53
54.00
-23.47
9920.00
19.08
39.62
9.46
34.81
33.35
54.00
-20.65
12400.00
54.00
14880.00
54.00
4960.00
29.38
34.72
6.79
34.09
36.80
54.00
-17.20
7440.00
22.04
37.34
7.82
34.57
32.63
54.00
-21.37
9920.00
18.72
39.62
9.46
34.81
32.99
54.00
-21.01
12400.00
54.00
14880.00
54.00
Remark:
1. During the test, pre-scan the GFSK, π/4QPSK, 8DPSK modulation, and found the GFSK modulation is worse case,
the report only record this mode.
2. Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
3. “*”, means this data is the too weak instrument of signal is unable to test.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 25 of 63 Report No.: R0217060020W1
Radiated Band Edge:
Test Mode: GFSK
Test channel: Lowest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
45.49
29.15
3.41
34.01
44.04
74.00
-29.96
2400.00
62.65
29.16
3.43
34.01
61.23
74.00
-12.77
2390.00
46.28
29.15
3.41
34.01
44.83
74.00
-29.17
2400.00
64.96
29.16
3.43
34.01
63.54
74.00
-10.46
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
35.45
29.15
3.41
34.01
34.00
54.00
-20.00
2400.00
46.84
29.16
3.43
34.01
45.42
54.00
-8.58
2390.00
35.58
29.15
3.41
34.01
34.13
54.00
-19.87
2400.00
48.74
29.16
3.43
34.01
47.32
54.00
-6.68
Test Mode: GFSK
Test channel: Highest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
47.90
29.28
3.53
34.03
46.68
74.00
-27.32
2500.00
46.58
29.30
3.56
34.03
45.41
74.00
-28.59
2483.50
49.18
29.28
3.53
34.03
47.96
74.00
-26.04
2500.00
47.82
29.30
3.56
34.03
46.65
74.00
-27.35
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
38.30
29.28
3.53
34.03
37.08
54.00
-16.92
2500.00
35.93
29.30
3.56
34.03
34.76
54.00
-19.24
2483.50
39.73
29.28
3.53
34.03
38.51
54.00
-15.49
2500.00
36.07
29.30
3.56
34.03
34.90
54.00
-19.10
Remark:
1. During the test, pre-scan the GFSK, π/4QPSK, 8DPSK modulation, and found the GFSK modulation is worse case,
the report only record this mode.
2. Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 26 of 63 Report No.: R0217060020W1
5. Maximum Peak Output Power Test
5.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (b)(3)
Test Limit
1W or 125 mW
5.2. Test Setup
5.3. Test Procedure
1. The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block diagram
above,
2. Spectrum Setting:
RBW > the 20 dB bandwidth of the emission being measured
Span = approximately 5 times the 20 dB bandwidth, centered on a hopping channel
VBW  RBW
Sweep = auto
Detector function = peak
Trace = max hold
5.4. Test Data
Test Item
Test Voltage
Test Result
Max. peak output power
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Channel Frequency
(MHz)
Peak Power output
(dBm)
Limit
(dBm)
Results
Modulation
2402
-0.503
30
PASS
BDR
2441
-1.873
30
PASS
BDR
2480
0.080
30
PASS
BDR
2402
-0.997
20.96
PASS
EDR
2441
-0.588
20.96
PASS
EDR
2480
0.933
20.96
PASS
EDR
Remark: The EDR was tested on (π/4DQPSK, 8DPSK) modes, only the worst data of (8DPSK) is attached in the following
pages.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 27 of 63 Report No.: R0217060020W1
Test Mode: BDR---Low
Test Mode: BDR---Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 28 of 63 Report No.: R0217060020W1
Test Mode: BDR---High
Test Mode: EDR---Low
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 29 of 63 Report No.: R0217060020W1
Test Mode: EDR---Middle
Test Mode: EDR---High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 30 of 63 Report No.: R0217060020W1
6. 20DB Occupy Bandwidth Test
6.1. Test Standard
Test Standard
FCC Part15 C Section 15.247 (a)(1)
6.2. Test Setup
6.3. Test Procedure
Using the following spectrum analyzer settings:
1. Span= approximately 2 to 3 times the 20dB bandwidth, centered on a hopping channel.
2. Set the RBW = 30 kHz.
3. Set the VBW = 100 kHz.
4. Sweep time = auto couple.
5. Detector function = peak.
6. Trace mode = max hold.
7. Allow trace to fully stabilize.
6.4. Test Data
Test Item
Test Voltage
Test Result
20dB BW
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Channel
Frequency(MHz)
20dB Down BW(kHz)
Modulation Mode
Low
2402
933.4
BDR
Middle
2441
933.8
BDR
High
2480
932.3
BDR
Low
2402
1267.0
EDR
Middle
2441
1266.0
EDR
High
2480
1265.0
EDR
Remark: The EDR was tested on (π/4DQPSK, 8DPSK) modes, only the worst data of (8DPSK) is attached in the
following pages.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 31 of 63 Report No.: R0217060020W1
Test Mode: BDR---Low
Test Mode: BDR---Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 32 of 63 Report No.: R0217060020W1
Test Mode: BDR---High
Test Mode: EDR---Low
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 33 of 63 Report No.: R0217060020W1
Test Mode: EDR---Middle
Test Mode: EDR---High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 34 of 63 Report No.: R0217060020W1
7. Carrier Frequency Separation Test
7.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (a)(1)
Test Limit
>25KHz or >two-thirds of the 20 dB bandwidth
7.2. Test Setup
7.3. Test Procedure
The EUT must have its hopping function enabled. Using the following spectrum analyzer settings:
1. Span= Wide enough to capture the peaks of two adjacent channels
2. Set the RBW = 30 kHz.
3. Set the VBW = 100 kHz.
4. Sweep time = auto couple.
5. Detector function = peak.
6. Trace mode = max hold.
7. Allow trace to fully stabilize.
7.4. Test Data
Test Item
Test Voltage
Test Result
Frequency Separation
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Channel
Frequency
(MHz)
Separation Read
Value (kHz)
Limit
(kHz)
Modulation
Mode
Low
2402
1000
933.4
BDR
Middle
2441
1000
933.8
BDR
High
2480
1000
932.3
BDR
Low
2402
1000
844.7
EDR
Middle
2441
1000
844.0
EDR
High
2480
1000
843.3
EDR
Remark:
1. The limit of mode (EDR) is 2/3 of 20dB BW;
2. The EDR was tested on (π/4DQPSK, 8DPSK) modes, only the worst data of (8DPSK) is attached in the
following pages.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 35 of 63 Report No.: R0217060020W1
Test Mode: BDR---Low
Test Mode: BDR---Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 36 of 63 Report No.: R0217060020W1
Test Mode: BDR---High
Test Mode: EDR---Low
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 37 of 63 Report No.: R0217060020W1
Test Mode: EDR---Middle
Test Mode: EDR---High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 38 of 63 Report No.: R0217060020W1
8. Number of Hopping Channel Test
8.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (a)(1)
Test Limit
>15 channels
8.2. Test Setup
8.3. Test Procedure
The EUT must have its hopping function enabled. Using the following spectrum analyzer setting:
1. Span= the frequency band of operation
2. Set the RBW = 100kHz.
3. Set the VBW = 300kHz.
4. Sweep time = auto couple.
5. Detector function = peak.
6. Trace mode = max hold.
7. Allow trace to fully stabilize.
8.4. Test Data
Test Item
Test Voltage
Test Result
Number of Hopping Frequency
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Hopping Channel Frequency
Range
Quantity of Hopping Channel
Quantity of Hopping Channel
2402-2480MHz
79
>15
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 39 of 63 Report No.: R0217060020W1
BDR Mode
EDR Mode
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 40 of 63 Report No.: R0217060020W1
9. Dwell Time Test
9.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (a)(1)
Test Limit
0.4 sec
9.2. Test Setup
9.3. Test Procedure
The EUT must have its hopping function enabled. Use the following spectrum analyzer settings:
1. Span= zero span, centered on a hopping channel
2. Set the RBW = 1 MHz.
3. Set the VBW = 1 MHz.
4. Sweep time = as necessary to capture the entire dwell time per hopping channel.
5. Detector function = peak.
6. Trace mode = max hold.
7. Allow trace to fully stabilize.
9.4. Test Data
Test Item
Test Voltage
Test Result
Time of Occupancy
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Package
Type
Pulse width
(ms)
Time slot length(ms)
Dwell time
(ms)
Limit (s)
Modulation
DH1
0.368
time slot length *1600/2 /79 * 31.6
117.76
0.4
BDR
DH3
1.620
time slot length *1600/4 /79 * 31.6
259.20
0.4
BDR
DH5
2.867
time slot length *1600/6 /79 * 31.6
305.81
0.4
BDR
3DH1
0.375
time slot length *1600/2 /79 * 31.6
120.00
0.4
EDR
3DH3
1.620
time slot length *1600/4 /79 * 31.6
259.20
0.4
EDR
3DH5
2.873
time slot length *1600/6 /79 * 31.6
306.45
0.4
EDR
Remark: The EDR was tested on ( π/4DQPSK, 8DPSK) modes, only the worst data of (8DPSK) is attached in the following
pages.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 41 of 63 Report No.: R0217060020W1
Test Mode: BDR---DH1
Test Mode: BDR---DH3
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 42 of 63 Report No.: R0217060020W1
Test Mode: BDR—DH5
Test Mode: EDR---3DH1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 43 of 63 Report No.: R0217060020W1
Test Mode: EDR---3DH3
Test Mode: EDR—3DH5
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 44 of 63 Report No.: R0217060020W1
10. 100kHz Bandwidth of Frequency Band Edge Requirement
10.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (d)
Test Limit
in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum
intentional radiator in operating, the radio frequency power that is produced by the
intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within
the band that contains the highest level of the desired power, In addition, radiated
emissions which fall in the restricted bands, as defined in §15.205(a), must also
comply with the radiated emission limits specified in 15.209(a).
10.2. Test Setup
10.3. Test Procedure
The EUT must have its hopping/Non-hopping function enabled. Using the following spectrum analyzer setting:
1. Set the RBW = 100kHz.
2. Set the VBW = 300kHz.
3. Sweep time = auto couple.
4. Detector function = peak.
5. Trace mode = max hold.
6. Allow trace to fully stabilize.
10.4. Test Data
Test Item
Test Voltage
Test Result
Band edge
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Remark: The EDR was tested on (GFSK, π/4DQPSK, 8DPSK) modes, only the worst data of (π/4DQPSK) is
attached in the following pages.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 45 of 63 Report No.: R0217060020W1
For Hopping Mode
BDR mode
EDR mode
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 46 of 63 Report No.: R0217060020W1
For Non-Hopping Mode
BDR mode -- Lowest
BDR mode -- Highest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 47 of 63 Report No.: R0217060020W1
For Non-Hopping Mode
EDR mode -- Lowest
EDR mode -- Highest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 48 of 63 Report No.: R0217060020W1
Conducted Emission Method
Test Mode: BDR---Low
Test Mode: BDR---Mid
Test Mode: BDR---High
Test Mode: EDR---Low
Test Mode: EDR---Mid
Test Mode: EDR---High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 49 of 63 Report No.: R0217060020W1
11. Antenna Requirement
11.1. Test Standard and Requirement
Test Standard
FCC Part15 Section 15.203 /247(c)
Requirement
1) 15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished
by the responsible party shall be used with the device.
The use of a permanently
attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the
manufacturer may design the unit so that a broken antenna can be replaced by the user, but
the use of a standard antenna jack or electrical connector is prohibited.
2) 15.247(c) (1)(i) requirement:
Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed.
Point-to-point operations may employ transmitting antennas with directional gain greater
than 6dBi provided the maximum conducted output power of the intentional radiator is
reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6 dBi.
11.2. Antenna Connected Construction
The bluetooth antenna is PCB antenna which permanently attached, and the best case gain of the antenna is 1.0dBi.
It complies with the standard requirement.
BT Antenna
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 50 of 63 Report No.: R0217060020W1
APPENDIX I -- TEST SETUP PHOTOGRAPH
Photo of Conducted Emission Measurement
Photo of Radiation Emission Test
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 51 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 52 of 63 Report No.: R0217060020W1
APPENDIX II -- EXTERNAL PHOTOGRAPH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 53 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 54 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 55 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 56 of 63 Report No.: R0217060020W1
APPENDIX III -- INTERNAL PHOTOGRAPH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 57 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 58 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 59 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 60 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 61 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 62 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page 63 of 63 Report No.: R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Download: COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Mirror Download [FCC.gov]COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Document ID3556462
Application IDehqpj/9NvUJEyoL8qUEzhg==
Document DescriptionRF Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize335.61kB (4195094 bits)
Date Submitted2017-09-12 00:00:00
Date Available2017-09-12 00:00:00
Creation Date2017-09-05 16:58:00
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2017-09-05 16:59:00
Document TitleTest Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Administrator
Create Date                     : 2017:09:05 16:58:00+08:00
Modify Date                     : 2017:09:05 16:59:00+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:09:05 16:59+08:00
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Format                          : application/pdf
Title                           : <5C5C3139322E3136382E322E3130325CCAB5D1E9CAD25C215246CAC2D2B5B2BF5C323031372050726F6A6563745C36D4C25C303231373036303032305720D6DCCEE420D6C7C4DCBFD5B5F7A3A8B7D6C0EBCABDA3A920434F4F4C2D5038303020D1EED5F1D3EE2DC0EEC4DC2D4643432D49445C523032313
Creator                         : Administrator
Document ID                     : uuid:9b1b7c07-0244-4256-a985-ecd8303cae90
Instance ID                     : uuid:886e56e5-6629-461c-b461-39d600d44de3
Page Count                      : 63