COOL-P800 Mini-split air conditioner Test Report 3B TECH Inc

3B TECH Inc Mini-split air conditioner

FCC ID Filing: 2ANDE-COOL-P800
Purchase on Amazon: Mini-split air conditioner

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 2 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 3 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 4 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 5 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 6 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 7 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 8 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 9 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 10 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 11 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 12 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 13 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 14 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 15 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 16 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 17 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 18 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 19 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 20 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 21 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 22 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 23 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 24 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 25 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 26 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 27 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 28 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 29 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 30 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 31 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 32 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 33 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 34 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 35 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 36 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 37 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 38 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 39 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 40 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 41 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Page 42 of COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc

Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page1 of 42 Report No.: R0217060020W2
FCC TEST REPORT
For
3B TECH Inc
Mini-split air conditioner
Model No.: COOL-P800
Prepared For
: 3B TECH Inc
Address
: 3431 William Richardson Dr., South Bend, IN 46628
Prepared By
: Shenzhen Anbotek Compliance Laboratory Limited
Address
: 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, Nanshan
District, Shenzhen, Guangdong, China
Tel: (86) 755-26066544
Report Number
: R0217060020W2
Date of Test
: Jun. 02~Jul. 04, 2017
Date of Report
: Jul. 04, 2017
Fax: (86) 755-26014772
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page2 of 42 Report No.: R0217060020W2
Contents
1. General Information..................................................................................................................................................5
1.1. Client Information......................................................................................................................................... 5
1.2. Description of Device (EUT)........................................................................................................................ 5
1.3. Auxiliary Equipment Used During Test........................................................................................................ 5
1.4. Description of Test Modes.............................................................................................................................6
1.5. List of channels..............................................................................................................................................6
1.6. Description Of Test Setup..............................................................................................................................7
1.7. Test Equipment List....................................................................................................................................... 8
1.8. Measurement Uncertainty..............................................................................................................................8
1.9. Description of Test Facility........................................................................................................................... 9
2. Summary of Test Results........................................................................................................................................ 10
3. Conducted Emission Test........................................................................................................................................11
3.1. Test Standard and Limit...............................................................................................................................11
3.2. Test Setup.....................................................................................................................................................11
3.3. Test Procedure..............................................................................................................................................11
3.4. Test Data...................................................................................................................................................... 11
4. Radiation Spurious Emission and Band Edge........................................................................................................ 16
4.1. Test Standard and Limit...............................................................................................................................16
4.2. Test Setup.....................................................................................................................................................16
4.3. Test Procedure..............................................................................................................................................17
4.4. Test Data...................................................................................................................................................... 18
5. Maximum Peak Output Power Test........................................................................................................................25
5.1. Test Standard and Limit...............................................................................................................................25
5.2. Test Setup.....................................................................................................................................................25
5.3. Test Procedure..............................................................................................................................................25
5.4. Test Data...................................................................................................................................................... 25
6. 6DB Occupy Bandwidth Test................................................................................................................................. 28
6.1. Test Standard and Limit...............................................................................................................................28
6.2. Test Setup.....................................................................................................................................................28
6.3. Test Procedure..............................................................................................................................................28
6.4. Test Data...................................................................................................................................................... 28
7. Power Spectral Density Test................................................................................................................................... 31
7.1. Test Standard and Limit...............................................................................................................................31
7.2. Test Setup.....................................................................................................................................................31
7.3. Test Procedure..............................................................................................................................................31
7.4. Test Data...................................................................................................................................................... 31
8. 100kHz Bandwidth of Frequency Band Edge Requirement.................................................................................. 34
8.1. Test Standard and Limit...............................................................................................................................34
8.2. Test Setup.....................................................................................................................................................34
8.3. Test Procedure..............................................................................................................................................34
8.4. Test Data...................................................................................................................................................... 34
9. Antenna Requirement............................................................................................................................................. 36
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page3 of 42 Report No.: R0217060020W2
9.1. Test Standard and Requirement................................................................................................................... 38
9.2. Antenna Connected Construction................................................................................................................ 38
APPENDIX I -- TEST SETUP PHOTOGRAPH....................................................................................................... 39
APPENDIX II -- EXTERNAL PHOTOGRAPH....................................................................................................... 41
APPENDIX III -- INTERNAL PHOTOGRAPH.......................................................................................................42
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page4 of 42 Report No.: R0217060020W2
TEST REPORT
Applicant
: 3B TECH Inc
Manufacturer
: 3B TECH Inc
Product Name
: Mini-split air conditioner
Model No.
: COOL-P800
Trade Mark
: rollibot
Rating(s)
: Input: AC 120-240V, 50/60Hz, 13A, 1560W
Test Standard(s)
FCC Part15 Subpart C 2016, Section 15.247
Test Method(s)
ANSI C63.10: 2013, KDB558074 D01 DTS Meas Guidance v04
The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the
maximum emission levels emanating from the device and the severe levels of the device can endure and its
performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek
Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these
measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the
FCC Part 15 Subpart C requirements.
This report applies to above tested sample only and shall not be reproduced in part without written approval of
Shenzhen Anbotek Compliance Laboratory Limited.
Date of Test :
Jun. 02~Jul. 04, 2017
Prepared by :
(Tested Engineer / Winkey Wang)
Reviewer :
(Project Manager / Dolly Mo)
Approved & Authorized Signer :
(Manager / Tom Chen)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page5 of 42 Report No.: R0217060020W2
1. General Information
1.1. Client Information
Applicant
3B TECH Inc
Address
3431 William Richardson Dr., South Bend, IN 46628
Manufacturer
3B TECH Inc
Address
3431 William Richardson Dr., South Bend, IN 46628
1.2. Description of Device (EUT)
Product Name
Mini-split air conditioner
Model No.
COOL-P800
Trade Mark
N.A.
Test Power Supply
AC 120V, 60Hz/AC 240V, 60Hz
Product
Description
Operation Frequency:
WiFi 2.4G 802.11b/ g/ n(HT20) 2412-2462MHz
WiFi 2.4G 802.11n(HT40) 2422-2452MHz
BT 3.0: 2402MHz~2480MHz
BT 4.0: 2402MHz~2480MHz
Number of Channel:
WiFi 2.4G: 11 Channels for 802.11b/ g/ n(HT20)
WiFi 2.4G: 7 Channels for 802.11n(HT40)
BT 4.0: 40 Channels
Modulation Type:
WiFi 2.4G: 802.11b CCK; 802.11g/n OFDM
BT 3.0: GFSK, π/4-DQPSK, 8-DPSK
BT 4.0: GFSK
Antenna Type:
PCB Antenna
Antenna Gain(Peak):
1.0 dBi
Remark: 1)For a more detailed features description, please refer to the manufacturer’s specifications or the
User’s Manual.
2)This report is for BT 4.0
1.3. Auxiliary Equipment Used During Test
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page6 of 42 Report No.: R0217060020W2
1.4. Description of Test Modes
To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning
tested base on the consideration of following EUT operation mode or test configuration mode which possible have
effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned
above was evaluated respectively.
Pretest Mode
Description
Mode 1
CH00
Mode 2
CH19
Mode 3
CH39
Mode 4
Keeping TX mode
For Conducted Emission
Final Test Mode
Description
Mode 4
Keeping TX mode
For Radiated Emission
Final Test Mode
Description
Mode 1
CH00
Mode 2
CH19
Mode 3
CH39
Note:
(1) The measurements are performed at the highest, middle, lowest available channels.
(2)The data rate was set in 1Mbps for radiated emission due to the highest RF output power.
1.5. List of channels
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
Channel
Freq.
(MHz)
00
2402
09
2420
18
2438
27
2456
36
2474
01
2404
10
2422
19
2440
28
2458
37
2476
02
2406
11
2424
20
2442
29
2460
38
2478
03
2408
12
2426
21
2444
30
2462
39
2480
04
2410
13
2428
22
2446
31
2464
05
2412
14
2430
23
2448
32
2466
06
2414
15
2432
24
2450
33
2468
07
2416
16
2434
25
2452
34
2470
08
2418
17
2436
26
2454
35
2472
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page7 of 42 Report No.: R0217060020W2
1.6. Description Of Test Setup
CE
E-1
EUT
AC Line
0.8m
Table
Table
1.5m
RE
E-1
EUT
0.8m
Table
1.5m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
LISN
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page8 of 42 Report No.: R0217060020W2
1.7. Test Equipment List
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal.
Interval
1.
L.I.S.N.
Artificial Mains
Network
Rohde & Schwarz
ENV216
100055
May 27, 2017
1 Year
2.
EMI Test Receiver
Rohde & Schwarz
ESCI
100627
May 27, 2017
1 Year
3.
RF Switching Unit
Compliance
Direction
RSU-M2
38303
May 27, 2017
1 Year
4.
Spectrum Analysis
Agilent
E4407B
US39390582
May 27, 2017
1 Year
5.
Preamplifier
SKET Electronic
BK1G18G30
KD17503
May 27, 2017
1 Year
6.
EMI Test Receiver
Rohde & Schwarz
ESPI
101604
May 27, 2017
1 Year
7.
Double Ridged Horn
Antenna
Instruments
corporation
GTH-0118
351600
May 31, 2017
1 Year
8.
Bilog Broadband
Antenna
Schwarzbeck
VULB9163
VULB 9163-289
May 31, 2017
1 Year
9.
Loop Antenna
Schwarzbeck
HFH2-Z2
100047
Apr. 03, 2017
1 Year
10.
Pre-amplifier
SONOMA
310N
186860
May 27, 2017
1 Year
11.
EMI Test Software
EZ-EMC
SHURPLE
N/A
N/A
N/A
N/A
12.
Power Sensor
DAER
RPR3006W
15I00041SN045
May 27, 2017
1 Year
13.
Power Sensor
DAER
RPR3006W
15I00041SN046
May 27, 2017
1 Year
14.
MXA Spectrum
Analysis
Agilent
N9020A
MY51170037
May 27, 2017
1 Year
15.
MXG RF Vector
Signal Generator
Agilent
N5182A
MY48180656
May 27, 2017
1 Year
16.
Signal Generator
Agilent
E4421B
MY41000743
May 27, 2017
1 Year
17.
DC Power supply
IVYTECH
IV6003
1601D6030007
May 26, 2017
1 Year
18.
TEMP&HUMI
PROGRAMMABLE
CHAMBER
Sertep
ZJ-HWHS80
ZJ-17042804
Mar. 03, 2017
1 Year
1.8. Measurement Uncertainty
Radiation Uncertainty
Ur = 4.1 dB (Horizontal)
Ur = 4.3 dB (Vertical)
Conduction Uncertainty
Uc = 3.4dB
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page9 of 42 Report No.: R0217060020W2
1.9. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 752021
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a
report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
maintained in our files. Registration 752021, July 06, 2016.
ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a
report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from
the ISED is maintained in our files. Registration 8058A-1, June 13, 2016.
Test Location
All Emissions tests were performed at
Shenzhen Anbotek Compliance Laboratory Limited. at 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai
Road, Nanshan District, Shenzhen, Guangdong, China
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page10 of 42 Report No.: R0217060020W2
2. Summary of Test Results
Standard Section
Test Item
Result
15.203/15.247(c)
Antenna Requirement
PASS
15.207
Conducted Emission
PASS
15.205/15.209
Spurious Emission
PASS
15.247(b)(3)
Conducted Peak Output Power
PASS
15.247(a)(2)
6dB Occupied Bandwidth
PASS
15.247(e)
Power Spectral Density
PASS
15.247(d)
Band Edge
PASS
Remark: “N/A” is an abbreviation for Not Applicable.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page11 of 42 Report No.: R0217060020W2
3. Conducted Emission Test
3.1. Test Standard and Limit
Test Standard
FCC Part15 Section 15.207
Frequency
Test Limit
Maximum RF Line Voltage (dBuV)
Quasi-peak Level
Average Level
150kHz~500kHz
66 ~ 56 *
56 ~ 46 *
500kHz~5MHz
56
46
5MHz~30MHz
60
50
Remark: (1) *Decreasing linearly with logarithm of the frequency.
(2) The lower limit shall apply at the transition frequency.
3.2. Test Setup
3.3. Test Procedure
The EUT system is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This
provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and
photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the
maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed
according to FCC ANSI C63.10-2013 on Conducted Emission Measurement.
The bandwidth of test receiver (ESCI) set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.
3.4. Test Data
Please to see the following pages
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page12 of 42 Report No.: R0217060020W2
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 120V, 60Hz
Comment:
Live Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page13 of 42 Report No.: R0217060020W2
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 120V, 60Hz
Comment:
Neutral Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page14 of 42 Report No.: R0217060020W2
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 240V, 60Hz
Comment:
Live Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page15 of 42 Report No.: R0217060020W2
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX mode
Test Specification:
AC 240V, 60Hz
Comment:
Neutral Line
Tem.:25℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page16 of 42 Report No.: R0217060020W2
4. Radiation Spurious Emission and Band Edge
4.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.209 and 15.205
Test Limit
Frequency
(MHz)
Field strength
(microvolt/meter)
Limit
(dBuV/m)
Remark
Measurement
distance (m)
0.009MHz~0.490MHz
2400/F(kHz)
300
0.490MHz-1.705MHz
24000/F(kHz)
30
1.705MHz-30MHz
30
30
30MHz~88MHz
100
40.0
Quasi-peak
88MHz~216MHz
150
43.5
Quasi-peak
216MHz~960MHz
200
46.0
Quasi-peak
960MHz~1000MHz
500
54.0
Quasi-peak
500
54.0
Average
74.0
Peak
Above 1000MHz
Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the maximum permitted average
emission limit applicable to the equipment under test. This peak limit applies to the total peak emission level radiated by the device.
4.2. Test Setup
Figure 1. Below 30MHz
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page17 of 42 Report No.: R0217060020W2
Figure 2. 30MHz to 1GHz
Figure 3. Above 1 GHz
4.3. Test Procedure
For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane.
For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane.
The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3
meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and
down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes
to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The
EUT is tested in 9*6*6 Chamber. The device is evaluated in xyz orientation.
For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page18 of 42 Report No.: R0217060020W2
For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz,Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For above 1GHz,Set the spectrum analyzer as:
RBW =1MHz, VBW =1MHz, Detector= Peak, Trace mode= Max hold, Sweep- auto couple.
RBW =1MHz, VBW =10Hz, Detector= Average, Trace mode= Max hold, Sweep- auto couple.
4.4. Test Data
PASS
During the test, Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the X-axis is the worst
case.
The test results of 9kHz-30MHz and above 18000MHz are attenuated more than 20dB below the permissible
limits, so the results don't record in the report.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page19 of 42 Report No.: R0217060020W2
Test Results (30~1000MHz)
Job No.:
0217060020W
Temp.(℃)/Hum.(%RH):
24.3℃/55%RH
Standard:
FCC PART 15C
Power Source:
AC 120V, 60Hz
Test Mode:
TX Mode
Polarization:
Horizontal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page20 of 42 Report No.: R0217060020W2
Test Results (30~1000MHz)
Job No.:
0217060020W
Temp.(℃)/Hum.(%RH):
24.3℃/55%RH
Standard:
FCC PART 15C
Power Source:
AC 120V, 60Hz
Test Mode:
TX Mode
Polarization:
Vertical
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page21 of 42 Report No.: R0217060020W2
Test Results (Above 1000MHz)
Test Mode: TX Mode
Test channel: Lowest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4804.00
38.23
34.04
6.58
34.09
44.76
74.00
-29.24
7206.00
32.44
37.11
7.73
34.50
42.78
74.00
-31.22
9608.00
32.01
39.31
9.23
34.79
45.76
74.00
-28.24
12010.00
74.00
14412.00
74.00
4804.00
42.70
34.04
6.58
34.09
49.23
74.00
-24.77
7206.00
34.28
37.11
7.73
34.50
44.62
74.00
-29.38
9608.00
31.52
39.31
9.23
34.79
45.27
74.00
-28.73
12010.00
74.00
14412.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4804.00
26.87
34.04
6.58
34.09
33.40
54.00
-20.60
7206.00
21.02
37.11
7.73
34.50
31.36
54.00
-22.64
9608.00
20.04
39.31
9.23
34.79
33.79
54.00
-20.21
12010.00
54.00
14412.00
54.00
4804.00
31.20
34.04
6.58
34.09
37.73
54.00
-16.27
7206.00
23.26
37.11
7.73
34.50
33.60
54.00
-20.40
9608.00
19.85
39.31
9.23
34.79
33.60
54.00
-20.40
12010.00
54.00
14412.00
54.00
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page22 of 42 Report No.: R0217060020W2
Test Results (Above 1000MHz)
Test Mode: TX Mode
Test channel: Middle
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4884.00
37.36
34.38
6.69
34.09
44.34
74.00
-29.66
7326.00
31.87
37.22
7.78
34.53
42.34
74.00
-31.66
9768.00
31.50
39.46
9.35
34.80
45.51
74.00
-28.49
12210.00
74.00
14652.00
74.00
4884.00
41.66
34.38
6.69
34.09
48.64
74.00
-25.36
7326.00
33.63
37.22
7.78
34.53
44.10
74.00
-29.90
9768.00
30.93
39.46
9.35
34.80
44.94
74.00
-29.06
12210.00
74.00
14652.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4884.00
26.18
34.38
6.69
34.09
33.16
54.00
-20.84
7326.00
20.56
37.22
7.78
34.53
31.03
54.00
-22.97
9768.00
19.63
39.46
9.35
34.80
33.64
54.00
-20.36
12210.00
54.00
14652.00
54.00
4884.00
30.42
34.38
6.69
34.09
37.40
54.00
-16.60
7326.00
22.74
37.22
7.78
34.53
33.21
54.00
-20.79
9768.00
19.37
39.46
9.35
34.80
33.38
54.00
-20.62
12210.00
54.00
14652.00
54.00
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page23 of 42 Report No.: R0217060020W2
Test Results (Above 1000MHz)
Test Mode: TX Mode
Test channel: Highest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4960.00
36.71
34.72
6.79
34.09
44.13
74.00
-29.87
7440.00
31.44
37.34
7.82
34.57
42.03
74.00
-31.97
9920.00
31.12
39.62
9.46
34.81
45.39
74.00
-28.61
12400.00
74.00
14880.00
74.00
4960.00
40.88
34.72
6.79
34.09
48.30
74.00
-25.70
7440.00
33.14
37.34
7.82
34.57
43.73
74.00
-30.27
9920.00
30.49
39.62
9.46
34.81
44.76
74.00
-29.24
12400.00
74.00
14880.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4960.00
25.71
34.72
6.79
34.09
33.13
54.00
-20.87
7440.00
20.24
37.34
7.82
34.57
30.83
54.00
-23.17
9920.00
19.35
39.62
9.46
34.81
33.62
54.00
-20.38
12400.00
54.00
14880.00
54.00
4960.00
29.88
34.72
6.79
34.09
37.30
54.00
-16.70
7440.00
22.38
37.34
7.82
34.57
32.97
54.00
-21.03
9920.00
19.03
39.62
9.46
34.81
33.30
54.00
-20.70
12400.00
54.00
14880.00
54.00
Remark:
1. Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. “*”, means this data is the too weak instrument of signal is unable to test.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page24 of 42 Report No.: R0217060020W2
Radiated Band Edge:
Test Mode: GFSK
Test channel: Lowest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
44.52
29.15
3.41
34.01
43.07
74.00
-30.93
2400.00
61.54
29.16
3.43
34.01
60.12
74.00
-13.88
2390.00
45.22
29.15
3.41
34.01
43.77
74.00
-30.23
2400.00
63.75
29.16
3.43
34.01
62.33
74.00
-11.67
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
34.70
29.15
3.41
34.01
33.25
54.00
-20.75
2400.00
46.03
29.16
3.43
34.01
44.61
54.00
-9.39
2390.00
34.76
29.15
3.41
34.01
33.31
54.00
-20.69
2400.00
47.84
29.16
3.43
34.01
46.42
54.00
-7.58
Test Mode: GFSK
Test channel: Highest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
46.82
29.28
3.53
34.03
45.60
74.00
-28.40
2500.00
45.68
29.30
3.56
34.03
44.51
74.00
-29.49
2483.50
47.94
29.28
3.53
34.03
46.72
74.00
-27.28
2500.00
46.83
29.30
3.56
34.03
45.66
74.00
-28.34
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
37.55
29.28
3.53
34.03
36.33
54.00
-17.67
2500.00
35.31
29.30
3.56
34.03
34.14
54.00
-19.86
2483.50
38.89
29.28
3.53
34.03
37.67
54.00
-16.33
2500.00
35.37
29.30
3.56
34.03
34.20
54.00
-19.80
Remark:
1. Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page25 of 42 Report No.: R0217060020W2
5. Maximum Peak Output Power Test
5.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (b)(3)
Test Limit
30dBm
5.2. Test Setup
5.3. Test Procedure
This procedure shall be used when the measurement instrument has available a resolution bandwidth that is
greater than the DTS bandwidth.
1. Set the RBW ≥DTS bandwidth.
2. Set the VBW≥3*RBW.
3. Set the span≥ 3*RBW.
4. Detector = peak.
5. Sweep time = auto couple.
6. Trace mode = max hold.
7. Allow trace to fully stabilize.
8. Use peak marker function to determine the peak amplitude level.
5.4. Test Data
Test Item
Test Voltage
Test Result
Max. peak output power
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Channel Frequency
(MHz)
Peak Power output
(dBm)
Limit
(dBm)
Results
2402
-5.607
30
PASS
2440
-5.530
30
PASS
2480
-4.865
30
PASS
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page26 of 42 Report No.: R0217060020W2
CH: Low
CH: Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page27 of 42 Report No.: R0217060020W2
CH: High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page28 of 42 Report No.: R0217060020W2
6. 6DB Occupy Bandwidth Test
6.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (a)(2)
Test Limit
>500kHz
6.2. Test Setup
6.3. Test Procedure
1. Place the EUT on the table and set it in the transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum
analyzer.
3. Set the spectrum analyzer as:
RBW = 100kHz, VBW≥3*RBW =300kHz,
Detector= Peak
Trace mode= Max hold.
Sweep- auto couple.
4. Mark the peak frequency and –6dB (upper and lower) frequency.
5. Repeat until all the rest channels are investigated.
6.4. Test Data
Test Item
Test Voltage
Test Result
6dB Bandwidth
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
Channel
Frequency(MHz)
Bandwidth (kHz)
Low
2402
687.5
Middle
2440
689.4
High
2480
690.8
Limit
(kHz)
CH Low ~ CH High
24℃
55%RH
Results
PASS
>500
PASS
PASS
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page29 of 42 Report No.: R0217060020W2
CH: Low
CH: Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page30 of 42 Report No.: R0217060020W2
CH: High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page31 of 42 Report No.: R0217060020W2
7. Power Spectral Density Test
7.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (e)
Test Limit
8dBm
7.2. Test Setup
7.3. Test Procedure
1. Place the EUT on the table and set it in transmitting mode. Remove the antenna from the EUT and then connect
a low loss RF cable from the antenna port to the spectrum analyzer.
2. Set the spectrum analyzer as RBW = 3kHz, VBW = 10kHz, Span = 1.5xDTS BW
3. Record the max. reading.
4. Repeat the above procedure until the measurements for all frequencies are completed.
7.4. Test Data
Test Item
Test Voltage
Test Result
Power Spectral Density
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Channel
Frequency
(MHz)
PPSD
(dBm/3KHz)
Limit
(dBm/3KHz)
Results
Low
2402
-20.786
8.00
PASS
Middle
2440
-20.675
8.00
PASS
High
2480
-20.053
8.00
PASS
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page32 of 42 Report No.: R0217060020W2
CH: Low
CH: Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page33 of 42 Report No.: R0217060020W2
CH: High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page34 of 42 Report No.: R0217060020W2
8. 100kHz Bandwidth of Frequency Band Edge Requirement
8.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (d)
Test Limit
in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum
intentional radiator in operating, the radio frequency power that is produced by the
intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within
the band that contains the highest level of the desired power, In addition, radiated
emissions which fall in the restricted bands, as defined in §15.205(a), must also
comply with the radiated emission limits specified in15.209(a).
8.2. Test Setup
8.3. Test Procedure
Using the following spectrum analyzer setting:
1. Set the RBW = 100KHz.
2. Set the VBW = 300KHz.
3. Sweep time = auto couple.
4. Detector function = peak.
5. Trace mode = max hold.
6. Allow trace to fully stabilize.
8.4. Test Data
Test Item
Test Voltage
Test Result
Band edge
AC 120V, 60Hz
PASS
Test Mode
Temperature
Humidity
CH Low ~ CH High
24℃
55%RH
Frequency Band
(MHz)
Delta Peak toBand Emission
(dBc)
Limit
(dBc)
Results
2400
57.544
>20
PASS
2483.5
60.573
>20
PASS
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page35 of 42 Report No.: R0217060020W2
CH: Low
CH: High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page36 of 42 Report No.: R0217060020W2
Conducted Emission Method
CH: Low
CH: Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page37 of 42 Report No.: R0217060020W2
CH: High
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page38 of 42 Report No.: R0217060020W2
9. Antenna Requirement
9.1. Test Standard and Requirement
Test Standard
FCC Part15 Section 15.203 /247(c)
Requirement
1) 15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished
by the responsible party shall be used with the device.
The use of a permanently
attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the
manufacturer may design the unit so that a broken antenna can be replaced by the user, but
the use of a standard antenna jack or electrical connector is prohibited.
2) 15.247(c) (1)(i) requirement:
Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed.
Point-to-point operations may employ transmitting antennas with directional gain greater
than 6dBi provided the maximum conducted output power of the intentional radiator is
reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6 dBi.
9.2. Antenna Connected Construction
The bluetooth antenna is a PCB antenna which permanently attached, and the best case gain of the antenna is 1dBi.
It complies with the standard requirement.
BT Antenna
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page39 of 42 Report No.: R0217060020W2
APPENDIX I -- TEST SETUP PHOTOGRAPH
Photo of Conducted Emission Measurement
Photo of Radiation Emission Test
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page40 of 42 Report No.: R0217060020W2
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page41 of 42 Report No.: R0217060020W2
APPENDIX II -- EXTERNAL PHOTOGRAPH
Please see the test report of R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2ANDE-COOL-P800 Page42 of 42 Report No.: R0217060020W2
APPENDIX III -- INTERNAL PHOTOGRAPH
Please see the test report of R0217060020W1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544
Fax:(86)755-26014772
www.anbotek.com
Download: COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Mirror Download [FCC.gov]COOL-P800 Mini-split air conditioner Test Report  3B TECH Inc
Document ID3556525
Application IDjocHcgqZe7ufKsLqHEmaoA==
Document DescriptionRF Test Report-BLE
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize121.39kB (1517432 bits)
Date Submitted2017-09-12 00:00:00
Date Available2017-09-12 00:00:00
Creation Date2017-09-08 11:49:05
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2017-09-08 11:49:39
Document TitleTest Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Administrator
Create Date                     : 2017:09:08 11:49:05+08:00
Modify Date                     : 2017:09:08 11:49:39+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:09:08 11:49:39+08:00
Format                          : application/pdf
Title                           : <5C5C3139322E3136382E322E3130325CCAB5D1E9CAD25C215246CAC2D2B5B2BF5C323031372050726F6A6563745C36D4C25C303231373036303032305720D6DCCEE420D6C7C4DCBFD5B5F7A3A8B7D6C0EBCABDA3A920434F4F4C2D5038303020D1EED5F1D3EE2DC0EEC4DC2D4643432D49445C523032313
Creator                         : Administrator