X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited

Planet Computers Limited Gemini 4G

Page 1 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 2 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 3 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 4 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 5 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 6 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 7 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 8 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 9 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 10 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 11 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 12 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 13 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 14 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 15 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 16 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 17 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 18 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 19 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 20 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 21 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 22 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 23 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 24 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 25 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 26 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 27 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 28 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 29 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 30 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Page 31 of X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited

AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
5-1
5. 99% & 26dB Occupied Bandwidth Test
5.1.Test Equipment
Item
1.
2.
3.
Equipment
Manufacturer
Model No.
Serial No.
PXA Signal
Agilent
N9030A
MY53311015
Analyzer
Attenuator (20dB)
Agilent
8491B
MY39262165
Marvelous
RF Cable
SFL402105FLEX
NO.1
Microwave Inc
Last Cal.
Cal. Interval
Oct.15,17
1 Year
Apr.27,17
1 Year
Oct.15,17
1 Year
5.2.Test Procedure
The EUT output RF connector was connected with a short a cable to the spectrum analyzer,
RBW was set to about 1% of emission BW, VBW>=3 times RBW, 99% bandwidth were
measured, the occupied bandwidth is the delta frequency between the two points where the
display line intersects the signal trace.
5.3.Test Result
99% Bandwidth
EUT: Gemini
M/N: Gemini 4G
Test date: 2018-01-02~03
Tested by: Alice_Yang
Pressure: 102.7±1.0 kpa
Test site: RF site
Humidity: 52.8±3.0%
Temperature:22.2±0.6 ℃
99% bandwidth
Test Mode
GSM 850
PCS 1900
CH
Frequency
(MHz)
(kHz)
TM 1
TM 2
Limit
(KHz)
CH128
824.2
246.78
240.02
N/A
CH190
836.6
249.08
245.92
N/A
CH251
848.8
246.36
239.23
N/A
CH512
1850.2
246.17
250.63
N/A
CH661
1880
244.43
246.10
N/A
CH810
1909.8
241.80
249.76
N/A
Conclusion:PASS
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
EUT: Gemini
M/N: Gemini 4G
Test date: 2018-01-02~03
Tested by: Alice_Yang
Pressure: 102.7±1.0 kpa
Test site: RF site
5-2
Humidity: 52.8±3.0%
Temperature:22.2±0.6 ℃
26dB bandwidth
Test Mode
GSM 850
GSM 1900
CH
Frequency
(MHz)
(kHz)
TM 1
TM 2
Limit
(KHz)
CH128
824.2
322.0
307.6
N/A
CH190
836.6
322.3
324.6
N/A
CH251
848.8
320.2
294.4
N/A
CH512
1850.2
324.5
318.7
N/A
CH661
1880
324.2
311.8
N/A
CH810
1909.8
318.5
320.3
N/A
Conclusion:PASS
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
5-3
GSM 850
TM 1
CH128
CH190
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
5-4
CH251
TM 2
CH128
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
5-5
CH190
CH251
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
5-6
PCS 1900
TM 1
CH512
CH661
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
5-7
CH810
TM 2
CH512
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
5-8
CH661
CH810
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
6-1
6. RF POWER OUTPUT TEST
6.1.Test Equipment
Item
1.
2.
3.
4.
5.
Equipment
PXA Signal
Analyzer
Power meter
Manufacturer
Model No.
Serial No.
Last Cal.
Cal. Interval
Agilent
N9030A
MY53311015
Oct.15,17
1 Year
Anritsu
ML2487A
6K00002472
Apr.22,17
1Year
Power sensor
Attenuator
(20dB)
Anritsu
MA2491A
0033005
Apr.22,17
1Year
Agilent
8491B
MY39262165
Apr.22,17
1 Year
NO.1
Oct.15,17
1 Year
RF Cable
Marvelous
SFL402105FLEX
Microwave Inc
6.2.Limit
1. Part 22.913(a) Mobile station are limited to 7W and for Conducted Power we can use
antenna Gain to calculate the limit, so the Conducted Power:
Pcod. (dBm)=EIRP(dBm)-Gain(dBi)
=7W(38.5dBm)-(3.15dBi-2.15dBi)
=37.5dBm
2. Part 24.232(b) Peak power measurement, Mobile station are limited to 2W and for
conducted Power we can use antenna Gain to calculate the limit, so the
Conducted Power:
Pcod. (dBm)=EIRP(dBm)-Gain(dBi)
=2W(33dBm)-3.15(dBi)
=29.85dBm
6.3.Test Procedure
The transmitter output was connected to calibrated attenuator, the other end of which was
connected to a power meter. Transmitter output was read off the power in dBm. The power
output at the transmitter antenna port was determined by adding the value of attenuator to
the power meter reading.
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
6-2
6.4.Test Result
EUT: Gemini
M/N: Gemini 4G
Test date: 2017-12-28
Tested by: Alice_Yang
Mode
GSM
850
PCS
1900
Pressure: 102.1±1.0 kpa
Test site: RF site
Humidity: 53.2±3.0%
Temperature:22.4±0.6 ℃
Channel
TM1
TM2
Limit
128
33.5
30.4
37.5
190
33.3
30.3
37.5
251
33.3
30.3
37.5
512
29.6
27.6
29.85
661
29.5
27.6
29.85
810
29.5
27.5
29.85
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-1
7. PEAK-TO-AVERAGE POWER RATIO TEST
7.1.Test Equipment
Item
1.
2.
3.
4.
5.
Equipment
PXA Signal
Analyzer
Power meter
Manufacturer
Model No.
Serial No.
Last Cal.
Cal. Interval
Agilent
N9030A
MY53311015
Oct.15,17
1 Year
Anritsu
ML2487A
6K00002472
Apr.22,17
1Year
Power sensor
Attenuator
(20dB)
Anritsu
MA2491A
0033005
Apr.22,17
1Year
Agilent
8491B
MY39262165
Apr.22,17
1 Year
NO.1
Oct.15,17
1 Year
RF Cable
Marvelous
SFL402105FLEX
Microwave Inc
7.2.Limit
FCC Part 24.232:
(a) Power measurements for transmissions by stations authorized under this section may be
made either in accordance with a Commission-approved average power technique or in
compliance with paragraph (e) of this section. In both instances, equipment employed
must be authorized in accordance with the provisions of §24.51. In measuring
transmissions in this band using an average power technique, the peak-to-average ratio
(PAR) of the transmission may not exceed 13 dB.
(b) Peak transmit power must be measured over any interval of continuous transmission
using instrumentation calibrated in terms of an rms-equivalent voltage. The
measurement results shall be properly adjusted for any instrument limitations, such as
detector response times, limited resolution bandwidth capability when compared to the
emission bandwidth, sensitivity, etc., so as to obtain a true peak measurement for the
emission in question over the full bandwidth of the channel.
7.3.Test Procedure
According to KDB 971168:
a) Refer to instrument’s analyzer instruction manual for details on how to use the power
statistics/CCDF function;
b) Set resolution/measurement bandwidth ≥ signal’s occupied bandwidth;
c) Set the number of counts to a value that stabilizes the measured CCDF curve;
d) Set the measurement interval to 1 ms
e) Record the maximum PAPR level associated with a probability of 0.1%
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-2
7.4.Test Result
Mode
Modulation
GSM/GPRS
GSM 850
EGPRS
GSM/GPRS
PCS 1900
EGPRS
Limit
(dB)
128
Peak to Average Ratio
(PAR)
9.27
190
9.34
≤ 13
251
9.25
≤ 13
128
9.23
≤ 13
190
9.28
≤ 13
251
9.54
≤ 13
512
9.11
≤ 13
661
9.26
≤ 13
810
9.24
≤ 13
512
9.62
≤ 13
661
9.14
≤ 13
810
9.25
≤ 13
Channel
≤ 13
Conclusion:PASS
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-3
GSM 850
GPRS
CH128
CH190
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-4
CH251
EGPRS
CH128
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-5
CH190
CH251
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-6
PCS 1900
GPRS
CH512
CH661
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-7
CH810
EGPRS
CH512
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
7-8
CH661
CH810
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
8-1
page
8. FIELD STRENGTH OF RADIATED SPURIOUS EMISSIONS
8.1.Test Equipment
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal. Interval
1.
PXA Signal
Analyzer
Agilent
N9030A
MY53311015
Oct.15,17
1 Year
2.
Preamplifier
HP
8449B
3008A02495
Apr.22.17
1 Year
3.
Preamplifier
Agilent
8447D
2944A11159
Apr.22,17
1Year
4.
Trilog-Broadband
Antenna
493
Jun.27.17
1 Year
5.
Horn Antenna
ETC
May.15,17
1 Year
6.
Horn Antenna
EMCO
3116
0062643
Oct.10,17
1 Year
7.
Antenna and turn
table controller
CT
SC100
CT-0091
N/A
N/A
8.
RF Cable
Hubersuhner
SUCOFLEX1
04
274094/4
Apr.22,17
1 Year
9.
Test Software
AUDIX
e3
6.2009-5-21a(n)
N/A
N/A
SCHWARZB
VULB 9168
ECK
MCTD 1209 DRH15F03006
Note: N/A means Not applicable.
8.2.Limit
FCC part 22.917(a), 24.238(a) the magnitude of each spurious and harmonic emission that
can be detected when the equipment is operated under the conditions specification in the
instruction manual and/or alignment procedure, shall not be less than 43+10log(Mean
power in watts) dBc below the mean power output outside a license’s frequency
block(-13dBm).
8.3.Test Procedure
The EUT was placed on a non-conductive turntable using a non-conductive support. The
radiated emission at the fundamental frequency was measured at 3 m with a test antenna and
EMI spectrum analyzer. During the measurement, the EUT was communication with the
station. The highest emission was recorded with the rotation of the turntable and lowering of
the test antenna from 4m to 1m.
ERP in frequency band 824.2-848.8MHz were measured using substitution method. The
EUT was replaced by dipole antenna connected, the S.G. output was recorded and ERP was
calculated as follow: EIRP in frequency band 1850.5-1909.8MHz were measured using a
substitution method. The EUT was replaced by a horn antenna connected, the S.G. output
was recorded and EIRP was calculated as follows:
ERP=S.G. output (dBm) + Antenna Gain (dBd)-Cable Loss (dB)
EIRP=S.G. output (dBm) + Antenna Gain (dBi)-Cable Loss (dB)
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
8-2
8.4.Test Result
GSM 850
Spurious emissions
EUT: Gemini
M/N: Gemini 4G
Test Date: 2018-02-23
Test site: RF Chamber
Tested by: Alice_yang
Temperature: 22.4±0.6℃
Humidity: 52.1±3.0%
Pressure: 101.6±1.0kpa
Test result
Test Mode:GSM 850
TX CH Low Mode 824.2MHz
S.G
Antenna
Cable
Output
Gain
Loss
(dBm)
(dBi/dBd)
(dB)
-61.55
2.9
631.77
-58.51
721.18
869.13
Frequency
Antenna
Result
Limit
Margin
(MHz)
polarization
(dBm)
(dBm)
(dB)
221.32
1.42
-60.07
-13
47.07
PASS
5.2
3.14
-56.45
-13
43.45
PASS
-50.64
5.4
3.22
-48.46
-13
35.46
PASS
-20.92
5.7
3.86
-19.08
-13
6.08
PASS
1648.40
-32.60
7.9
5.68
-30.38
-13
17.38
PASS
2472.60
-37.63
7.5
7.47
-37.6
-13
24.6
PASS
3296.80
-41.73
9.6
8.74
-40.87
-13
27.87
PASS
191.21
-63.87
2.7
1.41
-62.58
-13
49.58
PASS
632.32
-61.33
5.2
3.10
-59.23
-13
46.23
PASS
745.20
-57.65
5.5
3.42
-55.57
-13
42.57
PASS
860.66
-30.21
5.7
3.71
-28.22
-13
15.22
PASS
1648.40
-33.00
7.9
5.68
-30.78
-13
17.78
PASS
2472.60
-40.31
7.5
7.47
-40.28
-13
27.28
PASS
3296.80
-42.87
9.6
8.74
-42.01
-13
29.01
PASS
Audix Technology (Shenzhen) Co., Ltd.
Conclusion
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
Test Mode:GSM 850
page
8-3
TX CH Mid Mode 836.6MHz
202.11
-58.46
2.7
1.40
-57.16
-13
44.16
PASS
642.31
-57.02
5.2
3.10
-54.92
-13
41.92
PASS
747.05
-50.62
5.5
3.45
-48.57
-13
35.57
PASS
889.03
-21.16
5.7
3.86
-19.32
-13
6.32
PASS
1673.20
-28.11
7.9
5.72
-25.93
-13
12.93
PASS
2509.80
-42.02
9.6
7.55
-39.97
-13
26.97
PASS
3346.40
-44.08
9.6
8.77
-43.25
-13
30.25
PASS
192.10
-60.89
2.7
1.35
-59.54
-13
46.54
PASS
648.98
-60.66
5.2
3.10
-58.56
-13
45.56
PASS
768.68
-55.19
5.4
3.48
-53.27
-13
40.27
PASS
882.56
-30.22
5.7
3.86
-28.38
-13
15.38
PASS
1673.20
-32.15
7.9
5.72
-29.97
-13
16.97
PASS
2509.80
-43.11
9.6
7.55
-41.06
-13
28.06
PASS
3346.40
-45.91
9.6
8.77
-45.08
-13
32.08
PASS
Test Mode:GSM 850
TX CH High Mode 848.8MHz
195.81
-54.59
2.8
1.32
-53.11
-13
40.11
PASS
659.11
-55.06
5.2
3.26
-53.12
-13
40.12
PASS
766.29
-50.51
5.4
3.53
-48.64
-13
35.64
PASS
891.06
-23.81
5.7
3.90
-22.01
-13
9.01
PASS
1697.60
-27.18
7.9
5.80
-25.08
-13
12.08
PASS
2546.40
-39.55
9.6
7.63
-37.58
-13
24.58
PASS
3395.20
-42.09
9.6
8.79
-41.28
-13
28.28
PASS
189.08
-62.82
2.6
1.34
-61.56
-13
48.56
PASS
652.16
-60.21
5.2
3.15
-58.16
-13
45.16
PASS
758.51
-55.22
5.4
3.51
-53.33
-13
40.33
PASS
896.03
-27.54
5.7
3.96
-25.8
-13
12.8
PASS
1697.60
-29.61
7.9
5.80
-27.51
-13
14.51
PASS
2546.40
-39.16
9.6
7.63
-37.19
-13
24.19
PASS
3395.20
-46.19
9.6
8.79
-45.38
-13
32.38
PASS
Remark: All the emission were detected belong to narrowband spurious emission
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
PCS 1900
Spurious emissions
EUT: Gemini
M/N: Gemini 4G
Test Date: 2018-02-23
Test site: RF Chamber
Tested by: Alice_yang
Temperature: 23.5±0.6℃
Humidity: 52.9±3.0%
Pressure: 102.4±1.0kpa
8-4
Test result
Test Mode:PCS 1900
TX CH Low Mode 1850.2MHz
S.G
Antenna
Cable
Frequency
Antenna
Output
Gain
Loss
Result
Limit
Margin
(MHz)
polarization
(dBm)
(dBi/dBd)
(dB)
(dBm)
(dBm)
(dB)
196.88
-56.07
2.7
1.38
-54.75
-13
41.75
PASS
626.52
-60.16
5.2
3.04
-58
-13
45
PASS
877.24
-62.01
5.7
3.90
-60.21
-13
47.21
PASS
959.25
-63.76
5.9
4.17
-62.03
-13
49.03
PASS
2108.00
-54.11
8.4
6.69
-52.4
-13
39.4
PASS
3264.00
-49.15
9.6
8.73
-48.28
-13
35.28
PASS
3700.40
-44.67
9.6
8.93
-44
-13
31
PASS
186.09
-61.61
2.6
1.30
-60.31
-13
47.31
PASS
633.19
-62.72
5.2
3.14
-60.66
-13
47.66
PASS
878.94
-68.89
5.7
3.87
-67.06
-13
54.06
PASS
956.15
-65.08
5.9
4.11
-63.29
-13
50.29
PASS
2108.00
-51.73
8.4
6.69
-50.02
-13
37.02
PASS
3264.00
-45.45
9.6
8.73
-44.58
-13
31.58
PASS
3700.40
-44.18
9.6
8.93
-43.51
-13
30.51
PASS
Audix Technology (Shenzhen) Co., Ltd.
Conclusion
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
Test Mode:PCS 1900
page
8-5
TX CH Mid Mode 1880.0MHz
192.94
-56.05
2.6
1.33
-54.78
-13
41.78
PASS
627.79
-60.37
5.2
3.10
-58.27
-13
45.27
PASS
878.09
-62.27
5.7
3.87
-60.44
-13
47.44
PASS
966.03
-62.32
5.9
4.19
-60.61
-13
47.61
PASS
2452.00
-51.94
9.5
7.43
-49.87
-13
36.87
PASS
2985.00
-49.81
9.6
8.56
-48.77
-13
35.77
PASS
3760.00
-44.02
9.6
8.96
-43.38
-13
30.38
PASS
190.99
-60.14
2.6
1.32
-58.86
-13
45.86
PASS
622.07
-62.59
5.2
3.01
-60.4
-13
47.4
PASS
878.34
-67.02
5.7
3.87
-65.19
-13
52.19
PASS
952.25
-65.91
5.9
4.10
-64.11
-13
51.11
PASS
2452.00
-52.16
9.5
7.43
-50.09
-13
37.09
PASS
2985.00
-51.14
9.6
8.56
-50.1
-13
37.1
PASS
3760.00
-47.27
9.6
8.96
-46.63
-13
33.63
PASS
Test Mode:PCS 1900
TX CH High Mode 1909.8MHz
194.72
-55.18
2.7
1.32
-53.8
-13
40.8
PASS
627.58
-61.92
5.2
3.09
-59.81
-13
46.81
PASS
879.13
-60.79
5.7
3.88
-58.97
-13
45.97
PASS
962.08.
-62.12
5.9
4.19
-60.41
-13
47.41
PASS
2394.00
-50.13
8.6
7.32
-48.85
-13
35.85
PASS
3108.00
-44.08
9.6
8.65
-43.13
-13
30.13
PASS
3819.60
-45.92
9.6
8.99
-45.31
-13
32.31
PASS
198.02
-58.65
2.6
1.39
-57.44
-13
44.44
PASS
623.18
-64.30
5.2
3.04
-62.14
-13
49.14
PASS
879.16
-67.66
5.7
3.87
-65.83
-13
52.83
PASS
962.73
-65.84
5.9
4.17
-64.11
-13
51.11
PASS
2394.00
-52.17
8.6
7.32
-50.89
-13
37.89
PASS
3108.00
-45.36
9.6
8.65
-44.41
-13
31.41
PASS
3819.60
-47.05
9.6
8.99
-46.44
-13
33.44
PASS
Remark: All the emission were detected belong to narrowband spurious emission
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
9.
page
9-1
FREQUENCY STABILITY V.S. TEMPERATURE AND
VOLTAGE
9.1.Test Equipment
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal. Interval
1.
PXA Signal
Analyzer
Agilent
N9030A
MY53311015
Oct.15,17
1 Year
2.
HF Cable
Hubersuhner
Sucoflex104
274094/4
Apr.22,17
1 Year
3.
Attenuator (10dB)
Mini-Circuits
VAT-10+
NO.1
NCR
NCR
4.
Temperature
controller
Terchy
MHQ-120cluB
A60223
Apr.23,17
1 Year
Note: NCR means no calibration required(calibrated with system).
9.1.Limit
Frequency Tolerance:
+/-2.5ppm for 850MHz band
+/-2.5ppm for 1900MHz band
9.2.Test procedure
The equipment under test was connected to an external DC power supply and input rated
voltage. Reference power supply voltage for these tests is DC 12V. RF output was
connected to a frequency counter or spectrum analyzer via feed through attenuators. The
EUT was placed inside the temperature chamber. Set the Spectrum analyzer RBW low
enough to obtain the desired frequency resolution and measure EUT 25 degree operating
frequency as reference frequency. Turn EUT off and set the chamber temperature to -20
degree. After the temperature stabilized for approximately 30 minutes record the frequency.
Repeat step measure with 10 degree per stage until the highest temperature of 50 degree
reached.
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
9-2
9.3.Test Result
EUT: Gemini
M/N: Gemini 4G
Test date: 2017-12-29
Tested by: Alice_Yang
Pressure: 102.5±1.0
Test site: RF site
kpa
Humidity: 52.2±3.0%
Temperature:23.1±0.6 ℃
Frequency Error vs ,Voltage
Test Band
Test Mode
Test
Channel
LCH
Test
Temp
TN
Test
Volt
Freq Error
(Hz)
Freq .vs.rated
(ppm)
Verdict
VL
15
0.018
Pass
VN
19
0.023
Pass
VH
25
10
0.030
Pass
0.012
Pass
0.013
Pass
VH
11
17
0.020
Pass
VL
13
0.015
Pass
VN
12
0.014
Pass
VH
17
0.020
Pass
VL
-23
-0.028
Pass
VN
-29
-0.035
Pass
VH
-0.038
Pass
VL
-31
-15
-0.018
Pass
VN
-18
-0.022
Pass
VH
-22
-0.026
Pass
VL
-16
-0.019
Pass
VN
-20
-0.024
Pass
VH
-23
-0.027
Pass
VL
GSM/TM1
MCH
HCH
TN
TN
GSM 850
LCH
GSM/TM2
MCH
HCH
TN
TN
TN
VN
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
9-3
Frequency Error vs ,Temperature
Test Band
Test Mode
Test
Channel
LCH
MCH
GSM 850
Test
Volt
VN
VN
GSM/TM1
HCH
VN
-30
Freq
Error
(Hz)
12
-20
11
0.013
Pass
-10
0.010
Pass
0.007
Pass
10
0.008
Pass
20
0.007
Pass
30
0.010
Pass
40
0.011
Pass
50
0.008
Pass
-30
14
0.017
Pass
-20
13
0.016
Pass
-10
14
0.017
Pass
0.010
Pass
10
0.007
Pass
20
11
0.013
Pass
30
13
0.016
Pass
40
0.011
Pass
50
12
0.014
Pass
-30
11
0.013
Pass
-20
0.011
Pass
-10
10
0.012
Pass
0.007
Pass
10
0.006
Pass
20
0.009
Pass
30
10
0.012
Pass
40
0.011
Pass
50
0.008
Pass
Test
Temp
Freq .vs.rated
(ppm)
Verdict
0.015
Pass
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
LCH
MCH
GSM 850
VN
VN
GSM/TM2
HCH
VN
-30
-23
-0.028
Pass
-20
-18
-0.022
Pass
-10
-11
-0.013
Pass
-9
-0.011
Pass
10
-8
-0.010
Pass
20
-12
-0.015
Pass
30
-14
-0.017
Pass
40
-15
-0.018
Pass
50
-14
-0.017
Pass
-30
-19
-0.023
Pass
-20
-18
-0.022
Pass
-10
-20
-0.024
Pass
-17
-0.020
Pass
10
-22
-0.026
Pass
20
-15
-0.018
Pass
30
-19
-0.023
Pass
40
-17
-0.020
Pass
50
-20
-0.024
Pass
-30
-16
-0.019
Pass
-20
-11
-0.013
Pass
-10
-5
-0.006
Pass
-14
-0.016
Pass
10
-7
-0.008
Pass
20
-9
-0.011
Pass
30
-14
-0.016
Pass
40
-12
-0.014
Pass
50
-16
-0.019
Pass
Audix Technology (Shenzhen) Co., Ltd.
9-4
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
9-5
Frequency Error vs ,Voltage
Test Band
Test Mode
Test
Channel
LCH
GSM/TM1
MCH
HCH
Test
Temp
Test
Volt
Freq Error
(Hz)
Freq .vs.rated
(ppm)
Verdict
VL
0.005
Pass
TN
VN
12
0.006
Pass
19
TN
VH
VL
VN
0.010
0.004
0.005
Pass
Pass
Pass
0.006
Pass
TN
GSM 1900
LCH
GSM/TM2
MCH
HCH
TN
TN
TN
VH
10
11
VL
0.005
Pass
VN
16
0.008
Pass
VH
19
0.010
Pass
VL
-5
-0.003
Pass
VN
-12
-0.006
Pass
VH
-0.010
Pass
VL
-18
-6
-0.003
Pass
VN
-10
-0.005
Pass
VH
-20
-0.011
Pass
VL
-2
-0.001
Pass
VN
-8
-0.004
Pass
VH
-19
-0.010
Pass
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
9-6
Frequency Error vs ,Temperature
Test Band
Test Mode
Test
Channel
LCH
MCH
GSM 1900
Test
Volt
VN
VN
GSM/TM1
HCH
VN
-30
Freq
Error
(Hz)
-15
-20
-18
-0.010
Pass
-10
-9
-0.005
Pass
-8
-0.004
Pass
10
-10
-0.005
Pass
20
-7
-0.004
Pass
30
-11
-0.006
Pass
40
-13
-0.007
Pass
50
-8
-0.004
Pass
-30
-9
-0.005
Pass
-20
-15
-0.008
Pass
-10
-6
-0.003
Pass
-5
-0.003
Pass
10
-12
-0.006
Pass
20
-18
-0.010
Pass
30
-6
-0.003
Pass
40
-9
-0.005
Pass
50
-5
-0.003
Pass
-30
-19
-0.010
Pass
-20
-8
-0.004
Pass
-10
-12
-0.006
Pass
-16
-0.008
Pass
10
-9
-0.005
Pass
20
-10
-0.005
Pass
30
-12
-0.006
Pass
40
-15
-0.008
Pass
50
-8
-0.004
Pass
Test
Temp
Freq .vs.rated
(ppm)
Verdict
-0.008
Pass
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
LCH
MCH
GSM 1900
VN
VN
GSM/TM2
HCH
VN
-30
-8
-0.004
Pass
-20
-18
-0.010
Pass
-10
-7
-0.004
Pass
-12
-0.006
Pass
10
-10
-0.005
Pass
20
-6
-0.003
Pass
30
-5
-0.003
Pass
40
-11
-0.006
Pass
50
-19
-0.010
Pass
-30
-11
-0.006
Pass
-20
-6
-0.003
Pass
-10
-9
-0.005
Pass
-5
-0.003
Pass
10
-12
-0.006
Pass
20
-7
-0.004
Pass
30
-11
-0.006
Pass
40
-18
-0.010
Pass
50
-8
-0.004
Pass
-30
-12
-0.006
Pass
-20
-10
-0.005
Pass
-10
-9
-0.005
Pass
-2
-0.001
Pass
10
-3
-0.002
Pass
20
-2
-0.001
Pass
30
-5
-0.003
Pass
40
-11
-0.006
Pass
50
-21
-0.011
Pass
Audix Technology (Shenzhen) Co., Ltd.
9-7
Report No. ACS-F18056
R
AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID: 2AO7Q-X600M1
page
10-1
10. DEVIATION TO TEST SPECIFICATIONS
[ NONE]
Audix Technology (Shenzhen) Co., Ltd.
Report No. ACS-F18056
Download: X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Mirror Download [FCC.gov]X600M1 Gemini 4G Test Report _GSM_Part 2 of 3 Planet Computers Limited
Document ID3999256
Application ID/B8GjrNNH/jPXTtU5DjEZw==
Document DescriptionTest Report_GSM_Part 2 of 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize437.12kB (5463940 bits)
Date Submitted2018-09-11 00:00:00
Date Available2018-09-11 00:00:00
Creation Date2018-08-15 11:22:45
Producing Software福昕PDF打印机 版本 8.1.1.1026
Document Lastmod2018-08-15 11:23:07
Document TitleTest Report_GSM_Part 2 of 3

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Modify Date                     : 2018:08:15 11:23:07+08:00
Create Date                     : 2018:08:15 11:22:45+08:00
Metadata Date                   : 2018:08:15 11:23:07+08:00
Format                          : application/pdf
Document ID                     : uuid:a65938e8-4dc9-4287-ab9b-a57dad5febe5
Instance ID                     : uuid:4c4b6b03-003f-44b0-8cd0-1fceb59af05d
Producer                        : 福昕PDF打印机 版本 8.1.1.1026