PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.

JMTek Industries(Shenzhen) Co., Ltd. Power Bank with Wireless Charging

Page 1 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Page 2 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Page 3 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Page 4 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Page 5 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Page 6 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Page 7 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Page 8 of PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.

Page 1 of 8
Report No.: HK180719412-2E
FCC TEST REPORT
Test report
On Behalf of
JMTek Industries(Shenzhen) Co., Ltd
For
Power Bank with Wireless Charging
Model No.: PBW200
FCC ID: 2APU5-PBW200
Prepared for :
JMTek Industries(Shenzhen) Co., Ltd
14G, Innovation Tech Building, Quanzhi Science and Technology innovation Park,
ShaJing Street, Bao’an District, ShenZhen 518104, China
Prepared By :
Shenzhen HUAK Testing Technology Co., Ltd.
1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street,
Bao'an District, Shenzhen City, China
Date of Test:
Jul. 19, 2018 ~ Jul. 26, 2018
Date of Report:
Jul. 26, 2018
Report Number:
HK180719412-2E
Page 2 of 8
Report No.: HK180719412-2E
Note:
1. For a more detailed features description, please refer to the manufacturer’s specifications
or the User's Manual.
2.
Channel List
Channel
Frequency
(KHz)
01
125
Channel
Frequency
(MHz)
Channel
Frequency
(MHz)
Channel
Frequency
(MHz)
The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible
party shall be used with the device.
2. SUMMARY OF TEST RESULTS
2.1 Test procedures according to the technical standards:
FCC KDB680106 D01 RF Exposure Wireless Charging Apps v03
FCC CFR 47
Standard
Section
Test Item
Judgment
FCC CFR 47 part1,
Electric Field Strength (E) (V/m)
PASS
Magnetic Field Strength (H) (A/m)
PASS
Remark
1.1310 KDB680106
D01v03 (3)(3)
2.2 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95 %。
No.
Item
Uncertainty
All emissions,radiated(<30M)(9KHz-30MHz)
±2.45dB
Temperature
±0.5°C
Humidity
±2%
Page 3 of 8
Report No.: HK180719412-2E
2.3 Test Instruments
Description
Brand
Model No.
Frequency
Range
Broadband Field
Meter
NARDA
NBM-550
Magnetic Field
Meter
NARDA
ELT-400
1 – 400kHz
Magnetic Probe
Calibrated Date Calibrated Until
Dec. 28, 2017
Dec. 27, 2018
Dec. 28, 2017
Dec. 27, 2018
NARDA
HF-3061 300kHz – 30MHz Dec. 28, 2017
Dec. 27, 2018
Magnetic Probe
NARDA
HF-0191
Dec. 28, 2017
Dec. 27, 2018
Broadband Field
Meter
NARDA
NBM-550
Dec. 28, 2017
Dec. 27, 2018
Electric Field
Meter
COMBINOVA
EFM 200
Dec. 28, 2017
Dec. 27, 2018
E-Field Probe
NARDA
EF-0391
100kHz – 3GHz Dec. 28, 2017
Dec. 27, 2018
E-Field Probe
NARDA
EF-6091
27 – 1000MHz
5Hz – 400kHz
100MHz –
60GHz
Dec. 28, 2017
NOTE: 1. The calibration interval of the above test instruments is 12 months .
Dec. 27, 2018
Page 4 of 8
Report No.: HK180719412-2E
3. MAXIMUM PERMISSIBLE EXPOSURE
3.1 MAXIMUM PERMISSIBLE EXPOSURE
Limit of Maximum Permissible Exposure
Limits for Occupational / Controlled Exposure
Frequency Range
Electric Field
Magnetic Field
Strength
(H) (A/m)
(MHz)
Strength (E) (V/m)
Power Density (S)
(mW/ cm²)
Averaging Time
|E|²,|H|² or
S (minutes)
0.3-3.0
614
1.63
(100)*
3.0-30
1842 / f
4.89 / f
(900 / f)*
30-300
61.4
0.163
1.0
300-1500
F/300
1500-100,000
Limits for General Population / Uncontrolled Exposure
Frequency Range
Electric Field
Magnetic Field Power Density (S)
(MHz)
Strength (E) (V/m) Strength (H) (A/m)
(mW/ cm²)
Averaging Time
|E|²,|H|² or S
(minutes)
0.3-1.34
614
1.63
(100)*
30
1.34-30
824/f
2.19/f
(180 / f)*
30
30-300
27.5
0.073
0.2
30
300-1500
F/1500
30
1500-100,000
30
Note 1: f = frequency in MHz ; *Plane-wave equivalent power density
Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03
Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table
1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable
exposure limits below 100 kHz.
Page 5 of 8
Report No.: HK180719412-2E
4. TEST PROCEDURE
a. For devices designed for typical desktop applications, such a wireless charging pads, RF
exposure evaluation should be conducted assuming a user separation distance of 15 cm.
E and H field strength measurements or numerical modeling may be used to demonstrate
compliance. Measurements should be made from all sides and the top of the primary/client
pair, with the 15 cm measured from the center of the probe(s) to the edge of the device.
4.1 TEST SETUP
4.2 RESULT OF MAXIMUM PERMISSIBLE EXPOSURE
Page 6 of 8
Report No.: HK180719412-2E
For Full load mode:
E-Field Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency
Test
Test
Test
Test
Test
Limits
Range
Position Position
Position Position Position
Test
(MHz)
(V/m)
0.125
1.20
1.21
1.19
1.22
1.18
614
H-Field Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency
Test
Test
Test
Test
Test
Limits
Range
Position Position
Position Position Position
Test
(MHz)
(A/m)
0.125
0.21
0.25
0.26
0.23
0.22
1.63
For Half Load for wrist band mode:
E-Field Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency
Test
Test
Test
Test
Test
Limits
Range
Position Position
Position Position Position
Test
(MHz)
(V/m)
0.125
1.20
1.15
1.27
1.21
1.18
614
H-Field Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency
Range
(MHz)
Test
Position
Test
Position
Test
Position
0.125
0.24
0.21
0.20
Test
Test
Position Position
0.18
0.21
Limits
Test
(A/m)
1.63
Page 7 of 8
Report No.: HK180719412-2E
For Half Load for shoepod mode:
E-Field Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency
Range
(MHz)
Test
Position
Test
Position
Test
Position
0.125
1.18
1.19
1.20
Test
Test
Position Position
1.18
1.23
Limits
Test
(V/m)
614
H-Field Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency
Range
(MHz)
Test
Position
Test
Position
Test
Position
0.125
0.23
0.28
0.15
Test
Test
Limits Test
Position Position
(A/m)
0.17
0.21
1.63
For No load mode:
E-Field Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency
Range
(MHz)
Test
Position
Test
Position
Test
Position
0.125
1.21
1.20
1.23
Test
Test
Position Position
1.26
1.21
Limits
Test
(V/m)
614
H-Field Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency
Range
(MHz)
Test
Position
Test
Position
Test
Position
0.125
0.21
0.26
0.29
Test
Test
Position Position
0.21
0.24
Limits
Test
(A/m)
1.63
Page 8 of 8
PHOTOGRAPH OF TEST
※※※※※THE END※※※※※
Report No.: HK180719412-2E
Download: PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Mirror Download [FCC.gov]PBW200 Power Bank with Wireless Charging RF Exposure Info Wireless charging MPE-Test Report JMTek Industries(Shenzhen) Co., Ltd.
Document ID3947893
Application IDQ5Q4TVQakKziqnXyRVZM0Q==
Document DescriptionWireless charging MPE-Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize15.81kB (197569 bits)
Date Submitted2018-08-02 00:00:00
Date Available2018-08-02 00:00:00
Creation Date2018-08-01 16:49:06
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2018-08-01 16:49:06
Document TitleWireless charging MPE-Test Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Administrator
Create Date                     : 2018:08:01 16:49:06+08:00
Modify Date                     : 2018:08:01 16:49:06+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Creator                         : Administrator
Title                           : Microsoft Word - Wireless charging MPE-Test Report
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:22f0163a-1cd3-41ea-8089-d80991b85c05
Instance ID                     : uuid:926e6e0e-f499-4352-b093-0ac7ad10a1e2
Page Count                      : 8