PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.

JMTek Industries(Shenzhen) Co., Ltd. Power Bank with Wireless Charging

Page 1 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 2 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 3 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 4 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 5 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 6 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 7 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 8 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 9 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 10 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 11 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 12 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 13 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 14 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 15 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 16 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 17 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 18 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 19 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Page 20 of PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.

Page 1 of 20
Report No.: HK180719412-E
FCC TEST REPORT
Test report
On Behalf of
JMTek Industries(Shenzhen) Co., Ltd
For
Power Bank with Wireless Charging
Model No.: PBW200
FCC ID: 2APU5-PBW200
Prepared for :
JMTek Industries(Shenzhen) Co., Ltd
14G, Innovation Tech Building, Quanzhi Science and Technology innovation
Park, ShaJing Street, Bao’an District, ShenZhen 518104, China
Prepared By :
Shenzhen HUAK Testing Technology Co., Ltd.
1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street,
Bao'an District, Shenzhen City, China
Date of Test:
Jul. 19, 2018 ~ Jul. 26, 2018
Date of Report:
Jul. 26, 2018
Report Number:
HK180719412-E
Page 2 of 20
Report No.: HK180719412-E
TEST RESULT CERTIFICATION
Applicant’s name ................. : JMTek Industries(Shenzhen) Co., Ltd
14G, Innovation Tech Building, Quanzhi Science and Technology
Address ................................. : innovation Park, ShaJing Street, Bao’an District, ShenZhen
518104, China
Manufacture's Name ............ : JMTek Industries(Shenzhen) Co., Ltd
14G, Innovation Tech Building, Quanzhi Science and Technology
Address ................................. : innovation Park, ShaJing Street, Bao’an District, ShenZhen
518104, China
Product description
N/A
Trade Mark:
Product name ........................... : Power Bank with Wireless Charging
Model and/or type reference : PBW200
Standards ............................. :
FCC Rules and Regulations Part 15 Subpart C (Section 15.209),
ANSI C63.10: 2013
This publication may be reproduced in whole or in part for non-commercial purposes as long as
the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced
material due to its placement and context.
Date of Test ............................................ :
Date (s) of performance of tests ............. :
Jul. 19, 2018 ~ Jul. 26, 2018
Date of Issue ........................................... :
Jul. 26, 2018
Test Result ............................................... :
Pass
Testing Engineer
(Gary Qian)
Technical Manager
(Eden Hu)
Authorized Signatory :
(Jason Zhou)
Page 3 of 20
Table of Contents
1 . TEST SUMMARY
1.1 TEST PROCEDURES AND RESULTS
1.2 TEST FACILITY
1.3 MEASUREMENT UNCERTAINTY
Report No.: HK180719412-E
Page
2. GENERAL INFORMATION
2.1 General Description of EUT
2.2. Carrier Frequency of Channels
2.3 Operation of EUT during testing
2.4 Description of Test Setup
2.5 Measurement Instruments List
3. CONDUCTED EMISSION TEST
3.1 Block Diagram of Test Setup
3.2 Conducted Power Line Emission Limit
3.3 Test Procedure
3.4 Test Result
4. Occupied Bandwidth
4.1 Block Diagram of Test Setup
4.2 Rules and specifications
4.3 Test Procedure
4.4 Test Result
5. RADIA TED EMISSIONS
5.1 Block Diagram of Test Setup
5.2 Rules and specifications
5.3 Test Procedure
5.4 Test Result
11
11
11
11
11
13
13
14
15
15
6 ANTENNA REQUIREMENT
18
7. PHOTOGRAPH OF TEST
19
7.1 Radiated Emission
7.2 Conducted Emission
19
20
Page 4 of 20
Report No.: HK180719412-E
1. TEST SUMMARY
1.1 TEST PROCEDURES AND RESULTS
DESCRIPTION OF TEST
CONDUCTED EMISSIONS TEST
RADIATED EMISSION TEST
OCCUPIED BANDWIDTH MEASUREMENT
ANTENNA REQUIREMENT
RESULT
COMPLIANT
COMPLIANT
COMPLIANT
COMPLIANT
1.2 TEST FACILITY
Test Firm
Address
: Shenzhen HUAK Testing Technology Co., Ltd.
1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai
Street, Bao'an District, Shenzhen City, China
1.3 MEASUREMENT UNCERTAINTY
Measurement Uncertainty
Conducted Emission Expanded Uncertainty
Radiated emission expanded uncertainty(9kHz-30MHz)
Radiated emission expanded uncertainty(30MHz-1000MHz)
Radiated emission expanded uncertainty(Above 1GHz)
2.23dB, k=2
3.08dB, k=2
4.42dB, k=2
4.06dB, k=2
Page 5 of 20
2. GENERAL INFORMATION
2.1 General Description of EUT
Equipment
Power Bank with Wireless Charging
Model Name
PBW200
Serial No.
N/A
Model Difference
N/A
Trade Mark
N/A
FCC ID
2APU5-PBW200
Antenna Type
Coil Antenna
Antenna Gain
1.0dBi
BT Operation frequency
125KHz
Number of Channels
Modulation Type
ASK
Power Source
DC voltage
Power Rating
Input voltage: DC5V 2A From adapter
Output voltage: DC5V
Report No.: HK180719412-E
Page 6 of 20
Report No.: HK180719412-E
2.2. Carrier Frequency of Channels
Operation Frequency each of channel
Channel
Frequency
125KHz
2.3 Operation of EUT during testing
Operating Mode
The mode is used: Transmitting mode
2.4 Description of Test Setup
Operation of EUT during testing
AC 120V/60Hz
Adapter
EUT
Mobile
phones
Setup:Transmission mode
● Adapter information
Model: HW-059200CHQ
Input: 100-240V~, 50/60Hz, 0.5A
Output: 5VDC, 2A
● Mobile phones information
Model: S6
Input: 5VDC
Page 7 of 20
Report No.: HK180719412-E
2.5 Measurement Instruments List
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal.
Interval
1.
L.I.S.N.
Artificial Mains
Network
R&S
ENV216
HKE-002
Dec. 28, 2017
1 Year
2.
Receiver
R&S
ESCI 7
HKE-010
Dec. 28, 2017
1 Year
3.
RF automatic
control unit
Tonscend
JS0806-2
HKE-060
Dec. 28, 2017
1 Year
4.
Spectrum analyzer
R&S
FSP40
HKE-025
Dec. 28, 2017
1 Year
5.
Spectrum analyzer
Agilent
N9020A
HKE-048
Dec. 28, 2017
1 Year
6.
Preamplifier
Schwarzbeck
BBV 9743
HKE-006
Dec. 28, 2017
1 Year
7.
EMI Test Receiver
Rohde & Schwarz
ESCI 7
HKE-010
Dec. 28, 2017
1 Year
8.
Bilog Broadband
Antenna
Schwarzbeck
VULB9163
HKE-012
Dec. 28, 2017
1 Year
9.
Loop Antenna
Schwarzbeck
FMZB 1519
HKE-014
Dec. 28, 2017
1 Year
10.
Horn Antenna
Schewarzbeck
9120D
HKE-013
Dec. 28, 2017
1 Year
11.
Pre-amplifier
EMCI
EMC051845
SE
HKE-015
Dec. 28, 2017
1 Year
12.
Pre-amplifier
Agilent
83051A
HKE-016
Dec. 28, 2017
1 Year
13.
EMI Test Software
EZ-EMC
Tonscend
JS1120-B
Version
HKE-083
Dec. 28, 2017
N/A
14.
Power Sensor
Agilent
E9300A
HKE-086
Dec. 28, 2017
1 Year
15.
Spectrum analyzer
Agilent
N9020A
HKE-048
Dec. 28, 2017
1 Year
16.
Signal generator
Agilent
N5182A
HKE-029
Dec. 28, 2017
1 Year
17.
Signal Generator
Agilent
83630A
HKE-028
Dec. 28, 2017
1 Year
18.
Shielded room
Shiel Hong
4*3*3
HKE-039
Dec. 28, 2017
3 Year
Page 8 of 20
3.
Report No.: HK180719412-E
CONDUCTED EMISSION TEST
3.1 Block Diagram of Test Setup
3.2 Conducted Power Line Emission Limit
According to FCC Part 15.207(a)
* Decreasing linearly with the logarithm of the frequency
For intentional device, according to §15.207Line Conducted Emission Limit is same as
above table.
3.3 Test Procedure
1, The equipment was set up as per the test configuration to simulate typical actual usage per the
user’s manual. The EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and
is placed on the ground plane as per ANSI C63.10.
2, Support equipment, if needed, was placed as per ANSI C63.10.
3, All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
4, If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power
source and was grounded to the ground plane.
5, All support equipments received AC power from a second LISN, if any.
6, The EUT test program was started. Emissions were measured on each current carrying line of the
EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has
two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with
Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan
had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
7, Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes
3.4 Test Result
PASS
Page 9 of 20
Report No.: HK180719412-E
Test Specification: Line
Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level
Page 10 of 20
Report No.: HK180719412-E
Test Specification: Neutral
Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level
Page 11 of 20
4.
Report No.: HK180719412-E
Occupied Bandwidth
4.1 Block Diagram of Test Setup
4.2 Rules and specifications
CFR 47 Part 15.215(c)
ANSI C63.10-2013
4.3 Test Procedure
Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in §§15.217 through 15.257 and in subpart E of this part, must be designed to ensure that 20dB bandwidth
of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which
the equip compliance with the 20dB attenuation specification may base on measurement at the intentional
radiator’s antenna output terminal unless the intentional radiator uses a permanently attached antenna, in
which case compliance shall be.deomonstrated by measuring the radiated emissions.
4.4 Test Result
PASS
Mode
Freq
(KHz)
20dB Bandwidth
(KHz)
Limit (kHz)
Conclusion
Tx Mode
125
2.850
PASS
Page 12 of 20
Report No.: HK180719412-E
Page 13 of 20
5.
RADIA TED EMISSIONS
5.1 Block Diagram of Test Setup
Report No.: HK180719412-E
Page 14 of 20
Report No.: HK180719412-E
5.2 Rules and specifications
CFR 47 Part 15, section 15.205
Only spurious emissions are permitted in any of the frequency bands listed the tables in these sections.
CFR 47 Part 15, section 15.209
The emissions from an intentional radiator shall not exceed the limits in the tables in these sections using an
average detector
CFR 47 Part 15, section 15.35
When average radiated emission measurements are specified, the limit on the peak level of the radio
Frequency emission is 20dB above the maximum permitted average emission limit.
Transmitter Spurious Emissions 9KHz-30MHz
9-150KHz
150-490KHz
490KHz-30MHz
Resolution Bandwidth
200Hz
9KHz
9KHz
Video Bandwidth
2KHz
100KHz
100KHz
Detector
Peak
Peak
Peak
Trace Mode
Max Hold
Max Hold
Max Hold
Sweep Time
Auto
Auto
Auto
Page 15 of 20
Report No.: HK180719412-E
5.3 Test Procedure
Measurement distance 3m
For the measurement range up to 30MHz in the following plots the field strength result from 3m
Distance measurement are extrapolated to 300m and 30m distance respectively, by 40dB/decade,
According to part 15.31(f)(2), per antenna factor scaling.
Measurements below 1000MHz are performed with a peak detector and compared to average limits,
Measurements with an average detector are not required.
Note:
For battery operated equipment, the equipment tests shall be performed using a new battery.
5.4
Test Result
PASS
For 9KHz-30MHz
Freq.
(MHz)
Detector
Mode
(PK/QP)
Reading
(dBuV)
0.110
Peak
23.69
24.8
48.49
126.77
78.28
0.125
Peak
46.06
24.8
70.86
125.67
54.81
0.486
Peak
26.44
25.03
51.47
113.71
62.24
0.500
Peak
26.58
25.03
51.61
113.62
62.01
Factor
(dB)
Actual FS Limits 3m
(dBuV/m) (dBuV/m)
Margin
(dBuV/m)
Page 16 of 20
Report No.: HK180719412-E
For 30MHz-1GHz
Antenna polarity: H
Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level
Page 17 of 20
Report No.: HK180719412-E
Antenna polarity: V
Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level
Page 18 of 20
Report No.: HK180719412-E
6 ANTENNA REQUIREMENT
Standard Applicable
For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
designed to ensure that no antenna other than that furnished by the responsible party shall be used
with the device.
Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.
Antenna Connected Construction
The antenna used in this product is a Coil Antenna, The directional gains of antenna used for
transmitting is 1dBi.
ANTENNA
Page 19 of 20
7. PHOTOGRAPH OF TEST
7.1 Radiated Emission
Report No.: HK180719412-E
Page 20 of 20
7.2 Conducted Emission
Report No.: HK180719412-E
Download: PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Mirror Download [FCC.gov]PBW200 Power Bank with Wireless Charging Test Report Wireless_charging_Test_report_FCC_ID JMTek Industries(Shenzhen) Co., Ltd.
Document ID3947894
Application IDQ5Q4TVQakKziqnXyRVZM0Q==
Document DescriptionWireless_charging_Test_report_FCC_ID
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize74.82kB (935190 bits)
Date Submitted2018-08-02 00:00:00
Date Available2018-08-02 00:00:00
Creation Date2018-07-31 16:33:57
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2018-07-31 16:33:57
Document TitleWireless_charging_Test_report_FCC_ID
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Administrator
Create Date                     : 2018:07:31 16:33:57+08:00
Modify Date                     : 2018:07:31 16:33:57+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Creator                         : Administrator
Title                           : Microsoft Word - Wireless charging Test report  FCC ID
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:1e1afa04-7a14-479e-b8bd-5a8c9e4c28fd
Instance ID                     : uuid:9caee276-3c2e-481a-9619-e0f6fef1e692
Page Count                      : 20