RF Exposure Report
Report No.: SA170307C24
FCC ID: A8J-EAP1300
Test Model: EAP1300, EAP1300EXT
Received Date: Feb. 17, 2017
Test Date: Feb. 17 ~ Apr. 18, 2017
Issued Date: Apr. 20, 2017
Applicant: EnGenius Technologies
Address: 1580 Scenic Avenue, Costa Mesa, CA92626
Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
(R.O.C.)
Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
33383, TAIWAN (R.O.C.)
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: SA170307C24
Page No. 1 / 5
Report Format Version: 6.1.1
Table of Contents
Release Control Record .................................................................................................................................. 3
Certificate of Conformity...................................................................................................................... 4
RF Exposure .......................................................................................................................................... 5
2.1
2.2
2.3
Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
MPE Calculation Formula ................................................................................................................... 5
Classification ....................................................................................................................................... 5
Calculation Result of Maximum Conducted Power........................................................................... 5
Report No.: SA170307C24
Page No. 2 / 5
Report Format Version: 6.1.1
Release Control Record
Issue No.
Description
Date Issued
SA170307C24
Original release.
Apr. 20, 2017
Report No.: SA170307C24
Page No. 3 / 5
Report Format Version: 6.1.1
1
Certificate of Conformity
Product: Dual Band Indoor Access Point
Brand: EnGenius
Test Model: EAP1300, EAP1300EXT
Sample Status: Engineering sample
Applicant: EnGenius Technologies
Test Date: Feb. 17 ~ Apr. 18, 2017
Standards: FCC Part 2 (Section 2.1091)
KDB 447498 D01 General RF Exposure Guidance v06
IEEE C95.1
The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.
Prepared by :
, Date:
Apr. 20, 2017
, Date:
Apr. 20, 2017
Suntee Liu / Specialist
Approved by :
Ken Liu / Senior Manager
Report No.: SA170307C24
Page No. 4 / 5
Report Format Version: 6.1.1
2
RF Exposure
2.1 Limits for Maximum Permissible Exposure (MPE)
Frequency Range
(MHz)
Electric Field
Strength (V/m)
Magnetic Field
Strength (A/m)
Power Density
(mW/cm2)
Average Time
(minutes)
Limits For General Population / Uncontrolled Exposure
300-1500
…
…
F/1500
30
1500-100,000
…
…
1.0
30
F = Frequency in MHz
2.2 MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm
2.3 Classification
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.
Calculation Result of Maximum Conducted Power
Frequency Band
(MHz)
Max Power
(dBm)
WLAN 2412~2462
WLAN 5180~5240
WLAN 5745~5825
24.60
24.36
25.05
Antenna Gain
Distance (cm)
(dBi)
CDD Mode
8.68
20
8.01
20
8.01
20
Beamforming Mode
8.68
20
8.01
20
8.01
20
WLAN 2412~2462
21.03
WLAN 5180~5240
20.73
WLAN 5745~5825
22.04
Note:
2.4GHz: Max. directional gain = 5.67dBi + 10log(2) = 8.68dBi
5GHz: Max. directional gain = 5dBi + 10log(2) = 8.01dBi
Power Density
(mW/cm2)
Limit (mW/cm2)
0.423
0.343
0.402
0.186
0.149
0.201
Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density
WLAN 2.4GHz + WLAN 5GHz = 0.423 + 0.402 = 0.825 < 1
---END---
Report No.: SA170307C24
Page No. 5 / 5
Report Format Version: 6.1.1
Download: EAP1300 Dual Band Indoor Access Point RF Exposure Info (MPE)_rev EnGenius Technologies
Mirror Download [FCC.gov]EAP1300 Dual Band Indoor Access Point RF Exposure Info (MPE)_rev EnGenius Technologies
Document ID3411130
Application IDcTFJxx7lbWyNfRmNVoyWbA==
Document DescriptionRF Exposure Info (MPE)_rev.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize4.62kB (57749 bits)
Date Submitted2017-06-01 00:00:00
Date Available2017-06-12 00:00:00
Creation Date2017-10-23 15:01:47
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-23 15:01:47
Document TitleRF Exposure Info (MPE)_rev
Document CreatorPScript5.dll Version 5.2.2
Document Author: pettchen

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:29710a3e-988d-11f2-0000-02c7314339d4
Producer                        : GPL Ghostscript 9.18
Modify Date                     : 2017:07:04 04:24:04Z
Create Date                     : 2017:07:04 04:24:04Z
Creator Tool                    : UnknownApplication
Document ID                     : uuid:29710a3e-988d-11f2-0000-02c7314339d4
Format                          : application/pdf
Title                           : Untitled