JBLGO2H Portable Bluetooth Speaker Test Report Harman International Industries, Inc

Harman International Industries, Inc Portable Bluetooth Speaker

Page 1 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 2 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 3 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 4 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 5 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 6 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 7 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 8 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 9 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 10 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 11 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 12 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 13 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 14 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 15 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 16 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 17 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 18 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Page 19 of JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc

Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
Report No.: DDT-R18041303-1E2
Issued Date: Apr. 19, 2018
FCC CERTIFICATION TEST REPORT
FOR
Applicant
: Harman International Industries, Incorporated
8500 Balboa Boulevard, Northridge, CA 91329,
: UNITED STATES
Equipment under Test : PORTABLE BLUETOOTH SPEAKER
Address
Model No.
: GO2H
Trade Mark
: JBL
FCC ID
: APIJBLGO2H
Manufacturer
: Harman International Industries, Incorporated
Address
: UNITED STATES
8500 Balboa Boulevard, Northridge, CA 91329,
Issued By: Dongguan Dongdian Testing Service Co., Ltd.
Add: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan
City, Guangdong Province, China, 523808
Tel: +86-0769-89201699
E-mail: ddt@dgddt.com
http://www.dgddt.com
Page 1 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
TABLE OF CONTENTS
Test report declares.....................................................................................................4
1.
Summary of test results ................................................................................................ 4
2.
General test information ............................................................................................... 5
2.1.
Description of EUT........................................................................................................ 5
2.2.
Accessories of EUT ...................................................................................................... 5
2.3.
Assistant equipment used for test ................................................................................. 5
2.4.
Block diagram of EUT configuration for test ................................................................. 5
2.5.
Deviations of test standard ........................................................................................... 6
2.6.
Test environment conditions ......................................................................................... 6
2.7.
Test laboratory .............................................................................................................. 6
2.8.
Measurement uncertainty ............................................................................................. 6
3.
Equipment used during test .......................................................................................... 7
4.
Radiated emission ........................................................................................................ 9
4.1.
Block diagram of test setup .......................................................................................... 9
4.2.
Limit ............................................................................................................................ 10
4.3.
Test Procedure ........................................................................................................... 11
4.4.
Test result ................................................................................................................... 12
5.
Power Line Conducted Emission ................................................................................ 16
5.1.
Block diagram of test setup ........................................................................................ 16
5.2.
Power Line Conducted Emission Limits ...................................................................... 16
5.3.
Test Procedure ........................................................................................................... 16
5.4.
Test Result ................................................................................................................. 17
6.
Test setup photograph ................................................................................................ 20
7.
Photos of the EUT ...................................................................................................... 21
Page 2 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
TEST REPORT DECLARE
Applicant
Address
Equipment
Test
under
Model No.
Trade mark
Manufacturer
Address
Harman International Industries, Incorporated
PORTABLE BLUETOOTH SPEAKER
GO2H
8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES
JBL
Harman International Industries, Incorporated
8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES
Test Standard Used:
FCC Rules and Regulations Part 15 Subpart C.
Test procedure used:
ANSI C63.10:2013.
We Declare:
The equipment described above is tested by Dongguan Dongdian Testing Service Co., Ltd. and
in the configuration tested the equipment complied with the standards specified above. The test
results are contained in this test report and Dongguan Dongdian Testing Service Co., Ltd. is
assumed of full responsibility for the accuracy and completeness of these tests.
After test and evaluation, our opinion is that the equipment provided for test compliance
with the requirement of the above FCC standards.
Report No.:
DDT-R18041303-1E2
Date of Receipt:
Oct. 18, 2017
Prepared By:
__________________
Ella Gong/Engineer
Date of Test:
Oct. 18, 2017 ~ Apr. 19, 2018
Approved By:
______________________
Kevin Feng/EMC Manager
Note: This report applies to above tested sample only. This report shall not be reproduced in
parts without written approval of Dongguan Dongdian Testing Service Co., Ltd.
Page 3 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
1. Summary of test results
Description of Test Item
Standard
Results
Radiated Emission
FCC Part 15: 15.209
FCC Part 15: 15.247(d)
ANSI C63.10 :2013
ANSI C63.4:2014
PASS
Power Line Conducted Emissions
FCC Part 15: 15.207
ANSI C63.10 :2013
ANSI C63.4:2014
PASS
Note 1: N/A is an abbreviation for Not Applicable.
Note 2: There is power amplifier add in this report base on the original report:
DDT-R17101804-1E2, This change don’t influence the RF performance, so power line
conducted and radiated emission(below 1GHz) were tested and updated in this report only.
Page 4 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
2. General test information
2.1. Description of EUT
EUT* Name
Model Number
EUT function description
: PORTABLE BLUETOOTH SPEAKER
: GO2H
: Please reference user manual of this device
DC 5V from external AC Adapter
Power supply
DC 3.7V built-in battery
Radio Specification
: Bluetooth V4.1 (only BDR/EDR)
: 2402MHz -2480MHz
Operation frequency
: GFSK, /4 QPSK, 8-DPSK
Modulation
: 1Mbps, 2Mbps, 3Mbps
Data rate
: Integrated antenna, maximum PK gain: 1.3dBi
Antenna Type
Sample Type
: Series production
Note 1: EUT is the ab. of equipment under test.
2.2. Accessories of EUT
Description of
Accessories
Manufacturer
Model number
Serial No.
Other
N/A
N/A
N/A
N/A
N/A
Serial No.
Other
2.3. Assistant equipment used for test
Assistant
equipment
AC Adapter
Notebook
Manufacturer
Group Intellect
Power
Technology
Limited
DELL
Model
number
F5V-2.3C-1U
N/A
Latitude D610
FCC DOC
Input: AC 100-240V
-50/60Hz, 0.5A;
Output: DC 5V,
2.3A
00045-534-136-300
2.4. Block diagram of EUT configuration for test
AC Mains
AC Adapter
EUT
Test software: ASTTestTool.exe
The test software was used to control EUT work in Continuous TX mode, and select test channel,
wireless mode as blow table.
Page 5 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
Tested mode, channel, information
Frequency
(MHz)
GFSK hopping on Tx Mode
CH0 to CH78
2402 to 2480
π/4 QPSK Hopping on TX mode
CH0 to CH78
2402 to 2480
8-DPSK hopping on Tx Mode
CH0 to CH78
2402 to 2480
CH0
2402
GFSK hopping off Tx Mode
CH39
2441
CH78
2480
CH0
2402
/4 QPSK hopping off Tx Mode
CH39
2441
CH78
2480
CH0
2402
8-DPSK hopping off Tx Mode
CH39
2441
CH78
2480
Note: For /4 QPSK its same modulation type with 8-DPSK, and based exploratory test, there is
no significant difference of that two types test result, so except output power, all other items final
test were only performed with the worse case 8-DPSK and GFSK.
Mode
Channel
2.5. Deviations of test standard
No Deviation.
2.6. Test environment conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature range:
Humidity range:
Pressure range:
21-25℃
40-75%
86-106kPa
2.7. Test laboratory
Dongguan Dongdian Testing Service Co., Ltd
Add: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City,
Guangdong Province, China, 523808 Tel: +86-0769-89201699 http://www.dgddt.com
CNAS Accreditation No. L6451; A2LA Accreditation No. 3870.01
Designation Number: CN1182; Test Firm Registration Number: 540522
Industry Canada site registration number: 10288A-1
2.8. Measurement uncertainty
Test Item
Bandwidth
Uncertainty
1.1%
Peak Output Power(Conducted)( Spectrum
analyzer)
0.86dB(10 MHz ≤ f < 3.6GHz);
Peak Output Power(Conducted)(Power Sensor)
0.74dB
Dwell Time
0.6%
1.38dB(3.6GHz≤ f < 8GHz)
Page 6 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
0.86dB(10 MHz ≤ f < 3.6GHz);
Conducted spurious emissions
1.40dB(3.6GHz≤ f < 8GHz)
1.66dB(8GHz≤ f < 22GHz)
3×10-8
0.4℃
2%
4.70 dB (Antenna Polarize: V)
4.84 dB (Antenna Polarize: H)
4.10dB(1-6GHz)
Uncertainty for Radiation Emission test
(1GHz-18GHz)
4.40dB (6GHz-18Gz)
Uncertainty for Power line conduction emission test
3.32dB (150KHz-30MHz)
Note: This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.
Uncertainty for radio frequency (RBW<20KHz)
Temperature
Humidity
Uncertainty for Radiation Emission test
(30MHz-1GHz)
3. Equipment used during test
Manufacture
Model No.
Serial No.
RF Connected Test (Tonscent RF Measurement System)
Spectrum analyzer
R&S
FSU26
1166.1660.26
Wideband Radio
R&S
CMW500
155523
Communication tester
Vector Signal
Agilent
E8267D
MY52098743
Generator
Vector Signal
Agilent
N5182A
MY48180737
Generator
Power Sensor
Agilent
U2021XA
MY55150010
Power Sensor
Agilent
U2021XA
MY55150011
DC Power Source
MATRIS
MPS-3005L-3 D813058W
Attenuator
Mini-Circuits BW-S10W2
101109
RF Cable
Micable
C10-01-01-1 100309
Temp&Humi
ZXGDJS-150
ZHIXIANG
ZX170110-A
Programmable
Test Software
JS Tonscend JS1120-2
Ver.2.5
USB Data acquisition Agilent
U2531A
TW55043503
Auto control Unit
JS Tonscend JS0806-2
158060010
Radiated Emission Test chamber 1#
EMI Test Receiver
R&S
ESU8
100316
Spectrum analyzer
R&S
FSU26
1166.1660.26
Trilog Broadband
Schwarzbeck VULB9163
9163-462
Antenna
Active Loop antenna Schwarzbeck FMZB-1519 1519-038
Broadband Horn
BBHA 9170
Schwarzbeck BBHA 9170
antenna
#790
Double Ridged Horn
R&S
HF907
100276
Antenna
Pre-amplifier
A.H.
PAM-0118
360
Equipment
Last Cal.
Cal. Interval
Oct. 23, 2017 1 Year
Oct. 21, 2017 1 Year
Oct. 23, 2017 1 Year
Oct. 21, 2017 1 Year
Oct. 21, 2017
Oct. 21, 2017
Oct. 21, 2017
Oct. 21, 2017
Oct. 21, 2017
1 Year
1 Year
1 Year
1 Year
1 Year
Oct. 21, 2017 1Year
N/A
N/A
N/A
N/A
N/A
N/A
Oct. 21, 2017 1 Year
Oct. 21, 2017 1 Year
Oct. 27, 2017 1 Year
Oct. 21, 2017 1 Year
Aug. 11, 2017 1 Year
Oct. 21, 2017 1 Year
Oct. 21, 2017 1 Year
Page 7 of 29
Dongguan Dongdian Testing Service Co., Ltd.
RF Cable
HUBSER
CP-X2
RF Cable
HUBSER
CP-X1
MI Cable
HUBSER
C10-01-01-1M
Test software
Audix
E3
Power Line Conducted Emissions Test
Test Receiver
R&S
ESU8
LISN 1
R&S
ENV216
LISN 2
R&S
ESH2-Z5
Pulse Limiter
R&S
ESH3-Z2
CE Cable 1
HUBSER
ESU8/RF2
Test software
Audix
E3
Report No.: DDT-R18041303-1E2
W11.03
W12.02
1091629
V 6.11111b
Oct. 21, 2017
Oct. 21, 2017
Oct. 21, 2017
N/A
1 Year
1 Year
1 Year
N/A
100316
101109
100309
101242
W10.01
V 6.11111b
Oct. 21, 2017
Oct. 21, 2017
Oct. 21, 2017
Oct. 21, 2017
Oct. 21, 2017
N/A
1 Year
1 Year
1 Year
1 Year
1 Year
N/A
Page 8 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
4. Radiated emission
4.1. Block diagram of test setup
In 3m Anechoic Chamber Test Setup Diagram for 9KHz-30MHz
In 3m Anechoic Chamber Test Setup Diagram for below 1GHz
In 3m Anechoic Chamber Test Setup Diagram for frequency above 1GHz
Page 9 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
Note: For harmonic emissions test a appropriate high pass filter was inserted in the input port of
AMP.
4.2. Limit
(1) FCC 15.205 Restricted frequency band
(2) FCC 15.209 Limit.
FREQUENCY
MHz
0.009 ~ 0.490
0.490 ~ 1.705
1.705 ~ 30.0
30 ~ 88
88 ~ 216
216 ~ 960
960 ~ 1000
DISTANCE
Meters
300
30
30
FIELD STRENGTHS LIMIT
V/m
dB(V)/m
2400/F(KHz)
67.6-20log(F)
24000/F(KHz)
87.6-20log(F)
30
29.54
100
40.0
150
43.5
200
46.0
500
54.0
Page 10 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Above
1000
Report No.: DDT-R18041303-1E2
74.0 dB(V)/m (Peak)
54.0 dB(V)/m (Average)
Note: (1)The emission limits shown in the above table are based on measurements employing a
CISPR QP detector except for the frequency bands 9-90KHz, 110-490KHz and above
1000MHz.Radiated emissions limits in these three bands are based on measurements employing
an average detector.
(2) At frequencies below 30MHz, measurement may be performed at a distance closer then
that specified, and the limit at closer measurement distance can be extrapolated by below
formula:
Limit3m(dBuV/m)= Limit30m(dBuV/m) + 40Log(30m/3m)
(3) Limit for this EUT
All the emissions appearing within 15.205 restricted frequency bands shall not exceed the limits
shown in 15.209, all the other emissions shall be at least 20dB below the fundamental emissions,
or comply with 15.209 limits.
4.3. Test Procedure
(1) EUT was placed on a non-metallic table, 150 cm above the ground plane inside a
semi-anechoic chamber.
(2) Test antenna was located 3m from the EUT on an adjustable mast, and the antenna used as
below table.
Test frequency range
9KHz-30MHz
30MHz-1GHz
1GHz-18GHz
18GHz-40GHz
Test antenna used
Active Loop antenna
Trilog Broadband Antenna
Double Ridged Horn
Antenna(1GHz-18GHz)
Horn
Antenna(18GHz-40GHz)
Test antenna distance
3m
3m
3m
1m
According ANSI C63.10:2013 clause 6.4.4.2 and 6,5.3, for measurements below 30 MHz, the
loop antenna was positioned with its plane vertical from the EUT and rotated about its vertical
axis for maximum response at each azimuth position around the EUT. And the loop antenna also
be positioned with its plane horizontal at the specified distance from the EUT. The center of the
loop is 1 m above the ground. for measurement above 30MHz, the Trilog Broadband Antenna or
Horn Antenna was located 3m from EUT, Measurements were made with the antenna positioned
in both the horizontal and vertical planes of
Polarization, and the measurement antenna was varied from 1 m to 4 m. in height above the
reference ground plane to obtain the maximum signal strength.
(3) Below pre-scan procedure was first performed in order to find prominent frequency spectrum
radiated emissions from 9KHz to 25GHz:
(a) Scanning the peak frequency spectrum with the antenna specified in step (3), and the EUT
Page 11 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
was rotated 360 degree, the antenna height was varied from 1m to 4m(Except loop antenna, it’s
fixed 1m above ground.)
(b) Change work frequency or channel of device if practicable.
(c) Change modulation type of device if practicable.
(d) Change power supply range from 85% to 115% of the rated supply voltage
(e) Rotated EUT though three orthogonal axes to determine the attitude of EUT arrangement
produces highest emissions.
Spectrum frequency from 9KHz to 25GHz (tenth harmonic of fundamental frequency) was
investigated, and no any obvious emission were detected from 18GHz to 25GHz, so below
final test was performed with frequency range from 9KHz to 18GHz.
(4) For final emissions measurements at each frequency of interest, the EUT was rotated and the
antenna height was varied between 1m and 4m in order to maximize the emission.
Measurements in both horizontal and vertical polarities were made and the data was recorded.
In order to find the maximum emission, the relative positions of equipments and all of the
interface cables were changed according to ANSI C63.10 2013 on Radiated Emission test.
(5) The emissions from 9KHz to 1GHz were measured based on CISPR QP detector except for
the
frequency
bands
9-90KHz,
110-490KHz,
for
emissions
from
9KHz-90KHz,110KHz-490KHz and above 1GHz were measured based on average detector,
for emissions above 1GHz, peak emissions also be measured and need comply with Peak
limit.
(6) The emissions from 9KHz to 1GHz, QP or average values were measured with EMI receiver
with below RBW.
Frequency band
RBW
9KHz-150KHz
200Hz
150KHz-30MHz
9KHz
30MHz-1GHz
120KHz
(7) For emissions above 1GHz, both Peak and Average level were measured with Spectrum
Analyzer, and the RBW is set at 1MHz, VBW is set at 3MHz for Peak measure; RMS detector
RBW 1MHz VBW 3MHz for Average measure(according ANSI C63.10:2013 clause 4.2.3.2.3
procedure for average measure).
(8) X axis, Y axis, Z axis are tested, and worse setup X axis is reported.
4.4. Test result
PASS. (See below detailed test result)
All the emissions except fundamental emission from 9 KHz to 25GHz were comply with 15.209
limits.
Note1: According exploratory test no any obvious emission were detected from 9KHz to 30MHz
and 18GHz to 25GHz.
Note2: For emissions below 1GHz, according exploratory explorer test, when change Tx mode
and channel, have no distinct influence on emissions level, so for emissions below 1GHz, the
Page 12 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
final test was only performed with EUT working in GFSK, Tx 2441MHz mode.
Note3: For emissions above 1GHz. If peak results comply with AV limit, AV Result is deemed to
comply with AV limit.
Page 13 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
Radiated Emission test (below 1GHz)
TR-4-E-009 Radiated Emission Test Result
Test Site
: DDT 3m Chamber 1#
D:\2018 RE1# Report Data\Q18041303-1E\FCC BELOW1G.EM6
Test Date
: 2018-04-17
Tested By
: TALENT
EUT
: PORTABLE BLUETOOTH SPEAKER
Model Number
: GO2H
Power Supply
: Battery
Test Mode
: Tx mode
Condition
Antenna/Distance
: 2017 VULB 9163 1#/3m/HORIZONTAL
Memo
: BT
Temp:24.5'C,Humi:55%,
Press:100.1kPa
Data: 1
Detector
Polarization
Item
Freq.
Read
Level
Antenna
Factor
Cable
Loss
Result
Level
Limit
Line
Over
Limit
(Mark)
(MHz)
(dBµV)
(dB/m)
dB
(dBµV/m)
(dBµV/m)
(dB)
47.49
-1.61
13.52
3.96
15.87
40.00
-24.13
QP
HORIZONTAL
107.89
-0.59
10.54
4.48
14.43
43.50
-29.07
QP
HORIZONTAL
213.76
-1.69
11.80
5.10
15.21
43.50
-28.29
QP
HORIZONTAL
284.98
-0.44
13.07
5.46
18.09
46.00
-27.91
QP
HORIZONTAL
370.70
-1.00
14.70
5.84
19.54
46.00
-26.46
QP
HORIZONTAL
640.61
1.19
19.53
6.81
27.53
46.00
-18.47
QP
HORIZONTAL
Note: 1. Result Level = Read Level + Antenna Factor + Cable loss.
2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.
3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.
Page 14 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
TR-4-E-009 Radiated Emission Test Result
Test Site
: DDT 3m Chamber 1#
D:\2018 RE1# Report Data\Q18041303-1E\FCC BELOW1G.EM6
Test Date
: 2018-04-17
Tested By
: TALENT
EUT
: PORTABLE BLUETOOTH SPEAKER
Model Number
: GO2H
Power Supply
: Battery
Test Mode
: Tx mode
Condition
Antenna/Distance
: 2017 VULB 9163 1#/3m/VERTICAL
Memo
: BT
Temp:24.5'C,Humi:55%,
Press:100.1kPa
Data: 2
Item
Freq.
Read
Level
Antenna
Factor
(Mark)
(MHz)
(dBµV)
43.51
3.90
103.81
240.83
Detector
Polarization
-19.13
QP
VERTICAL
43.50
-27.69
QP
VERTICAL
46.00
-26.99
QP
VERTICAL
22.07
46.00
-23.93
QP
VERTICAL
6.12
27.83
46.00
-18.17
QP
VERTICAL
7.42
32.30
46.00
-13.70
QP
VERTICAL
Cable
Loss
Result
Level
Limit
Line
Over
Limit
(dB/m)
dB
(dBµV/m)
(dBµV/m)
(dB)
13.05
3.92
20.87
40.00
0.34
11.03
4.44
15.81
1.44
12.32
5.25
19.01
389.36
1.14
15.02
5.91
556.77
3.09
18.62
836.24
3.09
21.79
Note: 1. Result Level = Read Level + Antenna Factor + Cable loss.
2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.
3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.
Page 15 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
5. Power Line Conducted Emission
5.1. Block diagram of test setup
5.2. Power Line Conducted Emission Limits
Frequency
150kHz
500kHz
5MHz
500kHz
5MHz
30MHz
Quasi-Peak Level
dB(V)
Average Level
dB(V)
66 ~ 56*
56
60
56 ~ 46*
46
50
Note 1: * Decreasing linearly with logarithm of frequency.
Note 2: The lower limit shall apply at the transition frequencies.
5.3. Test Procedure
The EUT and Support equipment, if needed, were put placed on a non-metallic table, 80cm
above the ground plane.
Configuration EUT to simulate typical usage as described in clause 2.4 and test equipment as
described in clause 10.2 of this report.
All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
All support equipment power received from a second LISN.
Emissions were measured on each current carrying line of the EUT using an EMI Test Receiver
connected to the LISN powering the EUT.
The Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
During the above scans, the emissions were maximized by cable manipulation.
The test mode(s) described in clause 2.4 were scanned during the preliminary test.
After the preliminary scan, we found the test mode producing the highest emission level.
Page 16 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
The EUT configuration and worse cable configuration of the above highest emission levels were
recorded for reference of the final test.
EUT and support equipment were set up on the test bench as per the configuration with highest
emission level in the preliminary test.
A scan was taken on both power lines, Neutral and Line, recording at least the six highest
emissions.
Emission frequency and amplitude were recorded into a computer in which correction factors
were used to calculate the emission level and compare reading to the applicable limit.
The test data of the worst-case condition(s) was recorded.
The bandwidth of test receiver is set at 9 KHz.
5.4. Test Result
PASS. (See below detailed test result)
Note1: All emissions not reported below are too low against the prescribed limits.
Note2: “-----” means Peak detection; “-----” means Average detection
Note3:Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz,
recorded worst case.
Page 17 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
TR-4-E-010 Conducted Emission Test Result
Test Site
: DDT 1# Shield Room
D:\2018 CE report data\Q18041203-1E\CE.EM6
Test Date
: 2018-04-14
Tested By
: Jerry
EUT
: PORTABLE BLUETOOTH SPEAKER
Model Number
: GO2H
Power Supply
: AC 120V/60Hz
Test Mode
: Tx mode
Condition
Temp:24.5'C,Humi:55%,
Press:100.1kPa
LISN
: 2017 ENV216/NEUTRAL
Memo
Detector
Phase
-21.87
QP
NEUTRAL
56.00
-25.57
Average
NEUTRAL
59.09
-22.95
QP
NEUTRAL
32.66
49.09
-16.43
Average
NEUTRAL
9.86
44.40
56.00
-11.60
QP
NEUTRAL
9.86
30.95
46.00
-15.05
Average
NEUTRAL
0.13
9.86
37.35
56.00
-18.65
QP
NEUTRAL
9.28
0.13
9.86
30.02
46.00
-15.98
Average
NEUTRAL
9.30
0.12
9.87
35.80
56.00
-20.20
QP
NEUTRAL
Item
Freq.
Read
Level
LISN
Factor
(Mark)
(MHz)
(dBµV)
(dB)
0.15
24.74
9.49
0.15
11.04
9.49
0.34
16.88
9.38
0.34
13.40
0.70
0.70
Cable
Loss
Pulse
Limiter
Factor
Result
Level
Limit
Line
(dB)
(dB)
(dBµV)
(dBµV)
(dB)
0.04
9.86
44.13
66.00
0.04
9.86
30.43
0.04
9.84
36.14
9.38
0.04
9.84
25.13
9.32
0.09
11.68
9.32
0.09
1.73
18.08
9.28
1.73
10.75
2.07
16.51
Over
Limit
10
2.07
6.74
9.30
0.12
9.87
26.03
46.00
-19.97
Average
NEUTRAL
11
7.94
14.71
9.36
0.11
9.88
34.06
60.00
-25.94
QP
NEUTRAL
12
7.94
3.17
9.36
0.11
9.88
22.52
50.00
-27.48
Average
NEUTRAL
Note: 1. Result Level = Read Level +LISN Factor + Pulse Limiter Factor + Cable loss.
2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit.
3. Test setup: RBW: 200 Hz (9 kHz—150 kHz), 9 kHz (150 kHz—30 MHz).
4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.
Page 18 of 29
Dongguan Dongdian Testing Service Co., Ltd.
Report No.: DDT-R18041303-1E2
TR-4-E-010 Conducted Emission Test Result
Test Site
: DDT 1# Shield Room
D:\2018 CE report data\Q18041203-1E\CE.EM6
Test Date
: 2018-04-14
Tested By
: Jerry
EUT
: PORTABLE BLUETOOTH SPEAKER
Model Number
: GO2H
Power Supply
: AC 120V/60Hz
Test Mode
: Tx mode
Condition
Temp:24.5'C,Humi:55%,
Press:100.1kPa
LISN
: 2017 ENV216/LINE
Memo
Item
Freq.
Read
Level
LISN
Factor
(Mark)
(MHz)
(dBµV)
(dB)
0.15
24.56
9.52
0.15
11.51
9.52
0.70
23.69
9.55
0.70
10.89
1.72
1.72
Cable
Loss
Detector
Phase
-21.98
QP
LINE
55.96
-25.03
Average
LINE
56.00
-12.81
QP
LINE
46.00
-15.61
Average
LINE
-28.27
QP
LINE
-23.18
Average
LINE
-17.01
QP
LINE
46.00
-14.41
Average
LINE
56.00
-20.77
QP
LINE
27.20
46.00
-18.80
Average
LINE
34.71
60.00
-25.29
QP
LINE
21.88
50.00
-28.12
Average
LINE
Pulse
Limiter
Factor
Result
Level
Limit
Line
(dB)
(dB)
(dBµV)
(dBµV)
(dB)
0.04
9.86
43.98
65.96
0.04
9.86
30.93
0.09
9.86
43.19
9.55
0.09
9.86
30.39
8.15
9.59
0.13
9.86
27.73
56.00
3.24
9.59
0.13
9.86
22.82
46.00
2.08
19.40
9.60
0.12
9.87
38.99
56.00
2.08
12.00
9.60
0.12
9.87
31.59
2.77
15.63
9.62
0.11
9.87
35.23
10
2.77
7.60
9.62
0.11
9.87
11
7.73
14.99
9.73
0.11
9.88
12
7.73
2.16
9.73
0.11
9.88
Over
Limit
Note: 1. Result Level = Read Level +LISN Factor + Pulse Limiter Factor + Cable loss.
2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit.
3. Test setup: RBW: 200 Hz (9 kHz—150 kHz), 9 kHz (150 kHz—30 MHz).
4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.
Page 19 of 29
Download: JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Mirror Download [FCC.gov]JBLGO2H Portable Bluetooth Speaker Test Report  Harman International Industries, Inc
Document ID3842866
Application IDCvI2GHiTgiWm39rDpOvsbw==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize29.38kB (367221 bits)
Date Submitted2018-05-08 00:00:00
Date Available2018-05-08 00:00:00
Creation Date2018-05-03 15:44:21
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2018-05-08 17:59:57
Document TitleTest report
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Administrator
Create Date                     : 2018:05:03 15:44:21+08:00
Modify Date                     : 2018:05:08 17:59:57+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2018:05:08 17:59:57+08:00
Format                          : application/pdf
Title                           : Microsoft Word - DDT-R18041303-1E2 GO2H FCC&IC ID Report BT EDR
Creator                         : Administrator
Document ID                     : uuid:c6416e4c-5fb2-420a-abd1-ee440a396cb3
Instance ID                     : uuid:b0132bb1-f112-4872-adc5-9890db1faaf6
Page Count                      : 19