A1430 802.11 a/b/g/n radio, Bluetooth Radio Function RF Exposure Info 2_SAR test plots for GSM850 Apple Inc.

Apple Inc. 802.11 a/b/g/n radio, Bluetooth Radio Function

Alternate Views: Download [PDF]
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 824.2 MHz; Duty Cycle: 1:4.00037
Medium parameters used: f = 825 MHz; σ = 0.966 mho/m; εr = 56.403; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Rear with 11mm/GPRS 2 slot_L ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 1.189 mW/g
Rear with 11mm/GPRS 2 slot_L ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 33.769 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 1.545 W/kg
SAR(1 g) = 0.980 mW/g; SAR(10 g) = 0.610 mW/g
Maximum value of SAR (measured) = 1.218 mW/g
0 dB = 1.220mW/g
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 836.6 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.978 mho/m; εr = 56.292; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Rear with 11mm/GPRS 2 slot_M ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 1.133 mW/g
Rear with 11mm/GPRS 2 slot_M ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 32.597 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 1.471 W/kg
SAR(1 g) = 0.930 mW/g; SAR(10 g) = 0.579 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.147 mW/g
0 dB = 1.150mW/g
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 848.8 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 848.8 MHz; σ = 0.99 mho/m; εr = 56.171; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Rear with 11mm/GPRS 2 slot_H ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 1.218 mW/g
Rear with 11mm/GPRS 2 slot_H ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 33.778 V/m; Power Drift = 0.0049 dB
Peak SAR (extrapolated) = 1.587 W/kg
SAR(1 g) = 1 mW/g; SAR(10 g) = 0.620 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.244 mW/g
0 dB = 1.240mW/g
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 848.8 MHz; Duty Cycle: 1:4.00037
Rear with 11mm/GPRS 2 slot_H ch/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm,
dz=5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.109 mW/g
Date: 12/9/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (1 slot); Frequency: 836.6 MHz; Duty Cycle: 1:8.30042
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.968 mho/m; εr = 53.249; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Rear with 11mm/GPRS 1 slot_M ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.530 mW/g
Rear with 11mm/GPRS 1 slot_M ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 22.516 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 0.682 W/kg
SAR(1 g) = 0.438 mW/g; SAR(10 g) = 0.283 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.544 mW/g
0 dB = 0.540mW/g
Date: 1/10/2012
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (TDMA, GMSK, 2 slot); Frequency: 836.6 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.989 mho/m; εr = 54.127; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3772; ConvF(8.57, 8.57, 8.57); Calibrated: 5/3/2011
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.8 (0);SEMCAD X Version 14.6.4 (4989)
Rear with 11mm/EGPRS 2 slot_M ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.383 mW/g
Rear with 11mm/EGPRS 2 slot_M ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 19.599 V/m; Power Drift = 0.18 dB
Peak SAR (extrapolated) = 0.5340
SAR(1 g) = 0.335 mW/g; SAR(10 g) = 0.210 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.418 mW/g
0 dB = 0.420mW/g = -7.54 dB mW/g
Date: 1/10/2012
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (TDMA, GMSK, 1 slot); Frequency: 836.6 MHz; Duty Cycle: 1:8.30042
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.989 mho/m; εr = 54.127; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3772; ConvF(8.57, 8.57, 8.57); Calibrated: 5/3/2011
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.8 (0);SEMCAD X Version 14.6.4 (4989)
Rear with 11mm/EGPRS 1 slot_M ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.212 mW/g
Rear with 11mm/EGPRS 1 slot_M ch /Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 14.106 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 0.2700
SAR(1 g) = 0.176 mW/g; SAR(10 g) = 0.111 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.224 mW/g
0 dB = 0.220mW/g = -13.15 dB mW/g
Date: 12/9/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 836.6 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.968 mho/m; εr = 53.249; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Top Edge/GPRS 2 slot_M ch/Area Scan (51x141x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.489 mW/g
Top Edge/GPRS 2 slot_M ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 18.824 V/m; Power Drift = 0.16 dB
Peak SAR (extrapolated) = 0.790 W/kg
SAR(1 g) = 0.397 mW/g; SAR(10 g) = 0.217 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.549 mW/g
0 dB = 0.550mW/g
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 836.6 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.978 mho/m; εr = 56.292; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Right Edge/GPRS 2 slot_M ch/Area Scan (51x191x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.342 mW/g
Right Edge/GPRS 2 slot_M ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 17.656 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 0.885 W/kg
SAR(1 g) = 0.347 mW/g; SAR(10 g) = 0.189 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.536 mW/g
0 dB = 0.540mW/g
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 824.2 MHz; Duty Cycle: 1:4.00037
Medium parameters used: f = 825 MHz; σ = 0.966 mho/m; εr = 56.403; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Rear/GPRS 2 slot_L ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.803 mW/g
Rear/GPRS 2 slot_L ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 26.850 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 1.532 W/kg
SAR(1 g) = 0.717 mW/g; SAR(10 g) = 0.370 mW/g
Maximum value of SAR (measured) = 0.957 mW/g
0 dB = 0.960mW/g
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 836.6 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.978 mho/m; εr = 56.292; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Rear/GPRS 2 slot_M ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.855 mW/g
Rear/GPRS 2 slot_M ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 27.515 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 1.618 W/kg
SAR(1 g) = 0.757 mW/g; SAR(10 g) = 0.389 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.004 mW/g
0 dB = 1.000mW/g
Date: 12/5/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 848.8 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 848.8 MHz; σ = 0.99 mho/m; εr = 56.171; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Rear/GPRS 2 slot_H ch/Area Scan (91x71x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.951 mW/g
Rear/GPRS 2 slot_H ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 28.803 V/m; Power Drift = 0.14 dB
Peak SAR (extrapolated) = 1.810 W/kg
SAR(1 g) = 0.858 mW/g; SAR(10 g) = 0.441 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.136 mW/g
0 dB = 1.140mW/g
Date: 12/7/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 836.6 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.975 mho/m; εr = 53.347; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Top Edge/GPRS_2 Slot_W/14mm Seperation_M ch/Area Scan (51x141x1): Measurement
grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.535 mW/g
Top Edge/GPRS_2 Slot_W/14mm Seperation_M ch/Zoom Scan (7x7x9)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 22.026 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.630 W/kg
SAR(1 g) = 0.428 mW/g; SAR(10 g) = 0.280 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.519 mW/g
0 dB = 0.520mW/g
Date: 12/7/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 824.2 MHz; Duty Cycle: 1:4.00037
Medium parameters used: f = 825 MHz; σ = 0.964 mho/m; εr = 53.476; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Top Edge/GPRS_2 Slot_L ch_Tilt 15 deg./Area Scan (51x141x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 0.948 mW/g
Top Edge/GPRS_2 Slot_L ch_Tilt 15 deg./Zoom Scan (7x7x9)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=3mm
Reference Value = 31.286 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 1.143 W/kg
SAR(1 g) = 0.789 mW/g; SAR(10 g) = 0.512 mW/g
Maximum value of SAR (measured) = 0.949 mW/g
0 dB = 0.950mW/g
Date: 12/7/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 836.6 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.975 mho/m; εr = 53.347; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Top Edge/GPRS_2 Slot_M ch_Tilt 15 deg./Area Scan (51x141x1): Measurement grid: dx=15mm,
dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.920 mW/g
Top Edge/GPRS_2 Slot_M ch_Tilt 15 deg./Zoom Scan (7x7x9)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=3mm
Reference Value = 30.537 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 1.111 W/kg
SAR(1 g) = 0.757 mW/g; SAR(10 g) = 0.490 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.915 mW/g
0 dB = 0.910mW/g
Date: 12/7/2011
Test Laboratory: UL CCS SAR Lab A
GSM850
Communication System: GPRS-FDD (2 slot); Frequency: 848.8 MHz; Duty Cycle: 1:4.00037
Medium parameters used (interpolated): f = 848.8 MHz; σ = 0.987 mho/m; εr = 53.216; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3749; ConvF(8.79, 8.79, 8.79); Calibrated: 12/13/2010
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 7/14/2011
- Phantom: ELI v4.0(A); Type: QDOVA001BB; Serial: 1119
- Measurement SW: DASY52, Version 52.6 (2);SEMCAD X Version 14.4.5 (3634)
Top Edge/GPRS_2 Slot_H ch_Tilt 15 deg./Area Scan (51x141x1): Measurement grid: dx=15mm,
dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.947 mW/g
Top Edge/GPRS_2 Slot_H ch_Tilt 15 deg./Zoom Scan (7x7x9)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=3mm
Reference Value = 30.799 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 1.144 W/kg
SAR(1 g) = 0.777 mW/g; SAR(10 g) = 0.500 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.947 mW/g
0 dB = 0.950mW/g
Download: A1430 802.11 a/b/g/n radio, Bluetooth Radio Function RF Exposure Info 2_SAR test plots for GSM850 Apple Inc.
Mirror Download [FCC.gov]A1430 802.11 a/b/g/n radio, Bluetooth Radio Function RF Exposure Info 2_SAR test plots for GSM850 Apple Inc.
Document ID1632865
Application IDhailpa+6C9XN92HJcRgiXQ==
Document DescriptionSAR GSM 850 Plots
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize52.59kB (657314 bits)
Date Submitted2012-02-07 00:00:00
Date Available2012-03-07 00:00:00
Creation Date2012-01-03 20:21:22
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2012-01-17 17:23:05
Document Title2_SAR test plots for GSM850
Document CreatorPScript5.dll Version 5.2.2
Document Author: 29446