SAR Exemption Evaluation Report
Product Name : ELEMNT Rival
Model No.
: WF119
FCC ID
: PADWF119
Applicant : Wahoo Fitness, LLC.
Address
: 90 W. Wieuca Road, #110, Atlanta, Georgia, 30342
United States
Date of Receipt : Sep. 18, 2017
Test Date
Sep. 18, 2017~ Oct. 26, 2017
Issued Date
: Nov. 10, 2017
Report No.
: 1792069R-RF-US-P20V02
Report Version : V1.0
The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by A2LA, TAF any agency of the government.
The test report shall not be reproduced without the written approval of DEKRA Testing & Certification (Suzhou)
Co., Ltd.
Report No: 1792069R-RF-US-P20V02
Tes t R e p o r t C e r t i f i c a t i o n
Issued Date : Nov. 10, 2017
Report No. : 1792069R-RF-US-P20V02
Product Name
ELEMNT Rival
Applicant
Wahoo Fitness, LLC.
Address
90 W. Wieuca Road, #110, Atlanta, Georgia, 30342
United States
Manufacturer
Wahoo Fitness, LLC.
Address
90 W. Wieuca Road, #110, Atlanta, Georgia, 30342
United States
Model No.
WF119
FCC ID
PADWF119
EUT Voltage
DC 3.7V
Applicable Standard
KDB 447498 D01v06
Test Result
Complied
Performed Location
DEKRA Testing & Certification (Suzhou) Co., Ltd.
No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
215006, Jiangsu, China
TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
FCC Designation Number: CN1199
Documented By
(Project Assistant: Wendy Yu)
Reviewed By
(Engineering Supervisor: Jack Zhang)
Approved By
(Engineering Manager : Harry Zhao )
Page: 2 of 4
Report No: 1792069R-RF-US-P20V02
1. RF Exposure Evaluation
1.1. Limits
According to KDB 447498 D01 General RF Exposure Guidance v06
4.3.1 Standalone SAR test exclusion considerations
1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)]
≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where
• f(GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation
• The result is rounded to one decimal place for comparison
• 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.
2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
determined according to the following, and as illustrated in Appendix B:
a) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·( f(MHz)/150)] mW, at 100 MHz to 1500 MHz
b) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·10] mW at > 1500 MHz and ≤ 6 GHz
3) The 1-g and 10-g SAR test exclusion thresholds for below 100 MHz at test separation distances ≤ 50 mm
are determined by:
a) The power threshold at the corresponding test separation distance at 100 MHz in step 2) is
multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm
b) The power threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
separation distances ≤ 50 mm
c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be
applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be
acceptable. Note: when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
determine SAR test exclusion.
Page: 3 of 4
Report No: 1792069R-RF-US-P20V02
1.2. Test Procedure
Software provided by client enabled the EUT to transmit and receive data at lowest, middle
and highest channel individually.
The temperature and related humidity: 18℃and 78% RH.
1.3. Test Result of RF Exposure Evaluation
Product
ELEMNT Rival
Test Item
RF Exposure Evaluation
Test Site
AC-6

Antenna Gain:
No. Manufacturer
Part No.
Antenna Type
Peak Gain
N/A
PIFA
-1.1dBi
N/A
Based on The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm and the formula below:
Band
BT
Exposure
Condition
Body
Pmax Pmax
Stand-alone
Distance
f(GHz)
(dBm)
(mw)
(mm)
2.860
1.932
calculation
Test
result
exclusion
SAR Test
threshold
2.402
Conclusion: 2.4GHz SAR was not required.
The End
Page: 4 of 4
0.60
3.00
No
Download: WF119 ELEMNT Rival (multisport gps heart rate watch) RF Exposure Info  Wahoo Fitness LLC
Mirror Download [FCC.gov]WF119 ELEMNT Rival (multisport gps heart rate watch) RF Exposure Info  Wahoo Fitness LLC
Document ID3665025
Application IDgqTGgfENUReW05pl+9+bdA==
Document Description1792069R-FCC statement for SAR not required-ELEMNT Rival-WF119-V1.0-2017-11-30
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize9.28kB (116049 bits)
Date Submitted2017-12-06 00:00:00
Date Available2017-11-23 00:00:00
Creation Date2017-11-29 16:16:43
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-11-29 16:16:43
Document TitleRF Exposure Info

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Create Date                     : 2017:11:29 16:16:43+08:00
Modify Date                     : 2017:11:29 16:16:43+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : untitled
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:8b0335ca-f959-4a8f-a5d1-0c942f73453b
Instance ID                     : uuid:45ccc0db-7711-477e-9b7b-721358d19bc4
Page Count                      : 4