RF TEST REPORT
Applicant Huawei Technologies Co., Ltd.
FCC ID QISR218H
Product Mobile WiFi
Model R218h
Report No. RHA1705-0045RF01
Issue Date May 23, 2017
TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
CFR47 Part 2 (2017)/ FCC CFR 47 Part 22H (2017). The test results show that the equipment tested is
capable of demonstrating compliance with the requirements as documented in this report.
Performedby:JiangpengLan
Approvedby:KaiXu
TA Technology (Shanghai) Co., Ltd.
No.145,JintangRd,TangzhenIndustryPark,PudongShanghai,China
TEL:+8602150791141/2/3
FAX:+8602150791141/2/38000
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 2 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
TABLE OF CONTENT
1.Test Laboratory ...................................................................................................................................... 4
1.1.Notes of the Test Report ............................................................................................................... 4
1.2.Test facility ..................................................................................................................................... 4
1.3.Testing Location ............................................................................................................................ 5
2.General Description of Equipment under Test ....................................................................................... 6
3.Applied Standards .................................................................................................................................. 9
4.Test Configuration ................................................................................................................................ 10
5.Test Case Results ................................................................................................................................ 11
5.1.RF Power Output ......................................................................................................................... 11
5.2.Effective Radiated Power ............................................................................................................ 13
5.3.Occupied Bandwidth ................................................................................................................... 16
5.4.Band Edge Compliance ............................................................................................................... 20
5.5.Peak-to-Average Power Ratio (PAPR) ....................................................................................... 22
5.6.Frequency Stability ...................................................................................................................... 24
5.7.Spurious Emissions at Antenna Terminals ................................................................................. 27
5.8.Radiates Spurious Emission ....................................................................................................... 29
6.Main Test Instruments ......................................................................................................................... 33
ANNEX A: EUT Appearance and Test Setup .............................................................................................. 34
A.1 EUT Appearance ......................................................................................................................... 34
A.2 Test Setup .................................................................................................................................... 35
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 3 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Summary of measurement results
No. Test Type Clause in FCC rules Verdict
1 RF power output 2.1046 PASS
2 Effective Radiated Power 22.913(a)(2) PASS
3 Occupied Bandwidth 2.1049 PASS
4 Band Edge Compliance 2.1051 / 22.917(a) PASS
5 Peak-to-Average Power Ratio 22.913(d)/
KDB 971168 D01(5.7) PASS
6 Frequency Stability 2.1055 / 22.355 PASS
7 Spurious Emissions at Antenna Terminals 2.1051 / 22.917(a) PASS
8 Radiates Spurious Emission 2.1053 / 22.917 (a) PASS
Date of Testing: May 9, 2017 ~ May 18, 2017
Note: PASS: The EUT complies with the essential requirements in the standard.
FAIL: The EUT does not comply with the essential requirements in the standard.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 4 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
1. Test Laboratory
1.1. Notes of the Test Report
This report shall not be reproduced in full or partial, without the written approval of TA technology
(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein .Measurement Uncertainties were not taken
into account and are published for informational purposes only. This report is written to support
regulatory compliance of the applicable standards stated above. This report must not be used by the
client to claim product certification, approval, or endorsement by any government agencies.
1.2. Test facility
CNAS (accreditation number: L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (recognition number is 428261)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 5 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
1.3. Testing Location
Company: TA Technology (Shanghai) Co., Ltd.
Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong
City: Shanghai
Post code: 201201
Country: P. R. China
Contact: Xu Kai
Telephone: +86-021-50791141/2/3
Fax: +86-021-50791141/2/3-8000
Website: http://www.ta-shanghai.com
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 6 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
2. General Description of Equipment under Test
Client Information
Applicant Huawei Technologies Co., Ltd.
Applicant address
Administration Building, Headquarters of Huawei Technologies
Co., Ltd., Bantian, Longgang District
Shenzhen
518129
P.R.China
Manufacturer Huawei Technologies Co., Ltd.
Manufacturer address
Administration Building, Headquarters of Huawei Technologies
Co., Ltd., Bantian, Longgang District
Shenzhen
518129
P.R.China
General Information
EUT Description
Model: R218h
Product IMEI /
Hardware Version CL1E5573CSM16
Software Version 21.326.06.00.11
Power Supply Battery/AC adapter
Antenna Type Internal Antenna
Test Mode(s) GSM 850
Test Modulation (GSM)GMSK,8PSK;
GPRS Multislot Class 12
EGPRS Multislot Class 12
Maximum E.R.P. GSM 850: 29.25 dBm
Rated Power Supply Voltage 3.8V
Extreme Voltage Minimum: 3.6V Maximum: 4.2V
Extreme Temperature Lowest: 0°C Highest: +35°C
Operating Frequency Range(s) Band Tx (MHz) Rx (MHz)
GSM850 824 ~ 849 869 ~ 894
EUT Accessory
Adapter 1
Manufacturer: Dongguan Phitek Electronic Co., Ltd
Model: HW-050100E01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 2 Manufacturer: Huizhou BYD Electronic Co., Ltd
Model: HW-050100E01
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 7 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 3
Manufacturer: Shenzhen Huntkey Electric Co., Ltd.
Model: HW-050100E01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 4
Manufacturer: Dongguan Phitek Electronic Co., Ltd
Model: HW-050100U01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 5
Manufacturer: Huizhou BYD Electronic Co., Ltd
Model: HW-050100U01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 6
Manufacturer: Shenzhen Huntkey Electric Co., Ltd.
Model: HW-050100U01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 7
Manufacturer: Dongguan Phitek Electronic Co., Ltd
Model: HW-050100B01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 8
Manufacturer: Huizhou BYD Electronic Co., Ltd
Model: HW-050100B01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 9
Manufacturer: Shenzhen Huntkey Electric Co., Ltd.
Model: HW-050100B01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 10
Manufacturer: Dongguan Phitek Electronic Co., Ltd
Model: HW-050100A01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 11
Manufacturer: Huizhou BYD Electronic Co., Ltd
Model: HW-050100A01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Adapter 12
Manufacturer: Shenzhen Huntkey Electric Co., Ltd.
Model: HW-050100A01
Input power: 100-240V AC 50/60Hz 0.2A
Output power: 5V DC 1A
Battery 1 Manufacturer: Sunwoda Electronic Co.,LTD
Model: HB434666RBC
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 8 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Power Rating: DC 3.8V, 1500mAh, Li-ion
Battery 2
Manufacturer: SCUD (Fujian) Electronics Co., LTD
Model: HB434666RBC
Power Rating: DC 3.8V, 1500mAh, Li-ion
USB Extend Cable 100cm Cable, Shielded
Note: The information of the EUT is declared by the manufacturer.
Please refer to the specifications or user manual for details.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 9 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
3. Applied Standards
According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:
FCC CFR47 Part 2 (2017)
FCC CFR 47 Part 22H (2017)
ANSI/TIA-603-D (2010)
KDB 971168 D01 Power Meas License Digital Systems v02r02
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 10 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
4. Test Configuration
Radiated measurements are performed by rotating the EUT in three different orthogonal test planes.
EUT stand-up position (Z axis), lie-down position (X, Y axis). Receiver antenna polarization
(horizontal and vertical), the worst emission was found in position (Z axis, vertical polarization) and
the worst case was recorded.
Test modes are chosen to be reported as the worst case configuration below:
Test items Modes/Modulation
GSM 850
Conducted
Test cases
RF power output
GSM
GPRS (1Tx slot)
EGPRS (1Tx slot)
Occupied Bandwidth
GSM
GPRS (1Tx slot)
EGPRS (1Tx slot)
Band Edge Compliance
GSM
GPRS (1Tx slot)
EGPRS (1Tx slot)
Peak-to-Average Power Ratio
GSM
GPRS (1Tx slot)
EGPRS (1Tx slot)
Frequency Stability
GSM
GPRS (1Tx slot)
EGPRS (1Tx slot)
Spurious Emissions at Antenna
Terminals GSM
Radiated
Test cases
Effective Radiated Power
GSM
GPRS (1Tx slot)
EGPRS (1Tx slot)
Radiates Spurious Emission GSM
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 11 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5. Test Case Results
5.1. RF Power Output
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Methods of Measurement
During the process of the testing, The EUT is controlled by the Base Station Simulator to ensure max
power transmission and proper modulation.
Test Setup
The loss between RF output port of the EUT and the input port of the tester has been taken into
consideration.
Limits
No specific RF power output requirements in part 2.1046.
Measurement Uncertainty
The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 0.4 dB.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 12 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Results
GSM 850
Conducted Power(dBm)
Channel 128 Channel 190 Channel 251
824.2 (MHz) 836.6 (MHz) 848.8 (MHz)
GSM Results 31.82 31.96 31.94
GPRS
(GMSK)
1TXslot 31.83 31.92 32.06
2TXslots 29.70 29.89 29.98
3TXslots 27.59 27.70 27.83
4TXslots 25.46 25.67 25.70
EGPRS
(8PSK)
1TXslot 26.08 26.18 25.92
2TXslots 23.65 23.80 23.88
3TXslots 21.67 21.79 21.75
4TXslots 19.39 19.47 19.58
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 13 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5.2. Effective Radiated Power
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Methods of Measurement
1. The testing follows FCC KDB 971168 v02r02 Section 5.8 and ANSI / TIA-603-D-2010 Section
2.2.12.
2. EUT was placed on a 0.8 meter high non-conductive stand at a 3 meter test distance from the
receive antenna. A receiving antenna was placed on the antenna mast 3 meters from the EUT for
emission measurements. The height of receiving antenna beteen 1.0m and 4.0m. Detected
emissions were maximized at each frequency by rotating the EUT through 360° and adjusting the
receiving antenna polarization. The radiated emission measurements of all transmit frequencies in
three channels (High, Middle, Low) were measured with peak detector.
3. A log-periodic antenna or double-ridged waveguide horn antenna shall be substituted in place of
the EUT. The log-periodic antenna will be driven by a signal generator and the level will be adjusted
till the same power value on the spectrum analyzer or receiver. The level of the spurious emissions
can be calculated through the level of the signal generator, cable loss, the gain of the substitution
antenna and the reading of the spectrum analyzer or receiver.
4. The EUT is then put into continuously transmitting mode at its maximum power level during the
test.Set Test Receiver or Spectrum RBW=1MHz,VBW=3MHz for above 1GHz and
RBW=100kHz,VBW=300kHz for 30MHz to 1GHz,, And the maximum value of the receiver should be
recorded as (Pr).
5. The EUT shall be replaced by a substitution antenna. In the chamber, an substitution antenna for
the frequency band of interest is placed at the reference point of the chamber. An RF Signal source
for the frequency band of interest is connected to the substitution antenna with a cable that has been
constructed to not interfere with the radiation pattern of the antenna. A power (PMea) is applied to the
input of the substitution antenna, and adjust the level of the signal generator output until the value of
the receiver reach the previously recorded (Pr). The power of signal source (PMea) is recorded. The
test should be performed by rotating the test item and adjusting the receiving antenna polarization.
6. A amplifier should be connected to the Signal Source output port. And the cable should be connect
between the Amplifier and the Substitution Antenna. The cable loss (Pcl) ,the Substitution Antenna
Gain (Ga) and the Amplifier Gain (PAg) should be recorded after test.
7. The measurement results are obtained as described below:
Power(EIRP)=PMea- PAg - Pcl + Ga
The measurement results are amend as described below:
Power(EIRP)=PMea- Pcl + Ga
8. This value is EIRP since the measurement is calibrated using an antenna of known gain (2.15 dBi)
and known input power. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP
= EIRP-2.15dBi.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 14 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test configuration
Below 1GHz:
Above 1GHz:
Limits
Rule Part 22.913(a) specifies that "Mobile/portable stations are limited to 7 watts ERP”.
Limit 7 W (38.45 dBm)
Measurement Uncertainty
The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 1.19 dB
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 15 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Results:
Mode Polarization Frequency
(MHz)
Rt
(dBm)
Rs
(dBm)
Ps
(dBm)
Gs
(dBd)
ERP
(dBm)
Limit
(dBm) Conclusion
GSM
850
H 824.2 -19.81 -45.53 0.00 1.06 26.78 38.45 Pass
H 836.6 -18.42 -45.38 0.00 1.24 28.20 38.45 Pass
H 848.8 -17.50 -45.37 0.00 1.38 29.25 38.45 Pass
V 824.2 -41.51 -45.65 0.00 1.06 5.20 38.45 Pass
V 836.6 -39.87 -45.46 0.00 1.24 6.83 38.45 Pass
V 848.8 -39.49 -45.49 0.00 1.38 7.38 38.45 Pass
GPRS
850
H 824.2 -26.33 -45.53 0.00 1.06 20.26 38.45 Pass
H 836.6 -24.74 -45.38 0.00 1.24 21.88 38.45 Pass
H 848.8 -23.63 -45.37 0.00 1.38 23.12 38.45 Pass
V 824.2 -48.08 -45.65 0.00 1.06 -1.37 38.45 Pass
V 836.6 -46.32 -45.46 0.00 1.24 0.38 38.45 Pass
V 848.8 -45.73 -45.49 0.00 1.38 1.14 38.45 Pass
EGPRS
850
H 824.2 -28.92 -45.53 0.00 1.06 17.67 38.45 Pass
H 836.6 -27.46 -45.38 0.00 1.24 19.16 38.45 Pass
H 848.8 -26.44 -45.37 0.00 1.38 20.31 38.45 Pass
V 824.2 -48.77 -45.65 0.00 1.06 -2.06 38.45 Pass
V 836.6 -47.50 -45.46 0.00 1.24 -0.80 38.45 Pass
V 848.8 -47.14 -45.49 0.00 1.38 -0.27 38.45 Pass
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 16 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5.3. Occupied Bandwidth
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Method of Measurement
The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
occupied bandwidth is measured using spectrum analyzer.
RBW is set to 3kHz, VBW is set to 10kHz for GSM 850,
99% power and -26dBc occupied bandwidths are recorded. Spectrum analyzer plots are included on
the following pages.
Test Setup
Limits
No specific occupied bandwidth requirements in part 2.1049.
Measurement Uncertainty
The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 624Hz.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 17 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Result
Mode Channel Frequency (MHz) 99% Power
Bandwidth (MHz)
-26dBc
Bandwidth(MHz)
GSM 850
(GSM)
128 824.2 0.24222 0.3085
190 836.6 0.24341 0.3060
251 848.8 0.24467 0.3082
GPRS 850
(GMSK)
128 824.2 0.24564 0.3125
190 836.6 0.24540 0.3120
251 848.8 0.24349 0.3148
EGPRS 850
(8-PSK)
128 824.2 0.24412 0.3157
190 836.6 0.24586 0.3110
251 848.8 0.24325 0.3145
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 18 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
GSM 850 CH-Low GSM 850 GPRS CH-Low
GSM 850 CH-Middle GSM 850 GPRS CH-Middle
GSM 850 CH-High GSM 850 GPRS CH-High
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 19 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
GSM 850 EGPRS CH-Low GSM 850 EGPRS CH-Middle
GSM 850 EGPRS CH-High
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 20 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5.4. Band Edge Compliance
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Method of Measurement
The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
band edge of the lowest and highest channels were measured. The average detector is used.
RBW is set to 3kHz,VBW is set to 10kHz for GSM 850,
Spectrum analyzer plots are included on the following pages.
Test Setup
Limits
Rule Part 22.917(a) specifies that “The power of any emission outside of the authorized operating
frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10
log(P) dB.”
Limit -13 dBm
Measurement Uncertainty
The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96, U=0.684dB.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 21 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Result:
GSM 850 CH-Low GSM 850 CH-High
GSM 850 GPRS CH-Low GSM 850 GPRS CH-High
GSM 850 EGPRS CH-Low GSM 850 EGPRS CH-High
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 22 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5.5. Peak-to-Average Power Ratio (PAPR)
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Methods of Measurement
Measure the total peak power and record as PPk. And measure the total average power and record as
PAvg. Both the peak and average power levels must be expressed in the same logarithmic units (e.g.,
dBm). Determine the PAPR from:
PAPR (dB) = PPk (dBm) - PAvg (dBm).
Test Setup
Limits
According to the Sec. 22.913(d), The peak-to-average ratio (PAR) of the transmission must not
exceed 13 dB.
Measurement Uncertainty
The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 0.4 dB.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 23 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Results
Mode Channel Frequency
(MHz)
Peak
(dBm)
Avg
(dBm)
PAPR
(dB)
Limit
(dB) Conclusion
GSM 850
(GSM)
128 824.2 33.67 31.82 1.85 13 PASS
190 836.6 33.67 31.96 1.71 13 PASS
251 848.8 34.11 31.94 2.17 13 PASS
GPRS 850
(GMSK)
128 824.2 27.27 25.46 1.81 13 PASS
190 836.6 27.32 25.67 1.65 13 PASS
251 848.8 27.38 25.70 1.68 13 PASS
EGPRS 850
(8-PSK)
128 824.2 20.88 19.39 1.49 13 PASS
190 836.6 20.81 19.47 1.34 13 PASS
251 848.8 20.77 19.58 1.19 13 PASS
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 24 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5.6. Frequency Stability
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Method of Measurement
1. Frequency Stability (Temperature Variation)
The temperature inside the climate chamber is varied from -30°C to +50°C in 10°C step size,
(1) With all power removed, the temperature was decreased to 0°C and permitted to stabilize for
three hours.
(2) Measure the carrier frequency with the test equipment in a “call mode”. These measurements
should be made within 1 minute of powering up the mobile station, to prevent significant self
warming.
(3) Repeat the above measurements at 10°C increments from -30°C to +50°C. Allow at least 1.5
hours at each temperature, un-powered, before making measurements. Frequency Stability
(Voltage Variation)
The frequency stability shall be measured with variation of primary supply voltage as follows:
(1) Vary primary supply voltage from 85 to 115 percent of the nominal value for other than hand
carried battery equipment.
(2) For hand carried, battery powered equipment, reduce primary supply voltage to the
battery-operating end point which shall be specified by the manufacturer.
This transceiver is specified to operate with an input voltage of between 3.6 V and 4.2 V, with a
nominal voltage of 3.8V.
Test setup
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 25 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Limits
According to the Sec. 22.355, the frequency stability of the carrier shall be accurate to within 2.5 ppm
of the received frequency for mobile stations.
Limits 2.5 ppm
Measurement Uncertainty
The assessed measurement uncertainty to ensure 99.75 confidence level for the normal
distribution is with the coverage factor k = 3, U= 0.01ppm.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 26 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Result
Mode Test status
Test Results (ppm) Limit
(ppm) Conclusion
GSM
(GMSK)
GPRS
(GMSK)
EGPRS
(8PSK)
GSM 850
Middle Channel
50°C/Normal Voltage -0.0119 0.0320 0.0311 2.5 PASS
40°C/Normal Voltage -0.0150 0.0266 0.0244 2.5 PASS
30°C/Normal Voltage -0.0090 0.0264 0.0221 2.5 PASS
20°C/Normal Voltage -0.0113 0.0326 0.0254 2.5 PASS
10°C/Normal Voltage -0.0095 0.0295 0.0234 2.5 PASS
0°C/Normal Voltage -0.0123 0.0259 0.0293 2.5 PASS
-10°C/Normal Voltage -0.0133 0.0301 0.0228 2.5 PASS
-20°C/Normal Voltage -0.0117 0.0284 0.0218 2.5 PASS
-30°C/Normal Voltage -0.0107 0.0264 0.0293 2.5 PASS
20°C/Minimum Voltage -0.0118 0.0267 0.0266 2.5 PASS
20°C/Maximum Voltage -0.0073 0.0304 0.0211 2.5 PASS
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 27 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5.7. Spurious Emissions at Antenna Terminals
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Method of Measurement
The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
measurement is carried out using a spectrum analyzer. The spectrum analyzer scans from 9kHz to
the 10th harmonic of the carrier. The peak detector is used. RBW are set to 100 kHz and VBW are set
to 300 kHz for below 1G, RBW are set to 1MHz and VBW are set to 3MHz for above 1G, Sweep is set
to ATUO.
Test setup
Limits
Rule Part 22.917(a) specifies that “The power of any emission outside of the authorized operating
frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10
log (P) dB.”
Limit -13 dBm
Measurement Uncertainty
The assessed measurement uncertainty to ensure 99.75% confidence level for the normal
distribution is with the coverage factor k = 1.96.
Frequency Uncertainty
100kHz-2GHz 0.684 dB
2GHz-12.75GHz 1.407 dB
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 28 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Result
Sweep from 9 kHz to 30MHz, and the emissions more than 20 dB below the permissible value are not
reported.
If disturbances were found more than 20dB below limit line, the mark is not required for the EUT.
The signal beyond the limit is carrier.
GSM 850 CH-Low 30MHz~9GHz
-80
-75
-70
-65
-60
-55
-50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
.03 1 2 3 4 5 6 7 8 9
Level in dBm
Frequency in GHz
FCC CSE
GSM 850 CH-Middle 30MHz~9GHz
-80
-75
-70
-65
-60
-55
-50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
.03 1 2 3 4 5 6 7 8 9 10
Level in dBm
Frequency in GHz
FCC CSE
GSM 850 CH-High 30MHz~9GHz
-80
-75
-70
-65
-60
-55
-50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
.03 1 2 3 4 5 6 7 8 9
Level in dBm
Frequency in GHz
FCC CSE
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 29 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
5.8. Radiates Spurious Emission
Ambient condition
Temperature Relative humidity Pressure
23°C ~25°C 45%~50% 101.5kPa
Method of Measurement
1. The testing follows FCC KDB 971168 v02r02 Section 5.8 and ANSI / TIA-603-D-2010 Section
2.2.12.
2. Above 30MHzThe EUT is placed on a turntable 0.8 meters above the ground in the chamber, 3
meter away from the antenna. The maximal emission value is acquired by adjusting the antenna
height, polarisation and turntable azimuth. Normally, the height range of antenna is 1 m to 4 m, the
azimuth range of turntable is 0° to 360°, and the receive antenna has two polarizations Vertical (V)
and Horizontal (H). Above 1GHz: (Note: the FCC’s permission to use 1.5m as an alternative per
TCBC Conf call of Dec. 2, 2014.) The EUT is placed on a turntable 1.5 meters above the ground in
the chamber, 3 meter away from the antenna. The maximal emission value is acquired by adjusting
the antenna height, polarisation and turntable azimuth. Normally, the height range of antenna is 1 m
to 4 m, the azimuth range of turntable is 0° to 360°, and the receive antenna has two polarizations
Vertical (V) and Horizontal (H).
3. A log-periodic antenna or double-ridged waveguide horn antenna shall be substituted in place of
the EUT. The log-periodic antenna will be driven by a signal generator and the level will be adjusted
till the same power value on the spectrum analyzer or receiver. The level of the spurious emissions
can be calculated through the level of the signal generator, cable loss, the gain of the substitution
antenna and the reading of the spectrum analyzer or receiver.
4. The EUT is then put into continuously transmitting mode at its maximum power level during the
test.Set Test Receiver or Spectrum RBW=1MHz,VBW=3MHz for above 1GHz and
RBW=100kHz,VBW=300kHz for 30MHz to 1GHz,, And the maximum value of the receiver should be
recorded as (Pr).
5. The EUT shall be replaced by a substitution antenna. In the chamber, an substitution antenna for
the frequency band of interest is placed at the reference point of the chamber. An RF Signal source
for the frequency band of interest is connected to the substitution antenna with a cable that has been
constructed to not interfere with the radiation pattern of the antenna. A power (PMea) is applied to the
input of the substitution antenna, and adjust the level of the signal generator output until the value of
the receiver reach the previously recorded (Pr). The power of signal source (PMea) is recorded. The
test should be performed by rotating the test item and adjusting the receiving antenna polarization.
6. A amplifier should be connected to the Signal Source output port. And the cable should be connect
between the Amplifier and the Substitution Antenna. The cable loss (Pcl) ,the Substitution Antenna
Gain (Ga) and the Amplifier Gain (PAg) should be recorded after test.
7. The measurement results are obtained as described below:
Power(EIRP)=PMea- PAg - Pcl + Ga
The measurement results are amend as described below:
Power(EIRP)=PMea- Pcl + Ga
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 30 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
8. This value is EIRP since the measurement is calibrated using an antenna of known gain (2.15 dBi)
and known input power. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP
= EIRP-2.15dBi.
Test setup
30MHz~~~ 1GHz
Above 1GHz
Note: Area side:2.4mX3.6m
Limits
Rule Part 22.917(a) specifies that “The power of any emission outside of the authorized operating
frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10
log (P) dB.”
Limit -13 dBm
Measurement Uncertainty
The assessed measurement uncertainty to ensure 95 confidence level for the normal distribution is
with the coverage factor k = 1.96, U= 3.55 dB.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 31 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
Test Result
GSM 850 CH-Low
Harmonic Frequency
(MHz)
SG
(dBm)
Cable
Loss
(dB)
Gain
(dBi)
Antenna
Polarization
ERP
Level
(dBm)
Limit
(dBm)
Margin
(dB)
Azimuth
(deg)
2 1648.5 -59.2 2 10.15 Vertical -53.2 -13 40.2 45
3 2472.7 -56.49 2.51 11.35 Vertical -49.8 -13 36.8 225
4 3296.8 -61.3 4.2 10.85 Vertical -56.8 -13 43.8 45
5 4121.0 -58.4 5.2 11.35 Vertical -54.4 -13 41.4 225
6 4945.2 -58.1 5.5 11.95 Vertical -53.8 -13 40.8 90
7 5769.4 -57 5.7 13.55 Vertical -51.3 -13 38.3 135
8 6593.6 -56 6.3 13.75 Vertical -50.7 -13 37.7 45
9 7417.8 -50.9 6.8 13.85 Vertical -46.0 -13 33.0 90
10 8242.0 -53 6.9 14.25 Vertical -47.8 -13 34.8 45
Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
2.The worst emission was found in the antenna is vertical position.
GSM 850 CH-Middle
Harmonic Frequency
(MHz)
SG
(dBm)
Cable
Loss
(dB)
Gain
(dBi)
Antenna
Polarization
ERP
Level
(dBm)
Limit
(dBm)
Margin
(dB)
Azimuth
(deg)
2 1673.3 -60.1 2 10.75 Vertical -53.5 -13 40.5 135
3 2509.8 -53.19 2.51 11.05 Vertical -46.8 -13 33.8 90
4 3346.4 -60.8 4.2 11.15 Vertical -56.0 -13 43.0 45
5 4183.0 -60.3 5.2 11.15 Vertical -56.5 -13 43.5 90
6 5019.6 -55.7 5.5 11.95 Vertical -51.4 -13 38.4 225
7 5856.2 -58.5 5.7 13.55 Vertical -52.8 -13 39.8 0
8 6692.8 -53.9 6.3 13.75 Vertical -48.6 -13 35.6 90
9 7529.4 -53.1 6.8 13.85 Vertical -48.2 -13 35.2 0
10 8366.0 -52.2 6.9 14.25 Vertical -47.0 -13 34.0 315
Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
2.The worst emission was found in the antenna is vertical position.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 32 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
GSM 850 CH-High
Harmonic Frequency
(MHz)
SG
(dBm)
Cable
Loss
(dB)
Gain
(dBi)
Antenna
Polarization
ERP
Level
(dBm)
Limit
(dBm)
Margin
(dB)
Azimuth
(deg)
2 1697.3 -60.2 2 10.15 Vertical -54.2 -13 41.2 45
3 2546.6 -52.39 2.51 11.05 Vertical -46.0 -13 33.0 225
4 3395.2 -61.2 4.2 11.15 Vertical -56.4 -13 43.4 45
5 4244.0 -59.4 5.2 11.15 Vertical -55.6 -13 42.6 225
6 5092.8 -56.9 5.5 11.95 Vertical -52.6 -13 39.6 90
7 5941.6 -57.5 5.7 13.55 Vertical -51.8 -13 38.8 135
8 6790.4 -54.6 6.3 13.75 Vertical -49.3 -13 36.3 45
9 7639.2 -53.3 6.8 13.85 Vertical -48.4 -13 35.4 90
10 8488.0 -53.6 6.9 14.25 Vertical -48.4 -13 35.4 45
Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
FCC RF Test Report Report No: RHA1705-0045RF01
TA Technology (Shanghai) Co., Ltd. Page 33 of 35
Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofTATechnology(Shanghai)Co.,Ltd.
6. Main Test Instruments
Name Type Manufacturer Serial
Number
Calibration
Date
Expiration
Time
Base Station
Simulator CMW500 R&S 113645 2016-05-21 2017-05-20
Power Splitter SHX-GF2-2-13 Hua Xiang 10120101 2016-05-21 2017-05-20
Spectrum
Analyzer N9010A Agilent MY47191109 2016-05-21 2017-05-20
Universal Radio
Communication
Tester
E5515C Agilent MY48367192 2016-05-21 2017-05-20
Signal Analyzer FSV30 R&S 100815 2016-12-16 2017-12-15
Signal generator SMB 100A R&S 102594 2016-05-22 2017-05-21
Signal generator SMR27 R&S 100365 2016-05-22 2017-05-21
EMI Test Receiver ESCI R&S 100948 2016-06-01 2017-05-31
Trilog Antenna VUBL 9163 SCHWARZBE
CK 9163-201 2014-12-06 2017-12-05
Trilog Antenna VUBL 9163 SCHWARZBE
CK 9163-391 2014-12-06 2017-12-05
Horn Antenna HF907 R&S 100126 2014-12-06 2017-12-05
Horn Antenna HF907 R&S 100125 2014-12-06 2017-12-05
Climatic Chamber PT-30B Re Ce 20101891 2015-07-18 2018-07-17
RF Cable SMA 15cm Agilent 0001 2017-02-06 2017-08-05
*****END OF REPORT *****
Download: R218H Mobile WiFi Test Report TestReport Part22 Huawei Technologies Co.,Ltd
Mirror Download [FCC.gov]R218H Mobile WiFi Test Report TestReport Part22 Huawei Technologies Co.,Ltd
Document ID3463368
Application IDQglzIA9fCNAKGtdVTAakVA==
Document DescriptionTestReport Part22
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize74.96kB (937030 bits)
Date Submitted2017-07-13 00:00:00
Date Available2017-07-13 00:00:00
Creation Date2017-07-03 11:40:25
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-07-12 16:56:46
Document TitleTestReport Part22
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Administrator
Create Date                     : 2017:07:03 11:40:25+08:00
Modify Date                     : 2017:07:12 16:56:46+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Title                           : Microsoft Word - RHA1705-0045RF01 HUAWEI_R218h Part22.doc
Creator                         : Administrator
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:07:12 16:56:46+08:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:618f4779-119f-42d8-8b99-18c867644e50
Instance ID                     : uuid:18aa45aa-990f-44a3-8846-2c27d3e95587
Page Count                      : 33
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2018