EXA51 / EXA51e RF safety training
NORDIC ID EXA51 / EXA51E RF SAFETY TRAINING
INTENTION AND PURPOSE OF THIS DOCUMENT IS TO GIVE INFORMATION OF CORRECT
AND SAFE USE OF NORDIC ID EXA51. THIS GUIDELINE IS TO NORDIC ID PARTNERS,
RESELLERS AND ESPECIALLY END CUSTOMERS WHO WILL USE THIS PRODUCT IN THEIR
WORK.
The product/system described in this documentation may be operated only by personnel qualified
for the specific task in accordance with the relevant documentation, its warning notices and safety
instructions. Qualified personnel are those who, based on their training and experience, can
identify risks and avoiding potential hazards when working with these products/systems.
Nordic ID products may only be used for the applications described in the user manual and in the
relevant technical documentation. If products and components from other manufacturers are used,
these must be recommended or approved by Nordic ID. Proper transport, storage, installation,
assembly, commissioning, operation and maintenance are required to ensure that the products
operate safely and without any problems. The permissible ambient conditions must be complied
with. The information in the relevant documentation must be observed.
Also with This information users will increase their awareness and knowledge of nordic id EXA51 /
EXA51e RF (radio Frequency) safety. this material will be part of partner, reseller and end customer
training packet.
NOTICE
Forfeiture of approvals and guarantees
Alterations to the devices are not permitted.
Failure to observe this requirement shall constitute a revocation of the radio equipment
approvals and manufacturer's warranty.
WARNING
Repairs only by authorized qualified personnel
Unauthorized opening of and improper repairs to the device may result in
substantial damage to equipment or danger. Repairs may only be carried out by
authorized qualified personnel.
Document: 3
1/4
2018-01-09
EXA51 / EXA51e RF safety training
TABLE OF CONTENTS
IMPORTANT INFORMATION WHEN USE NORDIC ID EXA51 ................................................................................ 3
SAFETY AND REGULATIONS....................................................................................................................... 3
QUICK GUIDE................................................................................................................................... 3
Document: 3
2/4
2018-01-09
EXA51 / EXA51e RF safety training
IMPORTANT INFORMATION WHEN USE NORDIC ID EXA51 / EXA51e
Nordic ID EXA51 / EXA51e includes two radio modules which comply IC rules & requlations related to
human exposure. To avoid unnecessary RF exposure from the product when operating it, please
familiarize yourself with following two documents “Safety and regulations” and “quick guide” of
Nordic ID products which are part of sales package. In case you have any guestions after training,
please ask from your sales contact and / or send questions to support@nordicid.com.
SAFETY AND REGULATIONS
This document include important information related to separation distance (when operate device)
between EXA51 / EXA51e and medical devices such as pacemakers, hearing aids and / or cardioverterdefibrillators.
QUICK GUIDE
This document includes important information related to RF exposure:
In page 11 pictures illustrate correct / incorrect grip. Use only correct grip. Incorrect grip may
lead to weak RFID Tag reading performance and also unnecessary RF exposure for user limb
(Hand). Keep breaks in reading if possible, breaks will decrease RF exposure.
In page 13 pictures illustrate correct / incorrect ergonomics. Correct ergonomics will mean
easier operation and avoid unnecessary RF exposure as separation distance between device
and user keeps always in safe distance. When operating device, user must be sure that there
are no any person(s) between / close by device and object.
Picture in below illustrates correct grip / how to hold EXA51 / EXA51e correctly and safely
when operate it. When hold device as shown in below, separation distance from Bluetooth
antenna to user limb / hand is approximitely 55mm and RFID antenna to user limb / hand is
75mm. In training, trainers will point locations of antennas in device.
User must always maintain minimum 2cm distance between user / or bystander(s) and
EXA51e antenna.
Document: 3
3/4
2018-01-09
EXA51 / EXA51e RF safety training
Document: 3
4/4
Download: NUR21W UHF RFID Radio Module NUR2-1W User Manual  Nordic ID Oy
Mirror Download [FCC.gov]NUR21W UHF RFID Radio Module NUR2-1W User Manual  Nordic ID Oy
Document ID3711769
Application IDxxgSXZM9SAMQxG9Vx8yuYA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize9.56kB (119550 bits)
Date Submitted2018-01-12 00:00:00
Date Available2018-01-12 00:00:00
Creation Date2018-01-09 12:52:42
Producing SoftwareFoxit Reader PDF Printer Version 7.3.4.0308
Document Lastmod2018-01-09 12:52:42
Document TitleUser Manual

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 4
Author                          : 
Create Date                     : 2018:01:09 12:52:42+02:00
Creator                         : 
Modify Date                     : 2018:01:09 12:52:42+02:00
Producer                        : Foxit Reader PDF Printer Version 7.3.4.0308
Subject                         : 
Title                           :