Q34-251366CU Provider-Specific Consumer Signal Booster Test Report Nextivity Incorporated

Nextivity Incorporated Provider-Specific Consumer Signal Booster

FCC ID Filing: YETQ34-251366CU
Purchase on Amazon: Provider-Specific Consumer Signal Booster

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 2 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 3 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 4 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 5 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 6 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 7 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 8 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 9 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 10 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 11 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 12 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 13 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 14 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 15 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 16 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 17 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 18 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 19 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 20 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 21 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 22 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 23 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 24 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 25 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 26 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 27 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 28 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 29 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 30 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 31 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 32 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 33 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 34 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 35 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 36 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 37 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 38 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 39 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 40 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 41 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 42 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Page 43 of Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated

America
Report On
EMC Evaluation of
Nextivity Inc.
Cel-Fi Quatra Cellphone Signal Repeater
FCC Part 15 Subpart B
ICES-003 Issue 5
Report No. SD72121022-1016C
January 2017
TÜV SÜD America Inc., 10040 Mesa Rim Road, San Diego, CA 92121
Tel: (858) 678-1400. Website: www.TUVamerica.com
REPORT ON
EMC Evaluation of the
Nextivity Inc.
Cel-Fi Quatra Cellphone Signal Repeater
TEST REPORT NUMBER
SD72121022-1016C
TEST REPORT DATE
January 2017
PREPARED FOR
Nextivity Inc.
16550 West Bernardo Drive, Bldg 5, Suite 550,
San Diego, CA 92127, USA
CONTACT PERSON
CK Li
Sr. Principal Engineer, Regulatory
CLi@NextivityInc.com
(858) 485-9442
PREPARED BY
Xiaoying Zhang
Name
Authorized Signatory
Title: EMC/Wireless Test Engineer
APPROVED BY
DATED
Juan M. Gonzalez
Name
Authorized Signatory
Title: Commercial Wireless EMC Lab Manager
January 03, 2017
Page 1 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
TÜV SÜD America Inc., 10040 Mesa Rim Road, San Diego, CA 92121
Tel: (858) 678-1400. Website: www.TUVamerica.com
Revision History
SD72121022-1016C
Nextivity Inc.
Cel-Fi Quatra Cellphone Signal Repeater
DATE
OLD REVISION
01/03/17
Initial Release
NEW REVISION
REASON
PAGES
AFFECTED
APPROVED BY
Juan M Gonzalez
Page 2 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Report No. SD72121022-1016C
CONTENTS
Section
Page No
REPORT SUMMARY............................................................................................................................... 4
1.1
Introduction ................................................................................................................................................ 5
1.2
Brief Summary Of Results ........................................................................................................................... 6
1.3
Product Information ................................................................................................................................... 7
1.4
EUT Test Configuration ............................................................................................................................... 9
1.5
Deviations From The Standard ................................................................................................................. 11
1.6
Modification Record ................................................................................................................................. 11
1.7
Test Methodology..................................................................................................................................... 11
1.8
Test Facility Location................................................................................................................................. 11
1.9
Test Facility Registration........................................................................................................................... 11
TEST DETAILS ...................................................................................................................................... 13
2.1
Conducted Limits ...................................................................................................................................... 14
2.2
Radiated Emission Limits .......................................................................................................................... 20
TEST EQUIPMENT USED ...................................................................................................................... 34
3.1
Test Equipment Used................................................................................................................................ 35
3.2
Measurement Uncertainty ....................................................................................................................... 36
DIAGRAM OF TEST SETUP ................................................................................................................... 37
4.1
Test Setup Diagram................................................................................................................................... 38
ACCREDITATION, DISCLAIMERS AND COPYRIGHT ............................................................................... 41
5.1
Accreditation, Disclaimers and Copyright................................................................................................. 42
Page 3 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Report No. SD72121022-1016C
SECTION 1
1REPORT SUMMARY
EMC Evaluation of the
Nextivity Inc.
Cellphone Signal Repeater
Page 4 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Report No. SD72121022-1016C
1.1
INTRODUCTION
The information contained in this report is intended to show verification of the Nextivity Inc. Cel-Fi
Quatra Cellphone Signal Repeater to the requirements of FCC Part 15 Subpart B and Innovation, Science
and Economic Development Canada ICES-003.
Objective
To perform EMC Evaluation to determine the Equipment Under
Test's (EUT’s) compliance with the Test Specification, for the
series of tests carried out.
Manufacturer
Nextivity Inc.
Model Name
Cel-Fi Quatra
Model Number(s)
NU: Q34-2/5/13/66NU
CU: Q34-2/5/13/66CU
FCC ID Number
NU: YETQ34-251366NU
CU: YETQ34-251366CU
IC Number
NU: 9298A-Q34251366NU
CU: 9298A-Q34251366CU
Serial Number(s)
258602000045 (NU), 259551000476 (CU #1), 259551000285 (CU
#2), 259551000049 (CU #3), 259551000131 (CU #4)
Number of Samples Tested
Highest Frequency Generated or
Used
2480 MHz (BT LE)
Test Specification/Issue/Date
•
•
Start of Test
March 01, 2016
Finish of Test
March 02, 2016
Name of Engineer(s)
Ferdie Custodio
Related Document(s)
None
FCC Part 15 Subpart B (October 1, 2016)
Spectrum
Management
and
Telecommunications
Interference-Causing
Equipment
Standard
ICES-003
Information Technology Equipment (ITE) — Limits and
methods of measurement (Issue 6 January 2016).
Page 5 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
BRIEF SUMMARY OF RESULTS
1.2
A brief summary of the tests carried out in accordance with FCC Part 15 Subpart B with cross-reference to
Innovation, Science and Economic Development Canada Interference-Causing Equipment Standard ICES-003 is
shown below.
Part 15
ICES-003
Test Description
Result
Comments/Base Standard
§15.107
Clause 6.1
Conducted Limits
Compliant*
Class B requirement
§15.109
Clause 6.2
Radiated Emission Limits
Compliant*
Class B requirement
Compliant*
A variant of the EUT was previously approved under FCC IDs YETQ34-251266NU and YETQ34-251266CU under
Model Numbers Q34-2/5/12/66NU and Q34-2/5/12/66CU. The EUT is identical with this model with the
exception of LTE Band 12 support. The testing were from this variant and covered under test report
SD72113545-0216A Nextivity QuatraFCC Subpart B Class B and ICES 003 Test Report.
Page 6 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
1.3
PRODUCT INFORMATION
1.3.1
Technical Description
The Equipment Under Test (EUT) was a Nextivity Inc. Cel-Fi Quatra. The EUT is a WCDMA/LTE Signal
Booster to improve voice and data cellular performance in large enterprise environments. The EUT
consists of two separate units: the Network Unit (NU) and the Coverage Unit (CU). The NU comprises a
transmitter and receiver which communicate with the cell tower and the CU. Users place the NU in an
area with the strongest signal from the carrier network. The CU is then placed in the center of the home
or office, or in the area where the best signal quality is best needed. The NU and CU are placed at
varying distances apart and are communicated via Ethernet cables. This report covers “unintentional
radiator” aspect of the EUT, all radios were placed on standby mode during testing (except for BT LE
running in very low duty cycle).
Page 7 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
1.3.2
Labelling Requirement for Innovation, Science and Economic Development Canada
The manufacturer, importer or supplier shall meet the labelling requirements set out in this section and
in Notice 2014-DRS1003 for electronic labelling for every unit:
(i) Prior to marketing in Canada, for ITE manufactured in Canada, and;
(ii) Prior to importation into Canada, for imported ITE.
Each unit of an ITE model shall bear a label (see below) that represents the manufacturer’s or the
importer’s SDoC with Innovation, Science and Economic Development Canada’s ICES-003. This label
shall be permanently affixed to the ITE or displayed electronically and its text must be clearly legible. If
the dimensions of the device are too small or if it is not practical to place the label on the ITE and
electronic labelling has not been implemented, the label shall be, upon agreement with Innovation,
Science and Economic Development Canada, placed in a prominent location in the user manual
supplied with the ITE. The user manual may be in an electronic format and must be readily available.
Innovation, Science and Economic Development Canada ICES-003 Compliance Label:
CAN ICES-3 (B)/NMB-3(B)
1.3.3
Labelling Requirement for Part 15 (Verification) Device
See FCC Publication Number: 784748 for details:
https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?id=27980&switch=P
Page 8 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
1.4
EUT TEST CONFIGURATION
1.4.1
Test Configuration Description
1.4.2
Test Configuration
Description
Default
NU powered supplying power via PoE to CU. Both NU and the CUs were fully
booted up before each test. For Radiated Emissions, the NU and CU were
verified independently while maintaining connections with each other. For AC
Conducted Emissions, the EUT were tested as a set where four (4) CUs were
connected to the NU.
EUT Exercise Software
None. No special test software was used to exercise the EUT during verification.
1.4.3
Support Equipment and I/O cables
Manufacturer
Equipment/Cable
Description
Phihong
Switching Power Supply
Model PSA120U-540L6NT-R Rev 02 No. 026
(Engineering Sample)
Netgear
ProSAFE® 8-Port Gigabit Switch
M/N GS108v4 S/N 3TX25B7W86385
Netgear
AC-DC Adapter for support switch
Model AD2015F23 P/N 332-10744-01
Network patch Cable (2x NU to
support Switch)
4.0m, unshielded, Cat5e 24AWG UTP
Network patch Cable (4x NU to CU)
4.0m, unshielded, Cat5e 24AWG UTP
Coaxial Cable (2x NU/CU to support
antenna)
7.0m, RG-142 B/U
Taoglass
2G/3G/4G Terminal Antenna (2x)
Model TG.10.0113
Page 9 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
1.4.4
Simplified Test Configuration Diagram
Page 10 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
1.5
DEVIATIONS FROM THE STANDARD
No deviations from the applicable test standards or test plan were made during testing.
1.6
MODIFICATION RECORD
Description of Modification
Modification
Fitted By
Date
Modification
Fitted
Serial Number: 258602000045 (NU), 259551000476 (CU #1), 259551000285 (CU #2), 259551000049 (CU #3), 259551000131 (CU
#4)
N/A
The table above details modifications made to the EUT during the test programme. The modifications
incorporated during each test (if relevant) are recorded on the appropriate test pages.
1.7
TEST METHODOLOGY
All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.
For radiated emissions the equipment under test (EUT) was configured to measure its highest possible
emission level. This level was based on the maximized cable configuration from exploratory testing per
ANSI C63.4-2014. The test modes were adapted according to the Operating Instructions provided by the
manufacturer/client.
1.8
TEST FACILITY LOCATION
1.8.1
TÜV SÜD America Inc. (Mira Mesa)
10040 Mesa Rim Road, San Diego, CA 92121-2912 (32.901268,-117.177681). Phone: 858 678 1400 Fax:
858 546 0364.
1.8.2
TÜV SÜD America Inc. (Rancho Bernardo)
16936 Via Del Campo, San Diego, CA 92127-1708 (33.018644,-117.092409). Phone: 858 678-1400 Fax:
858 546 0364.
1.9
TEST FACILITY REGISTRATION
1.9.1
FCC – Registration No.: US1146
TUV SUD America Inc. (San Diego), is an accredited test facility with the site description report on file
and has met all the requirements specified in §2.948 of the FCC rules. The acceptance letter from the
FCC is maintained in our files and the Registration is US1146.
Page 11 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
1.9.2
Innovation, Science and Economic Development Canada (IC) Registration No.: 3067A
The 10m Semi-anechoic chamber of TUV SUD America Inc. (San Diego) has been registered by
Certification and Engineering Bureau of Innovation, Science and Economic Development Canada for
radio equipment testing with Registration No. 3067A.
1.9.3
BSMI – Laboratory Code: SL2-IN-E-028R (US0102)
TUV Product Service Inc. (San Diego) is a recognized EMC testing laboratory by the BSMI under the MRA
(Mutual Recognition Arrangement) with the United States. Accreditation includes CNS 13438 up to
6GHz.
1.9.4
VCCI – Registration No. A-0230
TUV SUD America Inc. (San Diego) is a VCCI registered measurement facility which includes radiated field
strength measurement, radiated field strength measurement above 1GHz, mains port interference
measurement and telecommunication port interference measurement.
Page 12 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
SECTION 2
2TEST DETAILS
EMC Evaluation of the
Nextivity Inc.
Cellphone Signal Repeater
Page 13 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.1
CONDUCTED LIMITS
2.1.1
Specification Reference
Part 15 Subpart B §15.107(a)
2.1.2
Standard Applicable
Except for Class A digital devices, for equipment that is designed to be connected to the public utility
(AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following
table, as measured using a 50 μH/50 ohms line impedance stabilization network (LISN). Compliance with
the provisions of this paragraph shall be based on the measurement of the radio frequency voltage
between each power line and ground at the power terminal. The lower limit applies at the band edges
Frequency of emission (MHz)
Conducted limit (dBμV)
Quasi-peak
Average
0.15–0.5
66 to 56*
56 to 46*
0.5–5
56
46
5–30
60
50
*Decreases with the logarithm of the frequency.
2.1.3
Equipment Under Test and Modification State
Serial No: 258602000045 (NU), 259551000476 (CU #1), 259551000285 (CU #2), 259551000049 (CU #3),
259551000131 (CU #4) /Default Test Configuration
2.1.4
Date of Test/Initial of test personnel who performed the test
March 01, 2016/FSC
2.1.5
Test Equipment Used
The major items of test equipment used for the above tests are identified in Section 3.1.
2.1.6
Environmental Conditions
Test performed at TÜV SÜD America Inc. Rancho Bernardo facility.
Ambient Temperature
Relative Humidity
ATM Pressure
2.1.7
24.9 °C
42.3 %
99.3 kPa
Additional Observations
•
EUT verified as a system through the NU with four (4) CU connected.
Page 14 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
•
2.1.8
Measurement was done using EMC32 V8.53 automated software. Reported level is the actual
level with all the correction factors factored in. Correction Factor column is for informational
purposes only. See Section 2.1.8 for sample computation.
Sample Computation (Conducted Emission – Quasi Peak)
Measuring equipment raw measurement (dbµV) @ 150kHz
Asset# 8822(20 dB attenuator)
Asset# 1177 (cable)
Correction Factor (dB)
Asset# 1176 (cable)
Asset# 7567(LISN)
Reported QuasiPeak Final Measurement (dbµV) @ 150kHz
2.1.9
5.5
19.9
0.15
0.35
0.30
20.7
26.2
Test Results
Compliant. See attached plots and tables.
Page 15 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.1.10
FCC Class B 120V 60Hz (Line 1 – Hot)
TUV SR7 Line 1
80
70
FCC Part 15 Class B Voltage on Mains QP
Level in dBµV
60
FCC Part 15 Class B Voltage on Mains AV
50
40
30
20
10
150k
300 400 500
800 1M
2M
3M
4M 5M 6
8 10M
20M
30M
Frequency in Hz
FCC Part 15 Class B Voltage on Mains QP [..\EMI conducted\]
FCC Part 15 Class B Voltage on Mains AV [..\EMI conducted\]
Preview Result 1-PK+ [Preview Result 1.Result:1]
Preview Result 2-AVG [Preview Result 2.Result:2]
Final Result 1-QPK [Final Result 1.Result:1]
Final Result 2-AVG [Final Result 2.Result:1]
Quasi Peak
Frequency
(MHz)
QuasiPeak
(dBµV)
Meas. Time
(ms)
Bandwidth
(kHz)
Filter
Line
Corr.
(dB)
0.154500
0.420000
1.248000
2.868000
5.338500
24.216000
45.4
38.0
34.4
38.2
34.2
31.1
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
9.000
9.000
9.000
9.000
9.000
9.000
Off
Off
Off
Off
Off
Off
L1
L1
L1
L1
L1
L1
20.2
20.0
20.0
20.1
20.1
20.5
Frequency
(MHz)
Average
(dBµV)
Meas. Time
(ms)
Bandwidth
(kHz)
Filter
Line
Corr.
(dB)
0.352500
0.478500
1.122000
3.156000
5.208000
16.228500
36.7
34.7
26.2
29.9
25.9
26.6
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
9.000
9.000
9.000
9.000
9.000
9.000
Off
Off
Off
Off
Off
Off
L1
L1
L1
L1
L1
L1
20.0
20.0
20.0
20.1
20.1
20.3
Margin QPK
(dB)
20.3
19.4
21.6
17.8
25.8
28.9
Limit QPK
(dBµV)
65.7
57.3
56.0
56.0
60.0
60.0
Average
Margin Ave
(dB)
12.0
11.6
19.8
16.1
24.1
23.4
Limit - Ave
(dBµV)
48.7
46.3
46.0
46.0
50.0
50.0
Page 16 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.1.11
FCC Class B 120V 60Hz (Line 2 – Neutral)
TUV SR7 Line 2
80
70
FCC Part 15 Class B Voltage on Mains QP
Level in dBµV
60
FCC Part 15 Class B Voltage on Mains AV
50
40
30
20
10
150k
300 400 500
800 1M
2M
3M
4M 5M 6
8 10M
20M
30M
Frequency in Hz
FCC Part 15 Class B Voltage on Mains QP [..\EMI conducted\]
FCC Part 15 Class B Voltage on Mains AV [..\EMI conducted\]
Preview Result 1-PK+ [Preview Result 1.Result:1]
Preview Result 2-AVG [Preview Result 2.Result:2]
Final Result 1-QPK [Final Result 1.Result:1]
Final Result 2-AVG [Final Result 2.Result:1]
Quasi Peak
Frequency
(MHz)
QuasiPeak
(dBµV)
Meas. Time
(ms)
Bandwidth
(kHz)
Filter
Line
Corr.
(dB)
0.150000
0.483000
1.252500
2.791500
5.307000
24.450000
46.5
38.9
33.3
37.3
34.9
31.5
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
9.000
9.000
9.000
9.000
9.000
9.000
Off
Off
Off
Off
Off
Off
20.2
20.0
20.0
20.1
20.1
20.4
Frequency
(MHz)
Average
(dBµV)
Meas. Time
(ms)
Bandwidth
(kHz)
Filter
Line
Corr.
(dB)
0.352500
0.352500
1.018500
2.733000
5.316000
24.445500
36.3
36.4
26.0
28.8
24.3
26.9
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
9.000
9.000
9.000
9.000
9.000
9.000
Off
Off
Off
Off
Off
Off
20.0
20.0
20.0
20.1
20.1
20.4
Margin QPK
(dB)
19.5
17.4
22.7
18.7
25.1
28.5
Limit QPK
(dBµV)
66.0
56.3
56.0
56.0
60.0
60.0
Average
Margin Ave
(dB)
12.4
12.3
20.0
17.2
25.7
23.1
Limit - Ave
(dBµV)
48.7
48.7
46.0
46.0
50.0
50.0
Page 17 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.1.12
Test Setup Photo (Front)
Arrangement of EUT is for maximum separation possible as recommended by the manufacturer
Page 18 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.1.13
Test Setup Photo (Back)
Arrangement of EUT is for maximum separation possible as recommended by the manufacturer
Page 19 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2
RADIATED EMISSION LIMITS
2.2.1
Specification Reference
Part 15 Subpart B §15.109(a)
2.2.2
Standard Applicable
(a) Except for Class A digital devices, the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:
2.2.3
Frequency of emission (MHz)
Field Strength (microvolts/meter)
30-88
100
88-216
150
216-960
200
Above 960
500
Equipment Under Test and Modification State
Serial No: 258602000045 (NU), 259551000476 (CU #1), 259551000285 (CU #2), 259551000049 (CU #3),
259551000131 (CU #4) /Default Test Configuration
2.2.4
Date of Test/Initial of test personnel who performed the test
March 02, 2016/FSC
2.2.5
Test Equipment Used
The major items of test equipment used for the above tests are identified in Section 3.1.
2.2.6
Environmental Conditions
Test performed at TÜV SÜD America Inc. Rancho Bernardo facility.
Ambient Temperature
Relative Humidity
ATM Pressure
2.2.7
25.7 °C
41.3 %
99.5 kPa
Additional Observations
•
•
•
The spectrum was searched from 30MHz to 18GHz.
Verification was performed at 3 meters.
Measurement was done using EMC32 V8.53 automated software. Reported level is the actual
level with all the correction factors factored in. Correction Factor column is for informational
purposes only. See Section 2.2.8 for sample computation.
Page 20 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.8
Sample Computation (Radiated Emission)
Measuring equipment raw measurement (dbµV) @ 30 MHz
Asset# 1066 (cable)
Asset# 1172 (cable)
Correction Factor (dB)
Asset# 1016 (preamplifier)
Asset# 1175(cable)
Asset# 1033 (antenna)
Reported QuasiPeak Final Measurement (dbµV/m) @ 30MHz
2.2.9
24.4
0.3
0.3
-30.7
0.3
17.2
-12.6
11.8
Test Results
See attached plots.
Page 21 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.9.1
Below 1GHz Radiated Emission Test (NU)
Continuous Rotation TUV 3m Radiated 30 to 1000MHz
80
70
60
Level in dBµV/m
FCC Part 15 Class B Electric Field Strength QP
50
40
30
20
10
30M
50
60
80
100M
200
300
400
500
800
1G
Frequency in Hz
Quasi-Peak Data
Frequency
(MHz)
QuasiPeak
(dBµV/m)
36.471663
43.687214
70.621643
99.003848
169.016032
491.525291
28.9
28.6
31.8
30.6
34.0
41.2
Meas.
Time
(ms)
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
Bandwidth
(kHz)
Height
(cm)
Polarization
Azimuth
(deg)
Corr.
(dB)
Margin
(dB)
Limit
(dBµV/m)
120.000
120.000
120.000
120.000
120.000
120.000
100.0
100.0
377.0
127.0
100.0
100.0
279.0
285.0
311.0
41.0
184.0
223.0
-9.2
-12.3
-16.8
-14.1
-12.8
-1.6
11.1
11.4
8.2
12.9
9.5
4.8
40.0
40.0
40.0
43.5
43.5
46.0
Test Notes: All four (4) CU were placed inside a Faraday cage.
Page 22 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Above 1GHz Radiated Emission Test (NU)
2.2.9.2
Continuous Rotation TUV 3m Radiated 1000 to 18000MHz
90
80
FCC Part 15 Class B Electric Field Strength PK above 1GHz
70
Level in dBµV/m
60
FCC Part 15 Class B Electric Field Strength AV above 1GHz
50
40
30
20
10
1G
2G
3G
4G
5G
10G
18G
Frequency in Hz
Peak Data
Frequency
(MHz)
MaxPeak
(dBµV/m)
1000.400000
1932.366667
4181.066667
4634.966667
11088.733333
16249.600000
44.0
50.4
40.1
42.2
46.7
50.2
Meas.
Time
(ms)
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
Bandwidth
(kHz)
Height
(cm)
Polarization
Azimuth
(deg)
Corr.
(dB)
Margin
(dB)
Limit
(dBµV/m)
1000.000
1000.000
1000.000
1000.000
1000.000
1000.000
239.4
270.3
404.5
372.1
404.5
238.4
11.0
245.0
175.0
-20.0
87.0
20.0
-7.9
-1.6
1.9
2.8
11.6
17.1
29.9
23.5
33.8
31.7
27.2
23.7
73.9
73.9
73.9
73.9
73.9
73.9
Bandwidth
(kHz)
Height
(cm)
Polarization
Azimuth
(deg)
Corr.
(dB)
Margin
(dB)
Limit
(dBµV/m)
1000.000
1000.000
1000.000
1000.000
1000.000
1000.000
239.4
270.3
404.5
372.1
404.5
238.4
11.0
245.0
175.0
-20.0
87.0
20.0
-7.9
-1.6
1.9
2.8
11.6
17.1
23.6
19.9
26.1
24.8
20.4
16.5
53.9
53.9
53.9
53.9
53.9
53.9
Average Data
Frequency
(MHz)
Average
(dBµV/m)
1000.400000
1932.366667
4181.066667
4634.966667
11088.733333
16249.600000
30.3
34.0
27.8
29.1
33.5
37.4
Meas.
Time
(ms)
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
Test Notes: BT LE ignored during final measurement phase.
Page 23 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.9.3
Below 1GHz Radiated Emission Test (CU)
Continuous Rotation TUV 3m Radiated 30 to 1000MHz
80
70
60
Level in dBµV/m
FCC Part 15 Class B Electric Field Strength QP
50
40
30
20
10
30M
50
60
80
100M
200
300
400
500
800
1G
Frequency in Hz
Quasi-Peak Data
Frequency
(MHz)
QuasiPeak
(dBµV/m)
30.120000
70.781643
85.692745
491.525291
698.977395
908.877275
26.3
26.0
27.2
44.5
26.8
29.3
Meas.
Time
(ms)
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
Bandwidth
(kHz)
Height
(cm)
Polarization
Azimuth
(deg)
Corr.
(dB)
Margin
(dB)
Limit
(dBµV/m)
120.000
120.000
120.000
120.000
120.000
120.000
150.0
100.0
100.0
100.0
211.0
150.0
18.0
-5.0
326.0
250.0
208.0
154.0
-5.6
-16.8
-15.9
-1.6
3.1
6.4
13.7
14.0
12.8
1.5
19.2
16.7
40.0
40.0
40.0
46.0
46.0
46.0
Test Notes: NU was placed inside a Faraday cage for this test.
Page 24 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Above 1GHz Radiated Emission Test (CU)
2.2.9.4
Continuous Rotation TUV 3m Radiated 1000 to 18000MHz
90
80
FCC Part 15 Class B Electric Field Strength PK above 1GHz
70
Level in dBµV/m
60
FCC Part 15 Class B Electric Field Strength AV above 1GHz
50
40
30
20
10
1G
2G
3G
4G
5G
10G
18G
Frequency in Hz
Peak Data
Frequency
(MHz)
MaxPeak
(dBµV/m)
1000.000000
1993.200000
3729.633333
5407.533333
10654.666667
17475.866667
43.2
44.4
40.7
42.0
45.9
51.2
Meas.
Time
(ms)
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
Bandwidth
(kHz)
Height
(cm)
Polarization
Azimuth
(deg)
Corr.
(dB)
Margin
(dB)
Limit
(dBµV/m)
1000.000
1000.000
1000.000
1000.000
1000.000
1000.000
202.3
314.2
167.6
164.6
300.6
302.2
287.0
320.0
13.0
245.0
20.0
20.0
-7.9
-0.7
1.2
3.9
11.1
18.0
30.7
29.5
33.2
31.9
28.0
22.7
73.9
73.9
73.9
73.9
73.9
73.9
Bandwidth
(kHz)
Height
(cm)
Polarization
Azimuth
(deg)
Corr.
(dB)
Margin
(dB)
Limit
(dBµV/m)
1000.000
1000.000
1000.000
1000.000
1000.000
1000.000
202.3
314.2
167.6
164.6
300.6
302.2
287.0
320.0
13.0
245.0
20.0
20.0
-7.9
-0.7
1.2
3.9
11.1
18.0
23.2
25.1
25.8
24.9
20.6
15.4
53.9
53.9
53.9
53.9
53.9
53.9
Average Data
Frequency
(MHz)
Average
(dBµV/m)
1000.000000
1993.200000
3729.633333
5407.533333
10654.666667
17475.866667
30.7
28.8
28.1
29.0
33.3
38.5
Meas.
Time
(ms)
1000.0
1000.0
1000.0
1000.0
1000.0
1000.0
Test Notes: BT LE and known ambient noise were ignored during final measurement phase.
Page 25 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.10
Test Setup Photo (Below 1GHz Front -NU)
Page 26 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.11
Test Setup Photo (Below 1GHz Back -NU)
Page 27 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.12
Test Setup Photo (Above 1GHz Front - NU)
Page 28 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.13
Test Setup Photo (Above 1GHz Back - NU)
Page 29 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.1
Test Setup Photo (Below 1GHz Front -CU)
Page 30 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.2
Test Setup Photo (Below 1GHz Back -CU)
Page 31 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.3
Test Setup Photo (Above 1GHz Front - CU)
Page 32 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
2.2.4
Test Setup Photo (Above 1GHz Back - CU)
Page 33 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
SECTION 3
3TEST EQUIPMENT USED
Page 34 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
3.1
TEST EQUIPMENT USED
List of absolute measuring and other principal items of test equipment.
ID Number
(SDGE/SDRB)
Test Equipment
Type
Serial Number
Manufacturer
Cal Date
Cal Due Date
Conducted Emissions
7620
EMI Test Receiver
ESU40
100399
Rhode & Schwarz
09/03/15
09/03/16
7567
LISN
FCC-LISN-50-25-210
120304
Fischer Custom
Comm.
07/14/15
07/14/16
7568
LISN
FCC-LISN-50-25-210
120305
Fischer Custom
Comm.
10/28/15
10/28/16
8822
20dB Attenuator
34-20-34
N/A
MCE / Weinschel
02/29/16
02/28/17
8824
20dB Attenuator
34-20-34
N/A
MCE / Weinschel
02/29/16
02/28/17
Radiated Emissions
1002
Bilog Antenna
3142C
00058717
ETS-Lindgren
11/06/15
11/06/17
1040
EMI Test Receiver
ESIB40
100292
Rhode & Schwarz
09/29/15
09/29/16
1016
Pre-amplifier
PAM-0202
187
PAM
12/15/15
12/15/16
7575
Double-ridged waveguide
horn antenna
3117
00155511
EMCO
04/27/15
04/27/16
1049
EMI Test Receiver
ESU
100133
Rhode & Schwarz
03/11/15
03/11/16
8628
Pre-amplifier
QLJ 01182835-JO
8986002
QuinStar
Technologies Inc.
03/20/15
03/20/16
6792
Multimeter
3478A
2911A70964
Hewlett Packard
08/14/15
08/14/16
7560
Barometer/Temperature
/Humidity Transmitter
iBTHX-W
1240476
Omega
10/19/15
10/19/16
Test Software
EMC32
V8.53
Rhode & Schwarz
Miscellaneous
N/A
Page 35 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
MEASUREMENT UNCERTAINTY
3.2
For a 95% confidence level, the measurement uncertainties for defined systems are:
3.2.1
Conducted Measurements
Contribution
Probability
Distribution
Type
Probability
Distribution
xi
Standard
Uncertainty
u(xi)
[u(xi)]2
Receiver/Spectrum Analyzer
Rectangular
0.36
0.21
0.04
Cables
Rectangular
0.50
0.29
0.08
LISN
Rectangular
0.66
0.38
0.15
Attenuator
Rectangular
0.30
0.17
0.03
EUT Setup
Rectangular
1.00
0.58
0.33
Combined Uncertainty (uc):
0.80
Coverage Factor (k):
Expanded Uncertainty:
1.59
3.2.2
Radiated Measurements (Below 1GHz)
Contribution
Receiver/Spectrum Analyzer
Cables
Probability
Distribution
Type
Probability
Distribution
xi
Standard
Uncertainty
u(xi)
[u(xi)]2
Rectangular
0.45
0.26
0.07
Rectangular
0.50
0.29
0.08
0.29
0.08
Preamp
Rectangular
0.50
Antenna
Rectangular
0.75
0.43
0.19
Site
Rectangular
2.70
1.56
2.43
EUT Setup
Rectangular
1.00
0.58
0.33
Combined Uncertainty (uc):
1.78
Coverage Factor (k):
Expanded Uncertainty:
3.57
Standard
Uncertainty
u(xi)
0.33
[u(xi)]2
0.11
3.2.3
Radiated Emission Measurements (Above 1GHz)
Probability
Distribution
Type
Receiver/Spectrum Analyzer
Rectangular
Probability
Distribution xi
0.57
Cables
Rectangular
0.70
0.40
0.16
Preamp
Rectangular
0.50
0.29
0.08
Antenna
Rectangular
0.37
0.21
0.05
Site
Rectangular
2.70
1.56
2.43
EUT Setup
Rectangular
1.00
0.58
0.33
Combined Uncertainty (uc):
1.78
Contribution
Coverage Factor (k):
Expanded Uncertainty:
3.56
Page 36 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
SECTION 4
4DIAGRAM OF TEST SETUP
Page 37 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
4.1
TEST SETUP DIAGRAM
Radiated Emission Test Setup (Below 1GHz)
Page 38 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Radiated Emission Test Setup (Above 1GHz)
Page 39 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Conducted Emission Test Setup
Page 40 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
SECTION 5
5ACCREDITATION, DISCLAIMERS AND COPYRIGHT
Page 41 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
5.1
ACCREDITATION, DISCLAIMERS AND COPYRIGHT
TÜV SÜD America Inc.’s reports apply only to the specific sample tested under stated test
conditions. It is the manufacturer’s responsibility to assure the continued compliance of
production units of this model. TÜV SÜD America, Inc. shall have no liability for any deductions,
inferences or generalizations drawn by the client or others from TÜV SÜD America, Inc.’s issued
reports.
This report is the confidential property of the client. As a mutual protection to our clients, the
public and TÜV SÜD America, Inc., extracts from the test report shall not be reproduced, except
in full without TÜV SÜD America, Inc.’s written approval.
This report must not be used to claim product certification, approval, or endorsement by
A2LA, NIST, or any agency of the federal government.
TÜV SÜD America, Inc. and its professional staff hold government
and professional organization certifications for
AAMI, ACIL, AEA, ANSI, IEEE, A2LA, NIST and VCCI.
A2LA Cert. No. 2955.13
Page 42 of 42
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400
FAX: 858 546 0364
Download: Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Mirror Download [FCC.gov]Q34-251366CU Provider-Specific Consumer Signal Booster Test Report  Nextivity Incorporated
Document ID3246988
Application IDe6ZvyxpNDA+hgjvpa/xmgw==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize165.42kB (2067793 bits)
Date Submitted2017-01-04 00:00:00
Date Available2017-01-06 00:00:00
Creation Date2017-01-03 13:59:52
Producing SoftwareNuance PDF Create
Document Lastmod2017-01-03 14:01:00
Document TitleTest Report
Document CreatorMicrosoft Word - SD72121022-1016C Nextivity FCC Subpart B Class B and ICES 003 Test Report
Document Author: gonza-ju

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Fill forms, Extract, Assemble, Print high-res
Page Count                      : 43
Page Mode                       : UseNone
XMP Toolkit                     : 3.1-701
Producer                        : Nuance PDF Create
Creator Tool                    : Microsoft Word - SD72121022-1016C Nextivity FCC Subpart B Class B and ICES 003 Test Report
Create Date                     : 2017:01:03 13:59:52-08:00
Modify Date                     : 2017:01:03 14:01:00-08:00
Title                           : Microsoft Word - SD72121022-1016C Nextivity FCC Subpart B Class B and ICES 003 Test Report
Creator                         : gonza-ju
Author                          : gonza-ju
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2018