H3EM62 Electronic Swing handle User Manual General open questions: Southco,. Inc

Southco,. Inc Electronic Swing handle

Page 1 of H3EM62 Electronic Swing handle User Manual General open questions: Southco,. Inc
Page 2 of H3EM62 Electronic Swing handle User Manual General open questions: Southco,. Inc
Page 3 of H3EM62 Electronic Swing handle User Manual General open questions: Southco,. Inc
Page 4 of H3EM62 Electronic Swing handle User Manual General open questions: Southco,. Inc

H3-EM-62-100 Electronic Swinghandle
Operating Instructions
Package Contents








H3-EM-62-100 Electronic Swinghandle
with RFID Reader (qty1)
EM-0-45827 M3x25 POZIDRIV® Mounting Screws (qty 4)
EM-0-47151 M3x14 POZIDRIV® Mounting Screw (qty 1)
H3-EM-0-61927 Rotation Limiter (qty 1)
E5-C-04 Pawl Screw (qty 1)
EM-0-45826 Top Mounting Bracket (qty 1)
EM-0-45822 Bottom Mounting Bracket (qty 1)
Operating Instructions (qty 1)
H3-EM-62-100 Electronic Swinghandle with RFID Reader
Specifications
Actuator Module
Supply Voltage (VSUPPLY): 12VDC to 24VDC (NOTE: Status LED will blink
red if the supply voltage is out of range.)
Standby Current:
50mA maximum at 12VDC
Operating Current:
200mA maximum at 12VDC (with no external
mechanical load applied to handle
Stall Current:
1A maximum (at 12VDC, limited to 2 seconds)
Operating Transit Time: 1 second maximum (NOTE: Power must be
present during transit times. If power is
removed while the lock slide is in transit, it will
complete it’s cycle when power is
restored.)
Electronic Unlock Time: 3 seconds minimum
Open Collector Outputs: Rated for VSUPPLY, maximum load
RFID Reader Module
Supply Voltage (VCC):
Operating Current:
12VDC to 24VDC
125mA maximum (no external devices
attached)
Transmit Frequency:
13.56MHz / 125kHz
DATA Signal Voltage:
5VDC
DATA Pulse Interval Time: 40µs
DATA Signal Delay:
2ms
Output Format:
Reverse Byte Order (13.56MHz cards)
Most Significant Bit First (125kHz cards)
Upper and Lower Parity Bits Included
Mounting and Installation
Please refer to Southco trade drawing J-H3-EM-62-100 for mounting and
installation details.
NOTE: Use a #1 POZIDRIV® driver when installing the mounting
screws. See Southco trade drawing J-H3-EM-62-100 for additional details.
1.
2.
3.
4.
Handle
RFID Reader
Tri-Color Status LED
Lock Plug
Read range distance may vary depending on card type, mounting
conditions, or environmental conditions. In some cases, the card
may need to make contact with, or be moved across, the RFID reader.
Wiring Diagrams
Features









Installed 13.56MHz / 125kHz RFID reader module with Wiegand
data output
Compatible with 13.56MHz RFID cards with 4, 7, or 8byte
Unique Identifiers (UID) and 125kHz prox cards
Remote lock and unlock capability
Single or multi-point lock actuation
Momentary or continuous lock actuation
Tri-color LED (blue/magenta/red) to indicate lock and handle
status
Manual lock override
Accommodates both left and right doors
For indoor use only
J-H3-EM-62-100-M
The H3-EM-62-100 contains two separate functional modules: the actuator
module and RFID reader module. The actuator module controls and
monitors the locking function of the swinghandle. The RFID module reads
the contents of a compatible RFID card and converts it to Wiegand format.
These two modules operate independently of each other and require
connection to an access control unit (not provided), as illustrated below,
for the entire product to be fully functional.
Page 1 of 4
H3-EM-62-100 Electronic Swinghandle
Operating Instructions
The actuator module of the swinghandle is accessed with a six-position
connector on the rear of the unit, shown below.
Wiegand Data Output
125kHz Prox Cards
The RFID module will read the site and user codes from a compatible prox
card, and convert to Wiegand data format, including upper even parity (Pe)
and lower odd parity (Po) bits, as shown below.
13.56MHz RFID Cards
The RFID module will read the 4, 7, or 8 byte UID from a compatible RFID
card, and convert to Wiegand data format in reverse byte order, including
upper even parity (Pe) and lower odd parity (Po) bits, as shown below.
Pin
Description
VGND
VSUPPLY
N/C
Control Signal
Electronic Lock
Status
Mechanical Lock
Status
Note
ground (must be same as RFID reader
module)
12 to 24 VDC power supply input (may be
connected to prox reader VCC input)
no connect
command input (9VDC up to supply
voltage, 100 milliseconds minimum)
open collector output (rated for VSUPPLY,
100mA max. load)
open collector output (rated for VSUPPLY,
100mA max. load)
The RFID reader module of the swinghandle is accessed with a fourposition connector attached to a harness connected to the module’s circuit
board. The module’s connector pinout is:
Control Input Signal
This signal is used to control the electronic lock slide position.


for UNLOCKED position: Supply 9VDC minimum (do not exceed
supply voltage) for at least 100 milliseconds. The lock will
remain unlocked for as long as the signal is present, or a
minimum of 3 seconds. Signal timing can typically be adjusted
at the access control device. The control signal current draw is
less than 10mA.
for LOCKED position: Supply an open contact or 0VDC (0 to
0.5V)
Electronic Lock Status Output and Mechanical Lock Status Output
Signals
Pin
Wire Color
Black
Description
GND
Red
VCC
Green
White
DATA0
DATA1
Note
ground (must be same as actuator
module)
12 to 24VDC power supply input
(may be connected to EML VSUPPLY
input)
DATA0 output
DATA1 output
NOTE: The mating connectors/harnesses are not provided with the
H3-EM-62-100. Refer to Southco trade drawing J-H3-EM-62-100 for
mating connector/harness requirements.
J-H3-EM-62-100-M
Electronic Lock Status Output Signal
This output will be LOW (GND) when the lock slide is electromechanically
moved to the unlocked position. It will be in the open collector state (highimpedance) when in the locked position.
Mechanical Lock Status Output Signal
This output will be LOW (GND) when the handle is in the open position or
when the keylock in the actuator is manually unlocked. It will be in the
open collector state (high-impedance) when in the secured position.
NOTE: These outputs are open collector outputs rated for VSUPPLY with
a maximum load of 100mA. To avoid damage to the H3-EM, do not
exceed voltage and current ratings.
Page 2 of 4
H3-EM-62-100 Electronic Swinghandle
Operating Instructions
Status LED and Output Signals
Mechanically Released
The latch is equipped with a tri-color (blue/magenta/red) LED visible from
the front of the latch. This LED provides a visible notification of the latch
status. The different latch states are described below. Please refer to the
Control Input Signal, Electronic Lock Status Output Signal, and
Mechanical Lock Status Output Signal sections for further details on
these signals.
The latch is released by opening the handle or moving the cam from its
lock position.

The Status LED will flash blue.

The electronic lock status output will be at its open collector state
if the electronic lock slide is in the locked position. It will be 0V if
the lock slide is in the unlocked position.

The mechanical lock status output is 0V.
Secured
The latch is securely closed, prohibiting access.

The Status LED will be solid blue.

The electronic lock status output is at its open collector state.

The mechanical lock status output is at its open collector state.
handle secured
in housing, cam
in locked
position
NOTE: The lock sensor is an optical device that senses the presence
of the lock pawl. Reflectivity of the lock pawl material can affect sensing.
Use only Southco-supplied locks.
electronic
lock slide in
locked
position
electronic lock
slide in locked
position
electronic
lock slide in
unlocked
position
lock plug in
unlocked
position
“Secured” State
“Mechanically Released” State
Electronically Released
Handle not Fully Closed
The electronic lock slide is in the unlocked position and the handle can be
pulled open.

The Status LED will alternate flashing blue/magenta.

The electronic lock status output is 0V while the lock slide is in
the unlocked position.

The mechanical lock status output is at its open collector state.
This is an interim state and may occur while closing the handle when the
cam is not secured by the electronic lock slide. The latch is not fully
secured during this state.

The Status LED will alternate flashing blue/red if the cam is not
detected. It will flash blue/red/red if the cam is detected, but the
lock plate is not in the right position. This could be due to
mechanical failure or tampering.

The electronic lock status output is 0V if the lock slide is in the
unlocked position. It will be at its open collector state if it is in the
lock position.

The mechanical lock status output is 0V if the cam is not
detected. It will be at its open collector state if it is detected.
electronic
lock slide in
unlocked
position
handle
secured in
housing, cam
in locked
position
cam not
detected by
latch
cam
detected by
latch
“Electronically Released” State
“Handle not Fully Closed” State
J-H3-EM-62-100-M
Page 3 of 4
H3-EM-62-100 Electronic Swinghandle
Operating Instructions
Electronic Lock Slide Error
Error Input Command Sequence
The electronic lock slide does not respond to the command input signal.

The Status LED will flash magenta if the latch is secured. It will
alternate flashing red/magenta if the latch is mechanically
released.

The electronic lock status output is at its open collector state.

The mechanical lock status output will be at its open collector
state if the cam is in its lock position. It will be 0V if the
mechanical key is moved from its lock position.
The H3-EM can accept an input command from an external controller to
flash the status LED red three times. This feature can be used to indicate
that an error event has occurred (e.g. unauthorized access attempt).
The control input signal needs to meet the timing requirements shown
below to flash the status LED red.
Tburst
control
input
Ton Toff
Ton = 5ms
Toff = 5ms
Tburst = 400ms (min)
POZIDRIV® is a registered trademark of the Phillips Screw Company
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1)
2)
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:




Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral
devices).
Industry Canada Compliance Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1)
2)
this device may not cause interference, and
this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes:
1)
2)
l’appareil ne doit pas produire de brouillage, et
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
J-H3-EM-62-100-M
Page 4 of 4
Download: H3EM62 Electronic Swing handle User Manual General open questions: Southco,. Inc
Mirror Download [FCC.gov]H3EM62 Electronic Swing handle User Manual General open questions: Southco,. Inc
Document ID4067024
Application IDTiqwh6evpDWaggnjEayYdA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize69.98kB (874753 bits)
Date Submitted2018-11-10 00:00:00
Date Available2018-11-10 00:00:00
Creation Date2018-10-24 15:52:06
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2018-10-24 15:52:06
Document TitleGeneral open questions:
Document CreatorMicrosoft® Word 2010
Document Author: BBarger@southco.com

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 4
Language                        : en-US
Tagged PDF                      : Yes
Title                           : General open questions:
Author                          : BBarger@southco.com
Creator                         : Microsoft® Word 2010
Create Date                     : 2018:10:24 15:52:06-04:00
Modify Date                     : 2018:10:24 15:52:06-04:00
Producer                        : Microsoft® Word 2010