Customizable smart band RF Exposure Info Mighty Cast, Inc

Mighty Cast, Inc Customizable smart band

See More Details For FCC ID: 2AKN3-16420NEX
Purchase on Amazon: Customizable smart band
Download: Customizable smart band RF Exposure Info Mighty Cast, Inc
Document DescriptionRF Exporure
Document TypeRF Exposure Info
Document Titleuntitled

Document

Trouble Loading? Try Customizable smart band RF Exposure Info Mighty Cast, Inc Downloading this document. Zoom In and Out With ⌘ / Ctrl key and plus [+] or minus [-]
MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Tel: 86-755-36698555 Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Http://www.morlab.com E-mail: service@morlab.cn
Page 2 0f 9
REPORTNo.:SZ16110064S02
DIRECTORY
TEST REPORT DECLARATION ······················································································································· 3
1. TECHNICAL INFORMATION ······················································································································· 4
1.1. IDENTIFICATION OF APPLICANT ····················································································································· 4
1.2. IDENTIFICATION OF MANUFACTURER ··········································································································· 4
1.3. EQUIPMENT UNDER TEST (EUT) ··················································································································· 4
1.3.1. PHOTOGRAPHS OF THE EUT ························································································································ 5
1.3.2. IDENTIFICATION OF ALL USED EUT ············································································································· 6
1.4. APPLIED REFERENCE DOCUMENTS ··············································································································· 6
2. DEVICE CATEGORY AND RF EXPOSURE LIMIT ··················································································· 7
3. MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER ······························································ 8
4. RF EXPOSURE EVALUATION ······················································································································ 8
ANNEX A GENERAL INFORMATION ············································································································ 9
Change History
Issue Date Reason for change
1.0 2016-12-20 First edition
MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Tel: 86-755-36698555 Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Http://www.morlab.com E-mail: service@morlab.cn
Page 4 0f 9
REPORTNo.:SZ16110064S02
1. TECHNICAL INFORMATION
Note: the following data is based on the information by the applicant.
1.1. Identification of Applicant
Company Name: Mighty Cast, Inc
Address: 1470 Peel Street, Tower B, Suite 745 Montreal, QC H3A 1T1
CANADA
1.2. Identification of Manufacturer
Company Name: National Electronics & Watch Co., Ltd.
Address: 15/F, Shing Dao Ind., Bldg., 232 Aberdeen Main Road, Aberdeen,
Hong Kong
1.3. Equipment Under Test (EUT)
Model Name: Customizable smart band
Trade Name: M16-420
Brand Name: The Nex Band
Hardware Version: M16-420R1-1 A-12
Software Version: 2.00617
Frequency Bands: Bluetooth 4.0:2402-2480MHz;
Modulation Mode: Bluetooth 4.0: GFSK;
Antenna type: Metal plate
Development Stage: Identical prototype
MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Tel: 86-755-36698555 Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Http://www.morlab.com E-mail: service@morlab.cn
Page 5 0f 9
REPORTNo.:SZ16110064S02
1.3.1. Photographs of the EUT
1. EUT front view
2. EUT rear view
MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Tel: 86-755-36698555 Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Http://www.morlab.com E-mail: service@morlab.cn
Page 6 0f 9
REPORTNo.:SZ16110064S02
1.3.2. Identification of all used EUT
The EUT identity consists of numerical and letter characters, the letter character indicates the test
sample, and the following two numerical characters indicate the software version of the test
sample.
EUT
Identity Hardware Version Software Version
1# M16-420R1-1 A-12 2.00617
1.4. Applied Reference Documents
Leading reference documents for testing:
No. Identity Document Title
1 47 CFR§2.1093 Radiofrequency Radiation Exposure Evaluation: portable
devices
2 KDB 447498 D01v06 General RF Exposure Guidance
MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Tel: 86-755-36698555 Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Http://www.morlab.com E-mail: service@morlab.cn
Page 7 0f 9
REPORTNo.:SZ16110064S02
2. DEVICE CATEGORY AND RF EXPOSURE LIMIT
Per user manual, this device is a Bluetooth Watch. Based on 47CFR 2.1093, this device belongs
to portable device category with General Population/Uncontrolled exposure.
Portable Devices:
47CFR 2.1093(b)
For purposes of this section, a portable device is defined as a transmitting device designed to be
used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the
user.
GENERAL POPULATION / UNCONTROLLED EXPOSURE
47CFR 2.1093(d) (2)
Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body
and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a
tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the
spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a
tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the
general public may be exposed, or when persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or do not exercise control over
their exposure. Warning labels placed on consumer devices such as cellular telephones will not be
sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled
exposure in paragraph (d)(1) of this section.
MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Tel: 86-755-36698555 Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Http://www.morlab.com E-mail: service@morlab.cn
Page 8 0f 9
REPORTNo.:SZ16110064S02
3. MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER
1. Bluetooth Average output power
Band Channel Frequency
(MHz)
Output
Power(dBm)
GFSK
BT
0 2402 -0.69
19 2440 -1.51
39 2480 -2.18
4. RF EXPOSURE EVALUATION
The device only incorporates a Bluetooth transmitter, so standalone SAR evaluation is required for
Bluetooth and simultaneous SAR is not required.
Standalone transmission SAR evaluation
According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test separation
Distances 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)]·[f(GHz)] 3.0
The maximum tune-up limit power is 0.85mW @ 2.402GHz
When Bluetooth Watch is worn on the hand, so use 5mm as the most conservative minimum test
separation distance,
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)]·[f(GHz)] =0.26 3.0
So SAR evaluation is not required for this device.
MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Tel: 86-755-36698555 Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Http://www.morlab.com E-mail: service@morlab.cn
Page 9 0f 9
REPORTNo.:SZ16110064S02
ANNEX A GENERAL INFORMATION
1. Identification of the Responsible Testing Laboratory
Company Name: Shenzhen Morlab Communications Technology Co., Ltd.
Department: Morlab Laboratory
Address: FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
Responsible Test Lab Manager: Mr. Su Feng
Telephone: +86 755 36698555
Facsimile: +86 755 36698525
2. Identification of the Responsible Testing Location
***** END OF REPORT *****
Name: Shenzhen Morlab Communications Technology Co., Ltd.
Morlab Laboratory
Address: FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
Download: Customizable smart band RF Exposure Info Mighty Cast, Inc
Mirror Download [FCC.gov]Customizable smart band RF Exposure Info Mighty Cast, Inc
Document ID3246154
Application IDo9soGDKE46ZgY+6gaNVxhA==
Document DescriptionRF Exporure
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize1528795
Date Submitted2017-01-04 00:00:00
Date Available2017-01-10 00:00:00
Creation Date2016-12-20 09:17:57
Producing SoftwareAcrobat Distiller 9.3.2 (Windows)
Document Lastmod2016-12-28 15:29:33
Document Titleuntitled
Document CreatorNone
Document Author: None

Facebook Twitter Google+ RSS © FCCID.io 2017