1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE

SMART AND BLUE Smart shower head

>
FCC ID Filing: 2AKKL1
Purchase on Amazon: Smart shower head

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 2 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 3 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 4 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 5 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 6 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 7 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 8 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 9 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 10 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 11 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 12 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 13 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 14 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 15 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 16 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 17 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 18 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 19 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 20 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 21 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 22 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 23 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 24 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 25 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 26 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 27 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 28 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 29 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Page 30 of 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE

Rapport d’essais / Test Report
N° : 22192-FCC-1
Page 1 / 30
FCC Test Firm Registration Number: 171131
Industry Canada Test Firm Number: Site# 9545A-1
Matériel testé :
Equipment under test:
HYDRAO FIRST
Constructeur:
Manufacturer:
SMART AND BLUE
196, route des Vignes
38430 MOIRANS – France
Rapport délivré à :
Issued to:
SMART AND BLUE
Monsieur Vincent BLIGNY
196, route des Vignes
38430 MOIRANS – France
Marque Commerciale :
Trade Mark:
HYDRAO
Référence de la proposition :
Proposal number:
092016-22192
Date de l’essai :
Date of test:
Du 10 au 18 novembre 2016
th
th
November 10 to 18 , 2016
Objectif des essais :
Test purpose:
EMC qualification accordingly to following standards:
- CFR 47, FCC Part 15, Subpart C
(Chapter 15.249 - Operation within the bands 902–928 MHz, 2400–2483.5 MHz,
5725–5875 MHz, and 24.0–24.25 GHz)
FCC ID:
2AKKL1
Lieu du test:
Test location:
SMEE CE-Mesures
38 VOIRON - France
Test réalisé par :
Test realized by:
Jérémy BLANCHER
Conclusion :
Conclusion:
L’équipement satisfait aux prescriptions des normes citées en référence.
The appliance complies with requirements of above mentioned standards.
Ed.
Date
Modifications
Pages
December 15 , 2016
th
Initial Edition
Written by:
Approved by:
Visa
Jeremy Blancher
Laurent Chapus
La copie de ce document n'est permise que sous sa forme intégrale. Ce document est le résultat d’essais effectués sur un échantillon. Il ne préjuge pas de la
conformité de l’ensemble des produits fabriqués à l’objet essayé.
This document shall not be reproduced, except in full. This document contains results related only to the item tested. It does not imply the conformity of the
whole production to the item tested.
COORDONNEES
SMEE
Rue de Taille – ZI Des Blanchisseries
38500 VOIRON - France
TEL : 04 76 65 76 50
FAX : 04 76 66 18 30
SAS au capital de 50 000 € / RC Grenoble B534 796 453 / SIRET 534 796 453 00015 / code APE 7490B / n° TVA : FR 59 534 796 453
Rapport d’essai / Test Report
N° : 22192-FCC-1
Contents
1.
NORMATIVES REFERENCES .........................................................................................................3
2.
TEST SYNTHESIS ............................................................................................................................4
3.
EQUIPMENT UNDER TEST (EUT) ...................................................................................................5
4.
TEST CONDITIONS..........................................................................................................................6
5.
MODIFICATIONS OF THE EUT ........................................................................................................6
6.
SPECIAL ACCESSORY ....................................................................................................................6
7.
FIELD STRENGTH OF FUNDAMENTAL ..........................................................................................7
8.
FIELD STRENGTH OF HARMONICS ...............................................................................................9
9.
UNWANTED EMISSIONS ............................................................................................................... 12
Page 2 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
1.
Normatives References
FCC qualification according to:
Standards
Applied
Title
ANSI C63.4
(2014)
American National Standard for Methods of Measurement of Radio-Noise
Emissions from Low-Voltage Electrical and Electronic Equipment in the
Range of 9 kHz to 40 GHz.
ANSI C63.10
(2013)
American National Standard for Testing Unlicensed Wireless Devices
CFR47, Part 15
Telecommunication – Federal Communication Commission – Radio
frequency devices,
Sections 15.107 / 15.109 / 15.207 / 15.209 / 15.249
Page 3 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
2.
Test synthesis
TEST
Paragraph number
FCC Part 15
15.107 (a) / 15.207 (a)
Spec.
FCC Part 15
Table 15.107 (a) / 15.207 (a)
Radiated emission test
15.109 (a)
Table 15.109 (a)
N/A (2)
Field Strength of
fundamental
15.249 (a) (c)
94dBµV/m, Av / 114dBµV/m, Pk @3m
(50mV/m, Av @ 3m)
PASS
Field Strength of
harmonics
15.249 (a) (c) (e)
54dBµV/m, Av / 74dBµV/m, Pk @3m
(0.5mV/m, Av @ 3m)
PASS
Unwanted emissions
outside the specified
frequency band and
harmonics
15.209 / 15.249 (d) (e)
Whichever is less stringent, either:
PASS
Conducted emissions
test
RESULTS
(comments)
N/A (1)
- 50dB below level of fundamental, or;
- Table part 15.209 (a), as follow
Measure at 300m (Q-Peak detector)
9-490kHz: 2400µV/m/F(kHz)
Measure at 30m (Q-Peak detector)
0.490-1.705: 24000µV/m/F(kHz)
1.705-30MHz: 30µV/m
Measure at 3m (Q-Peak detector)
30MHz-88MHz : 40 dBµV/m
88MHz-216MHz : 43.5 dBµV/m
216MHz-960MHz : 46.0 dBµV/m
Above 960MHz : 54.0 dBµV/m
Measure at 3m (Av / Peak detector)
Above 1GHz : 54 dBµV/m / 74dBµV/m
N/A: Not Applicable
(1): No power cable
(2): Equipment functioning only with RF function
• General conclusion:
Measures and tests performed on the sample of the product HYDRAO FIRST, in configuration and
description presented in this test report, show compliance with standards FCC CFR 47, PART 15, Subpart
C.
Page 4 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
3.
Equipment Under Test (EUT)
Nom /
Identification
HYDRAO FIRST
Sn: N.C
Alimentation /
Power supply
12V max from internal water turbine
Auxiliaires /
Auxiliaries
- Tablet SAMSUNG, model SM-T550 (for BLE communication only)
- Water pump for closed circuit water circulation (equipment powered by water flow)
Entrées-Sorties /
Input / Output
None
Version programme /
Firmware version
Câbles pour essai /
Cables for test
Blindé /
Shielded
Prévu pour >3m /
Intended for >3m
N.C
Mode de fonctionnement /
Running mode
Equipment is a shower head, powered by internal water turbine
The tested sample is able to:
Transmit frequencies on low, middle and high channels (Bluetooth Low Energy
4.1)
Transmit frequencies in advertising mode
Programme de test /
Test program /
N.C
•
Equipment information:
- Frequency band: 2400 to 2483.5 MHz (Frequencies from 2402MHz to 2480MHz, Tx & Rx)
- Bluetooth chip: ST Microelectronics, model BLUENRG (BLE chip)
- Equipment is configured with maximum RF output power available.
- Antenna type: Integral (PCB antenna), max gain is 0dBi
- Powered by water turbine with 12V maximum
- Equipment intended for use as a portable station
- Equipment designed for continuous operation
- Extreme temperature range: +5°C and +60°C
Page 5 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
4.
Test conditions
Relative Humidity
Temperature
Power supply voltage:
Equipment under test
5.
: 50-55%
: 19-21°C
: 12V maximum at water turbine
Modifications of the EUT
None
6.
Special accessory
None
Page 6 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
7.
Field Strength of fundamental
TEST: Field strength of fundamental / FCC part 15.249
Verdict
Method: Measurements were made in a 3-meter Open Area Test Site (OATS) that complies to ANSI
C63.4-2014.
Measurements were performed with peak detector using a 100kHz RBW. The VBW is set to 300kHz.
The EUT was rotated 360° about its azimuth with the receive antenna located at various heights in
horizontal and vertical polarities. Final measurements (Peak) were then performed by rotating the EUT
360° and adjusting the receive antenna height from 1 to 4 m.
The tested equipment is set to transmit operation with modulations on lowest, middle and highest channel.
Three orthogonal axis measurements on EUT are performed to obtain the maximum peak field strength.
Laboratory Parameters:
Pass
Required prior to the test
During the test
Ambient Temperature
10 to 40 °C
19°C
Relative Humidity
10 to 90 %
60%
Limits – FCC Part 15.249 (a) (c)
Limits (dBµV/m)
Frequency (MHz)
Level / Detector / Distance
Results
94dBµV/m / Avg / 3m
114dBµV/m / Pk / 3m
Pass
2400 to 2483.5 MHz
Supplementary information:
th
Test location: SMEE – CE Mesures / Test date: November 10 , 2016
Power supply voltage: 12V max at water turbine
Test Equipment Used
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Measuring Rec.
Rohde&Schwarz
ESRP
REC-151-002
2015/7
2018/7
Horn antenna
ETS-LINDGREN
3115
ANT-141-013
2015/7
2018/7
RF cable
Div
OATS/25m
CAB-101-017
2016/3
2017/3
OATS
Div
3 / 10m
SIT-101-001
2016/8
2017/8
Antenna mast
Innco- Systems
MA4000EP
MAT-101-001
Turntable
Innco- Systems
DS1200S
PLA-101-001
Page 7 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Tabulated Results for Field Strength of fundamental
FREQ
(MHz)
2402.0
2440.0
2480.0
Field Strength 3m
Detector
Limit
Result
(dBµV/m)
(dBµV/m)
76.5
Pk
94 Av / 114 Pk
Pass
76.5
Pk
94 Av / 114 Pk
Pass
77.0
Pk
94 Av / 114 Pk
Pass
1MHz
RBW:
3m
Measurement distance:
FCC Part 15.249 (a) (c)
Limit:
Peak
Final measurement detector:
± 5.2dB (k=2)
Wide Measurement Uncertainty:
PASS
RESULT:
(1): The field strength (level) is calculated by adding the Antenna Factor
Note:
and Cable Factor, and subtracting the Amplifier Gain (if any) from the
measured reading. The basic equation is as follow:
FS = RA + AF + CF – AG
Where FS = Field Strength
RA = Receiver Amplitude
AF = Antenna Factor
CF = Cable Factor
AG = Amplifier Gain
Total factor (dB) is AF + CF – AG
Margin value = Emission level – Limit value
Page 8 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
8.
Field Strength of harmonics
TEST: Field Strength of harmonics / FCC part 15.249
Verdict
Method: Measurements were made in a 3-meter Open Area Test Site (OATS) that complies to ANSI C63.4.
Preliminary (peak) measurements were performed at an antenna to EUT separation distance of 3 meter.
The EUT was rotated 360° about its azimuth with the receive antenna located at various heights in
horizontal and vertical polarities. Final measurements (Peak) were then performed by rotating the EUT 360°
and adjusting the receive antenna height from 1 to 4 m. All frequencies were investigated in both horizontal
and vertical antenna polarity, where applicable.
The tested equipment is set to transmit operation with modulations on lowest, middle and highest channel.
Three orthogonal axis measurements on EUT are performed to obtain the maximum peak field strength.
A pre-scan frequency identification of the EUT has been performed in full anechoic chamber. The measured
radiated field of the EUT is performed at distance of 3-meters. Above 1GHz, the measuring antenna is put
closer to EUT. In this case, 3-meter correction factor is added. Antenna is 1.25-meters high.
Laboratory Parameters:
Pass
Required prior to the test
During the test
Ambient Temperature
10 to 40 °C
20°C
Relative Humidity
10 to 90 %
55%
Frequency range on each side of line
Measurement Point
30MHz – 26GHz
3 m measurement distance
Fully configured sample scanned
over the following frequency range
Limits – FCC Part 15.249 (a) (c) (e)
Frequency bands for harmonics
(MHz)
Limits (dBµV/m)
Level / Detector / Distance
Results
4800 to 4967
54.0 / AV / 3m
74.0 / PK / 3m
Pass
7200 to 7450.5
54.0 / AV / 3m
74.0 / PK / 3m
Pass
9600 to 9934
54.0 / AV / 3m
74.0 / PK / 3m
Pass
12000 to 12417.5
54.0 / AV / 3m
74.0 / PK / 3m
Pass
14400 to 14901
54.0 / AV / 3m
74.0 / PK / 3m
Pass
16800 to 17384.5
54.0 / AV / 3m
74.0 / PK / 3m
Pass
19200 to 19868
54.0 / AV / 3m
74.0 / PK / 3m
Pass
21600 to 22351.5
54.0 / AV / 3m
74.0 / PK / 3m
Pass
24000 to 24835
54.0 / AV / 3m
74.0 / PK / 3m
Pass
Supplementary information:
th
Test location: SMEE – CE Mesures / Test date: November 10 , 2016
Power supply voltage: 12V max at water turbine
Page 9 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Test Equipment Used
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Log-periodic antenna
TDK
PLP3003
ANT-101-001
2016/8
2017/8
Biconnic antenna
COM-POWER
AB- 900
ANT-101-003
2016/8
2017/8
Loop antenna
EMCO
6502
ANT-101-009
2016/8
2017/8
BiConiLog antenna
EMCO
3142B
ANT-101-010
2016/8
2017/8
Horn antenna
ETS-LINDGREN
3115
ANT-141-013
2015/7
2018/7
Horn antenna
ETS-LINDGREN
3116
ANT-161-014
2012/4
2019/4
RF cable
Div
OATS/25m
CAB-101-019
2016/3
2017/3
RF cable
Pasternack
PE302-120
CAB-131-024
2016/3
2017/3
RF cable
HUBER+SUHNER
RG214U
CAB-141-026
2016/3
2017/3
RF cable
HUBER+SUHNER
RG214U
CAB-141-029
2016/3
2017/3
RF cable
HUBER+SUHNER
SF104
CAB-141-030
2016/3
2017/3
High-pass filter
Mini-Circuit
VHF-3100+
FIL-151-006
2016/3
2017/3
Pre-amplifier
PE
PE1524
PRE-101-002
2016/3
2017/3
Anechoic chamber
COMTEST
214263
CAG-141-001
OATS
Div
10m
SIT-101-001
2016/8
2017/8
Antenna mast
Innco- Systems
MA4000EP
MAT-101-001
Turntable
Innco- Systems
DS1200S
PLA-101-001
Turntable
Innco- Systems
CT0800
PLA-141-001
Measuring Rec
Rohde&Schwarz
ESRP
REC-151-002
2015/7
2018/7
Spectrum analyzer
AGILENT HP
8563E
ASP-111-003
2016/9
2018/9
Page 10 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Tabulated Results for Field strength of harmonics
(1GHz-26GHz)
FREQ
Field level
Detector
Limit
Result
(MHz)
dBµV/m
(dBµV/m)
4960.0
46.7
Pk
Pass
54 Av / 74 Pk
7206.0
50.1
Pk
Pass
54 Av / 74 Pk
7320.0
49.6
Pk
Pass
54 Av / 74 Pk
7440.0
50.7
Pass
Pk
54 Av / 74 Pk
9608.0
50.8
Pk
Pass
54 Av / 74 Pk
9760.0
50.9
Pk
Pass
54 Av / 74 Pk
9920.0
50.5
Pk
Pass
54 Av / 74 Pk
1MHz / 3MHz (Peak)
RBW / VBW
1MHz / 10Hz (AV)
3m
Measurement distance:
FCC Part 15.249 (a) (c) (e)
Limit:
Peak / Average
Final measurement detector:
± 5.2dB (k=2)
Wide Measurement Uncertainty:
PASS
RESULT:
(1): The field strength (level) is calculated by adding the Antenna Factor and
Notes:
Cable Factor, and subtracting the Amplifier Gain (if any) from the measured
reading. The basic equation is as follow:
FS = RA + AF + CF – AG
Where FS = Field Strength
RA = Receiver Amplitude
AF = Antenna Factor
CF = Cable Factor
AG = Amplifier Gain
Total factor (dB) is AF + CF – AG
Margin value = Emission level – Limit value
(2): Peak pre-scans not performed at 3-meters distance are corrected as
follow:
[email protected] = [email protected] + 20 x log (Dm / 3m)
Where D is the measurement distance in meter
(3): All frequencies not specified have margin < -10dB (for peak and average
detector)
Page 11 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
9.
Unwanted emissions
TEST: Unwanted emissions outside fundamental and harmonics bands / FCC part 15.209,
15.249
Verdict
Method: Measurements were made in a 10 or 3-meter Open Area Test Site (OATS) that complies to ANSI
C63.4. Preliminary (peak) measurements were performed at an antenna to EUT separation distance of 3
meter. The EUT was rotated 360° about its azimuth with the receive antenna located at various heights in
horizontal and vertical polarities. Final measurements (Peak, Quasi-peak, Average) were then performed by
rotating the EUT 360° and adjusting the receive antenna height from 1 to 4 m. All frequencies were
investigated in both horizontal and vertical antenna polarity, where applicable.
A pre-scan frequency identification of the EUT has been performed in full anechoic chamber. The measured
radiated field of the EUT is performed at distance of 3-meters. Above 1GHz, the measuring antenna is put
closer to EUT. In this case, 3-meter correction factor is added. Antenna is 1.25-meters high.
Pass
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
10 to 40 °C
20°C
Relative Humidity
10 to 90 %
55%
Frequency range on each side of line
Measurement Point
9kHz – 30MHz
10 m measurement distance
30MHz – 26GHz
3 m measurement distance
Fully configured sample scanned
over the following frequency range
Limits – FCC Part 15.209, 15.249 (d) (e)
Whichever is less stringent, either:
Limits (dBµV/m)
Frequency (MHz)
Level / Detector / Distance
Results
30 to 1000
50dB below the fundamental / QP / 3m
Not used
Above 1GHz
50dB below the fundamental / Av / 3m
30dB below the fundamental / Pk / 3m
Not used
Or
Limits (dBµV/m)
Frequency (MHz)
Level / Detector / Distance
Results
0.009 to 0.490
107.6 to 72.9 / QP / 10m
Pass
0.490 to 1.705
52.9 to 42.1 / QP / 10m
Pass
1.705 to 30
48.6 / QP / 10m
Pass
30 to 88
40.0 / QP / 3m
Pass
88 to 216
43.5 / QP / 3m
Pass
216 to 960
46.0 / QP / 3m
Pass
960 to 1000
54.0 / QP / 3m
Pass
Above 1GHz
54.0 / AV / 3m
74.0 / PK / 3m
Pass
Supplementary information:
th
th
Test location: SMEE – CE Mesures / Test date: November 10 & 18 , 2016
Power supply voltage: 12V max at water turbine
Page 12 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Test Equipment Used
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Log-periodic antenna
TDK
PLP3003
ANT-101-001
2016/8
2017/8
Biconnic antenna
COM-POWER
AB- 900
ANT-101-003
2016/8
2017/8
Loop antenna
EMCO
6502
ANT-101-009
2016/8
2017/8
BiConiLog antenna
EMCO
3142B
ANT-101-010
2016/8
2017/8
Horn antenna
ETS-LINDGREN
3115
ANT-141-013
2015/7
2018/7
Horn antenna
ETS-LINDGREN
3116
ANT-161-014
2012/4
2019/4
RF cable
Div
OATS/25m
CAB-101-019
2016/3
2017/3
RF cable
Pasternack
PE302-120
CAB-131-024
2016/3
2017/3
RF cable
HUBER+SUHNER
RG214U
CAB-141-026
2016/3
2017/3
RF cable
HUBER+SUHNER
RG214U
CAB-141-029
2016/3
2017/3
RF cable
HUBER+SUHNER
SF104
CAB-141-030
2016/3
2017/3
High-pass filter
Mini-Circuit
VHF-3100+
FIL-151-006
2016/3
2017/3
Pre-amplifier
PE
PE1524
PRE-101-002
2016/3
2017/3
Anechoic chamber
COMTEST
214263
CAG-141-001
OATS
Div
10m
SIT-101-001
2016/8
2017/8
Antenna mast
Innco- Systems
MA4000EP
MAT-101-001
Turntable
Innco- Systems
DS1200S
PLA-101-001
Turntable
Innco- Systems
CT0800
PLA-141-001
Measuring Rec
Rohde&Schwarz
ESRP
REC-151-002
2015/7
2018/7
Spectrum analyzer
AGILENT HP
8563E
ASP-111-003
2016/9
2018/9
Page 13 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
FREQ
MHz
Tabulated Results for Unwanted emissions (9kHz-30MHz)
RF field @
Limit @
Antenna
Table
Margin
30m
30m
angle
angle
(QP)
(QP)
dB
Degree
Degree
dBµV/m
dBµV/m
Margin < -10dB
Correc. Fact.
(CF)
dB
Supplementary information:
Frequency list measured on the Open Area Test Site has been created with pre-scan results.
9kHz-30MHz
Frequency band investigated:
200Hz (9kHz-150kHz)
RBW:
9kHz (150kHz-30MHz)
10m
Measurement distance:
FCC Part 15.209 – 15.249
Limit:
Quasi-Peak
Final measurement detector:
± 5 dB (k=2)
Wide Measurement Uncertainty:
CF: Correction factor = Antenna factor + Cable loss
Note:
* : Measure have been done at 10m distance and corrected according to
requirements of 15.209.e)
([email protected] = [email protected])
FREQ
MHz
Tabulated Results for Unwanted emissions
(30MHz-1GHz)
Meter reading
Total factor
Field level
Limit
(QP)
(QP)
(QP)
dBµV
dB
dBµV/m
dBµV/m
Margin < -10dB
Margin
dB
Supplementary information:
Frequency list measured on the Open Area Test Site has been created with pre-scan results.
Frequency band investigated:
RBW:
Measurement distance:
Limit:
Final measurement detector:
Wide Measurement Uncertainty:
RESULT:
Notes:
30MHz-1GHz
120kHz
3m
FCC Part 15.209 – 15.249
Quasi-Peak
± 5.2dB (k=2)
PASS
(1): The field strength (level) is calculated by adding the Antenna Factor
and Cable Factor, and subtracting the Amplifier Gain (if any) from the
measured reading. The basic equation is as follow:
FS = RA + AF + CF – AG
Where FS = Field Strength
RA = Receiver Amplitude
AF = Antenna Factor
CF = Cable Factor
AG = Amplifier Gain
Total factor (dB) is AF + CF – AG
Margin value = Emission level – Limit value
Page 14 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Tabulated Results for Unwanted emissions
(1GHz-26GHz)
FREQ
Field level
Detector
Limit
Result
(MHz)
dBµV/m
(dBµV/m)
2400.0
49.2
Pk
Pass
54 Av / 74 Pk
2483.5
48.0
Pk
Pass
54 Av / 74 Pk
1MHz / 3MHz (Peak)
RBW / VBW
1MHz / 10Hz (AV)
3m
Measurement distance:
FCC Part 15.209 – 15.249
Limit:
Peak / Average
Final measurement detector:
± 5.2dB (k=2)
Wide Measurement Uncertainty:
PASS
RESULT:
(1): The field strength (level) is calculated by adding the Antenna Factor and
Notes:
Cable Factor, and subtracting the Amplifier Gain (if any) from the measured
reading. The basic equation is as follow:
FS = RA + AF + CF – AG
Where FS = Field Strength
RA = Receiver Amplitude
AF = Antenna Factor
CF = Cable Factor
AG = Amplifier Gain
Total factor (dB) is AF + CF – AG
Margin value = Emission level – Limit value
(2): Limits used are FCC part 15.209: Less stringent than fundamental field
strength minus 50dB
15.249 limits
26.5dBµV/m Av @ 3m (= 76.5dBµV/m - 50dB)
(3): Peak pre-scans not performed at 3-meters distance are corrected as
follow:
[email protected] = [email protected] + 20 x log (Dm / 3m)
Where D is the measurement distance in meter
(4): All frequencies not specified have margin < -10dB (for peak and average
detector)
Page 15 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Band-edge compliance (Radiated)
Low band-edge compliance
High band-edge compliance
F1 = 2400MHz
Peak level below 2400MHz is 49.2dBµV/m max at 3m
(Average limit is 54dBµV/m - Peak limit is 74dBµV/m @ 3m )
RESULT: PASS
Note: Radiated measurement
F1 = 2483.5MHz
Peak level below 2483.5MHz is 48.0dBµV/m max at 3m
(Average limit is 54dBµV/m - Peak limit is 74dBµV/m @ 3m )
RESULT: PASS
Note: Radiated measurement
Page 16 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 30MHz-1GHz / 3m / Horizontal / Transmit mode)
80
dBµV/m
70
60
50
40
30
20
10
30MHz
100M
1.002GHz
Fréquence (MHz)
Notes: Pre-scan graph only for identification purpose.
Same result for transmit mode at 2402MHz, 2440MHz or 2480MHz.
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
30MHz-1GHz
dBµV/m
100kHz
Horizontal
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 17 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 30MHz-1GHz / 3m / Vertical / Transmit mode)
80
dBµV/m
70
60
50
40
30
20
10
30MHz
100M
1.002GHz
Fréquence (MHz)
Notes: Pre-scan graph only for identification purpose.
Same result for transmit mode at 2402MHz, 2440MHz or 2480MHz.
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
30MHz-1GHz
dBµV/m
100kHz
Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 18 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 1GHz-3.6GHz / 3m / Horizontal & Vertical / Transmit mode at 2402MHz)
80
dBµV/m
2.4016566 G / 71.5
70
60
50
40
30
20
10
1GHz
3.6GHz
Fréquence (MHz)
80
2.4016566 G / 76.8
dBµV/m
70
60
50
40
30
20
10
1GHz
3.6GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
1GHz-3.6GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 19 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 3.6GHz-12GHz / 3m / Horizontal & Vertical / Transmit mode at 2402MHz)
80
dBµV/m
70
60
50
40
30
20
10
3.6GHz
10G
12GHz
10G
12GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
3.6GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
3.6GHz-12GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 20 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 12GHz-18GHz / 3m / Horizontal & Vertical / Transmit mode at 2402MHz)
80
dBµV/m
70
60
50
40
30
20
10
12GHz
18GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
12GHz
18GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
12GHz-18GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 21 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 18GHz-26GHz / 3m / Horizontal & Vertical / Transmit mode at 2402MHz)
80
dBµV/m
70
60
50
40
30
20
10
18GHz
26GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
18GHz
26GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
18GHz-26GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 22 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 1GHz-3.6GHz / 3m / Horizontal & Vertical / Transmit mode at 2440MHz)
80
dBµV/m
2.4397955 G / 72.2
70
60
50
40
30
20
10
1GHz
3.6GHz
Fréquence (MHz)
80
2.4397955 G / 77
dBµV/m
70
60
50
40
30
20
10
1GHz
3.6GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
1GHz-3.6GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 23 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 3.6GHz-12GHz / 3m / Horizontal & Vertical / Transmit mode at 2440MHz)
80
dBµV/m
70
60
50
40
30
20
10
3.6GHz
10G
12GHz
10G
12GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
3.6GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
3.6GHz-12GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 24 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 12GHz-18GHz / 3m / Horizontal & Vertical / Transmit mode at 2440MHz)
80
dBµV/m
70
60
50
40
30
20
10
12GHz
18GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
12GHz
18GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
12GHz-18GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 25 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 18GHz-26GHz / 3m / Horizontal & Vertical / Transmit mode at 2440MHz)
80
dBµV/m
70
60
50
40
30
20
10
18GHz
26GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
18GHz
26GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
18GHz-26GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 26 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 1GHz-3.6GHz / 3m / Horizontal & Vertical / Transmit mode at 2480MHz)
80
dBµV/m
2.4798104 G / 70.8
70
60
50
40
30
20
10
1GHz
3.6GHz
Fréquence (MHz)
80
2.4798104 G / 76.5
dBµV/m
70
60
50
40
30
20
10
1GHz
3.6GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
1GHz-3.6GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 27 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 3.6GHz-12GHz / 3m / Horizontal & Vertical / Transmit mode at 2480MHz)
80
dBµV/m
70
60
50
40
30
20
10
3.6GHz
10G
12GHz
10G
12GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
3.6GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
3.6GHz-12GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 28 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 12GHz-18GHz / 3m / Horizontal & Vertical / Transmit mode at 2480MHz)
80
dBµV/m
70
60
50
40
30
20
10
12GHz
18GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
12GHz
18GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
12GHz-18GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 29 / 30
Rapport d’essai / Test Report
N° : 22192-FCC-1
Graphical representation of Radiated Disturbance Measurement (Peak detection, Anechoic chamber
pre-scan, 18GHz-26GHz / 3m / Horizontal & Vertical / Transmit mode at 2480MHz)
80
dBµV/m
70
60
50
40
30
20
10
18GHz
26GHz
Fréquence (MHz)
80
dBµV/m
70
60
50
40
30
20
10
18GHz
26GHz
Fréquence (MHz)
Frequency band investigated:
Unit :
RBW :
Antenna polarization :
Voltage:
Limit:
Measurement detector:
Wide Measurement Uncertainty:
18GHz-26GHz
dBµV/m
1MHz
Horizontal & Vertical
12V max. at water turbine
15.209
Peak
± 5dB (k=2)
Page 30 / 30
Download: 1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Mirror Download [FCC.gov]1 Smart shower head Test Report 22192-FCC-1 (Smart and Blue, Hydrao) SMART AND BLUE
Document ID3251811
Application IDYIKXB7ImjOgvzcCaoa70ug==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize33.81kB (422651 bits)
Date Submitted2017-01-09 00:00:00
Date Available2017-01-11 00:00:00
Creation Date2017-01-02 10:29:32
Producing SoftwareGPL Ghostscript 9.06
Document Lastmod2017-01-02 10:29:32
Document Title22192-FCC-1 (Smart and Blue, Hydrao)
Document CreatorPDFCreator Version 1.6.0
Document Author: Labo

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 30
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:7e8d25d5-d329-11e6-0000-85142772963a
Producer                        : GPL Ghostscript 9.06
Keywords                        : ()
Modify Date                     : 2017:01:02 10:29:32+01:00
Create Date                     : 2017:01:02 10:29:32+01:00
Creator Tool                    : PDFCreator Version 1.6.0
Document ID                     : uuid:7e8d25d5-d329-11e6-0000-85142772963a
Format                          : application/pdf
Title                           : 22192-FCC-1 (Smart and Blue, Hydrao)
Creator                         : Labo
Description                     : ()
Author                          : Labo
Subject                         : 

Facebook Twitter Google+ RSS © FCCID.io 2017