FCC REPORT
Report Reference No. .................... : TRE1612009603 R/C…….: 46619
FCC ID ............................................. : ZSW-10-008
Applicant’s name ........................... : b mobile HK Limited
Address ............................................. : Flat 18; 14/F Block 1; Golden Industrial Building; 16-26 Kwai
Tak Street; Kwai Chung;New Territories,HONG KONG
Manufacturer......................................: b mobile HK Limited
Address...............................................: Flat 18; 14/F Block 1; Golden Industrial Building;16-26 KwaiTak
Street; Kwai Chung; New Territories; Hong Kong
Test item description .................... : Mobile Phone
Trade Mark ....................................... : Bmobile
Model/Type reference ....................... : W100
Listed Model(s) ................................. : -
Standard ......................................... : 47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014
Date of receipt of test sample………..: Dec. 16, 2016
Date of testing…………………………: Dec. 19, 2016 - Dec. 29, 2016
Date of issue…………………………...: Dec. 29, 2016
Result .................. …………………...: Pass
Compiled by
( position+printed name+signature) .. :
File administrators Shayne Zhu
Supervised by
( position+printed name+signature) .. :
Project Engineer Lion Cai
Approved by
( position+printed name+signature) .. :
RF Manager Hans Hu
Testing Laboratory Name ............. : Shenzhen Huatongwei International Inspection Co., Ltd.
Address ............................................. : 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
Tianliao, Gongming, Shenzhen, China
Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and
source of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility
for and will not assume liability for damages resulting from the reader's interpretation of the reproduced
material due to its placement and context.
Report No: TRE1612009603 Page: 2 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
Contents
1.1.Test Standards 3
1.2.Report version 3
3.SUMMARY 5
3.1.Client Information 5
3.2.Product Description 5
3.3.EUT operation mode 6
3.4.EUT configuration 6
3.5.Configuration of Tested System 7
4.TEST ENVIRONMENT 8
4.1.Address of the test laboratory 8
4.2.Test Facility 8
4.3.Environmental conditions 9
4.4.Statement of the measurement uncertainty 10
5.TEST CONDITIONS AND RESULTS 11
5.1.Conducted Emissions Test 11
5.2.Radiated Emission Test 14
6.TEST SETUP PHOTOS OF THE EUT 18
7.EXTERNAL AND INTERNAL PHOTOS OF THE EUT 19
1. Test standards and Report version
Report No: TRE1612009603 Page: 3 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz
1.2. Report version
Version No. Date of issue Description
00 Dec. 29, 2016 Original
Report No: TRE1612009603 Page: 4 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
2. Test Description
Test Item FCC Rule Result
Conducted Emissions Test 15.107 Pass
Radiated Emission Test 15.109 Pass
Note: The measurement uncertainty is not included in the test result.
Report No: TRE1612009603 Page: 5 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
3. SUMMARY
3.1. Client Information
Applicant: b mobile HK Limited
Address: Flat 18; 14/F Block 1; Golden Industrial Building; 16-26 Kwai Tak Street;
Kwai Chung;New Territories,HONG KONG
Manufacturer: b mobile HK Limited
Address: Flat 18; 14/F Block 1; Golden Industrial Building; 16-26 Kwai Tak Street;
Kwai Chung;New Territories,HONG KONG
3.2. Product Description
Name of EUT Mobile Phone
Trade Mark: Bmobile
Model No.: W100
Listed Model(s): -
IMEI : 869748022331551
Power supply: DC 3.7V From internal battery
Adapter information: Input: 100-240Va.c., 50-60Hz, 0.15A
Output: 5Vd.c., 500mA
Report No: TRE1612009603 Page: 6 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
3.3. EUT operation mode
Test mode Playing Video Connect to PC
(Down loading) Camera Adapter
1
2
3
Note:
1. is operation mode.
Pre-scan above all test mode, found below test mode which it was worse case mode.
Test item Test mode (Worse case mode)
Conducted emission Mode 2
Radiated emission Mode 2
3.4. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:
- supplied by the manufacturer
- supplied by the lab
Length (m) :
Shield :
Detachable :
Manufacturer :
Model No. : -
Report No: TRE1612009603 Page: 7 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
3.5. Configuration of Tested System
Configuration of Tested System
Equipment Used in Tested System
No. Equipment Manufacturer Model
No. Serial No. Length shielded/unshielded Notes
1 PC DELL
DIMEN
SION
E520
1RNN42X / / DOC
2 Printer ESPOn C3990 C3990A / / DOC
3 Mouse DELL MO56U
OA G0E02SY7 1.00m unshielded DOC
4 Display DELL 1707FPt CN-OFC237-71618-
65G-AAKC / / DOC
5 Keyboard DELL L100
CNRH65665890726
009L / / DOC
6 USB Cable
(EUT to PC)
ITALCOM
GROUP USB 2.0 N/A 0.80m unshielded N/A
7
USB Cable
(Printer to
PC)
Genshuo USB 2.0 N/A 1.20m unshielded N/A
8 Power line / / N/A 1.00m unshielded N/A
PC
EUT
AC
120V/60Hz
Printer
Mouse
AC 120V/60Hz
Dis
p
la
y
Keyboard
Report No: TRE1612009603 Page: 8 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory:Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
CNAS-Lab Code: L1225
Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories
(identical to ISO/IEC17025: 2005 General Requirements) for the Competence of Testing and Calibration
Laboratories, Date of Registration: February 28, 2015. Valid time is until February 27, 2018.
A2LA-Lab Cert. No. 3902.01
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing. Valid time is until December 31, 2016.
FCC-Registration No.: 317478
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 317478, Renewal date Jul. 18, 2014, valid time is until Jul. 18,
2017.
IC-Registration No.: 5377A&5377B
The 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377A on Dec. 31, 2013, valid time is until Dec. 31, 2016.
Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B on Dec.03, 2014, valid time is until Dec.03, 2017.
ACA
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.
Report No: TRE1612009603 Page: 9 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
Equipments Used during the Test
Conducted Emission
Item Test Equipment Manufacturer Model No. Serial No. Last Cal.
1 EMI TEST RECEIVER Rohde & Schwarz ESCI 100106 11/13/2016
2 ARTIFICIAL MAINS Rohde & Schwarz ESH2-Z5 100028 11/13/2016
3 PULSE LIMITER Rohde & Schwarz ESHSZ2 100044 11/13/2016
4 EMI TEST SOFTWARE Rohde & Schwarz ES-K1 N/A N/A
Radiated Emission
Item Test Equipment Manufacturer Model No. Serial No. Last Cal.
1 ULTRA-BROADBAND
ANTENNA ShwarzBeck VULB9163 538 11/13/2016
2 EMI TEST RECEIVER Rohde & Schwarz ESI 26 100009 11/13/2016
3 EMI TEST Software Audix E3 N/A N/A
4 TURNTABLE MATURO TT2.0 ---- N/A
5 ANTENNA MAST MATURO TAM-4.0-P ---- N/A
6 EMI TEST Software Rohde & Schwarz ESK1 N/A N/A
7 ULTRA-BROADBAND
ANTENNA Rohde&Schwarz HL562 100015 11/13/2016
8 Amplifer Sonoma 310N E009-13 11/13/2016
9 JS amplifer Rohde & Schwarz JS4-00101800-
28-5A F201504 11/13/2016
11 TURNTABLE ETS 2088 2149 N/A
12 ANTENNA MAST ETS 2075 2346 N/A
13 HORN ANTENNA Rohde&Schwarz HF906 100039 11/13/2016
The calibration interval was one year.
4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature: 15~35°C
lative Humidity: 30~60 %
Air Pressure: 950~1050mba
Report No: TRE1612009603 Page: 10 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.
Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:
Test Range Measurement
Uncertainty Notes
Radiated Emission 30~1000MHz 4.24 dB (1)
Radiated Emission 1~18GHz 5.16 dB (1)
Radiated Emission 18-40GHz 5.54 dB (1)
Conducted Disturbance 0.15~30MHz 3.39 dB (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2.
Report No: TRE1612009603 Page: 11 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
Frequency range (MHz) Limit (dBuV)
Quasi-peak Average
0.15-0.5 66 to 56* 56 to 46*
0.5-5 56 46
5-30 60 50
* Decreases with the logarithm of the frequency.
TEST CONFIGURATION
TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4-2014.
2. The EUT was placed on a platform of nominal size, 1 m by 1.5 m, raised 80 cm above theconducting
ground plane. The vertical conducting plane was located 40 cm to the rear of theEUT. All other surfaces
of EUT were at least 80 cm from any other grounded conductingsurface.
3. The EUT and simulators are connected to the main power through a line impedancestabilization network
(LISN). The LISN provides a 50 ohm /50uH coupling impedance for themeasuring equipment.
4. The peripheral devices are also connected to the main power through aLISN. (Please refer to the block
diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were foldedback and
forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHzusing a
receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.
TEST MODE:
Please refer to the clause 3.3
TEST RESULTS
Passed Not Applicable
Note:Transd=Cable lose+ PULSE LIMITER factor+ ARTIFICIAL MAINS factor; Margin= Limit -Level
Report No: TRE1612009603 Page: 12 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
Test Line: L
Report No: TRE1612009603 Page: 13 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
Test Line: N
Report No: TRE1612009603 Page: 14 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
5.2. Radiated Emission Test
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209
Frequency Limit (dBuV/m @3m) Value
30MHz-88MHz 40.00 Quasi-peak
88MHz-216MHz 43.50 Quasi-peak
216MHz-960MHz 46.00 Quasi-peak
960MHz-1GHz 54.00 Quasi-peak
Above 1GHz 54.00 Average
74.00 Peak
TEST CONFIGURATION
30MHz ~ 1GHz
Above 1GHz
TEST PROCEDURE
1. The EUT was tested according to ANSI C63.4:2014.
2. The EUT is placed on a turn table which is 0.8 meter above ground. The turn table is rotated360 degrees
to determine the position of the maximum emission level.
3. The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4. The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
repeated for both horizontal and vertical polarization of the antenna.
5. Use the following spectrum analyzer settings
(1) Span shall wide enough to fully capture the emission being measured;
(2) Below 1GHz, RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
Report No: TRE1612009603 Page: 15 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
the quasi-peak detector and reported.
(3) Above 1GHz, RBW=1MHz, VBW=3MHz
TEST MODE:
Please refer to the clause 3.3
TEST RESULTS
Passed Not Applicable
Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
Report No: TRE1612009603 Page: 16 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
Report No: TRE1612009603 Page: 17 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
Report No: TRE1612009603 Page: 18 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
6. Test Setup Photos of the EUT
Conducted Emission Connect to PC
Radiated Emission (30MHz-1GHz) Connect to PC
Radiated Emission (above 1GHz) Connect to PC
Report No: TRE1612009603 Page: 19 of 19 Issued: 2016-12-29
Report Template Version: H00 (2016-08)
7. External and Internal Photos of the EUT
Reference to the test report No.: TRE1612009601.
.......................End of Report.........................
Download: Mobile Phone Test Report - TRE1612009603-b mobile--Part15B b mobile HK Limited
Mirror Download [FCC.gov]Mobile Phone Test Report - TRE1612009603-b mobile--Part15B b mobile HK Limited
Document ID3252301
Application IDy4TjSXzqjYH9wlj6+c0OQA==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize762333
Date Submitted2017-01-09 00:00:00
Date Available2017-01-09 00:00:00
Creation Date2017-01-03 13:33:22
Producing SoftwareAcrobat Distiller 9.5.5 (Windows)
Document Lastmod2017-01-03 13:33:22
Document TitleMicrosoft Word - TRE1612009603-b mobile--Part15B
Document CreatorPScript5.dll Version 5.2.2
Document Author: 0391

Facebook Twitter Google+ RSS © FCCID.io 2017