Appendix B
System Validations
Date/Time: 11/29/2016 6:52:54 PM
Head 5750 MHz validation
DUT: 5.8 dipole;
Communication System: CW; Frequency: 5750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5750 MHz; σ = 5.1 mho/m; εr = 36.86; ρ = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY4 (High Precision Assessment)
DASY4 Configuration:
zProbe: EX3DV4 - SN7385; ConvF(4.75, 4.75, 4.75); Calibrated: 3/2/2016
zSensor-Surface: 2mm (Mechanical Surface Detection)
zElectronics: DAE3 Sn493; Calibrated: 5/13/2016
zPhantom: SAM with CRP; Type: SAM;
zMeasurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145
Area Scan (41x61x1): Measurement grid: dx=5mm, dy=5mm Maximum value of SAR
(interpolated) = 16.3 mW/g
Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 37.4 V/m; Power Drift = -0.049 dB
Peak SAR (extrapolated) = 31.0 W/kg
SAR(1 g) = 7.58 mW/g; SAR(10 g) = 2.17 mW/g
Maximum value of SAR (measured) = 14.7 mW/g
Date/Time: 12/12/2016 8:12:56 PM
Body 5750 MHz validation
DUT: 5.8 dipole;
Communication System: CW; Frequency: 5750 MHz;Duty Cycle: 1:1
Medium parameters used: f =5750 MHz; σ = 6.1 mho/m; εr = 50.6; ρ = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY4 (High Precision Assessment)
DASY4 Configuration:
zProbe: EX3DV4 - SN7385; ConvF(4.13, 4.13, 4.13); Calibrated: 3/2/2016
zSensor-Surface: 2mm (Mechanical Surface Detection)
zElectronics: DAE3 Sn493; Calibrated: 5/13/2016
zPhantom: SAM with CRP; Type: SAM;
zMeasurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145
Area Scan (41x61x1): Measurement grid: dx=5mm, dy=5mm Maximum value of SAR
(interpolated) = 16.8 mW/g
Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.32 V/m; Power Drift = 0.052 dB
Peak SAR (extrapolated) = 32.1 W/kg
SAR(1 g) = 7.12 mW/g; SAR(10 g) = 2.03 mW/g
Maximum value of SAR (measured) = 17.2 mW/g
Date/Time: 11/30/2016 11:46:42 AM
2450 Head Validation-CW-200mW input power
DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2
Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2450 MHz; σ = 1.69 mho/m; εr = 35.58; ρ = 1000 kg/
m3 Phantom section: Flat Section
Measurement Standard: DASY4 (High Precision Assessment)
DASY4 Configuration:
zProbe: ES3DV3 - SN3035; ConvF(4.5, 4.5, 4.5); Calibrated: 5/17/2016
zSensor-Surface: 4mm (Mechanical Surface Detection)
zElectronics: DAE3 Sn493; Calibrated: 5/13/2016
zPhantom: SAM with CRP; Type: SAM; Serial:
zMeasurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145
Area Scan (51x81x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR
(interpolated) = 12.8 mW/g
Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 82.3 V/m; Power Drift = 0.016 dB
Peak SAR (extrapolated) = 22.9 W/kg
SAR(1 g) = 10.8 mW/g; SAR(10 g) = 4.96 mW/g
Maximum value of SAR (measured) = 12.3 mW/g
Date/Time: 12/12/2016 2:10:54 PM
2450 Body Validation
DUT: Dipole 2450 MHz;
Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2450 MHz; σ = 1.97 mho/m; εr = 51.93; ρ = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY4 (High Precision Assessment)
DASY4 Configuration:
zProbe: ES3DV3 - SN3035; ConvF(4.31, 4.31, 4.31); Calibrated: 5/17/2016
zSensor-Surface: 4mm (Mechanical Surface Detection)
zElectronics: DAE3 Sn493; Calibrated: 5/13/2016
zPhantom: SAM with CRP; Type: SAM;
zMeasurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145
Area Scan (51x81x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 16.1 mW/g
Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 85.8 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 27.1 W/kg
SAR(1 g) = 13.0 mW/g; SAR(10 g) = 5.95 mW/g
Maximum value of SAR (measured) = 14.8 mW/g
Download: Body Worn POV Camera System RF Exposure Info None TASER International

Document ID3252963
Application IdcLwif3EftMUVNBXgFR9OSA==
Document DescriptionSAR Appendix B System Validation
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize428708
Date Submitted2017-01-09 00:00:00
Date Available2017-01-09 00:00:00
Creation Date2016-12-21 12:29:16
Producing SoftwareMicrosoft Word 2010
Document Lastmod2016-12-22 09:09:12
Document TitleNone
Document CreatorMicrosoft Word 2010
Document Author: Amanda Reed

Facebook Twitter Google+ RSS © FCCID.io 2017