FCC REPORT
Report Reference No. .................... :
TRE1612016405
R/C…….: 27074
FCC ID ............................................. :
ZSW-30-041
Applicant’s name ........................... :
b mobile HK Limited
Address ............................................. :
Flat 18; 14/F Block 1; Golden Industrial Building;16-26 Kwai
Tak Street; Kwai Chung; New Territories; Hong Kong.
Manufacturer......................................:
b mobile HK Limited
Address...............................................:
Flat 18; 14/F Block 1; Golden Industrial Building;16-26 Kwai
Tak Street; Kwai Chung; New Territories; Hong Kong.
Test item description .................... :
Mobile Phone
Trade Mark ....................................... :
Bmobile
Model/Type reference ....................... :
AX680+
Listed Model(s) ................................. :
-
Standard ......................................... :
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014
Date of receipt of test sample………..:
Dec. 27, 2016
Date of testing…………………………:
Dec. 27, 2016 - Dec. 30, 2016
Date of issue…………………………...:
Jan. 03, 2017
Result .................. …………………...:
Pass
Compiled by
( position+printed name+signature) .. :
File administrators Becky Liang
Supervised by
( position+printed name+signature) .. :
Project Engineer Lion Cai
Approved by
( position+printed name+signature) .. :
RF Manager Hans Hu
Testing Laboratory Name ............. :
Shenzhen Huatongwei International Inspection Co., Ltd.
Address ............................................. :
1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
Tianliao, Gongming, Shenzhen, China
Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and
source of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility
for and will not assume liability for damages resulting from the reader's interpretation of the reproduced
material due to its placement and context.
TRE1612016405
Page:
2 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
Contents
1. T E S T S T A N D A R D S A N D R E P O R T V E R S I O N 3
1.1. Test Standards 3
1.2. Report version 3
2. T E S T D E S C R I P T I O N 4
3. S U M M A R Y 5
3.1. Client Information 5
3.2. Product Description 5
3.3. EUT operation mode 6
3.4. EUT configuration 6
3.5. Configuration of Tested System 7
4. T E S T E N V I R O N M E N T 8
4.1. Address of the test laboratory 8
4.2. Test Facility 8
4.3. Environmental conditions 9
4.4. Statement of the measurement uncertainty 10
5. T E S T C O N D I T I O N S A N D R E S U L TS 11
5.1. Conducted Emissions Test 11
5.2. Radiated Emission Test 14
6. T E S T S E T U P P H O T O S O F T H E E U T 18
7. E X T E R N A L A N D I N T E R N A L P H O T O S O F T H E E UT 18
TRE1612016405
Page:
3 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
1. T e s t s t a n d a r d s a n d R e p o r t v e r s i o n
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz
1.2. Report version
Version No.
Date of issue
Description
00
Jan. 03, 2017
Original
TRE1612016405
Page:
4 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
2. T e s t D e s c r i p t i o n
Test Item
FCC Rule
Result
Conducted Emissions Test
15.107
Pass
Radiated Emission Test
15.109
Pass
Note: The measurement uncertainty is not included in the test result.
TRE1612016405
Page:
5 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
3. S U M M A R Y
3.1. Client Information
Applicant:
b mobile HK Limited
Address:
Flat 18; 14/F Block 1; Golden Industrial Building;16-26 Kwai Tak Street;
Kwai Chung; New Territories; Hong Kong.
Manufacturer:
b mobile HK Limited
Address:
Flat 18; 14/F Block 1; Golden Industrial Building;16-26 Kwai Tak Street;
Kwai Chung; New Territories; Hong Kong.
3.2. Product Description
Name of EUT
Mobile Phone
Trade Mark:
Bmobile
Model No.:
AX680+
Listed Model(s):
-
IMEI :
355196080000216
Power supply:
DC 3.7V From internal battery
Adapter information:
Input: 100-240Va.c., 50-60Hz, 0.4A
Output: 5Vd.c., 600mA
TRE1612016405
Page:
6 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
3.3. EUT operation mode
Test mode
Playing Video
Connect to PC
(Down loading)
Camera
Adapter
1
2
3
Note:
1. ■ is operation mode.
Pre-scan above all test mode, found below test mode which it was worse case mode.
Test item
Test mode (Worse case mode)
Conducted emission
Mode 2
Radiated emission
Mode 2
3.4. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:
- supplied by the manufacturer
- supplied by the lab
Length (m) :
Shield :
Detachable :
Manufacturer :
Model No. :
-
TRE1612016405
Page:
7 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
3.5. Configuration of Tested System
Configuration of Tested System
Equipment Used in Tested System
No.
Equipment
Manufacturer
Model
No.
Serial No.
Length
shielded/unshielded
Notes
1
PC
DELL
DIMEN
SION
E520
1RNN42X
/
/
DOC
2
Printer
ESPOn
C3990
C3990A
/
/
DOC
3
Mouse
DELL
MO56U
OA
G0E02SY7
1.00m
unshielded
DOC
4
Display
DELL
1707FPt
CN-OFC237-71618-
65G-AAKC
/
/
DOC
5
Keyboard
DELL
L100
CNRH65665890726
009L
/
/
DOC
6
USB Cable
(EUT to PC)
ITALCOM
GROUP
USB 2.0
N/A
0.80m
unshielded
N/A
7
USB Cable
(Printer to
PC)
Genshuo
USB 2.0
N/A
1.20m
unshielded
N/A
8
Power line
/
/
N/A
1.00m
unshielded
N/A
PC
EUT
AC
120V/60Hz
Printer
Mouse
AC 120V/60Hz
Display
Keyboard
TRE1612016405
Page:
8 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
4. T E S T E N V I R O N M E N T
4.1. Address of the test laboratory
Laboratory:Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
CNAS-Lab Code: L1225
Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories
(identical to ISO/IEC17025: 2005 General Requirements) for the Competence of Testing and Calibration
Laboratories, Date of Registration: February 28, 2015. Valid time is until February 27, 2018.
A2LA-Lab Cert. No. 3902.01
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing. Valid time is until December 31, 2016.
FCC-Registration No.: 317478
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 317478, Renewal date Jul. 18, 2014, valid time is until Jul. 18,
2017.
IC-Registration No.: 5377A&5377B
The 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377A on Dec. 31, 2013, valid time is until Dec. 31, 2016.
Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B on Dec.03, 2014, valid time is until Dec.03, 2017.
ACA
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.
TRE1612016405
Page:
9 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
Equipments Used during the Test
Conducted Emission
Item
Test Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
1
EMI TEST RECEIVER
Rohde & Schwarz
ESCI
100106
11/13/2016
2
ARTIFICIAL MAINS
Rohde & Schwarz
ESH2-Z5
100028
11/13/2016
3
PULSE LIMITER
Rohde & Schwarz
ESHSZ2
100044
11/13/2016
4
EMI TEST SOFTWARE
Rohde & Schwarz
ES-K1
N/A
N/A
Radiated Emission
Item
Test Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
1
ULTRA-BROADBAND
ANTENNA
ShwarzBeck
VULB9163
538
11/13/2016
2
EMI TEST RECEIVER
Rohde & Schwarz
ESI 26
100009
11/13/2016
3
EMI TEST Software
Audix
E3
N/A
N/A
4
TURNTABLE
MATURO
TT2.0
----
N/A
5
ANTENNA MAST
MATURO
TAM-4.0-P
----
N/A
6
EMI TEST Software
Rohde & Schwarz
ESK1
N/A
N/A
7
ULTRA-BROADBAND
ANTENNA
Rohde&Schwarz
HL562
100015
11/13/2016
8
Amplifer
Sonoma
310N
E009-13
11/13/2016
9
JS amplifer
Rohde & Schwarz
JS4-00101800-
28-5A
F201504
11/13/2016
11
TURNTABLE
ETS
2088
2149
N/A
12
ANTENNA MAST
ETS
2075
2346
N/A
13
HORN ANTENNA
Rohde&Schwarz
HF906
100039
11/13/2016
The calibration interval was one year.
4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:
15~35°C
lative Humidity:
30~60 %
Air Pressure:
950~1050mba
TRE1612016405
Page:
10 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.
Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:
Test
Range
Measurement
Uncertainty
Notes
Radiated Emission
30~1000MHz
4.24 dB
(1)
Radiated Emission
1~18GHz
5.16 dB
(1)
Radiated Emission
18-40GHz
5.54 dB
(1)
Conducted Disturbance
0.15~30MHz
3.39 dB
(1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2.
TRE1612016405
Page:
11 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
5. T E S T C O N D I T I O N S A N D R E S U L T S
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
Frequency range (MHz)
Limit (dBuV)
Quasi-peak
Average
0.15-0.5
66 to 56*
56 to 46*
0.5-5
56
46
5-30
60
50
* Decreases with the logarithm of the frequency.
TEST CONFIGURATION
TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4-2014.
2. The EUT was placed on a platform of nominal size, 1 m by 1.5 m, raised 80 cm above theconducting
ground plane. The vertical conducting plane was located 40 cm to the rear of theEUT. All other surfaces
of EUT were at least 80 cm from any other grounded conductingsurface.
3. The EUT and simulators are connected to the main power through a line impedancestabilization network
(LISN). The LISN provides a 50 ohm /50uH coupling impedance for themeasuring equipment.
4. The peripheral devices are also connected to the main power through aLISN. (Please refer to the block
diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were foldedback and
forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHzusing a
receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.
TEST MODE:
Please refer to the clause 3.3
TEST RESULTS
Passed Not Applicable
Note:Transd=Cable lose+ PULSE LIMITER factor+ ARTIFICIAL MAINS factor; Margin= Limit -Level
TRE1612016405
Page:
12 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
Test Line:
L
TRE1612016405
Page:
13 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
Test Line:
N
TRE1612016405
Page:
14 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
5.2. Radiated Emission Test
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209
Frequency
Limit (dBuV/m @3m)
Value
30MHz-88MHz
40.00
Quasi-peak
88MHz-216MHz
43.50
Quasi-peak
216MHz-960MHz
46.00
Quasi-peak
960MHz-1GHz
54.00
Quasi-peak
Above 1GHz
54.00
Average
74.00
Peak
TEST CONFIGURATION
30MHz ~ 1GHz
Above 1GHz
TEST PROCEDURE
1. The EUT was tested according to ANSI C63.4:2014.
2. The EUT is placed on a turn table which is 0.8 meter above ground. The turn table is rotated360 degrees
to determine the position of the maximum emission level.
3. The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4. The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
repeated for both horizontal and vertical polarization of the antenna.
5. Use the following spectrum analyzer settings
(1) Span shall wide enough to fully capture the emission being measured;
(2) Below 1GHz, RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
TRE1612016405
Page:
15 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
the quasi-peak detector and reported.
(3) Above 1GHz, RBW=1MHz, VBW=3MHz
TEST MODE:
Please refer to the clause 3.3
TEST RESULTS
Passed Not Applicable
Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss Preamplifier Factor
TRE1612016405
Page:
16 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
TRE1612016405
Page:
17 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
TRE1612016405
Page:
18 of 18
Issued:
2017-01-03
Report Template Version: H00 (2016-08)
6. T e s t S e t u p P h o t o s o f t h e E U T
Conducted Emission Connect to PC
Radiated Emission (30MHz-1GHz) Connect to PC
Radiated Emission (above 1GHz) Connect to PC
7. E x t e r n a l a n d I n t e r n a l P h o t o s o f t h e E U T
Reference to the test report No.: TRE1612016401.
.......................End of Report.........................
Download: Mobile Phone Test Report EMC TRF Template b mobile HK Limited
Mirror Download [FCC.gov]Mobile Phone Test Report EMC TRF Template b mobile HK Limited
Document ID3253544
Application IDECXIMJifQjYA8WKeWxXgkQ==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize79.91kB (998891 bits)
Date Submitted2017-01-10 00:00:00
Date Available2017-01-10 00:00:00
Creation Date2017-01-04 15:31:46
Producing SoftwareMicrosoft Word 2010
Document Lastmod2017-01-04 15:31:46
Document TitleEMC TRF Template
Document CreatorMicrosoft Word 2010
Document Author: Tara Mitchell

Facebook Twitter Google+ RSS © FCCID.io 2017