TEST REPORT
FOR FCC PART 15 SUBPART C 15.249
Report Reference No. ................. : CTL1610280303-WF
Compiled by:
( position+printed name+signature)
Allen Wang
(File administrators)
Tested by:
( position+printed name+signature)
Nice Nong
(Test Engineer)
Approved by:
( position+printed name+signature)
Tracy Qi
(Manager)
Product Name .............................. : Portable Speaker
Model/Type reference ................. : A026
List Model(s) ................................ : MMA3628
Trade Mark ................................... : AVWOO, MAGNAVOX
FCC ID .......................................... : 2AEDKA026
Applicant’s name ........................ : SHENZHEN AVWOO TECHNOLOGY CO., LTD.
Address of applicant .................. : 3F, Block 2, Longtang Industrial Park, Liuyue Community,
Henggang Street, Longgang District, Shenzhen, China
Test Firm ...................................... : Shenzhen CTL Testing Technology Co., Ltd.
Address of Test Firm .................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road,
Nanshan District, Shenzhen, China 518055
Test specification ........................ :
Standard ........................................ : FCC Part 15.249:Operation within the bands 920-928 MHz,
2400-2483.5 MHz, 5725-5850 MHz and 24.0 - 24.25 GHz.
TRF Originator .............................. : Shenzhen CTL Testing Technology Co., Ltd.
Master TRF ................................... : Dated 2011-01
Date of Receipt ............................ : Dec. 20, 2016
Date of Test Date ......................... : Dec. 21, 2016–Dec. 29, 2016
Data of Issue ................................ : Dec. 30, 2016
Result ........................................... : Pass
Shenzhen CTL Testing Technology Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
V1.0 Page 2 of 30 Report No.: CTL1610280303-WF
TEST REPORT
Test Report No. : CTL1610280303-WF Dec. 30, 2016
Date of issue
Equipment under Test : Portable Speaker
Model /Type : A026
Listed Models : MMA3628
Applicant : SHENZHEN AVWOO TECHNOLOGY CO., LTD.
Address : 3F, Block 2, Longtang Industrial Park, Liuyue
Community, Henggang Street, Longgang District,
Shenzhen, China
Manufacturer : SHENZHEN AVWOO TECHNOLOGY CO., LTD.
Address :
3F, Block 2, Longtang Industrial Park, Liuyue
Community, Henggang Street, Longgang District,
Shenzhen, China
Test result Pass *
* In the configuration tested, the EUT complied with the standards specified page 5.
The test report merely corresponds to the test sample.
It is not permitted to copy extracts of these test result without the written permission of the test laboratory.
V1.0 Page 3 of 30 Report No.: CTL1610280303-WF
** Modified History **
Revision Description Issued Data Report No. Remark
Version 1.0 Initial Test Report Release Dec. 30, 2016 CTL1610280303-WF Tracy Qi
V1.0 Page 4 of 30 Report No.: CTL1610280303-WF
Table of Contents Page
1.SUMMARY............................................................................................................................................................5
1.1.TESTSTANDARDS.....................................................................................................................................................5
1.2.TESTDESCRIPTION........................................................................................................................................................5
1.3.TESTFACILITY..............................................................................................................................................................6
1.4.STATEMENTOFTHEMEASUREMENTUNCERTAINTY...............................................................................................................6
2.GENERALINFORMATION.......................................................................................................................................7
2.1.ENVIRONMENTALCONDITIONS........................................................................................................................................7
2.2.GENERALDESCRIPTIONOFEUT......................................................................................................................................7
2.3.DESCRIPTIONOFTESTMODESANDTESTFREQUENCY..........................................................................................................7
2.4.EQUIPMENTSUSEDDURINGTHETEST..............................................................................................................................8
2.5.RELATEDSUBMITTAL(S)/GRANT(S).................................................................................................................................8
2.6.MODIFICATIONS...........................................................................................................................................................8
3.TESTCONDITIONSANDRESULTS...........................................................................................................................9
3.1.CONDUCTEDEMISSIONSTEST.........................................................................................................................................9
3.2.RADIATEDEMISSIONSANDBANDEDGE..........................................................................................................................12
3.3.OCCUPIEDBANDWIDTHMEASUREMENT.........................................................................................................................19
3.4.ANTENNAREQUIREMENT.............................................................................................................................................23
4.TESTSETUPPHOTOSOFTHEEUT........................................................................................................................24
5.EXTERNALANDINTERNALPHOTOSOFTHEEUT..................................................................................................25
V1.0 Page 5 of 30 Report No.: CTL1610280303-WF
1. SUMMARY
1.1. TEST STANDARDS
The tests were performed according to following standards:
FCC Rules Part 15.249: Operation within the bands 902 - 928 MHz, 2400 - 2483.5 MHz, 5725 - 5875
MHz, and 24.0 - 24.25 GHz.
ANSI C63.10:2013 : American National Standard for Testing Unlicensed Wireless Devices
ANSI C63.4: 2014: –American National Standard for Methods of Measurement of Radio-Noise
Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz
Range of 9 kHz to 40GHz
1.2. Test Description
FCC PART 15.249
FCC Part 15.249(a) Field Strength of Fundamental PASS
FCC Part 15.209 Spurious Emission PASS
FCC Part 15.209 Band edge PASS
FCC Part 15.215(c) 20dB bandwidth PASS
FCC Part 15.207 Conducted Emission PASS
FCC Part 15.203 Antenna Requirement PASS
V1.0 Page 6 of 30 Report No.: CTL1610280303-WF
1.3. Test Facility
1.3.1 Address of the test laboratory
Shenzhen CTL Testing Technology Co., Ltd.
Floor 1-A, Baisha Technology Park, No. 3011, Shahexi Road, Nanshan, Shenzhen 518055 China
There is one 3m semi-anechoic chamber and two line conducted labs for final test. The Test Sites
meet the requirements in documents ANSI C63.4 and CISPR 22/EN 55022 requirements.
1.3.2 Laboratory accreditation
The test facility is recognized, certified, or accredited by the following organizations:
IC Registration No.: 9618B
The 3m alternate test site of Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been
registered by Certification and Engineer Bureau of Industry Canada for the performance of with
Registration No.: 9618B on November 13, 2013.
FCC-Registration No.: 970318
Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been registered and fully described
in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the
FCC is maintained in our files. Registration 970318, December 19, 2013.
1.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that
there may be errors within the calibration limits of the equipment and facilities. The measurement
uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16 - 4
„Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
Uncertainty in EMC Measurements“ and is documented in the Shenzhen CTL Testing Technology Co.,
Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of
devices similar to that tested may result in additional deviation. The manufacturer has the sole
responsibility of continued compliance of the device.
Hereafter the best measurement capability for CTL laboratory is reported:
Test Range Measurement
Uncertainty Notes
Radiated Emission 30~1000MHz 4.10dB (1)
Radiated Emission Above 1GHz 4.32dB (1)
Conducted
Disturbance 0.15~30MHz 3.20dB (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2.
V1.0 Page 7 of 30 Report No.: CTL1610280303-WF
2. GENERAL INFORMATION
2.1. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Normal Temperature: 25°C
Relative Humidity: 55 %
Air Pressure: 101 kPa
2.2. General Description of EUT
Product Name: Portable Speaker
Model/Type reference: A026
Power supply: DC 3.7V from battery
Bluetooth
Version: Supported BT4.1
Modulation: GFSK, π/4DQPSK, 8DPSK
Operation frequency: 2402MHz~2480MHz
Channel number: 79
Channel separation: 1MHz
Antenna type: PCB Antenna
Antenna gain: 0dBi
Note:
For more details, please refer to the user’s manual of the EUT.
2.3. Description of Test Modes and Test Frequency
The Applicant provides communication tools software to control the EUT for staying in continuous
transmitting (Duty Cycle more than 98%) and receiving mode for testing .There are 79 channels
provided to the EUT and Channel 00/39/78 were selected for BT3.0 testing.
Operation Frequency BT3.0
Channel Frequency (MHz)
00 2402
01 2403
...
...
38 2440
39 2441
40 2442
...
...
77 2479
78 2480
V1.0 Page 8 of 30 Report No.: CTL1610280303-WF
2.4. Equipments Used during the Test
Test Equipment Manufacturer Model No. Serial No. Calibration
Date
Calibration
Due Date
LISN R&S ENV216
3560.6550.1
2 2016/06/02 2017/06/01
LISN R&S ESH2-Z5 860014/010 2016/06/02 2017/06/01
Bilog Antenna Sunol Sciences
Corp. JB1 A061713 2016/06/02 2017/06/01
EMI Test Receiver R&S ESCI 103710 2016/06/02 2017/06/01
Spectrum Analyzer Agilent E4407B MY41440676 2016/05/21 2017/05/20
Spectrum Analyzer Agilent N9020 US46220290 2016/01/17 2017/01/16
Controller EM Electronics
Controller EM
1000 N/A 2016/05/21 2017/05/20
Horn Antenna Sunol Sciences
Corp. DRH-118 A062013 2016/05/19 2017/05/18
Active Loop
Antenna
SCHWARZBE
CK FMZB1519 1519-037 2016/05/19 2017/05/18
Amplifier Agilent 8349B 3008A02306 2016/05/19 2017/05/18
Amplifier Agilent 8447D 2944A10176 2016/05/19 2017/05/18
Temperature/Humi
dity Meter Gangxing CTH-608 02 2016/05/20 2017/05/19
High-Pass Filter K&L 9SH10-2700/X1
2750-O/O N/A 2016/05/20 2017/05/19
High-Pass Filter K&L 41H10-1375/U1
2750-O/O N/A 2016/05/20 2017/05/19
Coaxial Cables HUBER+SUHN
ER
SUCOFLEX
104PEA-10M 10m 2016/06/02 2017/06/01
Coaxial Cables HUBER+SUHN
ER
SUCOFLEX
104PEA-3M 3m 2016/06/02 2017/06/01
Coaxial Cables HUBER+SUHN
ER
SUCOFLEX
104PEA-3M 3m 2016/06/02 2017/06/01
RF Cable Megalon RF-A303 N/A 2016/06/02 2017/06/01
The calibration interval was one year
2.5. Related Submittal(s) / Grant(s)
This submittal(s) (test report) is intended to comply with Section 15.249 of the FCC Part 15, Subpart C
Rules.
2.6. Modifications
No modifications were implemented to meet testing criteria.
V1.0 Page 9 of 30 Report No.: CTL1610280303-WF
3. TEST CONDITIONS AND RESULTS
3.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207
Frequency range (MHz)
Limit (dBuV)
Quasi-peak Average
0.15-0.5 66 to 56* 56 to 46*
0.5-5 56 46
5-30 60 50
* Decreases with the logarithm of the frequency.
TEST CONFIGURATION
TEST PROCEDURE
1. The equipment was set up as per the test configuration to simulate typical actual usage per the
user’s manual. The EUT is a tabletop system; a wooden table with a height of 0.8 meters is used
and is placed on the ground plane as per ANSI C63.10:2013.
2. Support equipment, if needed, was placed as per ANSI C63.10:2013.
3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10:2013.
4. If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied
power source and was grounded to the ground plane.
5. All support equipments received AC power from a second LISN, if any.
6. The EUT test program was started. Emissions were measured on each current carrying line of
the EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The
LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were
taken: one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load;
the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer /
Receiver.
7. Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.
8. During the above scans, the emissions were maximized by cable manipulation.
V1.0 Page 10 of 30 Report No.: CTL1610280303-WF
TEST RESULTS
Remark: All modes of GFSK, Pi/4 DQPSK, and 8DPSK were test at Low, Middle, and High
channel; only the worst result of 8DPSK High Channel was reported as below:
V1.0 Page 11 of 30 Report No.: CTL1610280303-WF
V1.0 Page 12 of 30 Report No.: CTL1610280303-WF
3.2. Radiated Emissions and Band Edge
Limit
According 15.249, the field strength of emissions from intentional radiators operated within
2400MHz-2483.5 MHz shall not exceed 94dBμV/m (50mV/m):
FCC PART 15.249(d) Emissions radiated outside of the specified frequency bands, except for
harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general
radiated emission limits in §15.209, whichever is the lesser attenuation.
In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also
comply with the radiated emission limits specified in §15.209(a)
Radiated emission limits
Frequency (MHz) Distance (Meters) Radiated (dBμV/m) Radiated (μV/m)
0.009-0.49 3 20log(2400/F(KHz))+40log(300/3) 2400/F(KHz)
0.49-1.705 3 20log(24000/F(KHz))+ 40log(30/3) 24000/F(KHz)
1.705-30 3 20log(30)+ 40log(30/3) 30
30-88 3 40.0 100
88-216 3 43.5 150
216-960 3 46.0 200
Above 960 3 54.0 500
TEST CONFIGURATION
(A) Radiated Emission Test Set-Up, Frequency Below 30MHz
(B) Radiated Emission Test Set-Up, Frequency below 1000MHz
V1.0 Page 13 of 30 Report No.: CTL1610280303-WF
(C) Radiated Emission Test Set-Up, Frequency above 1000MHz
Test Procedure
1. Below 1GHz measurement the EUT is placed on a turntable which is 0.8m above ground plane,
and above 1GHz measurement EUT was placed on a low permittivity and low loss tangent turn
table which is 1.5m above ground plane.
2. Maximum procedure was performed by raising the receiving antenna from 1m to 4m and rotating
the turn table from 0 to 360 to acquire the highest emissions from EUT
3. And also, each emission was to be maximized by changing the polarization of receiving antenna
both horizontal and vertical.
4. Repeat above procedures until all frequency measurements have been completed.
TEST RESULTS
Remark:
1. We measured Radiated Emission at GFSK, π/4 DQPSK and 8DPSK mode from 9 KHz to 25GHz
and recorded worst case at GFSK DH5 mode.
2. For below 1GHz testing recorded worst at GFSK DH5 low channel.
3. Radiated emission test from 9 KHz to 10th harmonic of fundamental was verified, and no
emission found except system noise floor in 9 KHz to 30MHz and not recorded in this report.
V1.0 Page 14 of 30 Report No.: CTL1610280303-WF
For 30MHz-1GHz
Horizontal
Vertical
Note:
1. Margin = Limit - level
V1.0 Page 15 of 30 Report No.: CTL1610280303-WF
For 1GHz to 25GHz
NoteGFSK, Pi/4 DQPSK and 8DPSK all have been tested, only worse case GFSK is reported.
GFSK Mode (above 1GHz)
Frequency(MHz): 2402 Polarity: HORIZONTAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
4804.00 55.24 PK 74 18.76 50.73 33.49 6.91 35.89 4.51
4804.00 47.52 AV 54 6.48 43.01 33.49 6.91 35.89 4.51
5050.25 45.62 PK 74 28.38 38.65 34.16 7.06 34.25 6.97
5050.25 -- AV 54 -- -- -- -- -- --
7206.00 48.73 PK 74 25.27 37.62 36.95 9.18 35.03 11.11
7206.00 -- AV 54 -- -- -- -- -- --
Frequency(MHz): 2402 Polarity: VERTICAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
4804.00 55.34 PK 74 18.66 50.83 33.49 6.91 35.89 4.51
4804.00 47.45 AV 54 6.55 42.94 33.49 6.91 35.89 4.51
5050.25 45.69 PK 74 28.31 38.72 34.16 7.06 34.25 6.97
5050.25 -- AV 54 -- -- -- -- -- --
7206.00 48.80 PK 74 25.2 37.69 36.95 9.18 35.03 11.11
7206.00 -- AV 54 -- -- -- -- -- --
Frequency(MHz): 2441 Polarity: HORIZONTAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
4882.00 56.11 PK 74 17.89 51.46 33.60 6.95 35.90 4.65
4882.00 48.50 AV 54 5.5 43.85 33.60 6.95 35.90 4.65
5315.25 46.12 PK 74 27.88 38.60 34.66 7.21 34.34 7.52
5315.25 -- AV 54 -- -- -- -- -- --
7323.00 48.75 PK 74 25.25 37.05 37.46 9.23 35.00 11.70
7323.00 -- AV 54 -- -- -- -- -- --
Frequency(MHz): 2441 Polarity: VERTICAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
4882.00 56.24 PK 74 17.76 51.59 33.60 6.95 35.90 4.65
4882.00 48.98 AV 54 5.02 44.33 33.60 6.95 35.90 4.65
5315.25 45.22 PK 74 28.78 37.70 34.66 7.21 34.34 7.52
5315.25 -- AV 54 -- -- -- -- -- --
7323.00 49.15 PK 74 24.85 37.45 37.46 9.23 35.00 11.70
7323.00 -- AV 54 -- -- -- -- -- --
V1.0 Page 16 of 30 Report No.: CTL1610280303-WF
Frequency(MHz): 2480 Polarity: HORIZONTAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
4960.00 56.85 PK 74 17.15 51.93 33.84 7.00 35.92 4.92
4960.00 48.68 AV 54 5.32 43.76 33.84 7.00 35.92 4.92
6025.50 46.44 PK 74 27.56 38.27 35.14 7.63 34.60 8.17
6025.50 -- AV 54 -- -- -- -- -- --
7440.00 48.86 PK 74 25.14 36.91 37.64 9.28 34.97 11.95
7440.00 -- AV 54 -- -- -- -- -- --
Frequency(MHz): 2480 Polarity: VERTICAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
4960.00 56.91 PK 74 17.09 51.99 33.84 7.00 35.92 4.92
4960.00 49.15 AV 54 4.85 44.23 33.84 7.00 35.92 4.92
6025.50 45.77 PK 74 28.23 37.60 35.14 7.63 34.60 8.17
6025.50 -- AV 54 -- -- -- -- -- --
7440.00 49.52 PK 74 24.48 37.57 37.64 9.28 34.97 11.95
7440.00 -- AV 54 -- -- -- -- -- --
REMARKS:
1. Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
3. Margin value = Limit value- Emission level.
4. -- Mean the PK detector measured value is below average limit.
5. The other emission levels were very low against the limit.
6. RBW1MHz VBW3MHz Peak detector is for PK value; RBW 1MHz VBW10Hz Peak
detector is for AV value.
V1.0 Page 17 of 30 Report No.: CTL1610280303-WF
Results of Band Edges Test (Radiated)
Note
GFSK, Pi/4 DQPSK and 8DPSK all have been tested, only worse case GFSK is reported.
Frequency(MHz): 2402 Polarity: HORIZONTAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
2402.00 96.15 PK 114 17.85 62.75 28.78 4.61 0.00 33.40
2402.00 90.22 AV 94 3.78 56.82 28.78 4.61 0.00 33.40
2365.75 45.30 PK 74 28.7 12.16 28.57 4.57 0.00 33.14
2365.75 -- AV 54 -- -- -- -- -- --
2390.00 49.64 PK 74 24.36 16.32 28.72 4.60 0.00 33.32
2390.00 -- AV 54 -- -- -- -- -- --
2400.00 51.47 PK 74 22.53 18.08 28.78 4.61 0.00 33.39
2400.00 -- AV 54 -- -- -- -- -- --
Frequency(MHz): 2402 Polarity: VERTICAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
2402.00 96.24 PK 114 17.76 62.84 28.78 4.61 0.00 33.40
2402.00 90.31 AV 94 3.69 56.91 28.78 4.61 0.00 33.40
2365.75 45.54 PK 74 28.46 12.40 28.57 4.57 0.00 33.14
2365.75 -- AV 54 -- -- -- -- -- --
2390.00 50.04 PK 74 23.96 16.72 28.72 4.60 0.00 33.32
2390.00 -- AV 54 -- -- -- -- -- --
2400.00 51.87 PK 74 22.13 18.48 28.78 4.61 0.00 33.39
2400.00 -- AV 54 -- -- -- -- -- --
Frequency(MHz): 2480 Polarity: HORIZONTAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
2480.00 97.15 PK 114 16.85 63.53 28.92 4.70 0.00 33.62
2480.00 90.75 AV 94 3.25 57.13 28.92 4.70 0.00 33.62
2483.50 51.24 PK 74 22.76 17.61 28.93 4.70 0.00 33.63
2483.50 -- AV 54 -- -- -- -- -- --
2485.50 50.11 PK 74 23.89 16.47 28.93 4.70 0.00 33.64
2485.50 -- AV 54 -- -- -- -- -- --
2500.00 41.50 PK 74 32.5 7.82 28.96 4.72 0.00 33.68
2500.00 -- AV 54 -- -- -- -- -- --
V1.0 Page 18 of 30 Report No.: CTL1610280303-WF
Frequency(MHz): 2480 Polarity: VERTICAL
Frequency
(MHz)
Emission
Level
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Raw
Value
(dBuV)
Antenna
Factor
(dB/m)
Cable
Factor
(dB)
Pre-amplifier
(dB)
Correction
Factor
(dB/m)
2480.00 97.33 PK 114 17.46 62.92 28.92 4.70 0.00 33.62
2480.00 90.84 AV 94 3.22 57.16 28.92 4.70 0.00 33.62
2483.50 51.65 PK 74 24.75 15.62 28.93 4.70 0.00 33.63
2483.50 -- AV 54 -- -- -- -- -- --
2485.50 50.24 PK 74 29.37 10.97 28.95 4.71 0.00 33.66
2485.50 -- AV 54 -- -- -- -- -- --
2500.00 41.78 PK 74 33.5 6.82 28.96 4.72 0.00 33.68
2500.00 -- AV 54 -- -- -- -- -- --
REMARKS:
1. Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
3. Margin value = Limit value- Emission level.
4. -- Mean the PK detector measured value is below average limit.
5. The other emission levels were very low against the limit.
6. RBW1MHz VBW3MHz Peak detector is for PK value; RBW 1MHz VBW10Hz Peak
detector is for AV value.
7. For fundamental frequency, RBW 3MHz VBW 3MHz Peak detector is for PK Value; RMS
detector is for AV value.
V1.0 Page 19 of 30 Report No.: CTL1610280303-WF
3.3. Occupied Bandwidth Measurement
Limit
N/A
Test Configuration
EUT
SPECTRUM
ANALYZER
Test Procedure
The transmitter output was connected to the spectrum analyzer through an attenuator. The bandwidth
of the fundamental frequency was measured by spectrum analyzer with 30 KHz RBW and 100 KHz
VBW.
The 20dB bandwidth is defined as the total spectrum the power of which is higher than peak power
minus 20dB.
Test Results
BT3.0
Modulation Channel 99% OBW
(MHz)
20dB bandwidth
(MHz) Result
GFSK
CH00 0.903 0.941
Pass
CH39 0.910 0.946
CH78 0.911 0.946
π/4DQPSK
CH00 1.231 1.179
CH39 1.231 1.181
CH78 1.223 1.179
8DPSK
CH00 1.230 1.191
CH39 1.227 1.190
CH78 1.231 1.189
Test plot as follows:
V1.0 Page 20 of 30 Report No.: CTL1610280303-WF
BT3.0
GFSK Modulation
CH00
CH39
CH78
V1.0 Page 21 of 30 Report No.: CTL1610280303-WF
π/4 DQPSK Modulation
CH00
CH39
CH78
V1.0 Page 22 of 30 Report No.: CTL1610280303-WF
8DPSK Modulation
CH00
CH39
CH78
V1.0 Page 23 of 30 Report No.: CTL1610280303-WF
3.4. Antenna Requirement
Standard Applicable
For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
designed to ensure that no antenna other than that furnished by the responsible party shall be used
with the device.
Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.
Antenna Connected Construction
The antenna used in this product is an PCB Antenna, The directional gains of antenna used for
transmitting is 0dBi.
Antenna
V1.0 Page 24 of 30 Report No.: CTL1610280303-WF
4. Test Setup Photos of the EUT
V1.0 Page 25 of 30 Report No.: CTL1610280303-WF
5. External and Internal Photos of the EUT
External Photos of EUT
V1.0 Page 26 of 30 Report No.: CTL1610280303-WF
V1.0 Page 27 of 30 Report No.: CTL1610280303-WF
V1.0 Page 28 of 30 Report No.: CTL1610280303-WF
Internal Photos of EUT
V1.0 Page 29 of 30 Report No.: CTL1610280303-WF
antenna
V1.0 Page 30 of 30 Report No.: CTL1610280303-WF
********************** End of Report **********************
Download: Portable Speaker Test Report - CTL1610280303-WF FCC15.249 BT3.0 SHENZHEN AVWOO TECHNOLOGY CO., LTD
Mirror Download [FCC.gov]Portable Speaker Test Report - CTL1610280303-WF FCC15.249 BT3.0 SHENZHEN AVWOO TECHNOLOGY CO., LTD
Document ID3254129
Application IDd9s3EDHZB3LROtg8gkICug==
Document Description14_A026 TestRpt
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize215.46kB (2693282 bits)
Date Submitted2017-01-10 00:00:00
Date Available2017-01-10 00:00:00
Creation Date2017-01-09 16:54:06
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-01-09 16:54:06
Document TitleMicrosoft Word - CTL1610280303-WF FCC15.249 BT3.0
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Facebook Twitter Google+ RSS © FCCID.io 2017