Mobile phone Test Report HD 271 S1 Azumi S.A

Azumi S.A Mobile phone

See More Details For FCC ID: QRP-AZUMIL3GAV2
Purchase on Amazon: Mobile phone
Download: Mobile phone Test Report HD 271 S1 Azumi S.A
Document DescriptionTest report
Document TypeTest Report
Date Submitted2017-02-16 00:00:00
Producing SoftwareMicrosoft Word 2010
Document TitleHD 271 S1

Document

Trouble Loading? Try Mobile phone Test Report HD 271 S1 Azumi S.A Downloading this document.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Report No:CCISE161205303
Authorized Signature:
Bruce Zhang
Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.
1 Cover Page FCC REPORT
Applicant:
AZUMI S.A
Address of Applicant:
AvenidaAquilino de la Guardia con Calle 47, PH Ocean Plaza,
Piso 16 of. 16-01, Marbella, Ciudad de Panamá City, Rep.
Panamá
Equipment Under Test (EUT)
Product Name:
Mobile phone
Model No.:
L3GA V2
Trade mark:
AZUMI
FCC ID:
QRP-AZUMIL3GAV2
Applicablestandards:
FCC CFR Title 47 Part 15 Subpart B
Date of sample receipt:
26 Dec., 2016
Date of Test:
27 Dec., 2016 to 20 Jan., 2017
Date of report issued:
20 Jan., 2017
Test Result:
Pass *
*In the configuration tested, the EUT complied with the standards specified above.
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 2 of 18
2 Version
Version No.
Date
Description
00
20 Jan., 2017
Original
Tested by:
Date:
20 Jan., 2017
Reviewed by:
Date:
20 Jan., 2017
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 3 of 18
3 Contents
Page
1 COVER PAGE ....................................................................................................................................................... 1
2 VERSION ............................................................................................................................................................... 2
3 CONTENTS ........................................................................................................................................................... 3
4 TEST SUMMARY .................................................................................................................................................. 4
5 GENERAL INFORMATION .................................................................................................................................. 5
5.1 CLIENT INFORMATION ...................................................................................................................................................... 5
5.2 GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
5.3 TEST MODE .................................................................................................................................................................... 5
5.4 MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
5.5 DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
5.6 LABORATORY FACILITY ...................................................................................................................................................... 6
5.7 LABORATORY LOCATION ................................................................................................................................................... 6
5.8 TEST INSTRUMENTS LIST .................................................................................................................................................... 7
6 TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
6.1 CONDUCTED EMISSION ..................................................................................................................................................... 8
6.2 RADIATED EMISSION ...................................................................................................................................................... 11
7 TEST SETUP PHOTO ........................................................................................................................................ 17
8 EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 4 of 18
4 Test Summary
Test Item
Section in CFR 47
Result
Conducted Emission
Part15.107
Pass
Radiated Emission
Part15.109
Pass
Pass: The EUT complies with the essential requirements in the standard.
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 5 of 18
5 General Information
5.1 Client Information
Applicant:
AZUMI S.A
Address of Applicant:
AvenidaAquilino de la Guardia con Calle 47, PH Ocean Plaza, Piso 16
of. 16-01, Marbella, Ciudad de Panamá City, Rep. Panamá
Manufacturer
AZUMI HK LTD
Address of Manufacturer:
LAT/RM 18 BLK 1 14/F GOLDEN INDUSTRIAL BUILDING 16-26 KWAI
TAK STREET KWAI CHUNG,HK
5.2 General Description of E.U.T.
Product Name:
Mobile phone
Model No.:
L3GA V2
Power supply:
Rechargeable Li-ion Battery DC3.7V-800mAh
AC adapter :
Model: TPA-90C050050UU
Input: AC100-240V 50/60Hz 0.1A
Output: DC 5.0V, 500mA
5.3 Test Mode
Operating mode
Detail description
PC mode
Keep the EUT in Downloading mode(Worst case)
Charging+Recording mode
Keep the EUT in Charging+Recording mode
Charging+Playing mode
Keep the EUT in Charging+Playing mode
FM mode
Keep the EUT in FM receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-
case are shown in Test Results of the following pages.
5.4 Measurement Uncertainty
Items
Expanded Uncertainty (Confidence of 95%)
Conducted Emission (9kHz ~ 30MHz)
2.14 dB (k=2)
Radiated Emission (9kHz ~ 30MHz)
4.24 dB (k=2)
Radiated Emission (30MHz ~ 1000MHz)
4.35 dB (k=2)
Radiated Emission (1GHz ~ 18GHz)
4.44 dB (k=2)
Radiated Emission (18GHz ~ 26.5GHz)
4.56 dB (k=2)
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 6 of 18
5.5 Description of Support Units
Manufacturer
Description
Model
Serial Number
FCC ID/DoC
DELL
PC
OPTIPLEX745
N/A
DoC
DELL
MONITOR
E178FPC
N/A
DoC
DELL
KEYBOARD
SK-8115
N/A
DoC
DELL
MOUSE
MOC5UO
N/A
DoC
HP
Printer
CB495A
05257893
DoC
5.6 Laboratory Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC - Registration No.: 817957
Shenzhen Zhongjian Nanfang Testing Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
from the FCC is maintained in out files. Registration 817957, February 27, 2012.
IC - Registration No.: 10106A-1
The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
with Registration No.: 10106A-1.
CNAS - Registration No.: CNAS L6048
Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
Requirements for the Competence of Testing and Calibration laboratories for the competence of
testing.The Registration No. is CNAS L6048.
5.7 Laboratory Location
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Address: No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District,Shenzhen, Guangdong,China
Tel: +86-755-23118282
Fax: +86-755-23116366
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 7 of 18
5.8 Test Instruments list
Radiated Emission:
Item
Test Equipment
Manufacturer
Model No.
Inventory
No.
Cal. Date
(mm-dd-yy)
Cal. Due date
(mm-dd-yy)
1
3m SAC
SAEMC
9(L)*6(W)* 6(H)
CCIS0001
08-23-2014
08-22-2017
2
BiConiLog Antenna
SCHWARZBECK
VULB9163
CCIS0005
03-25-2016
03-25-2017
3
Horn Antenna
SCHWARZBECK
BBHA9120D
CCIS0006
03-25-2016
03-25-2017
4
Pre-amplifier
(10kHz-1.3GHz)
HP
8447D
CCIS0003
04-01-2016
03-31-2017
5
Pre-amplifier
(1GHz-18GHz)
Compliance Direction
Systems Inc.
PAP-1G18
CCIS0011
04-01-2016
03-31-2017
6
Spectrum analyzer
9k-30GHz
Rohde & Schwarz
FSP30
CCIS0023
03-28-2016
03-28-2017
7
EMI Test Receiver
Rohde & Schwarz
ESRP7
CCIS0167
03-28-2016
03-28-2017
8
EMI Test Software
AUDIX
E3
N/A
N/A
N/A
9
Coaxial Cable
N/A
N/A
CCIS0018
04-01-2016
03-31-2017
10
Coaxial Cable
N/A
N/A
CCIS0020
04-01-2016
03-31-2017
Conducted Emission:
Item
Test Equipment
Manufacturer
Model No.
Inventory
No.
Cal.Date
(mm-dd-yy)
Cal.Due date
(mm-dd-yy)
1
Shielding Room
ZhongShuo Electron
11.0(L)x4.0(W)x3.0(H)
CCIS0061
08-23-2014
08-22-2017
2
EMI Test Receiver
Rohde & Schwarz
ESCI
CCIS0002
03-24-2016
03-24-2017
3
LISN
CHASE
MN2050D
CCIS0074
03-26-2016
03-26-2017
4
Coaxial Cable
CCIS
N/A
CCIS0086
04-01-2016
03-31-2017
5
EMI Test Software
AUDIX
E3
N/A
N/A
N/A
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 8 of 18
6 Test results andMeasurement Data
6.1 Conducted Emission
Test Requirement:
FCC Part15 B Section 15.107
Test Method:
ANSI C63.4:2014
Test Frequency Range:
150kHz to 30MHz
Class / Severity: Class B
Class B
Receiver setup:
RBW=9kHz, VBW=30kHz
Limit:
Frequency range (MHz)
Limit (dBµV)
Quasi-peak
Average
0.15-0.5
66 to 56*
56 to 46*
0.5-5
56
46
0.5-30
60
50
* Decreases with the logarithm of the frequency.
Test setup:
Test procedure
1. The E.U.T and simulators are connected to the main power through a
line impedance stabilization network(L.I.S.N.). The provide a
50ohm/50uH coupling impedance for the measuring equipment.
2. The peripheral devices are also connected to the main power through
a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
termination. (Please refers to the block diagram of the test setup and
photographs).
3. Both sides of A.C. line are checked for maximum conducted
interference. In order to find the maximum emission, the relative
positions of equipment and all of the interface cables must be changed
according to ANSI C63.4: 2014on conducted measurement.
Test environment:
Temp.:
23C
Humid.:
56%
Press.:
101kPa
Test Instruments:
Refer to section 5.7 for details
Test mode:
Refer to section 5.3 for details
Test results:
Pass
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 9 of 18
Measurement data:
Line:
Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 10 of 18
Neutral:
Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 11 of 18
6.2 Radiated Emission
Test Requirement:
FCC Part15 B Section 15.109
Test Method:
ANSI C63.4:2014
Test Frequency Range:
30MHz to 26000MHz
Test site:
Measurement Distance: 3m (Semi-Anechoic Chamber)
Receiver setup:
Frequency
Detector
RBW
VBW
Remark
30MHz-1GHz
Quasi-peak
120kHz
300kHz
Quasi-peak Value
Above 1GHz
Peak
1MHz
3MHz
Peak Value
RMS
1MHz
3MHz
Average Value
Limit:
Frequency
Limit (dBuV/m @3m)
Remark
30MHz-88MHz
40.0
Quasi-peak Value
88MHz-216MHz
43.5
Quasi-peak Value
216MHz-960MHz
46.0
Quasi-peak Value
960MHz-1GHz
54.0
Quasi-peak Value
Above 1GHz
54.0
Average Value
74.0
Peak Value
Test setup:
Below 1GHz
Above 1GHz
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 12 of 18
Test Procedure:
1. The EUT was placed on the top of a rotating table 0.8 meters above the
groundat a 3 meter semi-anechoic camber. The table was rotated 360
degrees todetermine the position of the highest radiation.
2. The EUT was set 3 meters away from the interference-receiving
antenna, whichwas mounted on the top of a variable-height antenna
tower.
3. The antenna height is varied from one meter to four meters above the
ground to determine the maximum value of the field strength. Both
horizontal and vertical polarizations of the antenna are set to make the
measurement.
4. For each suspected emission, the EUT was arranged to its worst case
and thenthe antenna was tuned to heights from 1 meter to 4 meters and
the rotatabletable was turned from 0 degrees to 360 degrees to find the
maximum reading.
5. The test-receiver system was set to Peak Detect Function and
SpecifiedBandwidth with Maximum Hold Mode.
6. If the emission level of the EUT in peak mode was 10dB lower than the
limit specified, then testing could be stopped and the peak values of the
EUT would be reported. Otherwise the emissions that did not have 10dB
margin would be re-tested one by one using peak, quasi-peak or
average method as specified and then reported in a data sheet.
Test environment:
Temp.:
25C
Humid.:
55%
Press.:
101kPa
Test Instruments:
Refer to section 5.7 for details
Test mode:
Refer to section 5.3 for details
Test results:
Passed
Remark:
All of theobserved value above 6GHz ware theniose floor , which were no
recorded
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 13 of 18
Measurement Data:
Below 1GHz
Horizontal:
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 14 of 18
Vertical:
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 15 of 18
Above 1GHz
Horizontal:
Report No: CCISE161205303
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1612053
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366 Page 16 of 18
Vertical:
Download: Mobile phone Test Report HD 271 S1 Azumi S.A

Document ID3285460
Application IdX/gmCtr20IfEjmaO3lorQQ==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize1630994
Date Submitted2017-02-16 00:00:00
Date Available2017-02-16 00:00:00
Creation Date2017-02-06 17:20:04
Producing SoftwareMicrosoft Word 2010
Document Lastmod2017-02-06 17:20:17
Document TitleHD 271 S1
Document CreatorMicrosoft Word 2010
Document Author: LAB02

Facebook Twitter Google+ RSS © FCCID.io 2017