FCC ID 2A23ZDATAHUB

WiFi Router

by PredictWind Ltd

Grantee Code: 2A23Z   Product Code: DATAHUB
Latest application date: 2021-10-24

FCC ID Device Details

FCC ID2A23ZDATAHUB
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A23Z
Product CodeDATAHUB
Applicant BusinessPredictWind Ltd 🇳🇿
Related Domains predictwind.com
Equipment ClassWiFi Router
Test FirmWorldwide Testing Services (Taiwan) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2021-10-24
2412-2462 MHzOriginal Equipment2021-10-24

Exhibits

DocumentTypeAvailableFile
Users Manual Part 1of2Users Manual2021-10-24PDF 4.4 MB
Users Manual Part 2of2Users Manual2021-10-24PDF 3.4 MB
Internal PhotosInternal Photos2021-10-24PDF 466.8 KB
External PhotosExternal Photos2021-10-24PDF 623.7 KB
ID Label and LocationID Label/Location Info2021-10-24PDF 203.6 KB
Test Setup PhotosTest Setup Photos2021-10-24PDF 922 KB
Test ReportTest Report2021-10-24PDF 3.8 MB
Test ReportTest Report2021-10-24PDF 2.7 MB
Authorization LetterCover Letter(s)2021-10-24PDF 212.6 KB
Confidentiality RequestCover Letter(s)2021-10-24PDF 275.9 KB
MPE PredictionRF Exposure Info2021-10-24PDF 546.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 123.3 KB
Schematics Metadata onlySchematicsPDF 396.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 121.1 KB
Antenna Spec Metadata onlyParts List/Tune Up InfoPDF 124.8 KB

Application Information

Application IDfFusDykNmn9j/Tv4ED3Ntw==
Final Action Date2021-10-24
Application PurposeOriginal Equipment
Applicant FRN0031334063
ModelDATAHUB
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionWiFi Router
Responsible PartyJon Bilger, Managing Director, jonbilger@predictwind.com , +64272113111
Technical ContactDanny Sung, Worldwide Testing Services (Taiwan) Co., Ltd., danny@wts-lab.com , +886266068877
Test FirmDanny Sung, Worldwide Testing Services (Taiwan) Co., Ltd., danny@wts-lab.com , 886-2-6606-8877
TCB EmailJoergKusig@eurofins.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration and for indoor operations only as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz, 40 MHz, and 80 MHz bandwidth modes.

Applications

Application IDDatePurpose
fFusDykNmn9j/Tv4ED3Ntw==2021-10-24Original Equipment
WUBdtGKCJPI8WVWBj3h1xw==2021-10-24Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.051115CCC, MO
2422-2452 MHz0.026815CCC, MO
5180-5240 MHz0.029415ECC, MO
5190-5230 MHz0.002115ECC, MO
5210 MHz0.009115ECC, MO
5745-5825 MHz0.024815ECC, MO
5755-5795 MHz0.024915ECC, MO
5775 MHz0.016915ECC, MO

Grants

TCB Grant - Application WUBdtGKCJPI8WVWBj3h1xw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 10/24/2021

Application Dated: 10/24/2021
PredictWind Ltd
198 Riverside Avenue
Point England
Auckland, 1072
New Zealand
 
Attention: Jon Bilger , Managing Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A23ZDATAHUB
Name of Grantee:  PredictWind Ltd
Equipment Class: Digital Transmission System
Notes: WiFi Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.0511  
CC MO 15C 2422.0  -  2452.0 0.0268  

Output power listed is conducted. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration and for indoor operations only as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz, and 40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application WUBdtGKCJPI8WVWBj3h1xw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PredictWind Ltd
198 Riverside Avenue Point England
Auckland, 1072
New Zealand
  Date of Grant: 10/24/2021

Application Dated: 10/24/2021
 
Attention: Jon Bilger , Managing Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A23ZDATAHUB
Name of Grantee:  PredictWind Ltd
Equipment Class: Digital Transmission System
Notes: WiFi Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.0511  
CC MO 15C 2422.0  -  2452.0 0.0268  

Output power listed is conducted. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration and for indoor operations only as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz, and 40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application fFusDykNmn9j/Tv4ED3Ntw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 10/24/2021

Application Dated: 10/24/2021
PredictWind Ltd
198 Riverside Avenue
Point England
Auckland, 1072
New Zealand
 
Attention: Jon Bilger , Managing Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A23ZDATAHUB
Name of Grantee:  PredictWind Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: WiFi Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0294  
CC MO 15E 5190.0  -  5230.0 0.0021  
CC MO 15E 5210.0  -  5210.0 0.0091  
CC MO 15E 5745.0  -  5825.0 0.0248  
CC MO 15E 5755.0  -  5795.0 0.0249  
CC MO 15E 5775.0  -  5775.0 0.0169  

Output power listed is conducted. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration and for indoor operations only as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz, 40 MHz, and 80 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application fFusDykNmn9j/Tv4ED3Ntw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PredictWind Ltd
198 Riverside Avenue Point England
Auckland, 1072
New Zealand
  Date of Grant: 10/24/2021

Application Dated: 10/24/2021
 
Attention: Jon Bilger , Managing Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A23ZDATAHUB
Name of Grantee:  PredictWind Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: WiFi Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0294  
CC MO 15E 5190.0  -  5230.0 0.0021  
CC MO 15E 5210.0  -  5210.0 0.0091  
CC MO 15E 5745.0  -  5825.0 0.0248  
CC MO 15E 5755.0  -  5795.0 0.0249  
CC MO 15E 5775.0  -  5775.0 0.0169  

Output power listed is conducted. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration and for indoor operations only as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz, 40 MHz, and 80 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: