FCC ID 2A258-OP100P02

Wearable biosignals monitor

by Acurable Limited

Grantee Code: 2A258   Product Code: OP100P02
Latest application date: 2025-05-20

FCC ID Device Details

FCC ID2A258-OP100P02
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A258
Product CodeOP100P02
Applicant BusinessAcurable Limited 🇬🇧
Related Domains acurable.com
Equipment ClassWearable biosignals monitor
Test FirmDEKRA Certification, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2025-05-20

Exhibits

DocumentTypeAvailableFile
0-ACURABLE_USERMANUAL_US_Ox200_1.4.1Users Manual2025-11-16PDF 5.2 MB
Photos - Internal - v2.2Internal Photos2025-11-16PDF 3.4 MB
3-Photographs_Externals -OxiPebble-100-P02External Photos2025-11-16PDF 2.1 MB
1-Product_Label_Design_OxiPebbleID Label/Location Info2025-05-20PDF 307.6 KB
15-78661RRF001_PhotographsTest Setup Photos2025-11-16PDF 1.4 MB
17-78661REM.001_PhotographsTest Setup Photos2025-11-16PDF 676.9 KB
12-Antenna-2450AT07A0100001TTest Report2025-05-20PDF 561.7 KB
14-78661RRF001A2sTest Report2025-05-20PDF 2.3 MB
16-78661REM001sTest Report2025-05-20PDF 1.9 MB
78661REM001sTest Report2025-05-20PDF 1.9 MB
7-FCC US Agent Attestation_signedAttestation Statements2025-05-20PDF 201.2 KB
8-FCB045_00 Certifications concerning covered equipmentAttestation Statements2025-05-20PDF 158.8 KB
10-FCB011_02 FCC Agent letterCover Letter(s)2025-05-20PDF 168.9 KB
9-FCB012_05 FCC Confidentiality RequestCover Letter(s)2025-05-20PDF 211.5 KB
18-78661RAN.001s - RF ExpRF Exposure Info2025-05-20PDF 480.2 KB
5-OxiPebble Electrical Block Diagram_v5 Metadata onlyBlock DiagramPDF 1.9 MB
13-acupebble-oximeter-board_P02-schematic Metadata onlySchematicsPDF 563.4 KB
Schematic Metadata onlySchematicsPDF 563.4 KB
4-OxiPebble Technical Specification_1.2 - v2 Metadata onlyOperational DescriptionPDF 519.5 KB
6-nRF52832_PS_v1.4 Metadata onlyOperational DescriptionPDF 4.9 MB

Application Information

Application IDeYqAKfGCO0P8mYO9gV+Scg==
Final Action Date2025-05-20
Application PurposeOriginal Equipment
Applicant FRN0031355084
ModelOP100P02
Equipment ClassJAB - Part 15 Class B Digital Device
Device DescriptionWearable biosignals monitor
Responsible PartyAnas Imtiaz, Dr, anas@acurable.com , +44208 1917590
AgentMarta Marta Marta, Dekra Testing and Certification SAU, marta.arrabal@dekra.com
Test FirmJose Fernandez, DEKRA Certification, Inc., josemaria.fernandez@dekra.com , 703-657-2004
TCB Emailadmin.rcb.es@dekra.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/16/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
eYqAKfGCO0P8mYO9gV+Scg==2025-05-20Original Equipment
XBfOEd7yeUDHfUjBhIhP7g==2025-05-20Original Equipment

Equipment Authorization

FrequencyOutputGrant Notes
CC
2402-2480 MHz0.0016000CC

Grants

TCB Grant - Application XBfOEd7yeUDHfUjBhIhP7g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DEKRA Testing and Certification, S.A.U.
Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6
Campanillas - Malaga, 29590
Spain
Date of Grant: 05/20/2025

Application Dated: 05/20/2025
Acurable Limited
2 Leman Street
London, E1W 9US
United Kingdom
 
Attention: Anas Imtiaz , Dr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A258-OP100P02
Name of Grantee:  Acurable Limited
Equipment Class: Digital Transmission System
Notes: Wearable biosignals monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0016  

Outpout power is conducted .

This device meets the SAR Test Exclusion threshold specified in KDB447498 and sincethen, it is authorized for portable operation.

Multi-transmitter, supporting simultaneous transmission configurations, have not beenevaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f),§15.31(h) and §15.31(k) composite system and §2.1 product terms and concepts.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application eYqAKfGCO0P8mYO9gV+Scg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DEKRA Testing and Certification, S.A.U.
Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6
Campanillas - Malaga, 29590
Spain
Date of Grant: 05/20/2025

Application Dated: 05/20/2025
Acurable Limited
2 Leman Street
London, E1W 9US
United Kingdom
 
Attention: Anas Imtiaz , Dr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A258-OP100P02
Name of Grantee:  Acurable Limited
Equipment Class: Part 15 Class B Digital Device
Notes: Wearable biosignals monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.