FCC ID 2A289BRTM36
400 MHz Digital TETRA Repeater
by Eviden
Grantee Code: 2A289 Product Code: BRTM36
Latest application date: 2025-05-20
FCC ID Device Details
| FCC ID | 2A289BRTM36 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A289 |
| Product Code | BRTM36 |
| Applicant Business | Eviden 🇦🇹 |
| Related Domains | |
| Equipment Class | 400 MHz Digital TETRA Repeater |
| Test Firm | IIA LAB SERVICES, LLC |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 450-452.575 MHz | Original Equipment | 2025-05-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2025-05-20 | PDF 599.9 KB |
| Booster Label Sample | ID Label/Location Info | 2025-05-20 | PDF 1.3 MB |
| Label Location | ID Label/Location Info | 2025-05-20 | PDF 3.4 MB |
| Label Sample | ID Label/Location Info | 2025-05-20 | PDF 1.4 MB |
| TSUP | Test Setup Photos | 2025-05-20 | PDF 1.3 MB |
| Test Report | Test Report | 2025-05-20 | PDF 1.3 MB |
| Att Statements 2.911(d)(5)(7) | Attestation Statements | 2025-05-20 | PDF 293.9 KB |
| Att Statements 2.911(d)(5)(i)&(ii) | Attestation Statements | 2025-05-20 | PDF 110.2 KB |
| Booster Attestation | Cover Letter(s) | 2025-05-20 | PDF 171.3 KB |
| KDB Attestation | Attestation Statements | 2025-05-20 | PDF 183.7 KB |
| Tuning Attestation | Cover Letter(s) | 2025-05-20 | PDF 182.4 KB |
| Confidentiality Letter | Cover Letter(s) | 2025-05-20 | PDF 236.3 KB |
| RF Exposure MPE | RF Exposure Info | 2025-05-20 | PDF 322.7 KB |
| User Manual Metadata only | Users Manual | PDF 4.8 MB | |
| Internal Photos Metadata only | Internal Photos | PDF 2.2 MB | |
| Block Diagram Metadata only | Block Diagram | PDF 414 KB | |
| Schematics Downlink Metadata only | Schematics | PDF 783.4 KB | |
| Schematics Uplink Metadata only | Schematics | PDF 783.7 KB | |
| Circuit Description Metadata only | Operational Description | PDF 367.1 KB | |
| BOM BRTL35-EA-03-V03 center Metadata only | Parts List/Tune Up Info | PDF 843.6 KB | |
| BOM BUFI12-EK-01 Metadata only | Parts List/Tune Up Info | PDF 4.2 MB | |
| BOM BUFI12-EK-02 Metadata only | Parts List/Tune Up Info | PDF 1.9 MB | |
| BOM Digital Filter Metadata only | Parts List/Tune Up Info | PDF 1.3 MB | |
| BOM downlink Metadata only | Parts List/Tune Up Info | PDF 1.1 MB | |
| BOM secondary power supply Metadata only | Parts List/Tune Up Info | PDF 305.3 KB | |
| BOM uplink Metadata only | Parts List/Tune Up Info | PDF 1.2 MB | |
| Tune-up Procedure Metadata only | Parts List/Tune Up Info | PDF 280.9 KB |
Application Information
| Application ID | /XI3r7ApIhKtWweyY/KB+A== |
|---|---|
| Final Action Date | 2025-05-20 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0031406507 |
| Model | BRTM36 |
| Frequency Range | 450-452.575 MHz |
| Equipment Class | B9A - Part 90 Class A Industrial Booster (non-SMR) |
| Device Description | 400 MHz Digital TETRA Repeater |
| Responsible Party | Emmanuel Wensink, Head of product developement, emmanuel.wensink@eviden.com |
| Test Firm | Bruno Clavier, IIA LAB SERVICES, LLC, bruno.clavier@industrial-ia.com |
| TCB Email | tei@timcoengr.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Part 90.219 VHF signal Booster. Power output is conducted. The intended use is generally for industrial/commercial/public safety use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor or outdoor structures. RF exposure compliance will need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Sec. 1.1307(b)(3). This repeater is for private use and public safety operation. Class A signal booster. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| /XI3r7ApIhKtWweyY/KB+A== | 2025-05-20 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance |
|---|---|---|
| 450-452.575 MHz | 0.25 | Amp |
| 456-457.575 MHz | 0.25 | Amp |
Grants
TCB Grant - Application /XI3r7ApIhKtWweyY/KB+A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
IIA Lab Services, LLC 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 05/20/2025 Application Dated: 05/20/2025 |
| Eviden |
| C/O Eviden Austria Gmbh |
| Wagramer Strasse 19/Stock 16 |
| Vienna, 1220 Austria |
| Attention: Emmanuel Wensink , Head of product developement |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A289BRTM36 |
| Name of Grantee: | Eviden |
| Equipment Class: | Part 90 Class A Industrial Booster (non-SMR) |
| Notes: | 400 MHz Digital TETRA Repeater |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 452.575 | 0.25 | Amp | D7W | |
| 90 | 456.0 - 457.575 | 0.25 | Amp | D7W |
| Part 90.219 VHF signal Booster. Power output is conducted. The intended use is generally for industrial/commercial/public safety use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor or outdoor structures. RF exposure compliance will need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Sec. 1.1307(b)(3). This repeater is for private use and public safety operation. Class A signal booster. |