FCC ID 2A289BRTM36

400 MHz Digital TETRA Repeater

by Eviden

Grantee Code: 2A289   Product Code: BRTM36
Latest application date: 2025-05-20

FCC ID Device Details

FCC ID2A289BRTM36
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A289
Product CodeBRTM36
Applicant BusinessEviden 🇦🇹
Related Domains eviden.com
Equipment Class400 MHz Digital TETRA Repeater
Test FirmIIA LAB SERVICES, LLC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-452.575 MHzOriginal Equipment2025-05-20

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2025-05-20PDF 599.9 KB
Booster Label SampleID Label/Location Info2025-05-20PDF 1.3 MB
Label LocationID Label/Location Info2025-05-20PDF 3.4 MB
Label SampleID Label/Location Info2025-05-20PDF 1.4 MB
TSUPTest Setup Photos2025-05-20PDF 1.3 MB
Test ReportTest Report2025-05-20PDF 1.3 MB
Att Statements 2.911(d)(5)(7)Attestation Statements2025-05-20PDF 293.9 KB
Att Statements 2.911(d)(5)(i)&(ii)Attestation Statements2025-05-20PDF 110.2 KB
Booster AttestationCover Letter(s)2025-05-20PDF 171.3 KB
KDB AttestationAttestation Statements2025-05-20PDF 183.7 KB
Tuning AttestationCover Letter(s)2025-05-20PDF 182.4 KB
Confidentiality LetterCover Letter(s)2025-05-20PDF 236.3 KB
RF Exposure MPERF Exposure Info2025-05-20PDF 322.7 KB
User Manual Metadata onlyUsers ManualPDF 4.8 MB
Internal Photos Metadata onlyInternal PhotosPDF 2.2 MB
Block Diagram Metadata onlyBlock DiagramPDF 414 KB
Schematics Downlink Metadata onlySchematicsPDF 783.4 KB
Schematics Uplink Metadata onlySchematicsPDF 783.7 KB
Circuit Description Metadata onlyOperational DescriptionPDF 367.1 KB
BOM BRTL35-EA-03-V03 center Metadata onlyParts List/Tune Up InfoPDF 843.6 KB
BOM BUFI12-EK-01 Metadata onlyParts List/Tune Up InfoPDF 4.2 MB
BOM BUFI12-EK-02 Metadata onlyParts List/Tune Up InfoPDF 1.9 MB
BOM Digital Filter Metadata onlyParts List/Tune Up InfoPDF 1.3 MB
BOM downlink Metadata onlyParts List/Tune Up InfoPDF 1.1 MB
BOM secondary power supply Metadata onlyParts List/Tune Up InfoPDF 305.3 KB
BOM uplink Metadata onlyParts List/Tune Up InfoPDF 1.2 MB
Tune-up Procedure Metadata onlyParts List/Tune Up InfoPDF 280.9 KB

Application Information

Application ID/XI3r7ApIhKtWweyY/KB+A==
Final Action Date2025-05-20
Application PurposeOriginal Equipment
Applicant FRN0031406507
ModelBRTM36
Frequency Range450-452.575 MHz
Equipment ClassB9A - Part 90 Class A Industrial Booster (non-SMR)
Device Description400 MHz Digital TETRA Repeater
Responsible PartyEmmanuel Wensink, Head of product developement, emmanuel.wensink@eviden.com , +41794597604
Test FirmBruno Clavier, IIA LAB SERVICES, LLC, bruno.clavier@industrial-ia.com , 352-472-5500
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPart 90.219 VHF signal Booster. Power output is conducted. The intended use is generally for industrial/commercial/public safety use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor or outdoor structures. RF exposure compliance will need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Sec. 1.1307(b)(3). This repeater is for private use and public safety operation. Class A signal booster.

Applications

Application IDDatePurpose
/XI3r7ApIhKtWweyY/KB+A==2025-05-20Original Equipment

Equipment Authorization

FrequencyOutputTolerance
450-452.575 MHz0.25Amp
456-457.575 MHz0.25Amp

Grants

TCB Grant - Application /XI3r7ApIhKtWweyY/KB+A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 05/20/2025

Application Dated: 05/20/2025
Eviden
C/O Eviden Austria Gmbh
Wagramer Strasse 19/Stock 16
Vienna, 1220
Austria
 
Attention: Emmanuel Wensink , Head of product developement

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A289BRTM36
Name of Grantee:  Eviden
Equipment Class: Part 90 Class A Industrial Booster (non-SMR)
Notes: 400 MHz Digital TETRA Repeater
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  452.575 0.25  Amp D7W
90 456.0  -  457.575 0.25  Amp D7W

Part 90.219 VHF signal Booster. Power output is conducted. The intended use is generally for industrial/commercial/public safety use and will not be sold to the general public. Professional installation is required. The antenna(s) used for this transmitter are to be fixed-mounted on indoor or outdoor structures. RF exposure compliance will need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Sec. 1.1307(b)(3). This repeater is for private use and public safety operation.

Class A signal booster.