FCC ID 2A29YPM4204454

Premium ONU

by Radisys Corporation

Grantee Code: 2A29Y   Product Code: PM4204454
Latest application date: 2021-10-26

FCC ID Device Details

FCC ID2A29YPM4204454
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A29Y
Product CodePM4204454
Applicant BusinessRadisys Corporation 🇺🇸
Related Domains radisys.com
Equipment ClassPremium ONU
Test FirmBTL Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2021-10-26
2412-2462 MHzOriginal Equipment2021-10-26

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-10-26PDF 248.9 KB
Internal PhotosInternal Photos2021-10-26PDF 4.7 MB
External PhotosExternal Photos2021-10-26PDF 1.2 MB
Label LocationID Label/Location Info2021-10-26PDF 214.6 KB
Label and locationID Label/Location Info2021-10-26PDF 214.6 KB
Test Setup PhotosTest Setup Photos2021-10-26PDF 1.2 MB
Test ReportTest Report2021-10-26PDF 5.2 MB
Test ReportTest Report2021-10-26PDF 5.3 MB
Agent Authorization LetterCover Letter(s)2021-10-26PDF 20.1 KB
Agent Authorization Rev 1.0Cover Letter(s)2021-10-26PDF 20.1 KB
Authorization LetterCover Letter(s)2021-10-26PDF 20.1 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2021-10-26PDF 17.2 KB
FCC Software Configuration Control Declaration Rev1.0Cover Letter(s)2021-10-26PDF 17.2 KB
Wi-Fi Channel 12 and 13 Declaration Letter R01Cover Letter(s)2021-10-26PDF 19.6 KB
MPERF Exposure Info2021-10-26PDF 218.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 117.2 KB
SCH Metadata onlySchematicsPDF 1,006.6 KB
Schematic Metadata onlySchematicsPDF 1,006.6 KB
OP Metadata onlyOperational DescriptionPDF 161.8 KB
SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Metadata onlySDR Software/Security InfPDF 64.8 KB

Application Information

Application IDq0mqRijrZ0V2g1AGzOkmeg==
Final Action Date2021-10-26
Application PurposeOriginal Equipment
Applicant FRN0031424575
ModelPM4204454
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionPremium ONU
Responsible PartyMd Rahman, Regulatory Compliance Manager, md.rahman@radisys.com , 224-221-1417
Technical ContactRadisys Corporation, md.rahman@radisys.com
Test FirmSophia Huang, BTL Inc., Sophia.huang@newbtl.com , +86-769-83183000
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
q0mqRijrZ0V2g1AGzOkmeg==2021-10-26Original Equipment
ATubzGN+BJ/B1GnXoBFPGg==2021-10-26Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.737900015CCC, MO
5180-5240 MHz0.08315E38, CC, MO
5745-5825 MHz0.075915E38, CC, MO

Grants

TCB Grant - Application q0mqRijrZ0V2g1AGzOkmeg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 10/26/2021

Application Dated: 10/26/2021
Radisys Corporation
8900 NE Walker Road, Suite# 130
Hillsboro, OR 97006
 
Attention: Md Rahman , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A29YPM4204454
Name of Grantee:  Radisys Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Premium ONU
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.083  
38 CC MO 15E 5745.0  -  5825.0 0.0759  

Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application q0mqRijrZ0V2g1AGzOkmeg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Radisys Corporation
8900 NE Walker Road, Suite# 130
Hillsboro, OR 97006
United States
  Date of Grant: 10/26/2021

Application Dated: 10/26/2021
 
Attention: Md Rahman , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A29YPM4204454
Name of Grantee:  Radisys Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Premium ONU
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.083  
38 CC MO 15E 5745.0  -  5825.0 0.0759  

Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application ATubzGN+BJ/B1GnXoBFPGg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 10/26/2021

Application Dated: 10/26/2021
Radisys Corporation
8900 NE Walker Road, Suite# 130
Hillsboro, OR 97006
 
Attention: Md Rahman , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A29YPM4204454
Name of Grantee:  Radisys Corporation
Equipment Class: Digital Transmission System
Notes: Premium ONU
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.7379  

Output power listed is maximum combined conducted power. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application ATubzGN+BJ/B1GnXoBFPGg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Radisys Corporation
8900 NE Walker Road, Suite# 130
Hillsboro, OR 97006
United States
  Date of Grant: 10/26/2021

Application Dated: 10/26/2021
 
Attention: Md Rahman , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A29YPM4204454
Name of Grantee:  Radisys Corporation
Equipment Class: Digital Transmission System
Notes: Premium ONU
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.7379  

Output power listed is maximum combined conducted power. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: