FCC ID 2A2CL-CRS08RXSB

Scan Bridge, Creality RaptorX & Scan Bridge Kit

by Orbbec Inc.

Grantee Code: 2A2CL   Product Code: CRS08RXSB
Latest application date: 2024-12-05

FCC ID Device Details

FCC ID2A2CL-CRS08RXSB
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A2CL
Product CodeCRS08RXSB
Applicant BusinessOrbbec Inc. 🇨🇳
Related Domains orbbec.com
Equipment ClassScan Bridge, Creality RaptorX & Scan Bridge Kit
Test FirmShenzhen Morlab Communications Technology Co. Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AXH6-CRS08RXSB Grant Date: 11/28/20242024-12-05

Exhibits

DocumentTypeAvailableFile
UM-CRP04SBUsers Manual2025-06-04PDF 2.2 MB
User_manualUsers Manual2025-06-04PDF 3.3 MB
External_PhotosExternal Photos2025-06-04PDF 2.9 MB
label&locaiton-1ID Label/Location Info2024-12-05PDF 427 KB
label&location-2ID Label/Location Info2024-12-05PDF 538.5 KB
Attestation_Letter_COVERED_EQUIPMENTAttestation Statements2024-12-05PDF 113.2 KB
Attestation_Letter_US_AgentAttestation Statements2024-12-05PDF 172 KB
Authorization_LetterCover Letter(s)2024-12-05PDF 15.8 KB
Confidentiality_Request_LetterCover Letter(s)2024-12-05PDF 164 KB
DTS_UNII_DeclarationCover Letter(s)2024-12-05PDF 124 KB
FCC_Change_in_ID_AuthorizationLetterCover Letter(s)2024-12-05PDF 501.5 KB
FCC_Change_in_ID_RequestCover Letter(s)2024-12-05PDF 404.2 KB
Software_Security_Description Metadata onlySDR Software/Security Info.PDF 254.3 KB

Application Information

Application IDLbFdkzZ1okqbwVzMdYg6vA==
Final Action Date2024-12-05
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: 2AXH6-CRS08RXSB Grant Date: 11/28/2024
Applicant FRN0031050834
ModelCRS08RXSB
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionScan Bridge, Creality RaptorX & Scan Bridge Kit
Responsible PartyYao Yan, Project Manager, fuxi@orbbec.com , 16620826658
Test FirmMr. Su Feng, Shenzhen Morlab Communications Technology Co. Ltd., Zx.sun@morlab.cn , +86 755 36698566
TCB Emailbentje.holger@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date06/04/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is maximum average conducted.This device supports IEEE 802.11 a/n/ac/ax 20, 40 and 80 MHz channel bandwidths.SAR compliance for limb operating configurations is provide 0 mm separation between the device and the user. End-users must be informed of the limb operating requirements for satisfying RF exposure compliance.Product specific SAR at 10-gram tissue is 1.44 W/kg.

Applications

Application IDDatePurpose
LbFdkzZ1okqbwVzMdYg6vA==2024-12-05Change in identification of presently authorized equipment. Original FCC ID: 2AXH6-CRS08RXSB Grant Date: 11/28/2024

Equipment Authorization

FrequencyOutputRulesGrant Notes
5180-5240 MHz0.0539115EMO
5745-5825 MHz0.0519615EMO

Grants

TCB Grant - Application LbFdkzZ1okqbwVzMdYg6vA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 12/05/2024

Application Dated: 12/05/2024
Orbbec Inc.
11-13/F,Union Tower Hi-tech Zone,
No.63 Xuefu Rd.,Nanshan Dist.,
Shenzhen, 518052
China
 
Attention: Yao Yan , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A2CL-CRS08RXSB
Name of Grantee:  Orbbec Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Scan Bridge, Creality RaptorX & Scan Bridge Kit
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5180.0  -  5240.0 0.05391  
MO 15E 5745.0  -  5825.0 0.05196  

Output power is maximum average conducted.
This device supports IEEE 802.11 a/n/ac/ax 20, 40 and 80 MHz channel bandwidths.
SAR compliance for limb operating configurations is provide 0 mm separation between the device and the user. End-users must be informed of the limb operating requirements for satisfying RF exposure compliance.
Product specific SAR at 10-gram tissue is 1.44 W/kg.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application LbFdkzZ1okqbwVzMdYg6vA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Orbbec Inc.
11-13/F,Union Tower Hi-tech Zone, No.63 Xuefu Rd.,Nanshan Dist.,
Shenzhen, 518052
China
  Date of Grant: 12/05/2024

Application Dated: 12/05/2024
 
Attention: Yao Yan , Project Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A2CL-CRS08RXSB
Name of Grantee:  Orbbec Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Scan Bridge, Creality RaptorX & Scan Bridge Kit
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5180.0  -  5240.0 0.05391  
MO 15E 5745.0  -  5825.0 0.05196  

Output power is maximum average conducted.
This device supports IEEE 802.11 a/n/ac/ax 20, 40 and 80 MHz channel bandwidths.
SAR compliance for limb operating configurations is provide 0 mm separation between the device and the user. End-users must be informed of the limb operating requirements for satisfying RF exposure compliance.
Product specific SAR at 10-gram tissue is 1.44 W/kg.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: