FCC ID 2A39R-MEGAMIFI
OmegaWireless
by Omega Analytics Inc
Grantee Code: 2A39R Product Code: MEGAMIFI
Latest application date: 2022-01-28
FCC ID Device Details
| FCC ID | 2A39R-MEGAMIFI |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A39R |
| Product Code | MEGAMIFI |
| Applicant Business | Omega Analytics Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | OmegaWireless |
| Test Firm | Shenzhen Anbotek Compliance Laboratory Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 704-711 MHz | Original Equipment | 2022-01-28 |
| 2412-2462 MHz | Original Equipment | 2022-01-27 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2022-01-28 | PDF 2 MB |
| User manual | Users Manual | 2022-01-27 | PDF 2 MB |
| Internal Photos | Internal Photos | 2022-01-28 | PDF 1.8 MB |
| Internal photos | Internal Photos | 2022-01-27 | PDF 1.8 MB |
| External Photos | External Photos | 2022-01-28 | PDF 545.6 KB |
| External photos | External Photos | 2022-01-27 | PDF 545.6 KB |
| Label and location | ID Label/Location Info | 2022-01-28 | PDF 139.1 KB |
| Label Location | ID Label/Location Info | 2022-01-27 | PDF 139.1 KB |
| Test Setup Photos | Test Setup Photos | 2022-01-28 | PDF 535.2 KB |
| Test Report | Test Report | 2022-01-28 | PDF 5.9 MB |
| Test Report SAR | RF Exposure Info | 2022-01-28 | PDF 4.9 MB |
| Test Report | Test Report | 2022-01-27 | PDF 4.1 MB |
| Declaration Letter of Model Difference | Cover Letter(s) | 2022-01-28 | PDF 94.8 KB |
| FCC_Short Long Term Confidentiality Request_EZDS_rev2 | Cover Letter(s) | 2022-01-28 | PDF 96.5 KB |
| Letter of Authorization Rev 2.0 | Cover Letter(s) | 2022-01-28 | PDF 97.2 KB |
| Letter of Authorization | Cover Letter(s) | 2022-01-27 | PDF 97.2 KB |
| Block Metadata only | Block Diagram | PDF 106.4 KB | |
| BlockDiagram Metadata only | Block Diagram | PDF 106.4 KB | |
| SCH Metadata only | Schematics | PDF 376.7 KB | |
| OP Metadata only | Operational Description | PDF 231.4 KB | |
| Operation Description Metadata only | Operational Description | PDF 231.4 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 50.6 KB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 104.8 KB |
Application Information
| Application ID | E+1Aie8LoqG71FN+5xfpcw== |
|---|---|
| Final Action Date | 2022-01-28 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0031836836 |
| Model | MEGAMIFI |
| Frequency Range | 704-711 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | OmegaWireless |
| Responsible Party | Joe Miskell, Manager, support@omega-analytics.net |
| Technical Contact | Omega Analytics Inc, support@omega-analytics.net |
| Test Firm | Jeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.69W/kg and 1.22W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| E+1Aie8LoqG71FN+5xfpcw== | 2022-01-28 | Original Equipment |
| dZ3IYlJcZUGElhMmX9PHLA== | 2022-01-27 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 704-711 MHz | 0.2028 | 2.5ppm | 9M00G7D | 27 |
| 704-711 MHz | 0.1315 | 2.5ppm | 8M98W7D | 27 |
| 782 MHz | 0.1687 | 2.5ppm | 9M02G7D | 27 |
| 782 MHz | 0.1622 | 2.5ppm | 9M04W7D | 27 |
| 1720-1770 MHz | 0.1489 | 2.5ppm | 17M9W7D | 27 |
| 1720-1745 MHz | 0.5 | 2.5ppm | 17M9G7D | 27 |
| 1720-1745 MHz | 0.1247 | 2.5ppm | 17M9W7D | 27 |
| 1720-1770 MHz | 0.3013 | 2.5ppm | 17M9G7D | 27 |
| 1860-1900 MHz | 0.1489 | 2.5ppm | 17M9W7D | 24E |
| 2412-2462 MHz | 0.0578000 | 15C |
Grants
TCB Grant - Application E+1Aie8LoqG71FN+5xfpcw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 01/28/2022 Application Dated: 01/27/2022 |
| Omega Analytics Inc |
| 129 S. Main Street STE 260 |
| Grapevine, TX 76051 |
| Attention: Joe Miskell , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A39R-MEGAMIFI |
| Name of Grantee: | Omega Analytics Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | OmegaWireless |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1860.0 - 1900.0 | 0.3013 | 2.5 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.1489 | 2.5 PM | 17M9W7D | |
| 27 | 1720.0 - 1745.0 | 0.5 | 2.5 PM | 17M9G7D | |
| 27 | 1720.0 - 1745.0 | 0.1247 | 2.5 PM | 17M9W7D | |
| 27 | 704.0 - 711.0 | 0.2028 | 2.5 PM | 9M00G7D | |
| 27 | 704.0 - 711.0 | 0.1315 | 2.5 PM | 8M98W7D | |
| 27 | 782.0 - 782.0 | 0.1687 | 2.5 PM | 9M02G7D | |
| 27 | 782.0 - 782.0 | 0.1622 | 2.5 PM | 9M04W7D | |
| 27 | 1720.0 - 1770.0 | 0.3013 | 2.5 PM | 17M9G7D | |
| 27 | 1720.0 - 1770.0 | 0.1489 | 2.5 PM | 17M9W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.69W/kg and 1.22W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
EAS Grant - Application E+1Aie8LoqG71FN+5xfpcw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Omega Analytics Inc 129 S. Main Street STE 260 Grapevine, TX 76051 United States |
Date of Grant: 01/28/2022 Application Dated: 01/27/2022 |
| Attention: Joe Miskell , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A39R-MEGAMIFI |
| Name of Grantee: | Omega Analytics Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | OmegaWireless |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1860.0 - 1900.0 | 0.3013 | 2.5 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.1489 | 2.5 PM | 17M9W7D | |
| 27 | 1720.0 - 1745.0 | 0.5 | 2.5 PM | 17M9G7D | |
| 27 | 1720.0 - 1745.0 | 0.1247 | 2.5 PM | 17M9W7D | |
| 27 | 704.0 - 711.0 | 0.2028 | 2.5 PM | 9M00G7D | |
| 27 | 704.0 - 711.0 | 0.1315 | 2.5 PM | 8M98W7D | |
| 27 | 782.0 - 782.0 | 0.1687 | 2.5 PM | 9M02G7D | |
| 27 | 782.0 - 782.0 | 0.1622 | 2.5 PM | 9M04W7D | |
| 27 | 1720.0 - 1770.0 | 0.3013 | 2.5 PM | 17M9G7D | |
| 27 | 1720.0 - 1770.0 | 0.1489 | 2.5 PM | 17M9W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.69W/kg and 1.22W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 01/27/2022 Application Dated: 01/27/2022 |
| Omega Analytics Inc |
| 129 S. Main Street STE 260 |
| Grapevine, TX 76051 |
| Attention: Joe Miskell , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A39R-MEGAMIFI |
| Name of Grantee: | Omega Analytics Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | OmegaWireless |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0578 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.53W/kg and 1.22W/kg respectively. |
EAS Grant - Application dZ3IYlJcZUGElhMmX9PHLA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Omega Analytics Inc 129 S. Main Street STE 260 Grapevine, TX 76051 United States |
Date of Grant: 01/27/2022 Application Dated: 01/27/2022 |
| Attention: Joe Miskell , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A39R-MEGAMIFI |
| Name of Grantee: | Omega Analytics Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | OmegaWireless |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0578 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.53W/kg and 1.22W/kg respectively. |
| Mail To: |