FCC ID 2A3BOX501

smartphone

by Gesoper, S de R.L. de C.V

Grantee Code: 2A3BO   Product Code: X501
Latest application date: 2021-11-01

FCC ID Device Details

FCC ID2A3BOX501
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A3BO
Product CodeX501
Applicant BusinessGesoper, S de R.L. de C.V 🇲🇽
Related Domains tjdlatam.com
Equipment Classsmartphone
Test FirmSHENZHEN STS TEST SERVICES CO.,LTD.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2021-11-01
2402-2480 MHzOriginal Equipment2021-11-01
2402-2480 MHzOriginal Equipment2021-11-01

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-11-01PDF 3.6 MB
Int EUT PHOTOInternal Photos2021-11-01PDF 1.9 MB
Internal PhotoInternal Photos2021-11-01PDF 1.9 MB
Internal photosInternal Photos2021-11-01PDF 1.9 MB
External PhotosExternal Photos2021-11-01PDF 1.6 MB
External photosExternal Photos2021-11-01PDF 1.6 MB
LabelID Label/Location Info2021-11-01PDF 260.2 KB
Label LocationID Label/Location Info2021-11-01PDF 260.2 KB
Label and locationID Label/Location Info2021-11-01PDF 260.2 KB
Test Setup PhotosSARTest Setup Photos2021-11-01PDF 216.2 KB
Test Setup photoSARTest Setup Photos2021-11-01PDF 216.2 KB
Test setup photoTest Setup Photos2021-11-01PDF 398.9 KB
Test setup photoTest Setup Photos2021-11-01PDF 576.9 KB
Test ReportTest Report2021-11-01PDF 3.4 MB
Test ReportTest Report2021-11-01PDF 4.2 MB
Test ReportTest Report2021-11-01PDF 4.2 MB
Test Report SARRF Exposure Info2021-11-01PDF 2.3 MB
Test Report SARRF Exposure Info2021-11-01PDF 3.2 MB
Agent Authorization Rev 1.0Cover Letter(s)2021-11-01PDF 22.7 KB
FCC AuthorizationLetter for STS LabCover Letter(s)2021-11-01PDF 356.6 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2021-11-01PDF 79.6 KB
SAR_SAR Calibration ReportRF Exposure Info2021-11-01PDF 3.2 MB
Block Diagram Metadata onlyBlock DiagramPDF 10.7 KB
SCH Metadata onlySchematicsPDF 241.8 KB
Schematic Metadata onlySchematicsPDF 241.8 KB
OP Metadata onlyOperational DescriptionPDF 223 KB
Operation Description Metadata onlyOperational DescriptionPDF 223 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 54.5 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 211.6 KB

Application Information

Application IDzphf4GYIa1EMLmC5rNl1CA==
Final Action Date2021-11-01
Application PurposeOriginal Equipment
Applicant FRN0031443567
ModelX501
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device Descriptionsmartphone
Responsible PartyNicolas Slim, Director, nicolas@tjdlatam.com , +52 5535001367
Technical ContactGesoper, S de R.L. de C.V, nicolas@tjdlatam.com
Test FirmBovey Yang, SHENZHEN STS TEST SERVICES CO.,LTD., Bovey@stsapp.com , +86 755-36886288
TCB Emailcertification@micomlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.76W/kg , 1.21W/kg and 1.58W/kg respectively.

Applications

Application IDDatePurpose
zphf4GYIa1EMLmC5rNl1CA==2021-11-01Original Equipment
g3D+QF08ZJImSNvwwWmzDg==2021-11-01Original Equipment
4+9q4LjAxPkipHp4eeZiLA==2021-11-01Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz1.69430.041ppm247KGXW22H
824.2-848.8 MHz0.37930.041ppm246KG7W22H
826.4-846.6 MHz0.20650.041ppm4M65F9W22H
1850.2-1909.8 MHz0.65160.019ppm246KGXW24E
1850.2-1909.8 MHz0.35650.019ppm247KG7W24E
1852.4-1907.6 MHz0.16330.019ppm4M15F9W24E
2402-2480 MHz0.003515CCC
2402-2480 MHz0.003600015CCC
2412-2462 MHz0.08315CCC

Grants

TCB Grant - Application zphf4GYIa1EMLmC5rNl1CA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 11/01/2021

Application Dated: 11/01/2021
Gesoper, S de R.L. de C.V
Plinio 146, Col: Polanco II Seccion,
Del: Miguel Hidalgo, C.p: 11530,
Ciudad de Mexico,
Mexico
 
Attention: Nicolas Slim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3BOX501
Name of Grantee:  Gesoper, S de R.L. de C.V
Equipment Class: PCS Licensed Transmitter held to ear
Notes: smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.6943 0.041  PM 247KGXW
22H 824.2  -  848.8 0.3793 0.041  PM 246KG7W
24E 1850.2  -  1909.8 0.6516 0.019  PM 246KGXW
24E 1850.2  -  1909.8 0.3565 0.019  PM 247KG7W
22H 826.4  -  846.6 0.2065 0.041  PM 4M65F9W
24E 1852.4  -  1907.6 0.1633 0.019  PM 4M15F9W

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.76W/kg , 1.21W/kg and 1.58W/kg respectively.

EAS Grant - Application zphf4GYIa1EMLmC5rNl1CA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Gesoper, S de R.L. de C.V
Plinio 146, Col: Polanco II Seccion, Del: Miguel Hidalgo, C.p: 11530,
Ciudad de Mexico,
Mexico
  Date of Grant: 11/01/2021

Application Dated: 11/01/2021
 
Attention: Nicolas Slim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3BOX501
Name of Grantee:  Gesoper, S de R.L. de C.V
Equipment Class: PCS Licensed Transmitter held to ear
Notes: smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.6943 0.041  PM 247KGXW
22H 824.2  -  848.8 0.3793 0.041  PM 246KG7W
24E 1850.2  -  1909.8 0.6516 0.019  PM 246KGXW
24E 1850.2  -  1909.8 0.3565 0.019  PM 247KG7W
22H 826.4  -  846.6 0.2065 0.041  PM 4M65F9W
24E 1852.4  -  1907.6 0.1633 0.019  PM 4M15F9W

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.76W/kg , 1.21W/kg and 1.58W/kg respectively.



TCB Grant - Application g3D+QF08ZJImSNvwwWmzDg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 11/01/2021

Application Dated: 11/01/2021
Gesoper, S de R.L. de C.V
Plinio 146, Col: Polanco II Seccion,
Del: Miguel Hidalgo, C.p: 11530,
Ciudad de Mexico,
Mexico
 
Attention: Nicolas Slim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3BOX501
Name of Grantee:  Gesoper, S de R.L. de C.V
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0036  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.12W/kg , 0.12W/kg and 1.58W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application g3D+QF08ZJImSNvwwWmzDg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Gesoper, S de R.L. de C.V
Plinio 146, Col: Polanco II Seccion, Del: Miguel Hidalgo, C.p: 11530,
Ciudad de Mexico,
Mexico
  Date of Grant: 11/01/2021

Application Dated: 11/01/2021
 
Attention: Nicolas Slim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3BOX501
Name of Grantee:  Gesoper, S de R.L. de C.V
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0036  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.12W/kg , 0.12W/kg and 1.58W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 4+9q4LjAxPkipHp4eeZiLA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 11/01/2021

Application Dated: 11/01/2021
Gesoper, S de R.L. de C.V
Plinio 146, Col: Polanco II Seccion,
Del: Miguel Hidalgo, C.p: 11530,
Ciudad de Mexico,
Mexico
 
Attention: Nicolas Slim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3BOX501
Name of Grantee:  Gesoper, S de R.L. de C.V
Equipment Class: Digital Transmission System
Notes: smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0035  
CC 15C 2412.0  -  2462.0 0.083  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.37W/kg , 0.37W/kg and 1.58W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 4+9q4LjAxPkipHp4eeZiLA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Gesoper, S de R.L. de C.V
Plinio 146, Col: Polanco II Seccion, Del: Miguel Hidalgo, C.p: 11530,
Ciudad de Mexico,
Mexico
  Date of Grant: 11/01/2021

Application Dated: 11/01/2021
 
Attention: Nicolas Slim , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3BOX501
Name of Grantee:  Gesoper, S de R.L. de C.V
Equipment Class: Digital Transmission System
Notes: smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0035  
CC 15C 2412.0  -  2462.0 0.083  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.37W/kg , 0.37W/kg and 1.58W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: