FCC ID 2A3HV-CVC15A
Hydrow Touchscreen Monitor
by Hydrow, Inc.
Grantee Code: 2A3HV Product Code: CVC15A
Latest application date: 2022-04-13
FCC ID Device Details
| FCC ID | 2A3HV-CVC15A |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A3HV |
| Product Code | CVC15A |
| Applicant Business | Hydrow, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Hydrow Touchscreen Monitor |
| Test Firm | Guangzhou GRG Metrology & Test Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2022-04-13 |
| 2402-2480 MHz | Original Equipment | 2022-04-13 |
| 5180-5240 MHz | Original Equipment | 2022-04-13 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2022-10-08 | PDF 426.4 KB |
| Internal photos | Internal Photos | 2022-10-08 | PDF 2.4 MB |
| External photos | External Photos | 2022-10-08 | PDF 114.7 KB |
| ID label and location | ID Label/Location Info | 2022-04-13 | PDF 216.4 KB |
| Test setup photos | Test Setup Photos | 2022-10-08 | PDF 119.2 KB |
| Test reports | Test Report | 2022-04-13 | PDF 5.7 MB |
| Test reports | Test Report | 2022-04-13 | PDF 5.1 MB |
| Test reports | Test Report | 2022-04-13 | PDF 4.7 MB |
| Confidentiality | Cover Letter(s) | 2022-04-13 | PDF 126.6 KB |
| Letter Authorization | Cover Letter(s) | 2022-04-13 | PDF 85.9 KB |
| Software_Configuration_Control | Cover Letter(s) | 2022-04-13 | PDF 51.6 KB |
| RF Exposure | RF Exposure Info | 2022-04-13 | PDF 1.6 MB |
| Block Diagram Metadata only | Block Diagram | PDF 167.9 KB | |
| Schematics Metadata only | Schematics | PDF 680.8 KB | |
| Operational Description Metadata only | Operational Description | PDF 278.6 KB | |
| Secutiry Info. Metadata only | SDR Software/Security Inf | PDF 100.6 KB |
Application Information
| Application ID | y2G05ZxjasuHjSxFWrQc3g== |
|---|---|
| Final Action Date | 2022-04-13 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0031549983 |
| Model | CVC15A |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Hydrow Touchscreen Monitor |
| Responsible Party | Michael Barnes, mike.barnes@hydrow.com |
| Technical Contact | Krystal Yang, GRG Metrology & Test (Shenzhen) Co.,Ltd., yanghy2@grgtest.com |
| Test Firm | Frank Chen, Guangzhou GRG Metrology & Test Co., Ltd., frank.chen@grgtest.com |
| TCB Email | elabscert@applus.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 10/08/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted peak power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| y2G05ZxjasuHjSxFWrQc3g== | 2022-04-13 | Original Equipment |
| gJye/jKLjd4oQiQxApFpBg== | 2022-04-13 | Original Equipment |
| Bo7VLGrYShalKOitANq/yA== | 2022-04-13 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application y2G05ZxjasuHjSxFWrQc3g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 04/13/2022 Application Dated: 04/12/2022 |
| Hydrow, Inc. |
| 10 Summer St |
| Floor 5 |
| Boston, MA 02210 |
| Attention: Michael Barnes |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3HV-CVC15A |
| Name of Grantee: | Hydrow, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Hydrow Touchscreen Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00467 |
| Output power listed is conducted peak power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application y2G05ZxjasuHjSxFWrQc3g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hydrow, Inc. 10 Summer St Floor 5 Boston, MA 02210 United States |
Date of Grant: 04/13/2022 Application Dated: 04/12/2022 |
| Attention: Michael Barnes |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3HV-CVC15A |
| Name of Grantee: | Hydrow, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Hydrow Touchscreen Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00467 |
| Output power listed is conducted peak power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 04/13/2022 Application Dated: 04/12/2022 |
| Hydrow, Inc. |
| 10 Summer St |
| Floor 5 |
| Boston, MA 02210 |
| Attention: Michael Barnes |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3HV-CVC15A |
| Name of Grantee: | Hydrow, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Hydrow Touchscreen Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00183 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.41687 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application gJye/jKLjd4oQiQxApFpBg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hydrow, Inc. 10 Summer St Floor 5 Boston, MA 02210 United States |
Date of Grant: 04/13/2022 Application Dated: 04/12/2022 |
| Attention: Michael Barnes |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3HV-CVC15A |
| Name of Grantee: | Hydrow, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Hydrow Touchscreen Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00183 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.41687 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 04/13/2022 Application Dated: 04/12/2022 |
| Hydrow, Inc. |
| 10 Summer St |
| Floor 5 |
| Boston, MA 02210 |
| Attention: Michael Barnes |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3HV-CVC15A |
| Name of Grantee: | Hydrow, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Hydrow Touchscreen Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.05309 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.05998 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth.Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application Bo7VLGrYShalKOitANq/yA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hydrow, Inc. 10 Summer St Floor 5 Boston, MA 02210 United States |
Date of Grant: 04/13/2022 Application Dated: 04/12/2022 |
| Attention: Michael Barnes |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3HV-CVC15A |
| Name of Grantee: | Hydrow, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Hydrow Touchscreen Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.05309 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.05998 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth.Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |