FCC ID 2A3JW-SAPPHIRE

SappireConnect

by Eitan Medical Ltd.

Grantee Code: 2A3JW   Product Code: SAPPHIRE
Latest application date: 2022-08-19

FCC ID Device Details

FCC ID2A3JW-SAPPHIRE
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A3JW
Product CodeSAPPHIRE
Applicant BusinessEitan Medical Ltd. 🇮🇱
Related Domains eitanmedical.com
Equipment ClassSappireConnect
Test FirmShenzhen Huatongwei International Inspection Co.,

Linked Records

Barcode records decoded from published FCC label exhibits or linked by an explicit FCC ID reference on a product page.

UPC / GTINLinked product
7290109154305
EAN-13 · GTIN-14 07290109154305
Sapphire Connect EM25
Brand: Eitan Medical Ltd. · Model: EM25
Source: FCC label

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
699.2-715.8 MHzOriginal Equipment2022-08-19

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-02-15PDF 5.8 MB
User manaulUsers Manual2023-02-15PDF 5.3 MB
User manualUsers Manual2023-02-15PDF 5.3 MB
Internal photosInternal Photos2023-02-15PDF 3.2 MB
External photosExternal Photos2023-02-15PDF 566.2 KB
LabelID Label/Location Info2022-08-19PDF 359.9 KB
Test photosTest Setup Photos2023-02-15PDF 109.3 KB
Test setup PhotosTest Setup Photos2023-02-15PDF 76.2 KB
Test ReportTest Report2022-08-19PDF 4.9 MB
Agent AuthorizationCover Letter(s)2022-08-19PDF 12.8 KB
FCC Long Term Only Confidentiality Request Rev4.1Cover Letter(s)2022-08-19PDF 91.5 KB
SAR ReportRF Exposure Info2022-08-19PDF 1.5 MB
SAR reportRF Exposure Info2022-08-19PDF 2.4 MB
BLOCK Diagram Metadata onlyBlock DiagramPDF 459.6 KB
SCH Metadata onlySchematicsPDF 1.3 MB
Operational Description Metadata onlyOperational DescriptionPDF 85.2 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 763 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 310.5 KB

Application Information

Application IDMGRbT4KlubgQsOV2J6pAkA==
Final Action Date2022-08-19
Application PurposeOriginal Equipment
Applicant FRN0031574387
ModelSAPPHIRE
Frequency Range699.2-715.8 MHz
Equipment ClassPCT - PCS Licensed Transmitter worn on body
Device DescriptionSappireConnect
Responsible PartyTzion Priav, HW Engineer, Yael.Marmary@eitanmedical.com , 054-6617589
Technical ContactEitan Medical Ltd., Yael.Marmary@eitanmedical.com
Test FirmJason Liu, Shenzhen Huatongwei International Inspection Co.,, quality@szhtw.com.cn , +86-755-26748078
TCB Emailcertification@micomlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date02/15/2023
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body SAR accessory is 0.51 W/kg.

Applications

Application IDDatePurpose
MGRbT4KlubgQsOV2J6pAkA==2022-08-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
699.2-715.8 MHz0.2210.00942ppm185KG7D27
699.7-715.3 MHz0.2290.00937ppm1M12G7D27
699.7-715.3 MHz0.2090.00955ppm952KW7D27
824.2-848.8 MHz0.4380.0095ppm248KG7W22H
824.2-848.8 MHz1.7660.0082ppm248KGXW22H
1710.7-1754.3 MHz0.2340.00955ppm1M13G7D27
1710.7-1754.3 MHz0.2380.00941ppm974KW7D27
1850.2-1909.8 MHz0.2480.00928ppm187KG7D24E
1850.2-1909.8 MHz1.040.00956ppm248KGXW24E
1850.2-1909.8 MHz0.3960.009ppm248KG7W24E
1850.7-1909.3 MHz0.2310.00954ppm982KW7D24E
1850.7-1909.3 MHz0.2240.00957ppm1M14G7D24E

Grants

TCB Grant - Application MGRbT4KlubgQsOV2J6pAkA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/19/2022

Application Dated: 08/19/2022
Eitan Medical Ltd.
29 Yad Haruzim St.
P.O. Box 8639,
Netanya, 4250529
Israel
 
Attention: Tzion Priav , HW Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3JW-SAPPHIRE
Name of Grantee:  Eitan Medical Ltd.
Equipment Class: PCS Licensed Transmitter worn on body
Notes: SappireConnect
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 1710.2  -  1754.8 0.237 0.00943  PM 184KG7D
27 1710.7  -  1754.3 0.234 0.00955  PM 1M13G7D
27 1710.7  -  1754.3 0.238 0.00941  PM 974KW7D
24E 1850.2  -  1909.8 0.248 0.00928  PM 187KG7D
24E 1850.2  -  1909.8 1.04 0.00956  PM 248KGXW
24E 1850.2  -  1909.8 0.396 0.009  PM 248KG7W
24E 1850.7  -  1909.3 0.231 0.00954  PM 982KW7D
24E 1850.7  -  1909.3 0.224 0.00957  PM 1M14G7D
27 699.2  -  715.8 0.221 0.00942  PM 185KG7D
27 699.7  -  715.3 0.229 0.00937  PM 1M12G7D
27 699.7  -  715.3 0.209 0.00955  PM 952KW7D
22H 824.2  -  848.8 0.438 0.0095  PM 248KG7W
22H 824.2  -  848.8 1.766 0.0082  PM 248KGXW

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body SAR accessory is 0.51 W/kg.

EAS Grant - Application MGRbT4KlubgQsOV2J6pAkA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Eitan Medical Ltd.
29 Yad Haruzim St. P.O. Box 8639,
Netanya, 4250529
Israel
  Date of Grant: 08/19/2022

Application Dated: 08/19/2022
 
Attention: Tzion Priav , HW Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3JW-SAPPHIRE
Name of Grantee:  Eitan Medical Ltd.
Equipment Class: PCS Licensed Transmitter worn on body
Notes: SappireConnect
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 1710.2  -  1754.8 0.237 0.00943  PM 184KG7D
27 1710.7  -  1754.3 0.234 0.00955  PM 1M13G7D
27 1710.7  -  1754.3 0.238 0.00941  PM 974KW7D
24E 1850.2  -  1909.8 0.248 0.00928  PM 187KG7D
24E 1850.2  -  1909.8 1.04 0.00956  PM 248KGXW
24E 1850.2  -  1909.8 0.396 0.009  PM 248KG7W
24E 1850.7  -  1909.3 0.231 0.00954  PM 982KW7D
24E 1850.7  -  1909.3 0.224 0.00957  PM 1M14G7D
27 699.2  -  715.8 0.221 0.00942  PM 185KG7D
27 699.7  -  715.3 0.229 0.00937  PM 1M12G7D
27 699.7  -  715.3 0.209 0.00955  PM 952KW7D
22H 824.2  -  848.8 0.438 0.0095  PM 248KG7W
22H 824.2  -  848.8 1.766 0.0082  PM 248KGXW

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body SAR accessory is 0.51 W/kg.



Mail To: