FCC ID 2A3OORT73

Mini Mobile Radio

by Shenzhen Ysair Technology Co., LTD

Grantee Code: 2A3OO   Product Code: RT73
Latest application date: 2022-01-18

FCC ID Device Details

FCC ID2A3OORT73
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A3OO
Product CodeRT73
Applicant BusinessShenzhen Ysair Technology Co., LTD 🇨🇳
Equipment ClassMini Mobile Radio
Test FirmShenzhen Accurate Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
406.1-480 MHzChange in identification of presently authorized equipment. Original FCC ID: VO6CDR-300UV Grant Date: 08/19/20212022-01-18
136-174 MHzChange in identification of presently authorized equipment. Original FCC ID: VO6CDR-300UV Grant Date: 08/19/20212022-01-18

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2022-07-18PDF 1.2 MB
ID Label and Label LocationID Label/Location Info2022-01-18PDF 512 KB
Scanning Receiver DeclarationAttestation Statements2022-01-18PDF 21.2 KB
Authorization Letter from Original GranteeCover Letter(s)2022-01-18PDF 54.5 KB
Change in ID Request LetterCover Letter(s)2022-01-18PDF 64.6 KB
FCC Short Term Confidentiality FormCover Letter(s)2022-01-18PDF 177.9 KB
POACover Letter(s)2022-01-18PDF 23 KB

Application Information

Application IDNc/GFs+f+0mndEwxwk8CuA==
Final Action Date2022-01-18
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: VO6CDR-300UV Grant Date: 08/19/2021
Applicant FRN0031641426
ModelRT73
Frequency Range406.1-480 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionMini Mobile Radio
Responsible PartyWeidong Shen, shenweidong02@126.com , +86-755-23481953
Test FirmLisa Zhang, Shenzhen Accurate Technology Co., Ltd., qa@atc-lab.com , +86-755-26503290
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date07/18/2022
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is maximum rated conducted power at antenna port. The minimum output setting is 5 W. This transmitter must be restricted to work related operations in an Occupational/Controlled RF exposure environment, not exceeding a maximum transmitting duty factor of 50%. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50 cm from all persons. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
Nc/GFs+f+0mndEwxwk8CuA==2022-01-18Change in identification of presently authorized equipment. Original FCC ID: VO6CDR-300UV Grant Date: 08/19/2021
LhgWt5KjClkCQuJoBnpweQ==2022-01-18Change in identification of presently authorized equipment. Original FCC ID: VO6CDR-300UV Grant Date: 08/19/2021

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
136-174 MHz15B
136-174 MHz202.5ppm11K0F3E9EF
136-174 MHz202.5ppm7K60F1D9EF, ES
136-174 MHz202.5ppm7K60F1E9EF, ES
400-480 MHz15B
400-406 MHz202.5ppm11K0F3E9EF
400-406 MHz202.5ppm7K60F1D9EF, ES
400-406 MHz202.5ppm7K60F1E9EF, ES
406.1-480 MHz202.5ppm11K0F3E9EF
406.1-480 MHz202.5ppm7K60F1D9EF, ES
406.1-480 MHz202.5ppm7K60F1E9EF, ES

Grants

TCB Grant - Application Nc/GFs+f+0mndEwxwk8CuA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 01/18/2022

Application Dated: 01/18/2022
Shenzhen Ysair Technology Co., LTD
6 / F, building 6, Yunli intelligent park, No. 3
Changfa, Middle Road, Yangmei community, Bantian
street, Longgang District, Shenzhen, Guangdong,
China
 
Attention: Weidong Shen

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3OORT73
Name of Grantee:  Shenzhen Ysair Technology Co., LTD
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mini Mobile Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 136.0  -  174.0 20.0 2.5  PM 11K0F3E
EF ES 90 136.0  -  174.0 20.0 2.5  PM 7K60F1D
EF ES 90 136.0  -  174.0 20.0 2.5  PM 7K60F1E
EF 90 400.0  -  406.0 20.0 2.5  PM 11K0F3E
EF 90 406.1  -  480.0 20.0 2.5  PM 11K0F3E
EF ES 90 400.0  -  406.0 20.0 2.5  PM 7K60F1D
EF ES 90 406.1  -  480.0 20.0 2.5  PM 7K60F1D
EF ES 90 400.0  -  406.0 20.0 2.5  PM 7K60F1E
EF ES 90 406.1  -  480.0 20.0 2.5  PM 7K60F1E

Output power listed is maximum rated conducted power at antenna port. The minimum output setting is 5 W. This transmitter must be restricted to work related operations in an Occupational/Controlled RF exposure environment, not exceeding a maximum transmitting duty factor of 50%. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50 cm from all persons. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.
ES: This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth.

EAS Grant - Application Nc/GFs+f+0mndEwxwk8CuA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Ysair Technology Co., LTD
6 / F, building 6, Yunli intelligent park, No. 3 Changfa, Middle Road, Yangmei community, Bantian
street, Longgang District, Shenzhen, Guangdong,
China
  Date of Grant: 01/18/2022

Application Dated: 01/18/2022
 
Attention: Weidong Shen

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3OORT73
Name of Grantee:  Shenzhen Ysair Technology Co., LTD
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mini Mobile Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 136.0  -  174.0 20.0 2.5  PM 11K0F3E
EF ES 90 136.0  -  174.0 20.0 2.5  PM 7K60F1D
EF ES 90 136.0  -  174.0 20.0 2.5  PM 7K60F1E
EF 90 400.0  -  406.0 20.0 2.5  PM 11K0F3E
EF 90 406.1  -  480.0 20.0 2.5  PM 11K0F3E
EF ES 90 400.0  -  406.0 20.0 2.5  PM 7K60F1D
EF ES 90 406.1  -  480.0 20.0 2.5  PM 7K60F1D
EF ES 90 400.0  -  406.0 20.0 2.5  PM 7K60F1E
EF ES 90 406.1  -  480.0 20.0 2.5  PM 7K60F1E

Output power listed is maximum rated conducted power at antenna port. The minimum output setting is 5 W. This transmitter must be restricted to work related operations in an Occupational/Controlled RF exposure environment, not exceeding a maximum transmitting duty factor of 50%. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50 cm from all persons. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.
ES: This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth.

TCB Grant - Application LhgWt5KjClkCQuJoBnpweQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 01/18/2022

Application Dated: 01/18/2022
Shenzhen Ysair Technology Co., LTD
6 / F, building 6, Yunli intelligent park, No. 3
Changfa, Middle Road, Yangmei community, Bantian
street, Longgang District, Shenzhen, Guangdong,
China
 
Attention: Weidong Shen

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3OORT73
Name of Grantee:  Shenzhen Ysair Technology Co., LTD
Equipment Class: Scanning Receiver
Notes: Mini Mobile Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B 136.0  -  174.0
15B 400.0  -  480.0


EAS Grant - Application LhgWt5KjClkCQuJoBnpweQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Ysair Technology Co., LTD
6 / F, building 6, Yunli intelligent park, No. 3 Changfa, Middle Road, Yangmei community, Bantian
street, Longgang District, Shenzhen, Guangdong,
China
  Date of Grant: 01/18/2022

Application Dated: 01/18/2022
 
Attention: Weidong Shen

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3OORT73
Name of Grantee:  Shenzhen Ysair Technology Co., LTD
Equipment Class: Scanning Receiver
Notes: Mini Mobile Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B 136.0  -  174.0
15B 400.0  -  480.0



Mail To: