FCC ID 2A3PR-KCA01

Air Purifier

by Kalado LLC

Grantee Code: 2A3PR   Product Code: KCA01
Latest application date: 2022-02-10

FCC ID Device Details

FCC ID2A3PR-KCA01
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A3PR
Product CodeKCA01
Applicant BusinessKalado LLC 🇺🇸
Related Domains apemans.com
Equipment ClassAir Purifier
Test FirmShenzhen HUAK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2022-02-10

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2022-02-10PDF 524.4 KB
Internal PhotosInternal Photos2022-02-10PDF 2.3 MB
External PhotosExternal Photos2022-02-10PDF 1.5 MB
LabelID Label/Location Info2022-02-10PDF 58.5 KB
Test Setup PhotosTest Setup Photos2022-02-10PDF 218.7 KB
Test ReportTest Report2022-02-10PDF 5.2 MB
Agent Authorization Rev 1.0Cover Letter(s)2022-02-10PDF 12.1 KB
FCC_Short Long Term Confidentiality RequestCover Letter(s)2022-02-10PDF 12.7 KB
Model DifferenceCover Letter(s)2022-02-10PDF 3.9 MB
MPERF Exposure Info2022-02-10PDF 37.9 KB
Block Metadata onlyBlock DiagramPDF 137.2 KB
SCH Metadata onlySchematicsPDF 216.3 KB
OP Metadata onlyOperational DescriptionPDF 79.8 KB

Application Information

Application IDL5I6Pg0SoHjXyxZTd8SkYw==
Final Action Date2022-02-10
Application PurposeOriginal Equipment
Applicant FRN0031649858
ModelKCA01
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionAir Purifier
Responsible PartyLI LI, lili@apemans.com , 13713811439
Technical ContactKalado LLC, lili@apemans.com
Test FirmJason Zhou, Shenzhen HUAK Testing Technology Co., Ltd., jason@cer-mark.com , +86-755-23029901
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
L5I6Pg0SoHjXyxZTd8SkYw==2022-02-10Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.0071315C
2412-2462 MHz0.041515C

Grants

TCB Grant - Application L5I6Pg0SoHjXyxZTd8SkYw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 02/10/2022

Application Dated: 02/10/2022
Kalado LLC
3120 139th Ave SE, 5th Floor,
Bellevue, WA 98005
 
Attention: LI LI

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3PR-KCA01
Name of Grantee:  Kalado LLC
Equipment Class: Digital Transmission System
Notes: Air Purifier
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00713  
15C 2412.0  -  2462.0 0.0415  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application L5I6Pg0SoHjXyxZTd8SkYw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kalado LLC
3120 139th Ave SE, 5th Floor,
Bellevue, WA 98005
United States
  Date of Grant: 02/10/2022

Application Dated: 02/10/2022
 
Attention: LI LI

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3PR-KCA01
Name of Grantee:  Kalado LLC
Equipment Class: Digital Transmission System
Notes: Air Purifier
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00713  
15C 2412.0  -  2462.0 0.0415  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.