FCC ID 2A3SYHHM004
Humidifier
by Hesung Innovation Limited
Grantee Code: 2A3SY Product Code: HHM004
Latest application date: 2024-06-13
FCC ID Device Details
| FCC ID | 2A3SYHHM004 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A3SY |
| Product Code | HHM004 |
| Applicant Business | Hesung Innovation Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | Humidifier |
| Test Firm | Shenzhen Huaxia Testing Technology Co., Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2024-06-13 |
| 2402-2480 MHz | Original Equipment | 2024-05-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2024-05-07 | PDF 2.7 MB |
| Internal Photos Metadata only | Internal Photos | 2024-06-13 | PDF 2.6 MB |
| Internal Photos | Internal Photos | 2024-06-13 | |
| Internal Photos | Internal Photos | 2024-05-07 | PDF 1.2 MB |
| External Photos | External Photos | 2024-05-07 | PDF 488.3 KB |
| Label and Location | ID Label/Location Info | 2024-05-07 | PDF 755.7 KB |
| Test Setup Photos | Test Setup Photos | 2024-05-07 | PDF 484.2 KB |
| Test Report1 | Test Report | 2024-06-13 | PDF 4.2 MB |
| Test Report2 | Test Report | 2024-06-13 | PDF 1.4 MB |
| Test Report BLE 1 | Test Report | 2024-05-07 | PDF 2.9 MB |
| Test Report BLE 2 | Test Report | 2024-05-07 | PDF 1.7 MB |
| Test Report WIFI 1 | Test Report | 2024-05-07 | PDF 5.5 MB |
| Test Report WIFI 2 | Test Report | 2024-05-07 | PDF 628.6 KB |
| Agent letter | Attestation Statements | 2024-06-13 | PDF 131.3 KB |
| Attestation of Cover List | Attestation Statements | 2024-06-13 | PDF 96.4 KB |
| Agent Authorization Letter Template | Cover Letter(s) | 2024-06-13 | PDF 122.5 KB |
| FCC Class II PC request letter | Cover Letter(s) | 2024-06-13 | PDF 191.7 KB |
| FCC Short Long Term Confidentiality Request | Cover Letter(s) | 2024-06-13 | PDF 54.7 KB |
| Model difference | Cover Letter(s) | 2024-06-13 | PDF 64.5 KB |
| Antenna Report | Cover Letter(s) | 2024-05-07 | PDF 2.3 MB |
| RF Exposure | RF Exposure Info | 2024-06-13 | PDF 307.9 KB |
| RF Exposure Metadata only | RF Exposure Info | 2024-06-13 | PDF 4.2 MB |
| RF Exposure | RF Exposure Info | 2024-05-07 | PDF 307.8 KB |
| BlockDiagram Metadata only | Block Diagram | PDF 21.3 KB | |
| Schematics Metadata only | Schematics | PDF 327.5 KB | |
| OperatingDescription Metadata only | Operational Description | PDF 96.1 KB |
Application Information
| Application ID | eDXKSD1mP31kvRjn78WKww== |
|---|---|
| Final Action Date | 2024-06-13 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0031685647 |
| Model | HHM004 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Humidifier |
| Responsible Party | Bera Yang, bera.yang@hesung.com |
| Technical Contact | Hesung Innovation Limited, bera.yang@hesung.com |
| Test Firm | Jack Ai, Shenzhen Huaxia Testing Technology Co., Ltd, szcqa@cqa-cert.com |
| TCB Email | anezam@qai.org |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | C2PC. 1.Move the EC7,C16,C6,C5,C7 and R1 2. Add the reed switch. Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| eDXKSD1mP31kvRjn78WKww== | 2024-06-13 | Class II permissive change or modification of presently authorized equipment |
| 3l87DDhVKUET1LsWph5v9w== | 2024-05-07 | Original Equipment |
Grants
TCB Grant - Application eDXKSD1mP31kvRjn78WKww==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 06/13/2024 Application Dated: 06/07/2024 |
| Hesung Innovation Limited |
| Room 803, Chevalier House, |
| 45-51 Chatham Road South, Tsim Sha Tsui, Kowloon |
| Hong Kong, 999077 China |
| Attention: Bera Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3SYHHM004 |
| Name of Grantee: | Hesung Innovation Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Humidifier |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0009 | |||
| 15C | 2412.0 - 2462.0 | 0.0123 |
| C2PC. 1.Move the EC7,C16,C6,C5,C7 and R1 2. Add the reed switch. Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
EAS Grant - Application eDXKSD1mP31kvRjn78WKww==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hesung Innovation Limited Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, Kowloon Hong Kong, 999077 China |
Date of Grant: 06/13/2024 Application Dated: 06/07/2024 |
| Attention: Bera Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3SYHHM004 |
| Name of Grantee: | Hesung Innovation Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Humidifier |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0009 | |||
| 15C | 2412.0 - 2462.0 | 0.0123 |
| C2PC. 1.Move the EC7,C16,C6,C5,C7 and R1 2. Add the reed switch. Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 05/07/2024 Application Dated: 05/06/2024 |
| Hesung Innovation Limited |
| Room 803, Chevalier House, |
| 45-51 Chatham Road South, Tsim Sha Tsui, Kowloon |
| Hong Kong, 999077 China |
| Attention: Bera Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3SYHHM004 |
| Name of Grantee: | Hesung Innovation Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Humidifier |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0009 | |||
| 15C | 2412.0 - 2462.0 | 0.0123 |
| Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
EAS Grant - Application 3l87DDhVKUET1LsWph5v9w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hesung Innovation Limited Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, Kowloon Hong Kong, 999077 China |
Date of Grant: 05/07/2024 Application Dated: 05/06/2024 |
| Attention: Bera Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3SYHHM004 |
| Name of Grantee: | Hesung Innovation Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Humidifier |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0009 | |||
| 15C | 2412.0 - 2462.0 | 0.0123 |
| Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |