FCC ID 2A3SYHSH009S

Smart Wall-mounted Heater

by Hesung Innovation Limited

Grantee Code: 2A3SY   Product Code: HSH009S
Latest application date: 2024-07-09

FCC ID Device Details

FCC ID2A3SYHSH009S
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A3SY
Product CodeHSH009S
Applicant BusinessHesung Innovation Limited 🇨🇳
Related Domains hesung.com
Equipment ClassSmart Wall-mounted Heater
Test FirmShenzhen Huaxia Testing Technology Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2024-07-09

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2024-07-09PDF 3.8 MB
Internal PhotosInternal Photos2024-07-09PDF 4.1 MB
External PhotosExternal Photos2024-07-09PDF 2.3 MB
Label LocationID Label/Location Info2024-07-09PDF 1.9 MB
Test Setup PhotosTest Setup Photos2024-07-09PDF 1.4 MB
Test Report1Test Report2024-07-09PDF 4.7 MB
Test Report2Test Report2024-07-09PDF 4.2 MB
Test Report3Test Report2024-07-09PDF 5.4 MB
Test Report4Test Report2024-07-09PDF 1.6 MB
Attestation of Cover ListAttestation Statements2024-07-09PDF 96.1 KB
U.S. Agent Letter of AttestationAttestation Statements2024-07-09PDF 131.6 KB
ANTCover Letter(s)2024-07-09PDF 2.2 MB
Agent Authorization Letter TemplateCover Letter(s)2024-07-09PDF 122.7 KB
FCC Short & Long Term Confidentiality RequestCover Letter(s)2024-07-09PDF 54.9 KB
Model DifferenceCover Letter(s)2024-07-09PDF 65 KB
RF ExposureRF Exposure Info2024-07-09PDF 308.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 119.6 KB
Schematics Metadata onlySchematicsPDF 345.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 117.7 KB

Application Information

Application IDlY+u9RImpVWHPskSm5SvEw==
Final Action Date2024-07-09
Application PurposeOriginal Equipment
Applicant FRN0031685647
ModelHSH009S
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Wall-mounted Heater
Responsible PartyBera Yang, bera.yang@hesung.com , +86-13826971634
Technical ContactHesung Innovation Limited, bera.yang@hesung.com
Test FirmJack Ai, Shenzhen Huaxia Testing Technology Co., Ltd, szcqa@cqa-cert.com , +8613902988375
TCB Emailanezam@qai.org
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
lY+u9RImpVWHPskSm5SvEw==2024-07-09Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000715C
2412-2462 MHz0.009715C

Grants

TCB Grant - Application lY+u9RImpVWHPskSm5SvEw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 07/09/2024

Application Dated: 07/08/2024
Hesung Innovation Limited
Room 803, Chevalier House,
45-51 Chatham Road South, Tsim Sha Tsui, Kowloon
Hong Kong, 999077
China
 
Attention: Bera Yang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3SYHSH009S
Name of Grantee:  Hesung Innovation Limited
Equipment Class: Digital Transmission System
Notes: Smart Wall-mounted Heater
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0007  
15C 2412.0  -  2462.0 0.0097  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application lY+u9RImpVWHPskSm5SvEw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hesung Innovation Limited
Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, Kowloon
Hong Kong, 999077
China
  Date of Grant: 07/09/2024

Application Dated: 07/08/2024
 
Attention: Bera Yang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A3SYHSH009S
Name of Grantee:  Hesung Innovation Limited
Equipment Class: Digital Transmission System
Notes: Smart Wall-mounted Heater
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0007  
15C 2412.0  -  2462.0 0.0097  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: