FCC ID 2A3YB-YS-R1PLUS
YESOUL ROWING MACHINE
by FUJIAN YESOUL HEALTH TECHNOLOGY CO.,LTD
Grantee Code: 2A3YB Product Code: YSR1PLUS
Latest application date: 2025-04-25
FCC ID Device Details
| FCC ID | 2A3YB-YS-R1PLUS |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A3YB |
| Product Code | YSR1PLUS |
| Applicant Business | FUJIAN YESOUL HEALTH TECHNOLOGY CO.,LTD 🇨🇳 |
| Related Domains | |
| Equipment Class | YESOUL ROWING MACHINE |
| Test Firm | Bay Area Compliance Laboratories Corp.(Xiamen) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2025-04-25 |
| 2412-2462 MHz | Original Equipment | 2025-04-25 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2025-04-25 | PDF 3.2 MB |
| Internal Photos Part 1 | Internal Photos | 2025-04-25 | PDF 4.9 MB |
| Internal Photos Part 2 | Internal Photos | 2025-04-25 | PDF 1.1 MB |
| External Photos | External Photos | 2025-04-25 | PDF 516.9 KB |
| Label & Label Location | ID Label/Location Info | 2025-04-25 | PDF 2.2 MB |
| Test Setup Photos | Test Setup Photos | 2025-04-25 | PDF 1.4 MB |
| Antenna Specification | Test Report | 2025-04-25 | PDF 496.1 KB |
| Test Report - BLE | Test Report | 2025-04-25 | PDF 3.8 MB |
| Test Report - Wi-Fi Part 1 | Test Report | 2025-04-25 | PDF 5 MB |
| Test Report - Wi-Fi Part 2 | Test Report | 2025-04-25 | PDF 2.8 MB |
| Test Report Part 1 | Test Report | 2025-04-25 | PDF 5.1 MB |
| Test Report Part 2 | Test Report | 2025-04-25 | PDF 1.4 MB |
| 2.911 (d)(5)(i)(ii) Attestation Statement | Attestation Statements | 2025-04-25 | PDF 206.4 KB |
| Attestation Letter | Attestation Statements | 2025-04-25 | PDF 93.4 KB |
| US Agent Attestation Letter | Attestation Statements | 2025-04-25 | PDF 64.6 KB |
| FCC Agent Authorization Letter | Cover Letter(s) | 2025-04-25 | PDF 57.1 KB |
| FCC Long-term Confidential Request | Cover Letter(s) | 2025-04-25 | PDF 72.9 KB |
| RF Exposure | RF Exposure Info | 2025-04-25 | PDF 319.5 KB |
| Block Diagram Metadata only | Block Diagram | PDF 585.4 KB | |
| Schematics Metadata only | Schematics | PDF 2 MB | |
| Operation Description Metadata only | Operational Description | PDF 82.3 KB |
Application Information
| Application ID | Ii93f1zPxa4vJsa37U9tkA== |
|---|---|
| Final Action Date | 2025-04-25 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0031739345 |
| Model | YS-R1PLUS |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | YESOUL ROWING MACHINE |
| Responsible Party | Wenbin Hong, Channel Director, wenbinhong@yesoulchina.com |
| Test Firm | Mike Tu, Bay Area Compliance Laboratories Corp.(Xiamen), qa.xm@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Ii93f1zPxa4vJsa37U9tkA== | 2025-04-25 | Original Equipment |
| +c967JUQ77qB0EEaOI1E/Q== | 2025-04-25 | Original Equipment |
Equipment Authorization
| Frequency | Output |
|---|---|
| 2402-2480 MHz | 0.0040000 |
| 2402-2480 MHz | 0.0009 |
| 2412-2462 MHz | 0.068 |
Grants
TCB Grant - Application Ii93f1zPxa4vJsa37U9tkA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 04/25/2025 Application Dated: 04/25/2025 |
| FUJIAN YESOUL HEALTH TECHNOLOGY CO.,LTD |
| RM-B616, BLDG., NO.1, STRAIT ECONOMIC AND TRADE |
| PLAZA, FUZHOU FREE TRADE ZONE |
| FUZHOU, FUJIAN, 350000 China |
| Attention: Wenbin Hong , Channel Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3YB-YS-R1PLUS |
| Name of Grantee: | FUJIAN YESOUL HEALTH TECHNOLOGY CO.,LTD |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | YESOUL ROWING MACHINE |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.004 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
TCB Grant - Application +c967JUQ77qB0EEaOI1E/Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 04/25/2025 Application Dated: 04/25/2025 |
| FUJIAN YESOUL HEALTH TECHNOLOGY CO.,LTD |
| RM-B616, BLDG., NO.1, STRAIT ECONOMIC AND TRADE |
| PLAZA, FUZHOU FREE TRADE ZONE |
| FUZHOU, FUJIAN, 350000 China |
| Attention: Wenbin Hong , Channel Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A3YB-YS-R1PLUS |
| Name of Grantee: | FUJIAN YESOUL HEALTH TECHNOLOGY CO.,LTD |
| Equipment Class: | Digital Transmission System |
| Notes: | YESOUL ROWING MACHINE |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0009 | |||
| 15C | 2412.0 - 2462.0 | 0.068 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes. |