FCC ID 2A6CS-ES600Z

Sound and Light Siren

by INNOPRO TECHNOLOGY CO., LTD.

Grantee Code: 2A6CS   Product Code: ES600Z
Latest application date: 2022-04-27

FCC ID Device Details

FCC ID2A6CS-ES600Z
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A6CS
Product CodeES600Z
Applicant BusinessINNOPRO TECHNOLOGY CO., LTD. 🇨🇳
Equipment ClassSound and Light Siren
Test FirmShenzhen HUAK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2475 MHzOriginal Equipment2022-04-27

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2022-04-27PDF 1.4 MB
Int photoInternal Photos2022-04-27PDF 2.6 MB
Ext photoExternal Photos2022-04-27PDF 2.5 MB
labelID Label/Location Info2022-04-27PDF 81.2 KB
test photoTest Setup Photos2022-04-27PDF 216.7 KB
Test reportTest Report2022-04-27PDF 3 MB
Agent_AuthorizationCover Letter(s)2022-04-27PDF 17.2 KB
FCC_Long_Term_Confidentiality_RequestCover Letter(s)2022-04-27PDF 17.5 KB
Model differenceCover Letter(s)2022-04-27PDF 4.3 MB
MPE reportRF Exposure Info2022-04-27PDF 16.8 KB
Block Metadata onlyBlock DiagramPDF 78.4 KB
SCH Metadata onlySchematicsPDF 69.2 KB
Operational Description Metadata onlyOperational DescriptionPDF 80.5 KB

Application Information

Application IDJBvd3XlNpX5CVmR5uPYs6g==
Final Action Date2022-04-27
Application PurposeOriginal Equipment
Applicant FRN0032239428
ModelES600Z
Frequency Range2405-2475 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSound and Light Siren
Responsible PartyLizhi Pan, 182312470@qq.com , 13189709310
Technical ContactINNOPRO TECHNOLOGY CO., LTD., 182312470@qq.com
Test FirmJason Zhou, Shenzhen HUAK Testing Technology Co., Ltd., jason@cer-mark.com , +86-755-23029901
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
JBvd3XlNpX5CVmR5uPYs6g==2022-04-27Original Equipment

Equipment Authorization

FrequencyOutputRules
2405-2475 MHz0.000390015C

Grants

TCB Grant - Application JBvd3XlNpX5CVmR5uPYs6g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/27/2022

Application Dated: 04/27/2022
INNOPRO TECHNOLOGY CO., LTD.
33 Dahe Industrial Zone,Guancheng Community,
Guanhu Street,Longhua District,
Shenzhen,
China
 
Attention: Lizhi Pan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A6CS-ES600Z
Name of Grantee:  INNOPRO TECHNOLOGY CO., LTD.
Equipment Class: Digital Transmission System
Notes: Sound and Light Siren
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.00039  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application JBvd3XlNpX5CVmR5uPYs6g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

INNOPRO TECHNOLOGY CO., LTD.
33 Dahe Industrial Zone,Guancheng Community, Guanhu Street,Longhua District,
Shenzhen,
China
  Date of Grant: 04/27/2022

Application Dated: 04/27/2022
 
Attention: Lizhi Pan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A6CS-ES600Z
Name of Grantee:  INNOPRO TECHNOLOGY CO., LTD.
Equipment Class: Digital Transmission System
Notes: Sound and Light Siren
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.00039  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: