FCC ID 2A6LA-J9

Mini Mobile Phone

by ShenZhen Chang Zhong Technology CO.,LTD

Grantee Code: 2A6LA   Product Code: J9
Latest application date: 2022-05-25

FCC ID Device Details

FCC ID2A6LA-J9
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A6LA
Product CodeJ9
Applicant BusinessShenZhen Chang Zhong Technology CO.,LTD 🇨🇳
Equipment ClassMini Mobile Phone
Test FirmShenzhen LCS Compliance Testing Laboratory Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2022-05-25
824.2-848.8 MHzOriginal Equipment2022-05-25

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2022-05-25PDF 1.5 MB
Internal PhotosInternal Photos2022-05-25PDF 1.5 MB
External PhotosExternal Photos2022-05-25PDF 890.5 KB
Label LocationID Label/Location Info2022-05-25PDF 366.3 KB
Label and locationID Label/Location Info2022-05-25PDF 366.3 KB
Test Setup PhotosTest Setup Photos2022-05-25PDF 541.2 KB
Test setup photoTest Setup Photos2022-05-25PDF 420.8 KB
Test setup photoTest Setup Photos2022-05-25PDF 490 KB
Test ReportTest Report2022-05-25PDF 4.2 MB
Test ReportTest Report2022-05-25PDF 2.9 MB
Test Report SARRF Exposure Info2022-05-25PDF 3.7 MB
Agent Authorization LetterCover Letter(s)2022-05-25PDF 15.3 KB
Agent Authorization Rev 1.0Cover Letter(s)2022-05-25PDF 15.3 KB
Declaration on Model DifferencesCover Letter(s)2022-05-25PDF 82.2 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2022-05-25PDF 71.4 KB
BlockDiagram Metadata onlyBlock DiagramPDF 96.6 KB
SCH Metadata onlySchematicsPDF 139.9 KB
Schematic Metadata onlySchematicsPDF 139.9 KB
OP Metadata onlyOperational DescriptionPDF 72.5 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 1.7 MB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 70.3 KB

Application Information

Application IDgwY+fvkouenRQSNF3Vdv2Q==
Final Action Date2022-05-25
Application PurposeOriginal Equipment
Applicant FRN0032296550
ModelJ9
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionMini Mobile Phone
Responsible PartyLily Huang, manager, huang_liqin@126.com , 0755-23300054
Technical ContactShenZhen Chang Zhong Technology CO.,LTD, huang_liqin@126.com
Test FirmGavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com , 0755-82591330
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.05W/kg, 0.03W/kg and 0.71W/kg respectively.

Applications

Application IDDatePurpose
gwY+fvkouenRQSNF3Vdv2Q==2022-05-25Original Equipment
AnlsF38bOuhZKNjhLh4Whg==2022-05-25Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.9442.5ppm246KGXW22H
1850.2-1909.8 MHz0.6242.5ppm243KGXW24E
2402-2480 MHz0.001000015C

Grants

TCB Grant - Application gwY+fvkouenRQSNF3Vdv2Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/25/2022

Application Dated: 05/25/2022
ShenZhen Chang Zhong Technology CO.,LTD
Five Floor, First Building Of LiLin Industrial
Area,Baihua Community,Guangming Streets,
Guangming District,ShenZhen, 518107
China
 
Attention: Lily Huang , manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A6LA-J9
Name of Grantee:  ShenZhen Chang Zhong Technology CO.,LTD
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mini Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.001  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.05W/kg, 0.03W/kg and 0.71W/kg respectively.

EAS Grant - Application gwY+fvkouenRQSNF3Vdv2Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ShenZhen Chang Zhong Technology CO.,LTD
Five Floor, First Building Of LiLin Industrial Area,Baihua Community,Guangming Streets,
Guangming District,ShenZhen, 518107
China
  Date of Grant: 05/25/2022

Application Dated: 05/25/2022
 
Attention: Lily Huang , manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A6LA-J9
Name of Grantee:  ShenZhen Chang Zhong Technology CO.,LTD
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mini Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.001  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.05W/kg, 0.03W/kg and 0.71W/kg respectively.



TCB Grant - Application AnlsF38bOuhZKNjhLh4Whg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/25/2022

Application Dated: 05/25/2022
ShenZhen Chang Zhong Technology CO.,LTD
Five Floor, First Building Of LiLin Industrial
Area,Baihua Community,Guangming Streets,
Guangming District,ShenZhen, 518107
China
 
Attention: Lily Huang , manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A6LA-J9
Name of Grantee:  ShenZhen Chang Zhong Technology CO.,LTD
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mini Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.624 2.5  PM 243KGXW
22H 824.2  -  848.8 0.944 2.5  PM 246KGXW

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.66W/kg, 0.65W/kg and 0.71W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

EAS Grant - Application AnlsF38bOuhZKNjhLh4Whg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ShenZhen Chang Zhong Technology CO.,LTD
Five Floor, First Building Of LiLin Industrial Area,Baihua Community,Guangming Streets,
Guangming District,ShenZhen, 518107
China
  Date of Grant: 05/25/2022

Application Dated: 05/25/2022
 
Attention: Lily Huang , manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A6LA-J9
Name of Grantee:  ShenZhen Chang Zhong Technology CO.,LTD
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mini Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.624 2.5  PM 243KGXW
22H 824.2  -  848.8 0.944 2.5  PM 246KGXW

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.66W/kg, 0.65W/kg and 0.71W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.



Mail To: