FCC ID 2A77600001

Wireless/ Wired X-Ray Flat Panel Detectors

by Allengers Medical Systems Limited

Grantee Code: 2A776   Product Code: 00001
Latest application date: 2022-09-23

FCC ID Device Details

FCC ID2A77600001
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A776
Product Code00001
Applicant BusinessAllengers Medical Systems Limited 🇮🇳
Related Domains allengers.net dekra.com
Equipment ClassWireless/ Wired X-Ray Flat Panel Detectors
Test FirmDEKRA TESTING AND CERTIFICATION CO., LTD. LinKou

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2022-09-23
2422-2462 MHzClass II permissive change or modification of presently authorized equipment2022-09-23
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: PD98265NG Grant Date: 06/03/20162022-09-07
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: PD98265NG Grant Date: 06/03/20162022-09-07
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: PD98265NG Grant Date: 06/03/20162022-09-07
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AS4N000001 Grant Date: 06/17/20192022-09-01
2422-2462 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AS4N000001 Grant Date: 06/17/20192022-09-01

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2022-09-23PDF 4.4 MB
Internal PhotosInternal Photos2022-09-23PDF 1.1 MB
External PhotosExternal Photos2023-02-27PDF 759.7 KB
External PhotosExternal Photos2022-09-23PDF 1.9 MB
External PhotosExternal Photos2022-09-07PDF 1.8 MB
ID LabelID Label/Location Info2022-09-23PDF 85.8 KB
Label Location InfoID Label/Location Info2022-09-23PDF 311.4 KB
Label sampleID Label/Location Info2022-09-07PDF 82.5 KB
LabelLocID Label/Location Info2022-09-07PDF 81.1 KB
ID Label/Location InfoID Label/Location Info2022-09-01PDF 97.9 KB
Test Setup Photos_RFTest Setup Photos2022-09-23PDF 826 KB
Test Setup Photos_SARTest Setup Photos2022-09-23PDF 2.3 MB
PC142.54.0300A SpecificationTest Report2022-09-23PDF 687.9 KB
PC142.54.0500A SpecificationTest Report2022-09-23PDF 701.1 KB
Test Report_DTSTest Report2022-09-23PDF 3.1 MB
Test Report_NII_Part 1Test Report2022-09-23PDF 5 MB
Test Report_NII_Part 2Test Report2022-09-23PDF 3.6 MB
Test Report_SARRF Exposure Info2022-09-23PDF 4.3 MB
ATTESTATIONCover Letter(s)2022-09-07PDF 175.4 KB
Declaration of authorizationCover Letter(s)2022-09-23PDF 199.7 KB
FCC Class II permissive change letterCover Letter(s)2022-09-23PDF 239.9 KB
confidentialityCover Letter(s)2022-09-23PDF 259.6 KB
Declaration letter for electrically identicalCover Letter(s)2022-09-07PDF 229.1 KB
Declaration of authorizationCover Letter(s)2022-09-07PDF 195.6 KB
FCC Auth Ltr Change of IDCover Letter(s)2022-09-07PDF 87.1 KB
FCC Auth Ltr for Change of IDCover Letter(s)2022-09-01PDF 203.7 KB
FCC Auth Ltr for Change of ID signedCover Letter(s)2022-09-01PDF 181.6 KB
POA_LetterCover Letter(s)2022-09-01PDF 218.8 KB
Request for LT or STC confidentialityCover Letter(s)2022-09-01PDF 118.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 390.6 KB
Schematics Metadata onlySchematicsPDF 4.5 MB
Operational Description Metadata onlyOperational DescriptionPDF 262.2 KB
Operational Description Metadata onlyOperational DescriptionPDF 263.2 KB
SAR mode_ kdb Inquiry 571642 Metadata onlyOperational DescriptionPDF 50.9 KB

Application Information

Application IDuG4mUa74ysAphtXjmqY49g==
Final Action Date2022-09-23
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0032727349
Model00001
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionWireless/ Wired X-Ray Flat Panel Detectors
Responsible PartySanjeev Kumar Marjara, ra.fdaindia@allengers.net , +919872980168
AgentCoco Coco Coco, DEKRA Testing and Certification Co., Ltd., coco.pong@dekra.com , +886286013788
Technical ContactCoco Pong, DEKRA Testing and Certification Co., Ltd., coco.pong@dekra.com , +886286013788
Non-Technical ContactCoco Pong, DEKRA Testing and Certification Co., Ltd., coco.pong@dekra.com , +886286013788
Test FirmMirenda Liao, DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou, mirenda.liao@dekra.com , +886-2-2602-7968
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass II permissive change: The changes applies to a) RF exposure change into the specific host(s), Allengers, G4343RWG, G4343RWC, b) antenna with different type c) output power decreases via software, as described in this filing. The highest reported SAR for body, product specific (10g), and simultaneous transmission use condition are 0.77W/kg, 1.33W/kg, and 2.98W/kg (10g), respectively. Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. Device is a client only device with enabled for 5GHz band operations and also has 20MHz, 40MHz and80MHz bandwidth modes as described in this filing. This device must utilize the BIOS Locking features as documented in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.75W/kg and 1.44W/kg respectively.

Applications

Application IDDatePurpose
uG4mUa74ysAphtXjmqY49g==2022-09-23Class II permissive change or modification of presently authorized equipment
tZUg/B47hxZYwi6o6jUxoQ==2022-09-23Class II permissive change or modification of presently authorized equipment
oeSOGM7tDKAdkadRygh9nQ==2022-09-07Change in identification of presently authorized equipment. Original FCC ID: PD98265NG Grant Date: 06/03/2016
i0OPYLXz8eXNbgOwqwNQDg==2022-09-07Change in identification of presently authorized equipment. Original FCC ID: PD98265NG Grant Date: 06/03/2016
LQ09OXV9Ug2RMvJZpq6fTg==2022-09-07Change in identification of presently authorized equipment. Original FCC ID: PD98265NG Grant Date: 06/03/2016
AM9OIS6W1DLOLmAfS8zIwg==2022-09-07Change in identification of presently authorized equipment. Original FCC ID: PD98265NG Grant Date: 06/03/2016
jXObLWx7by+J+1GmMmdinA==2022-09-01Change in identification of presently authorized equipment. Original FCC ID: 2AS4N000001 Grant Date: 06/17/2019
Ue0sIvQHyYaIClrH4RuS8A==2022-09-01Change in identification of presently authorized equipment. Original FCC ID: 2AS4N000001 Grant Date: 06/17/2019

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.016000015CCC
2402-2480 MHz0.00815CCC
2412-2472 MHz115CCC, MO
2422-2462 MHz0.49415CCC, MO
5190-5230 MHz0.15315ECC, MO
5210 MHz0.02115ECC, MO
5260-5320 MHz0.15915ECC, MO, ND
5270-5310 MHz0.16615ECC, MO, ND
5290 MHz0.02715ECC, MO, ND
5500-5700 MHz0.10815ECC, MO, ND
5510-5670 MHz0.11915ECC, MO, ND
5530-5690 MHz0.10715ECC, MO, ND
5710 MHz0.21515ECC, MO, ND
5720 MHz0.13315ECC, MO, ND
5745-5825 MHz0.22715ECC, MO
5755-5795 MHz0.22715ECC, MO
5775 MHz0.09215ECC, MO

Grants

TCB Grant - Application uG4mUa74ysAphtXjmqY49g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/23/2022

Application Dated: 09/22/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.161  
CC MO 15E 5190.0  -  5230.0 0.153  
CC MO 15E 5210.0  -  5210.0 0.021  
CC MO ND 15E 5260.0  -  5320.0 0.159  
CC MO ND 15E 5270.0  -  5310.0 0.166  
CC MO ND 15E 5290.0  -  5290.0 0.027  
CC MO ND 15E 5500.0  -  5700.0 0.108  
CC MO ND 15E 5510.0  -  5670.0 0.119  
CC MO ND 15E 5710.0  -  5710.0 0.215  
CC MO ND 15E 5720.0  -  5720.0 0.133  
CC MO ND 15E 5530.0  -  5690.0 0.107  
CC MO 15E 5745.0  -  5825.0 0.227  
CC MO 15E 5755.0  -  5795.0 0.227  
CC MO 15E 5775.0  -  5775.0 0.092  

Class II permissive change: The changes applies to a) RF exposure change into the specific host(s), Allengers, G4343RWG, G4343RWC, b) antenna with different type c) output power decreases via software, as described in this filing. The highest reported SAR for body, product specific (10g), and simultaneous transmission use condition are 0.77W/kg, 1.33W/kg, and 2.98W/kg (10g), respectively.

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. Device is a client only device with enabled for 5GHz band operations and also has 20MHz, 40MHz and80MHz bandwidth modes as described in this filing. This device must utilize the BIOS Locking features as documented in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.75W/kg and 1.44W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application uG4mUa74ysAphtXjmqY49g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/23/2022

Application Dated: 09/22/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.161  
CC MO 15E 5190.0  -  5230.0 0.153  
CC MO 15E 5210.0  -  5210.0 0.021  
CC MO ND 15E 5260.0  -  5320.0 0.159  
CC MO ND 15E 5270.0  -  5310.0 0.166  
CC MO ND 15E 5290.0  -  5290.0 0.027  
CC MO ND 15E 5500.0  -  5700.0 0.108  
CC MO ND 15E 5510.0  -  5670.0 0.119  
CC MO ND 15E 5710.0  -  5710.0 0.215  
CC MO ND 15E 5720.0  -  5720.0 0.133  
CC MO ND 15E 5530.0  -  5690.0 0.107  
CC MO 15E 5745.0  -  5825.0 0.227  
CC MO 15E 5755.0  -  5795.0 0.227  
CC MO 15E 5775.0  -  5775.0 0.092  

Class II permissive change: The changes applies to a) RF exposure change into the specific host(s), Allengers, G4343RWG, G4343RWC, b) antenna with different type c) output power decreases via software, as described in this filing. The highest reported SAR for body, product specific (10g), and simultaneous transmission use condition are 0.77W/kg, 1.33W/kg, and 2.98W/kg (10g), respectively.

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. Device is a client only device with enabled for 5GHz band operations and also has 20MHz, 40MHz and80MHz bandwidth modes as described in this filing. This device must utilize the BIOS Locking features as documented in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.75W/kg and 1.44W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application Ue0sIvQHyYaIClrH4RuS8A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/01/2022

Application Dated: 08/30/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Wireless/ Wired X-Ray Flat Panel Dete
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2472.0 1.0  
CC MO 15C 2422.0  -  2462.0 0.494  

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device enabled for 2.4 GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product.

The highest reported SAR values are Body and Simultaneous SAR are 0.46W/kg and 0.91W/kg respectively. 


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application Ue0sIvQHyYaIClrH4RuS8A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/01/2022

Application Dated: 08/30/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Wireless/ Wired X-Ray Flat Panel Dete
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2472.0 1.0  
CC MO 15C 2422.0  -  2462.0 0.494  

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device enabled for 2.4 GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product.

The highest reported SAR values are Body and Simultaneous SAR are 0.46W/kg and 0.91W/kg respectively. 


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application tZUg/B47hxZYwi6o6jUxoQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/23/2022

Application Dated: 09/22/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.008  
CC MO 15C 2412.0  -  2472.0 1.0  
CC MO 15C 2422.0  -  2462.0 0.494  

Class II permissive change: The changes applies to a) RF exposure change into the specific host(s), Allengers, G4343RWG, G4343RWC, b) antenna with different type c) modulation disabling via the software, as described in this filing. The highest reported SAR for body, product specific (10g), and simultaneous transmission use condition are 0.22W/kg, 0.36W/kg, and 0.70W/kg (10g), respectively.

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device enabled for2.4 GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. This device must utilize the BIOS Locking features as documented in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported SAR values are Body and Simultaneous SAR are 0.46W/kg and 0.91W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application tZUg/B47hxZYwi6o6jUxoQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/23/2022

Application Dated: 09/22/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.008  
CC MO 15C 2412.0  -  2472.0 1.0  
CC MO 15C 2422.0  -  2462.0 0.494  

Class II permissive change: The changes applies to a) RF exposure change into the specific host(s), Allengers, G4343RWG, G4343RWC, b) antenna with different type c) modulation disabling via the software, as described in this filing. The highest reported SAR for body, product specific (10g), and simultaneous transmission use condition are 0.22W/kg, 0.36W/kg, and 0.70W/kg (10g), respectively.

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device enabled for2.4 GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. This device must utilize the BIOS Locking features as documented in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported SAR values are Body and Simultaneous SAR are 0.46W/kg and 0.91W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application oeSOGM7tDKAdkadRygh9nQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/07/2022

Application Dated: 09/06/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.008  
CC MO 15C 2412.0  -  2472.0 1.0  
CC MO 15C 2422.0  -  2462.0 0.494  

Power Output listed is conducted. Modular Approval. The antenna(s) used for thistransmitter must not transmit simultaneously with any other antenna or transmitter, exceptin accordance with FCC multi-transmitter product procedures. Grantee must provideinstallation and operating instructions for complying with FCC multi-transmitter productprocedures. This module is approved in mobile/portable configurations. Only thoseantenna(s) tested with the device or similar antenna(s) with equal or lesser gain may beused with this transmitter. Grantee must coordinate with OEM integrator to determineapplicable host configurations to ensure RF exposure compliance, including simultaneoustransmission SAR requirements according to published KDB 616217 Supplementdocumentation. When all conditions of this filing cannot be met installation of this deviceinto specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. OEM/Hostintegrator must be provided with antenna installation instructions and transmitter operatingconditions to satisfy RF exposure compliance. Device is a client only device enabled for2.4 GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes asdescribed in this filing. This device must utilize the BIOS Locking features as documentedin this filing. OEM/Host integrator is responsible for complying with the instructions andrequirements for each transmitter they choose to integrate into a host product. The highestreported SAR values are Body and Simultaneous SAR are 0.46W/kg and 0.91W/kgrespectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application oeSOGM7tDKAdkadRygh9nQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/07/2022

Application Dated: 09/06/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.008  
CC MO 15C 2412.0  -  2472.0 1.0  
CC MO 15C 2422.0  -  2462.0 0.494  

Power Output listed is conducted. Modular Approval. The antenna(s) used for thistransmitter must not transmit simultaneously with any other antenna or transmitter, exceptin accordance with FCC multi-transmitter product procedures. Grantee must provideinstallation and operating instructions for complying with FCC multi-transmitter productprocedures. This module is approved in mobile/portable configurations. Only thoseantenna(s) tested with the device or similar antenna(s) with equal or lesser gain may beused with this transmitter. Grantee must coordinate with OEM integrator to determineapplicable host configurations to ensure RF exposure compliance, including simultaneoustransmission SAR requirements according to published KDB 616217 Supplementdocumentation. When all conditions of this filing cannot be met installation of this deviceinto specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. OEM/Hostintegrator must be provided with antenna installation instructions and transmitter operatingconditions to satisfy RF exposure compliance. Device is a client only device enabled for2.4 GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes asdescribed in this filing. This device must utilize the BIOS Locking features as documentedin this filing. OEM/Host integrator is responsible for complying with the instructions andrequirements for each transmitter they choose to integrate into a host product. The highestreported SAR values are Body and Simultaneous SAR are 0.46W/kg and 0.91W/kgrespectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application LQ09OXV9Ug2RMvJZpq6fTg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/07/2022

Application Dated: 09/06/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.161  
CC MO 15E 5190.0  -  5230.0 0.153  
CC MO 15E 5210.0  -  5210.0 0.021  
CC MO ND 15E 5260.0  -  5320.0 0.159  
CC MO ND 15E 5270.0  -  5310.0 0.166  
CC MO ND 15E 5290.0  -  5290.0 0.027  
CC MO ND 15E 5500.0  -  5700.0 0.108  
CC MO ND 15E 5510.0  -  5670.0 0.119  
CC MO ND 15E 5710.0  -  5710.0 0.215  
CC MO ND 15E 5720.0  -  5720.0 0.133  
CC MO ND 15E 5530.0  -  5690.0 0.107  
CC MO 15E 5745.0  -  5825.0 0.227  
CC MO 15E 5755.0  -  5795.0 0.227  
CC MO 15E 5775.0  -  5775.0 0.092  

Power Output listed is conducted. Modular Approval. The antenna(s) used for thistransmitter must not transmit simultaneously with any other antenna or transmitter, exceptin accordance with FCC multi-transmitter product procedures. Grantee must provideinstallation and operating instructions for complying with FCC multi-transmitter productprocedures. This module is approved in mobile/portable configurations. Only thoseantenna(s) tested with the device or similar antenna(s) with equal or lesser gain may beused with this transmitter. Grantee must coordinate with OEM integrator to determineapplicable host configurations to ensure RF exposure compliance, including simultaneoustransmission SAR requirements according to published KDB 616217 supplementdocumentation. When all conditions of this filing cannot be met installation of this deviceinto specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. Device is aclient only device with enabled for 5GHz band operations and also has 20MHz, 40MHz and80MHz bandwidth modes as described in this filing. This device must utilize the BIOSLocking features as documented in this filing. OEM/Host integrator must be provided withantenna installation instructions and transmitter operating conditions to satisfy RFexposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a hostproduct. The highest reported Body and Simultaneous SAR values are 0.75W/kg and1.44W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application LQ09OXV9Ug2RMvJZpq6fTg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/07/2022

Application Dated: 09/06/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.161  
CC MO 15E 5190.0  -  5230.0 0.153  
CC MO 15E 5210.0  -  5210.0 0.021  
CC MO ND 15E 5260.0  -  5320.0 0.159  
CC MO ND 15E 5270.0  -  5310.0 0.166  
CC MO ND 15E 5290.0  -  5290.0 0.027  
CC MO ND 15E 5500.0  -  5700.0 0.108  
CC MO ND 15E 5510.0  -  5670.0 0.119  
CC MO ND 15E 5710.0  -  5710.0 0.215  
CC MO ND 15E 5720.0  -  5720.0 0.133  
CC MO ND 15E 5530.0  -  5690.0 0.107  
CC MO 15E 5745.0  -  5825.0 0.227  
CC MO 15E 5755.0  -  5795.0 0.227  
CC MO 15E 5775.0  -  5775.0 0.092  

Power Output listed is conducted. Modular Approval. The antenna(s) used for thistransmitter must not transmit simultaneously with any other antenna or transmitter, exceptin accordance with FCC multi-transmitter product procedures. Grantee must provideinstallation and operating instructions for complying with FCC multi-transmitter productprocedures. This module is approved in mobile/portable configurations. Only thoseantenna(s) tested with the device or similar antenna(s) with equal or lesser gain may beused with this transmitter. Grantee must coordinate with OEM integrator to determineapplicable host configurations to ensure RF exposure compliance, including simultaneoustransmission SAR requirements according to published KDB 616217 supplementdocumentation. When all conditions of this filing cannot be met installation of this deviceinto specific final products may require the submission of a permissive change application,containing appropriate data demonstrating compliance, or a new application. Device is aclient only device with enabled for 5GHz band operations and also has 20MHz, 40MHz and80MHz bandwidth modes as described in this filing. This device must utilize the BIOSLocking features as documented in this filing. OEM/Host integrator must be provided withantenna installation instructions and transmitter operating conditions to satisfy RFexposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a hostproduct. The highest reported Body and Simultaneous SAR values are 0.75W/kg and1.44W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application jXObLWx7by+J+1GmMmdinA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/01/2022

Application Dated: 08/30/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless/ Wired X-Ray Flat Panel Dete
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.161  
CC MO 15E 5190.0  -  5230.0 0.153  
CC MO 15E 5210.0  -  5210.0 0.021  
CC MO ND 15E 5260.0  -  5320.0 0.159  
CC MO ND 15E 5270.0  -  5310.0 0.166  
CC MO ND 15E 5290.0  -  5290.0 0.027  
CC MO ND 15E 5500.0  -  5700.0 0.108  
CC MO ND 15E 5510.0  -  5670.0 0.119  
CC MO ND 15E 5710.0  -  5710.0 0.215  
CC MO ND 15E 5720.0  -  5720.0 0.133  
CC MO ND 15E 5530.0  -  5690.0 0.107  
CC MO 15E 5745.0  -  5825.0 0.227  
CC MO 15E 5755.0  -  5795.0 0.227  
CC MO 15E 5775.0  -  5775.0 0.092  

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a client only device enabled for 5GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.75W/kg and 1.44W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application jXObLWx7by+J+1GmMmdinA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/01/2022

Application Dated: 08/30/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless/ Wired X-Ray Flat Panel Dete
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.161  
CC MO 15E 5190.0  -  5230.0 0.153  
CC MO 15E 5210.0  -  5210.0 0.021  
CC MO ND 15E 5260.0  -  5320.0 0.159  
CC MO ND 15E 5270.0  -  5310.0 0.166  
CC MO ND 15E 5290.0  -  5290.0 0.027  
CC MO ND 15E 5500.0  -  5700.0 0.108  
CC MO ND 15E 5510.0  -  5670.0 0.119  
CC MO ND 15E 5710.0  -  5710.0 0.215  
CC MO ND 15E 5720.0  -  5720.0 0.133  
CC MO ND 15E 5530.0  -  5690.0 0.107  
CC MO 15E 5745.0  -  5825.0 0.227  
CC MO 15E 5755.0  -  5795.0 0.227  
CC MO 15E 5775.0  -  5775.0 0.092  

Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a client only device enabled for 5GHz band operations and also has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.75W/kg and 1.44W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application i0OPYLXz8eXNbgOwqwNQDg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/07/2022

Application Dated: 09/06/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.016  

Power Output listed is conducted. Modular Approval filing. The antenna(s) used for thistransmitter must not transmit simultaneously with any other antenna or transmitter, exceptin accordance with FCC multi-transmitter product procedures. Grantee must provideinstallation and operating instructions for complying with FCC multi-transmitter productprocedures. Only those antenna(s) tested with the device or similar antenna(s) with equalor lesser gain may be used with this transmitter. End-users and installers must be providedwith transmitter operating conditions for satisfying RF exposure compliance. The highestreported Body and Simultaneous SAR values are 0.05W/kg and 0.78W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application i0OPYLXz8eXNbgOwqwNQDg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/07/2022

Application Dated: 09/06/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.016  

Power Output listed is conducted. Modular Approval filing. The antenna(s) used for thistransmitter must not transmit simultaneously with any other antenna or transmitter, exceptin accordance with FCC multi-transmitter product procedures. Grantee must provideinstallation and operating instructions for complying with FCC multi-transmitter productprocedures. Only those antenna(s) tested with the device or similar antenna(s) with equalor lesser gain may be used with this transmitter. End-users and installers must be providedwith transmitter operating conditions for satisfying RF exposure compliance. The highestreported Body and Simultaneous SAR values are 0.05W/kg and 0.78W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application AM9OIS6W1DLOLmAfS8zIwg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/07/2022

Application Dated: 09/06/2022
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 


EAS Grant - Application AM9OIS6W1DLOLmAfS8zIwg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/07/2022

Application Dated: 09/06/2022
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600001
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Intel Dual Band Wireless-AC 8265
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 



Mail To: