FCC ID 2A77600002

Wireless/ Wired X-Ray Flat Panel Detectors

by Allengers Medical Systems Limited

Grantee Code: 2A776   Product Code: 00002
Latest application date: 2023-09-22

FCC ID Device Details

FCC ID2A77600002
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A776
Product Code00002
Applicant BusinessAllengers Medical Systems Limited 🇮🇳
Related Domains allengers.net sgs.com
Equipment ClassWireless/ Wired X-Ray Flat Panel Detectors
Test FirmCompliance Certification Services Inc. Wugu Lab.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AS4N000002 Grant Date: 01/19/20232023-09-22
2412-2462 MHzChange in identification of presently authorized equipment. Original FCC ID: 2AS4N000002 Grant Date: 01/19/20232023-09-22

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2023-09-22PDF 1.8 MB
ID Label/Location InfoID Label/Location Info2023-09-22PDF 327.4 KB
Covered_List_AttestationAttestation Statements2023-09-22PDF 443 KB
US AgentAttestation Statements2023-09-22PDF 174.8 KB
FCC Auth Ltr for Change of ID_AllengersCover Letter(s)2023-09-22PDF 337.9 KB
FCC Auth Ltr for Change of ID_INCXCover Letter(s)2023-09-22PDF 160.4 KB
POACover Letter(s)2023-09-22PDF 320.8 KB

Application Information

Application IDWsDU9W5dcnPmVRzg6DtNNg==
Final Action Date2023-09-22
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: 2AS4N000002 Grant Date: 01/19/2023
Applicant FRN0032727349
Model00002
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionWireless/ Wired X-Ray Flat Panel Detectors
Responsible PartySanjeev Kumar Marjara, ra.fdaindia@allengers.net , +919872980168
AgentKevin Kevin Kevin, Compliance Certification Services Inc. Wugu Lab., Kevin.tsai@sgs.com , 886-2-2299-9720
Technical ContactAngel Cheng, Compliance Certification Services Inc. Wugu Lab., Angel.cheng@sgs.com , 886-2-2299-9720
Non-Technical ContactAngel Cheng, Compliance Certification Services Inc. Wugu Lab., Angel.cheng@sgs.com , 886-2-2299-9720
Test FirmHank Lee, Compliance Certification Services Inc. Wugu Lab., hank.lee@sgs.com , 886-2-2299-9720
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is conducted. This is a portable device. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 0.995 W/kg and 1.395 W/kg. This device has 20/40/80 MHz bandwidth modes.

Applications

Application IDDatePurpose
WsDU9W5dcnPmVRzg6DtNNg==2023-09-22Change in identification of presently authorized equipment. Original FCC ID: 2AS4N000002 Grant Date: 01/19/2023
47v6lkDxPEheN3NaxjKVGQ==2023-09-22Change in identification of presently authorized equipment. Original FCC ID: 2AS4N000002 Grant Date: 01/19/2023

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.510000015CCC, MO
5180-5240 MHz0.01115ECC, MO
5745-5825 MHz0.01615ECC, MO

Grants

TCB Grant - Application WsDU9W5dcnPmVRzg6DtNNg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/22/2023

Application Dated: 09/11/2023
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600002
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.011  
CC MO 15E 5745.0  -  5825.0 0.016  

Power Output is conducted. This is a portable device. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 0.995 W/kg and 1.395 W/kg. This device has 20/40/80 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application WsDU9W5dcnPmVRzg6DtNNg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/22/2023

Application Dated: 09/11/2023
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600002
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.011  
CC MO 15E 5745.0  -  5825.0 0.016  

Power Output is conducted. This is a portable device. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 0.995 W/kg and 1.395 W/kg. This device has 20/40/80 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 47v6lkDxPEheN3NaxjKVGQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/22/2023

Application Dated: 09/11/2023
Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road,
Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600002
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.51  

Power Output is conducted. This is a portable device. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 0.622 W/kg and 1.022 W/kg. This device has 20/40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 47v6lkDxPEheN3NaxjKVGQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Allengers Medical Systems Limited
FDA Hall, Unit-2, Bhankarpur, Mubarakpur Road, Derabassi, PunjabP.O. Box 140507,
Mohali, 140507
India
  Date of Grant: 09/22/2023

Application Dated: 09/11/2023
 
Attention: Sanjeev Marjara

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A77600002
Name of Grantee:  Allengers Medical Systems Limited
Equipment Class: Digital Transmission System
Notes: Wireless/ Wired X-Ray Flat Panel Detectors
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.51  

Power Output is conducted. This is a portable device. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 0.622 W/kg and 1.022 W/kg. This device has 20/40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: