FCC ID 2A7JA-SLAM100
Handheld Laser Scanner
by Shenzhen Feima Robotics Technology Co.,Ltd
Grantee Code: 2A7JA Product Code: SLAM100
Latest application date: 2022-07-22
FCC ID Device Details
| FCC ID | 2A7JA-SLAM100 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A7JA |
| Product Code | SLAM100 |
| Applicant Business | Shenzhen Feima Robotics Technology Co.,Ltd 🇨🇳 |
| Related Domains | |
| Equipment Class | Handheld Laser Scanner |
| Test Firm | Shenzhen Anbotek Compliance Laboratory Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2022-07-22 |
| 13.56 MHz | Original Equipment | 2022-07-22 |
| 2412-2462 MHz | Original Equipment | 2022-07-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2023-01-17 | PDF 2.5 MB |
| Int EUT PHOTO | Internal Photos | 2023-01-17 | PDF 4.4 MB |
| Internal photo | Internal Photos | 2023-01-17 | PDF 4.4 MB |
| Ext EUT PHOTO | External Photos | 2023-01-17 | PDF 1.5 MB |
| External photo | External Photos | 2023-01-17 | PDF 1.5 MB |
| Label | ID Label/Location Info | 2022-07-22 | PDF 67.1 KB |
| Label & label location | ID Label/Location Info | 2022-07-22 | PDF 67.1 KB |
| Test Setup photo | Test Setup Photos | 2023-01-17 | PDF 380 KB |
| Test Setup photo | Test Setup Photos | 2023-01-17 | PDF 804.3 KB |
| Test Report | Test Report | 2022-07-22 | PDF 4 MB |
| Test Report | Test Report | 2022-07-22 | PDF 1.3 MB |
| Test Report | Test Report | 2022-07-22 | PDF 5.2 MB |
| Test ReportSAR | RF Exposure Info | 2022-07-22 | PDF 4.8 MB |
| Agent Authorization Rev 1.0 | Cover Letter(s) | 2022-07-22 | PDF 62.2 KB |
| Declaration Letter of Model Difference | Cover Letter(s) | 2022-07-22 | PDF 88.5 KB |
| FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 2022-07-22 | PDF 90.4 KB |
| FCC Software Configuration Control Declaration Rev1.1 | Cover Letter(s) | 2022-07-22 | PDF 93.4 KB |
| Block Diagram Metadata only | Block Diagram | PDF 178.2 KB | |
| SCH Metadata only | Schematics | PDF 1.3 MB | |
| OP Metadata only | Operational Description | PDF 63.1 KB | |
| SOFTWARE SECURITY DESCRIPTION Metadata only | SDR Software/Security Inf | PDF 143.5 KB |
Application Information
| Application ID | qgEPnaSPMhgWfc53+wk7wg== |
|---|---|
| Final Action Date | 2022-07-22 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0032566242 |
| Model | SLAM100 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Handheld Laser Scanner |
| Responsible Party | Michael Ni, test supervisor, nixy@feimarobotics.com |
| Technical Contact | Shenzhen Feima Robotics Technology Co.,Ltd, nixy@feimarobotics.com |
| Test Firm | Jeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/17/2023 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.48W/kg and 1.05W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| qgEPnaSPMhgWfc53+wk7wg== | 2022-07-22 | Original Equipment |
| hvOamFDjq50aBvgHD+dDyg== | 2022-07-22 | Original Equipment |
| BAPTMsmNvveU0/+6YSkYtA== | 2022-07-22 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application qgEPnaSPMhgWfc53+wk7wg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 07/22/2022 Application Dated: 07/22/2022 |
| Shenzhen Feima Robotics Technology Co.,Ltd |
| 1/f,16, Zhiheng Industrial Park, Nantou Second |
| Road,Nantou Street, Nanshan District |
| Shenzhen, 518000 China |
| Attention: Michael Ni , test supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A7JA-SLAM100 |
| Name of Grantee: | Shenzhen Feima Robotics Technology Co.,Ltd |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Handheld Laser Scanner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.0695 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.0461 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.0794 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.48W/kg and 1.05W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application qgEPnaSPMhgWfc53+wk7wg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Feima Robotics Technology Co.,Ltd 1/f,16, Zhiheng Industrial Park, Nantou Second Road,Nantou Street, Nanshan District Shenzhen, 518000 China |
Date of Grant: 07/22/2022 Application Dated: 07/22/2022 |
| Attention: Michael Ni , test supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A7JA-SLAM100 |
| Name of Grantee: | Shenzhen Feima Robotics Technology Co.,Ltd |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Handheld Laser Scanner |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.0695 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.0461 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.0794 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.48W/kg and 1.05W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 07/22/2022 Application Dated: 07/22/2022 |
| Shenzhen Feima Robotics Technology Co.,Ltd |
| 1/f,16, Zhiheng Industrial Park, Nantou Second |
| Road,Nantou Street, Nanshan District |
| Shenzhen, 518000 China |
| Attention: Michael Ni , test supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A7JA-SLAM100 |
| Name of Grantee: | Shenzhen Feima Robotics Technology Co.,Ltd |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Handheld Laser Scanner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application hvOamFDjq50aBvgHD+dDyg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Feima Robotics Technology Co.,Ltd 1/f,16, Zhiheng Industrial Park, Nantou Second Road,Nantou Street, Nanshan District Shenzhen, 518000 China |
Date of Grant: 07/22/2022 Application Dated: 07/22/2022 |
| Attention: Michael Ni , test supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A7JA-SLAM100 |
| Name of Grantee: | Shenzhen Feima Robotics Technology Co.,Ltd |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Handheld Laser Scanner |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 07/22/2022 Application Dated: 07/22/2022 |
| Shenzhen Feima Robotics Technology Co.,Ltd |
| 1/f,16, Zhiheng Industrial Park, Nantou Second |
| Road,Nantou Street, Nanshan District |
| Shenzhen, 518000 China |
| Attention: Michael Ni , test supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A7JA-SLAM100 |
| Name of Grantee: | Shenzhen Feima Robotics Technology Co.,Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Handheld Laser Scanner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.1352 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.60W/kg and 1.05W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application BAPTMsmNvveU0/+6YSkYtA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Feima Robotics Technology Co.,Ltd 1/f,16, Zhiheng Industrial Park, Nantou Second Road,Nantou Street, Nanshan District Shenzhen, 518000 China |
Date of Grant: 07/22/2022 Application Dated: 07/22/2022 |
| Attention: Michael Ni , test supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A7JA-SLAM100 |
| Name of Grantee: | Shenzhen Feima Robotics Technology Co.,Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Handheld Laser Scanner |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.1352 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.60W/kg and 1.05W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |