FCC ID 2A7JA-SLAM100

Handheld Laser Scanner

by Shenzhen Feima Robotics Technology Co.,Ltd

Grantee Code: 2A7JA   Product Code: SLAM100
Latest application date: 2022-07-22

FCC ID Device Details

FCC ID2A7JA-SLAM100
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A7JA
Product CodeSLAM100
Applicant BusinessShenzhen Feima Robotics Technology Co.,Ltd 🇨🇳
Related Domains feimarobotics.com
Equipment ClassHandheld Laser Scanner
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2022-07-22
13.56 MHzOriginal Equipment2022-07-22
2412-2462 MHzOriginal Equipment2022-07-22

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-01-17PDF 2.5 MB
Int EUT PHOTOInternal Photos2023-01-17PDF 4.4 MB
Internal photoInternal Photos2023-01-17PDF 4.4 MB
Ext EUT PHOTOExternal Photos2023-01-17PDF 1.5 MB
External photoExternal Photos2023-01-17PDF 1.5 MB
LabelID Label/Location Info2022-07-22PDF 67.1 KB
Label & label locationID Label/Location Info2022-07-22PDF 67.1 KB
Test Setup photoTest Setup Photos2023-01-17PDF 380 KB
Test Setup photoTest Setup Photos2023-01-17PDF 804.3 KB
Test ReportTest Report2022-07-22PDF 4 MB
Test ReportTest Report2022-07-22PDF 1.3 MB
Test ReportTest Report2022-07-22PDF 5.2 MB
Test ReportSARRF Exposure Info2022-07-22PDF 4.8 MB
Agent Authorization Rev 1.0Cover Letter(s)2022-07-22PDF 62.2 KB
Declaration Letter of Model DifferenceCover Letter(s)2022-07-22PDF 88.5 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2022-07-22PDF 90.4 KB
FCC Software Configuration Control Declaration Rev1.1Cover Letter(s)2022-07-22PDF 93.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 178.2 KB
SCH Metadata onlySchematicsPDF 1.3 MB
OP Metadata onlyOperational DescriptionPDF 63.1 KB
SOFTWARE SECURITY DESCRIPTION Metadata onlySDR Software/Security InfPDF 143.5 KB

Application Information

Application IDqgEPnaSPMhgWfc53+wk7wg==
Final Action Date2022-07-22
Application PurposeOriginal Equipment
Applicant FRN0032566242
ModelSLAM100
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionHandheld Laser Scanner
Responsible PartyMichael Ni, test supervisor, nixy@feimarobotics.com , 0755-83709933
Technical ContactShenzhen Feima Robotics Technology Co.,Ltd, nixy@feimarobotics.com
Test FirmJeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com , 86-755-26064492
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/17/2023
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.48W/kg and 1.05W/kg.

Applications

Application IDDatePurpose
qgEPnaSPMhgWfc53+wk7wg==2022-07-22Original Equipment
hvOamFDjq50aBvgHD+dDyg==2022-07-22Original Equipment
BAPTMsmNvveU0/+6YSkYtA==2022-07-22Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
13.56 MHz15CCC
2412-2462 MHz0.135200015CCC, MO
5180-5240 MHz0.069515ECC, MO
5500-5700 MHz0.046115ECC, MO, ND
5745-5825 MHz0.079415ECC, MO

Grants

TCB Grant - Application qgEPnaSPMhgWfc53+wk7wg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/22/2022

Application Dated: 07/22/2022
Shenzhen Feima Robotics Technology Co.,Ltd
1/f,16, Zhiheng Industrial Park, Nantou Second
Road,Nantou Street, Nanshan District
Shenzhen, 518000
China
 
Attention: Michael Ni , test supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A7JA-SLAM100
Name of Grantee:  Shenzhen Feima Robotics Technology Co.,Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Handheld Laser Scanner
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0695  
CC MO ND 15E 5500.0  -  5700.0 0.0461  
CC MO 15E 5745.0  -  5825.0 0.0794  

Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.48W/kg and 1.05W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application qgEPnaSPMhgWfc53+wk7wg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Feima Robotics Technology Co.,Ltd
1/f,16, Zhiheng Industrial Park, Nantou Second Road,Nantou Street, Nanshan District
Shenzhen, 518000
China
  Date of Grant: 07/22/2022

Application Dated: 07/22/2022
 
Attention: Michael Ni , test supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A7JA-SLAM100
Name of Grantee:  Shenzhen Feima Robotics Technology Co.,Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Handheld Laser Scanner
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0695  
CC MO ND 15E 5500.0  -  5700.0 0.0461  
CC MO 15E 5745.0  -  5825.0 0.0794  

Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.48W/kg and 1.05W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application hvOamFDjq50aBvgHD+dDyg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/22/2022

Application Dated: 07/22/2022
Shenzhen Feima Robotics Technology Co.,Ltd
1/f,16, Zhiheng Industrial Park, Nantou Second
Road,Nantou Street, Nanshan District
Shenzhen, 518000
China
 
Attention: Michael Ni , test supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A7JA-SLAM100
Name of Grantee:  Shenzhen Feima Robotics Technology Co.,Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Handheld Laser Scanner
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application hvOamFDjq50aBvgHD+dDyg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Feima Robotics Technology Co.,Ltd
1/f,16, Zhiheng Industrial Park, Nantou Second Road,Nantou Street, Nanshan District
Shenzhen, 518000
China
  Date of Grant: 07/22/2022

Application Dated: 07/22/2022
 
Attention: Michael Ni , test supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A7JA-SLAM100
Name of Grantee:  Shenzhen Feima Robotics Technology Co.,Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Handheld Laser Scanner
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application BAPTMsmNvveU0/+6YSkYtA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/22/2022

Application Dated: 07/22/2022
Shenzhen Feima Robotics Technology Co.,Ltd
1/f,16, Zhiheng Industrial Park, Nantou Second
Road,Nantou Street, Nanshan District
Shenzhen, 518000
China
 
Attention: Michael Ni , test supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A7JA-SLAM100
Name of Grantee:  Shenzhen Feima Robotics Technology Co.,Ltd
Equipment Class: Digital Transmission System
Notes: Handheld Laser Scanner
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.1352  

Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.60W/kg and 1.05W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application BAPTMsmNvveU0/+6YSkYtA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Feima Robotics Technology Co.,Ltd
1/f,16, Zhiheng Industrial Park, Nantou Second Road,Nantou Street, Nanshan District
Shenzhen, 518000
China
  Date of Grant: 07/22/2022

Application Dated: 07/22/2022
 
Attention: Michael Ni , test supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A7JA-SLAM100
Name of Grantee:  Shenzhen Feima Robotics Technology Co.,Ltd
Equipment Class: Digital Transmission System
Notes: Handheld Laser Scanner
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.1352  

Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory simultaneous transmission use conditions is 0.60W/kg and 1.05W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: