FCC ID 2A7WU-GA3001
Thermo Hygrometer
by SHENZHEN DAYBETTER OPTO-ELECTRONICS CO.,LTD
Grantee Code: 2A7WU Product Code: GA3001
Latest application date: 2025-06-23
FCC ID Device Details
| FCC ID | 2A7WU-GA3001 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A7WU |
| Product Code | GA3001 |
| Applicant Business | SHENZHEN DAYBETTER OPTO-ELECTRONICS CO.,LTD 🇨🇳 |
| Equipment Class | Thermo Hygrometer |
| Test Firm | Shenzhen LCS Compliance Testing Laboratory Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2025-06-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2025-06-23 | PDF 3.1 MB |
| Internal photos | Internal Photos | 2025-06-23 | PDF 4.6 MB |
| External photos | External Photos | 2025-06-23 | PDF 1 MB |
| Label and label location | ID Label/Location Info | 2025-06-23 | PDF 413.5 KB |
| Test setup photos | Test Setup Photos | 2025-06-23 | PDF 2 MB |
| Antenna information | Test Report | 2025-06-23 | PDF 537.3 KB |
| Appendix A test data BT LE | Test Report | 2025-06-23 | PDF 2.5 MB |
| Appendix B test data 2G4WLAN | Test Report | 2025-06-23 | PDF 3.9 MB |
| Test Report 2G4WLAN | Test Report | 2025-06-23 | PDF 1.2 MB |
| Test Report BT LE | Test Report | 2025-06-23 | PDF 1 MB |
| Agent attestation letter | Attestation Statements | 2025-06-23 | PDF 366.9 KB |
| Covered equipment letter | Attestation Statements | 2025-06-23 | PDF 180.5 KB |
| Due digilence letter | Attestation Statements | 2025-06-23 | PDF 181.4 KB |
| Confidentiality request letter | Cover Letter(s) | 2025-06-23 | PDF 186.9 KB |
| Letter of declaration disable channel 12 and 13 by software | Cover Letter(s) | 2025-06-23 | PDF 164.8 KB |
| Letter of declaration model difference | Cover Letter(s) | 2025-06-23 | PDF 107.2 KB |
| RF exposure evaluation | RF Exposure Info | 2025-06-23 | PDF 471.6 KB |
| Block diagram Metadata only | Block Diagram | PDF 379.8 KB | |
| Schematic Metadata only | Schematics | PDF 115.2 KB | |
| Operation description Metadata only | Operational Description | PDF 112.3 KB |
Application Information
| Application ID | GlmJu2y0YyGd8xMYjbkajA== |
|---|---|
| Final Action Date | 2025-06-23 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0032642480 |
| Model | GA3001 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Thermo Hygrometer |
| Responsible Party | WANG NING, 2355840691@qq.com |
| Test Firm | Gavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com |
| TCB Email | o.kneip@kl-certification.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is maximum peak conducted output power. The device supports 20 MHz bandwidth modes as described in this filing. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device contains 2.4GHz WLAN and BLE transmitters. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| GlmJu2y0YyGd8xMYjbkajA== | 2025-06-23 | Original Equipment |
Equipment Authorization
| Frequency | Output |
|---|---|
| 2402-2480 MHz | 0.0017 |
| 2412-2462 MHz | 0.0798 |
Grants
TCB Grant - Application GlmJu2y0YyGd8xMYjbkajA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
KL-Certification GmbH Heinrich-Hertz-Allee 7 St. Ingbert, 66386 Germany |
Date of Grant: 06/23/2025 Application Dated: 06/23/2025 |
| SHENZHEN DAYBETTER OPTO-ELECTRONICS CO.,LTD |
| 4F,BUILDING 2, ANTUOSHAN HI-TECH PARK |
| BAOAN DISTRICT |
| SHENZHEN, 518000 China |
| Attention: WANG NING , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A7WU-GA3001 |
| Name of Grantee: | SHENZHEN DAYBETTER OPTO-ELECTRONICS CO.,LTD |
| Equipment Class: | Digital Transmission System |
| Notes: | Thermo Hygrometer |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0017 | |||
| 15C | 2412.0 - 2462.0 | 0.0798 |
| Power listed is maximum peak conducted output power. The device supports 20 MHz bandwidth modes as described in this filing. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device contains 2.4GHz WLAN and BLE transmitters. |