FCC ID 2A8N5S1PLUS

MOBILE PHONE

by RUA Trading LLC

Grantee Code: 2A8N5   Product Code: S1PLUS
Latest application date: 2023-01-08

FCC ID Device Details

FCC ID2A8N5S1PLUS
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A8N5
Product CodeS1PLUS
Applicant BusinessRUA Trading LLC 🇺🇸
Related Domains ruatrading.com
Equipment ClassMOBILE PHONE
Test FirmSHENZHEN TONGCE TESTING LAB

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2023-01-08
1852.4-1907.6 MHzOriginal Equipment2023-01-08

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2023-01-08PDF 1.2 MB
Internal photosInternal Photos2023-01-08PDF 2.4 MB
External PhotosExternal Photos2023-01-08PDF 562.3 KB
LabelID Label/Location Info2023-01-08PDF 1.5 MB
Test Setup PhotosTest Setup Photos2023-01-08PDF 163.1 KB
Test Setup PhotosTest Setup Photos2023-01-08PDF 121 KB
ANT REPORTTest Report2023-01-08PDF 399.5 KB
Antenna SpecificationTest Report2023-01-08PDF 399.5 KB
Test ReportTest Report2023-01-08PDF 4.4 MB
Test ReportTest Report2023-01-08PDF 163.1 KB
Test Report SARRF Exposure Info2023-01-08PDF 3.7 MB
Test Report SAR Metadata onlyTest Report2023-01-08PDF 3.7 MB
Agent Authorization Rev 1.0Cover Letter(s)2023-01-08PDF 140.4 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2023-01-08PDF 118.1 KB
RF ExposureRF Exposure Info2023-01-08PDF 405.4 KB
Block Metadata onlyBlock DiagramPDF 233.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 233.9 KB
SCH Metadata onlySchematicsPDF 504.3 KB
OP Metadata onlyOperational DescriptionPDF 139.2 KB
Tune up Metadata onlySDR Software/Security InfPDF 58.6 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 36.3 KB

Application Information

Application IDaj8Usgc97nAPalMBGRPk0A==
Final Action Date2023-01-08
Application PurposeOriginal Equipment
Applicant FRN0032877219
ModelS1PLUS
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionMOBILE PHONE
Responsible PartyMurtaza Panjwani, purchasing@ruatrading.com , 1-305-372-9590
Technical ContactRUA Trading LLC, purchasing@ruatrading.com
Test FirmBeryl Zhao, SHENZHEN TONGCE TESTING LAB, berylzhao@tct-lab.com , +8675527208735
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power.

Applications

Application IDDatePurpose
aj8Usgc97nAPalMBGRPk0A==2023-01-08Original Equipment
0Lf24QFvFfDoBHI4IfYrCQ==2023-01-08Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz1.050.018ppm248KGXW22H
826.4-846.6 MHz0.120.02ppm4M11F9W22H
1850.2-1909.8 MHz0.630.022ppm247KGXW24E
1852.4-1907.6 MHz0.140.019ppm4M10F9W24E
2402-2480 MHz0.000700015C

Grants

TCB Grant - Application aj8Usgc97nAPalMBGRPk0A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/08/2023

Application Dated: 01/06/2023
RUA Trading LLC
8212 NW 30th Terr
Doral, FL 33122
 
Attention: Murtaza Panjwani

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A8N5S1PLUS
Name of Grantee:  RUA Trading LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: MOBILE PHONE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0007  

Output power listed is conducted power.

EAS Grant - Application aj8Usgc97nAPalMBGRPk0A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

RUA Trading LLC
8212 NW 30th Terr
Doral, FL 33122
United States
  Date of Grant: 01/08/2023

Application Dated: 01/06/2023
 
Attention: Murtaza Panjwani

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A8N5S1PLUS
Name of Grantee:  RUA Trading LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: MOBILE PHONE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0007  

Output power listed is conducted power.



TCB Grant - Application 0Lf24QFvFfDoBHI4IfYrCQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/08/2023

Application Dated: 01/08/2023
RUA Trading LLC
8212 NW 30th Terr
Doral, FL 33122
 
Attention: Murtaza Panjwani

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A8N5S1PLUS
Name of Grantee:  RUA Trading LLC
Equipment Class: PCS Licensed Transmitter held to ear
Notes: MOBILE PHONE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.05 0.018  PM 248KGXW
24E 1850.2  -  1909.8 0.63 0.022  PM 247KGXW
22H 826.4  -  846.6 0.12 0.02  PM 4M11F9W
24E 1852.4  -  1907.6 0.14 0.019  PM 4M10F9W

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.68W/kg, 0.72W/kg and 0.77W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

EAS Grant - Application 0Lf24QFvFfDoBHI4IfYrCQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

RUA Trading LLC
8212 NW 30th Terr
Doral, FL 33122
United States
  Date of Grant: 01/08/2023

Application Dated: 01/08/2023
 
Attention: Murtaza Panjwani

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A8N5S1PLUS
Name of Grantee:  RUA Trading LLC
Equipment Class: PCS Licensed Transmitter held to ear
Notes: MOBILE PHONE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.05 0.018  PM 248KGXW
24E 1850.2  -  1909.8 0.63 0.022  PM 247KGXW
22H 826.4  -  846.6 0.12 0.02  PM 4M11F9W
24E 1852.4  -  1907.6 0.14 0.019  PM 4M10F9W

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.68W/kg, 0.72W/kg and 0.77W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.



Mail To: