FCC ID 2A8YS-T150

3D Laser Scanner

by EPiC LiDAR Tech Co., Ltd.

Grantee Code: 2A8YS   Product Code: T150
Latest application date: 2026-07-24

FCC ID Device Details

FCC ID2A8YS-T150
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A8YS
Product CodeT150
Applicant BusinessEPiC LiDAR Tech Co., Ltd. 🇨🇳
Related Domains epiclidar.cn rockrobotic.com
Equipment Class3D Laser Scanner
Test FirmShenzhen LGT Test Service Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2026-07-24

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2026-07-24PDF 5.7 MB
Internal PhotosInternal Photos2026-07-24PDF 5 MB
External PhotosExternal Photos2026-07-24PDF 1.5 MB
Label InformationID Label/Location Info2026-07-24PDF 122.1 KB
Test Setup PhotosTest Setup Photos2026-07-24PDF 218.9 KB
Antenna ReportTest Report2026-07-24PDF 1.5 MB
Test ReportTest Report2026-07-24PDF 4.6 MB
Attestation Statements of US Agent for Service of Process, 2.911(d)(7)Attestation Statements2026-07-24PDF 60.3 KB
Attestation of Covered Equipment, 2.911(d)(5)(i)(ii)Attestation Statements2026-07-24PDF 107.1 KB
Agent Authorization Letter TemplateCover Letter(s)2026-07-24PDF 189 KB
Short & Long Term Confidentiality RequestCover Letter(s)2026-07-24PDF 86.7 KB
Software Configuration Control DeclarationCover Letter(s)2026-07-24PDF 91.8 KB
RF Exposure ReportRF Exposure Info2026-07-24PDF 283.4 KB
BLOCK Metadata onlyBlock DiagramPDF 196.3 KB
SCH Metadata onlySchematicsPDF 283.4 KB
Operational Description Metadata onlyOperational DescriptionPDF 63.3 KB
SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Metadata onlySDR Software/Security Info.PDF 137.7 KB

Application Information

Application IDwaAc85IpAYeornNGizhICg==
Final Action Date2026-07-24
Application PurposeOriginal Equipment
Applicant FRN0032984148
ModelT150
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device Description3D Laser Scanner
Responsible PartyYuan dewen, yuandewen@epiclidar.cn , 027-8795 9978
Technical ContactEPiC LiDAR Tech Co., Ltd., yuandewen@epiclidar.cn
Non-Technical ContactAlex Knoll, ROCK Robotic Inc., Alex@ROCKRobotic.com
Test FirmWen Wen, Shenzhen LGT Test Service Co., Ltd., qa@lgt-cert.com , 0755-89668180
TCB Emailanezam@qai.org
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
waAc85IpAYeornNGizhICg==2026-07-24Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5180-5240 MHz0.050515EMO
5745-5825 MHz0.056515EMO

Grants

TCB Grant - Application waAc85IpAYeornNGizhICg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 07/24/2026

Application Dated: 07/24/2026
EPiC LiDAR Tech Co., Ltd.
Room 302, Area B, Building 21, West Zone,
Wuhan CEC Information Harbour, Jiangxia District,
Wuhan,
China
 
Attention: Yuan dewen ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A8YS-T150
Name of Grantee:  EPiC LiDAR Tech Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 3D Laser Scanner
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5180.0  -  5240.0 0.0505  
MO 15E 5745.0  -  5825.0 0.0565  

Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.