FCC ID 2A95S-S001
Smart watch
by MELTEC COMUNICACIONES SA
Grantee Code: 2A95S Product Code: S001
Latest application date: 2023-02-12
FCC ID Device Details
| FCC ID | 2A95S-S001 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A95S |
| Product Code | S001 |
| Applicant Business | MELTEC COMUNICACIONES SA 🇨🇴 |
| Related Domains | |
| Equipment Class | Smart watch |
| Test Firm | Shenzhen Anbotek Compliance Laboratory Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2545-2645 MHz | Original Equipment | 2023-02-12 |
| 2412-2462 MHz | Original Equipment | 2023-02-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2023-02-12 | PDF 1.3 MB |
| User manual | Users Manual | 2023-02-12 | PDF 1.3 MB |
| Internal Photos | Internal Photos | 2023-02-12 | PDF 2.2 MB |
| Internal photo | Internal Photos | 2023-02-12 | PDF 2.2 MB |
| External Photo | External Photos | 2023-02-12 | PDF 5.4 MB |
| External photo | External Photos | 2023-02-12 | PDF 5.4 MB |
| Label and Label location | ID Label/Location Info | 2023-02-12 | PDF 83.9 KB |
| LabelandLocation | ID Label/Location Info | 2023-02-12 | PDF 83.9 KB |
| Test Setup Photos | Test Setup Photos | 2023-02-12 | PDF 1.9 MB |
| Test photos | Test Setup Photos | 2023-02-12 | PDF 2.3 MB |
| Test Report | Test Report | 2023-02-12 | PDF 4.1 MB |
| Test Report | Test Report | 2023-02-12 | PDF 4.7 MB |
| Test Report SAR | RF Exposure Info | 2023-02-12 | PDF 4.6 MB |
| antenna report | Test Report | 2023-02-12 | PDF 736.8 KB |
| 2.911_(d)(7) US Agent for Service of Process | Attestation Statements | 2023-02-12 | PDF 61 KB |
| 2.911_(d)(7) US Agent for Service of Process v1.2 | Attestation Statements | 2023-02-12 | PDF 59.8 KB |
| 2911_(d)(5)(i) Certification Equipment Type v12 | Attestation Statements | 2023-02-12 | PDF 208.9 KB |
| 2911_(d)(5)(ii) Certificiation Applicant v12 | Attestation Statements | 2023-02-12 | PDF 209.8 KB |
| FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 2023-02-12 | PDF 52 KB |
| Letter of Authorization Rev 1.0 | Cover Letter(s) | 2023-02-12 | PDF 55.1 KB |
| LetterofAuthorizationRev1.0 | Cover Letter(s) | 2023-02-12 | PDF 55.1 KB |
| Long_Term_Confidentiality | Cover Letter(s) | 2023-02-12 | PDF 52 KB |
| Block Diagram Metadata only | Block Diagram | PDF 96.8 KB | |
| SCH Metadata only | Schematics | PDF 693.9 KB | |
| OP Metadata only | Operational Description | PDF 97.6 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 248.7 KB | |
| Tune-up Metadata only | Parts List/Tune Up Info | PDF 59.8 KB |
Application Information
| Application ID | t2D1KnR+tU9iolgVxx4Pfg== |
|---|---|
| Final Action Date | 2023-02-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0033356957 |
| Model | S001 |
| Frequency Range | 2545-2645 MHz |
| Equipment Class | PCT - PCS Licensed Transmitter worn on body |
| Device Description | Smart watch |
| Responsible Party | Juan Pablo Ruiz, CTO, jruiz@meltec.com.co |
| Technical Contact | MELTEC COMUNICACIONES SA, jruiz@meltec.com.co |
| Test Firm | Jeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for face Limit is 1.6 W/kg and Wristbands is 4.0W/kg. The evaluation distance for product specific (next-to-mouth) and extremity (wrist) is 10 mm and 0 mm respectively. The highest reported SAR for product specific (next-to-mouth), simultaneous transmission, and extremity (wrist) use conditions is 1.01 W/kg, 0.78 W/kg, and 1.11 W/kg, respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| t2D1KnR+tU9iolgVxx4Pfg== | 2023-02-12 | Original Equipment |
| OfeRz2roY8mxQI+YurrQMw== | 2023-02-12 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 824.2-848.8 MHz | 0.6109 | 2.5ppm | 251KG7W | 22H |
| 826.4-846.6 MHz | 0.1191 | 2.5ppm | 4M16F9W | 22H |
| 829-844 MHz | 0.1337 | 2.5ppm | 8M97W7D | 22H |
| 829-844 MHz | 0.1803 | 2.5ppm | 8M97G7D | 22H |
| 1850.2 MHz | 0.5929 | 2.5ppm | 246KGXW | 24E |
| 1850.2-1909.8 MHz | 0.5483 | 2.5ppm | 245KG7W | 24E |
| 1852.4-1907.6 MHz | 0.2443 | 2.5ppm | 4M15F9W | 24E |
| 1860-1900 MHz | 0.1194 | 2.5ppm | 17M9G7D | 24E |
| 1860-1900 MHz | 0.1132 | 2.5ppm | 17M9W7D | 24E |
| 2402-2480 MHz | 0.0014 | 15C | ||
| 2412-2462 MHz | 0.0336 | 15C | ||
| 2545-2645 MHz | 0.1854 | 2.5ppm | 17M9G7D | 27 |
| 2545-2645 MHz | 0.1064 | 2.5ppm | 17M9W7D | 27 |
Grants
TCB Grant - Application t2D1KnR+tU9iolgVxx4Pfg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 02/12/2023 Application Dated: 02/10/2023 |
| MELTEC COMUNICACIONES SA |
| Calle 130A # 58A-29 |
| Bogota DC, 111111 Colombia |
| Attention: Juan Pablo Ruiz , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A95S-S001 |
| Name of Grantee: | MELTEC COMUNICACIONES SA |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Smart watch |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.5066 | 2.5 PM | 247KGXW | |
| 22H | 824.2 - 848.8 | 0.6109 | 2.5 PM | 251KG7W | |
| 24E | 1850.2 - 1850.2 | 0.5929 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.5483 | 2.5 PM | 245KG7W | |
| 24E | 1852.4 - 1907.6 | 0.2443 | 2.5 PM | 4M15F9W | |
| 22H | 826.4 - 846.6 | 0.1191 | 2.5 PM | 4M16F9W | |
| 24E | 1860.0 - 1900.0 | 0.1194 | 2.5 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.1132 | 2.5 PM | 17M9W7D | |
| 22H | 829.0 - 844.0 | 0.1803 | 2.5 PM | 8M97G7D | |
| 22H | 829.0 - 844.0 | 0.1337 | 2.5 PM | 8M97W7D | |
| 27 | 2545.0 - 2645.0 | 0.1854 | 2.5 PM | 17M9G7D | |
| 27 | 2545.0 - 2645.0 | 0.1064 | 2.5 PM | 17M9W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for face Limit is 1.6 W/kg and Wristbands is 4.0W/kg. The evaluation distance for product specific (next-to-mouth) and extremity (wrist) is 10 mm and 0 mm respectively. The highest reported SAR for product specific (next-to-mouth), simultaneous transmission, and extremity (wrist) use conditions is 1.01 W/kg, 0.78 W/kg, and 1.11 W/kg, respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
EAS Grant - Application t2D1KnR+tU9iolgVxx4Pfg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
MELTEC COMUNICACIONES SA Calle 130A # 58A-29 Bogota DC, 111111 Colombia |
Date of Grant: 02/12/2023 Application Dated: 02/10/2023 |
| Attention: Juan Pablo Ruiz , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A95S-S001 |
| Name of Grantee: | MELTEC COMUNICACIONES SA |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Smart watch |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.5066 | 2.5 PM | 247KGXW | |
| 22H | 824.2 - 848.8 | 0.6109 | 2.5 PM | 251KG7W | |
| 24E | 1850.2 - 1850.2 | 0.5929 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.5483 | 2.5 PM | 245KG7W | |
| 24E | 1852.4 - 1907.6 | 0.2443 | 2.5 PM | 4M15F9W | |
| 22H | 826.4 - 846.6 | 0.1191 | 2.5 PM | 4M16F9W | |
| 24E | 1860.0 - 1900.0 | 0.1194 | 2.5 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.1132 | 2.5 PM | 17M9W7D | |
| 22H | 829.0 - 844.0 | 0.1803 | 2.5 PM | 8M97G7D | |
| 22H | 829.0 - 844.0 | 0.1337 | 2.5 PM | 8M97W7D | |
| 27 | 2545.0 - 2645.0 | 0.1854 | 2.5 PM | 17M9G7D | |
| 27 | 2545.0 - 2645.0 | 0.1064 | 2.5 PM | 17M9W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for face Limit is 1.6 W/kg and Wristbands is 4.0W/kg. The evaluation distance for product specific (next-to-mouth) and extremity (wrist) is 10 mm and 0 mm respectively. The highest reported SAR for product specific (next-to-mouth), simultaneous transmission, and extremity (wrist) use conditions is 1.01 W/kg, 0.78 W/kg, and 1.11 W/kg, respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 02/12/2023 Application Dated: 02/10/2023 |
| MELTEC COMUNICACIONES SA |
| Calle 130A # 58A-29 |
| Bogota DC, 111111 Colombia |
| Attention: Juan Pablo Ruiz , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A95S-S001 |
| Name of Grantee: | MELTEC COMUNICACIONES SA |
| Equipment Class: | Digital Transmission System |
| Notes: | Smart watch |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0014 | |||
| 15C | 2412.0 - 2462.0 | 0.0336 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for face Limit is 1.6 W/kg and Wristbands is 4.0W/kg. Device types have also been tested against this SAR limit. The evaluation distance for product specific (next-to-mouth) and extremity (wrist) is 10 mm and 0 mm separately. The highest reported SAR for product specific (next-to-mouth), simultaneous transmission, and extremity (wrist) use conditions is 0.33 W/kg, 0.33 W/kg, and 1.11 W/kg, respectively. |
EAS Grant - Application OfeRz2roY8mxQI+YurrQMw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
MELTEC COMUNICACIONES SA Calle 130A # 58A-29 Bogota DC, 111111 Colombia |
Date of Grant: 02/12/2023 Application Dated: 02/10/2023 |
| Attention: Juan Pablo Ruiz , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A95S-S001 |
| Name of Grantee: | MELTEC COMUNICACIONES SA |
| Equipment Class: | Digital Transmission System |
| Notes: | Smart watch |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0014 | |||
| 15C | 2412.0 - 2462.0 | 0.0336 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for face Limit is 1.6 W/kg and Wristbands is 4.0W/kg. Device types have also been tested against this SAR limit. The evaluation distance for product specific (next-to-mouth) and extremity (wrist) is 10 mm and 0 mm separately. The highest reported SAR for product specific (next-to-mouth), simultaneous transmission, and extremity (wrist) use conditions is 0.33 W/kg, 0.33 W/kg, and 1.11 W/kg, respectively. |
| Mail To: |