FCC ID 2A98M-POWERMAX1800
Portable Power Station
by Shenzhen Doke Communication Co.,Ltd
Grantee Code: 2A98M Product Code: POWERMAX1800
Latest application date: 2025-07-27
FCC ID Device Details
| FCC ID | 2A98M-POWERMAX1800 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2A98M |
| Product Code | POWERMAX1800 |
| Applicant Business | Shenzhen Doke Communication Co.,Ltd 🇨🇳 |
| Equipment Class | Portable Power Station |
| Test Firm | KSIGN (Guangdong) Testing Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2025-07-27 |
| 0.115-0.205 MHz | Original Equipment | 2025-07-27 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2025-07-27 | PDF 5.6 MB |
| Internal Photos | Internal Photos | 2025-07-27 | PDF 2.2 MB |
| Internal photos | Internal Photos | 2025-07-27 | PDF 2.2 MB |
| External Photos | External Photos | 2025-07-27 | PDF 670.1 KB |
| External photos | External Photos | 2025-07-27 | PDF 670.1 KB |
| Label | ID Label/Location Info | 2025-07-27 | PDF 1.3 MB |
| Test Setup photo | Test Setup Photos | 2025-07-27 | PDF 767.1 KB |
| Test photos | Test Setup Photos | 2025-07-27 | PDF 767.1 KB |
| 47 CFR Part 15.247_BLE | Test Report | 2025-07-27 | PDF 4.6 MB |
| 47CFRPart15.209 WPT | Test Report | 2025-07-27 | PDF 2.1 MB |
| 47CFRPart15.247 WIFI | Test Report | 2025-07-27 | PDF 3.8 MB |
| ANT | Test Report | 2025-07-27 | PDF 374.9 KB |
| ANT | Test Report | 2025-07-27 | PDF 332.5 KB |
| 2.911 (d)(5)(i)CertificationEquipmentTypev1.2 | Attestation Statements | 2025-07-27 | PDF 198.4 KB |
| 2.911 (d)(5)(ii)CertificationApplicantv1.3 | Attestation Statements | 2025-07-27 | PDF 189.6 KB |
| 2.911 (d)(5)(ii)CertificiationApplicantv1.2 | Attestation Statements | 2025-07-27 | PDF 189.6 KB |
| 2.911 (d)(7)USAgentforServiceofProcessv1.3 | Attestation Statements | 2025-07-27 | PDF 350.6 KB |
| 2.911_(d)(7) US Agent for Service of Process v1.3 | Attestation Statements | 2025-07-27 | PDF 350.6 KB |
| Agent Authorization Rev 1.0 | Cover Letter(s) | 2025-07-27 | PDF 144.8 KB |
| AgentAuthorizationRev1.0 | Cover Letter(s) | 2025-07-27 | PDF 144.8 KB |
| FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 2025-07-27 | PDF 123.2 KB |
| FCC Short & Long Term Confidentiality Request Rev4.1 ULCC52 497 8562925 | Cover Letter(s) | 2025-07-27 | PDF 123.2 KB |
| Model Difference Declaration | Cover Letter(s) | 2025-07-27 | PDF 121 KB |
| Modeldifferencestatement | Cover Letter(s) | 2025-07-27 | PDF 121 KB |
| MPE | RF Exposure Info | 2025-07-27 | PDF 561 KB |
| MPE | RF Exposure Info | 2025-07-27 | PDF 1.2 MB |
| Block Diagram Metadata only | Block Diagram | PDF 690.5 KB | |
| Block diagram Metadata only | Block Diagram | PDF 690.5 KB | |
| SCH Metadata only | Schematics | PDF 3.1 MB | |
| Operation Description Metadata only | Operational Description | PDF 308.7 KB |
Application Information
| Application ID | gWT0FIaiwKDRLtteaRbMKA== |
|---|---|
| Final Action Date | 2025-07-27 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0033393505 |
| Model | POWERMAX1800 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Portable Power Station |
| Responsible Party | xiuying Zou, zxy@163.com |
| Technical Contact | Shenzhen Doke Communication Co.,Ltd, zxy@163.com |
| Test Firm | Neil Wan, KSIGN (Guangdong) Testing Co., Ltd., info@gdksign.cn |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| gWT0FIaiwKDRLtteaRbMKA== | 2025-07-27 | Original Equipment |
| ajAAF2JHWJdX7I4znzwnMw== | 2025-07-27 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application gWT0FIaiwKDRLtteaRbMKA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 07/27/2025 Application Dated: 07/27/2025 |
| Shenzhen Doke Communication Co.,Ltd |
| 1301-1302,13th Floor, Block B, WeiDongLong Busines |
| s Building, Meilong Road 2113, Longhua District, |
| ShenZhen, China |
| Attention: xiuying Zou , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A98M-POWERMAX1800 |
| Name of Grantee: | Shenzhen Doke Communication Co.,Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Portable Power Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.03954 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.00507 |
| Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application ajAAF2JHWJdX7I4znzwnMw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 07/27/2025 Application Dated: 07/27/2025 |
| Shenzhen Doke Communication Co.,Ltd |
| 1301-1302,13th Floor, Block B, WeiDongLong Busines |
| s Building, Meilong Road 2113, Longhua District, |
| ShenZhen, China |
| Attention: xiuying Zou , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2A98M-POWERMAX1800 |
| Name of Grantee: | Shenzhen Doke Communication Co.,Ltd |
| Equipment Class: | Part 15 Low Power Transmitter Below 1705 kHz |
| Notes: | Portable Power Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 0.115 - 0.205 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |