FCC ID 2A9DL-WIFICARD

Scanology LinkCard

by SCANTECH (HANGZHOU) CO., LTD

Grantee Code: 2A9DL   Product Code: WIFICARD
Latest application date: 2026-03-13

FCC ID Device Details

FCC ID2A9DL-WIFICARD
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A9DL
Product CodeWIFICARD
Applicant BusinessSCANTECH (HANGZHOU) CO., LTD 🇨🇳
Equipment ClassScanology LinkCard
Test FirmGuangdong Global Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2026-03-13
2412-2462 MHzOriginal Equipment2026-03-13

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2026-03-13PDF 629.3 KB
Internal PhotosInternal Photos2026-03-13PDF 1 MB
External PhotosExternal Photos2026-03-13PDF 942.5 KB
ID Label/Location InfoID Label/Location Info2026-03-13PDF 137.6 KB
Test Setup Photos 1Test Setup Photos2026-03-13PDF 436 KB
Test Setup Photos 2Test Setup Photos2026-03-13PDF 704.4 KB
ANT Test ReportTest Report2026-03-13PDF 344.2 KB
Test Report 1Test Report2026-03-13PDF 4.3 MB
Test Report 1Test Report2026-03-13PDF 5.6 MB
Test Report 2Test Report2026-03-13PDF 5 MB
Test Report 2Test Report2026-03-13PDF 4.3 MB
Test Report 3Test Report2026-03-13PDF 3.9 MB
Test Report 3Test Report2026-03-13PDF 4.7 MB
Test Report 4Test Report2026-03-13PDF 5 MB
Test Report 4Test Report2026-03-13PDF 1.4 MB
Test Report 5Test Report2026-03-13PDF 4.7 MB
Test Report 6Test Report2026-03-13PDF 4.6 MB
Test Report 7Test Report2026-03-13PDF 2.8 MB
Test Report 8Test Report2026-03-13PDF 2.1 MB
Attestation StatementsAttestation Statements2026-03-13PDF 269.8 KB
US agentAttestation Statements2026-03-13PDF 86.9 KB
Agent AuthorizationCover Letter(s)2026-03-13PDF 2.8 MB
Long term Confidentiality LetterCover Letter(s)2026-03-13PDF 2.5 MB
Model DifferenceCover Letter(s)2026-03-13PDF 2.9 MB
RF Exposure Info 1RF Exposure Info2026-03-13PDF 2.8 MB
RF Exposure Info 2RF Exposure Info2026-03-13PDF 2 MB
Block Diagram Metadata onlyBlock DiagramPDF 360.4 KB
Schematics Metadata onlySchematicsPDF 229.2 KB
Operational Description Metadata onlyOperational DescriptionPDF 106.1 KB
Software Security Metadata onlySDR Software/Security Info.PDF 219.5 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 195.1 KB

Application Information

Application IDTK/JhWVujYGlEdm0BrTqTA==
Final Action Date2026-03-13
Application PurposeOriginal Equipment
Applicant FRN0033091216
ModelWIFICARD
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionScanology LinkCard
Responsible PartyQihang. Zhou, 854956793@qq.com , 13538218145
Technical ContactShawn Wen, Guangdong Global Testing Technology Co., Ltd., qs04@gtggroup.com , 86 769 8507 5888
Non-Technical ContactMichael Chan, Global Product Services and Consultation LLC, cschanm@gmail.com , +1 626 366 4358
Test FirmShawn Wen, Guangdong Global Testing Technology Co., Ltd., qs04@gtggroup.com , 86-769-8507-5888
TCB Emailtcb@metlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
TK/JhWVujYGlEdm0BrTqTA==2026-03-13Original Equipment
4j5IQB5Tl23tHnXt46VvcQ==2026-03-13Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5180-5240 MHz0.04615ECC MO
5260-5320 MHz0.052515ECC MO ND
5500-5700 MHz0.052615ECC MO ND
5745-5825 MHz0.044515ECC MO
2412-2462 MHz0.040115CCC MO

Grants

TCB Grant - Application TK/JhWVujYGlEdm0BrTqTA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc.
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 03/13/2026

Application Dated: 03/13/2026
SCANTECH (HANGZHOU) CO., LTD
Room 102, Unit 1,Building 12, No 998,
West Wenyi Road, Wuchang Street,
Yuhang District,Hangzhou, Zhejiang,,
China
 
Attention: Qihang. Zhou , manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9DL-WIFICARD
Name of Grantee:  SCANTECH (HANGZHOU) CO., LTD
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Scanology LinkCard
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.046  
CC MO ND 15E 5260.0  -  5320.0 0.0525  
CC MO ND 15E 5500.0  -  5700.0 0.0526  
CC MO 15E 5745.0  -  5825.0 0.0445  

Output power listed is conducted. The device supports 20MHz, 40MHz and 80MHz bandwidths. Highest reported SAR for Body-worn accessory is 1.25W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application 4j5IQB5Tl23tHnXt46VvcQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc.
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 03/13/2026

Application Dated: 03/13/2026
SCANTECH (HANGZHOU) CO., LTD
Room 102, Unit 1,Building 12, No 998,
West Wenyi Road, Wuchang Street,
Yuhang District,Hangzhou, Zhejiang,,
China
 
Attention: Qihang. Zhou , manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9DL-WIFICARD
Name of Grantee:  SCANTECH (HANGZHOU) CO., LTD
Equipment Class: Digital Transmission System
Notes: Scanology LinkCard
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.0401  

Output power listed is conducted. The device supports 20MHz and 40MHz bandwidths. Highest reported SAR for Body-worn accessory is 1.18W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.