1500011824 Digital Lock RF Exposure Info RF exposure Mobile Technologies .

Mobile Technologies . Digital Lock

Page 1 of 1500011824 Digital Lock RF Exposure Info RF exposure Mobile Technologies .

Report Number: 60.790.18.051.01R02
8 Appendix A - General Product Information
Radiofrequency radiation exposure evaluation
This exposure evaluation is intended for FCC ID: 2AA2X-1500011824.
According to KDB 447498 D01v06 section 4.3.1, For frequencies between 100 MHz to 6GHz
and test separation distances 50 mm, the Numeric threshold is determined as:
Step a)
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]
· [ f(GHz)] 3.0 for 1-g SAR
>> The fundamental frequency of the EUT is 2405-2480MHz,
the test separation distance is 50mm.
(Manufacturer specified the separation distance is: 20mm)
Step a)
>> Numeric threshold (2405MHz), mW / 20mm * 2.402GHz
Numeric threshold (2405MHz) 38.713mW
3.0
>> Numeric threshold (2445MHz), mW / 20mm * 2.440GHz
Numeric threshold (2445MHz) 38.411mW
3.0
>> Numeric threshold (2480MHz), mW / 20mm * 2.480GHz
Numeric threshold (2480MHz) 38.100mW
3.0
>> The power of EUT measured (2405MHz) is: 2.03dBm = 1.596mW
The power of EUT measured (2445MHz) is: 2.04dBm = 1.600mW
The power of EUT measured (2480MHz) is: 2.34dBm = 1.714mW
Which is smaller than the Numeric threshold.
Therefore, the device is exempt from stand-alone SAR test requirements.
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 34 of 35
Download: 1500011824 Digital Lock RF Exposure Info RF exposure Mobile Technologies .
Mirror Download [FCC.gov]1500011824 Digital Lock RF Exposure Info RF exposure Mobile Technologies .
Document ID4202543
Application IDrBr2PavE4VNN3no5hl8sHw==
Document DescriptionRF exposure
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize1.42kB (17716 bits)
Date Submitted2019-03-15 00:00:00
Date Available2019-03-15 00:00:00
Creation Date2019-03-12 14:39:43
Producing SoftwarePDF-XChange 3.60.0106 (Windows)
Document Lastmod2019-03-13 14:34:34
Document TitleRF exposure

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2019:03:12 14:39:43+08:00
Modify Date                     : 2019:03:13 14:34:34+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2019:03:13 14:34:34+08:00
Producer                        : PDF-XChange 3.60.0106 (Windows)
Format                          : application/pdf
Document ID                     : uuid:557f8431-a296-4670-9854-1d6e1b3394c1
Instance ID                     : uuid:854887ff-b634-48e4-a8ce-29fdf5176066
Page Count                      : 1