1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.

Mobile Technologies Inc. Digital Lock

Page 1 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 2 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 3 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 4 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 5 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 6 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 7 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 8 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 9 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 10 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 11 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 12 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 13 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 14 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 15 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 16 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Page 17 of 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.

Report Number: 60.790.18.051.01R01
FCC - TEST REPORT
Report Number
60.790.18.051.01R01
Model
Door Lock, Glass Lock, Plunger Lock
Product Type
Digital Lock
Applicant
Mobile Technologies Inc.
Address
1050 NE 67th Ave, Hillsboro, OR 97124
Production Facility
PS Gmbh
Address
Melisau 1255, Autria, 6863 Egg.
Test Result
Positive
Total pages
including
Appendices
Date of Issue
January 15, 2019
Negative
17
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the
principles outlined in ISO 17025.
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions.
Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this
model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities
in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and
Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports.
This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall
not be reproduced except in full without our written approval
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 1 of 17
Report Number: 60.790.18.051.01R01
1 Table of Contents
1 Table of Contents............................................................................................................ 2
2 Description of Equipment Under Test ............................................................................. 3
3 Summary of Test Standards ........................................................................................... 4
4 Details about the Test Laboratory ................................................................................... 5
4.1 Test Equipment Site List ................................................................................................... 6
4.2 Measurement System Uncertainty .................................................................................... 7
5 Summary of Test Results ................................................................................................ 8
6 General Remarks ............................................................................................................ 9
7 Test Setups ................................................................................................................... 10
7.1 Radiated test setups 9kHz-30MHz .................................................................................. 10
7.2 Radiated test setups Below 1GHz................................................................................... 10
7.3 Radiated test setups Above 1GHz .................................................................................. 10
7.4 AC Power Line Conducted Emission test setups ............................................................ 11
7.5 Conducted RF test setups............................................................................................... 11
8 Emission Test Results .................................................................................................. 12
8.1 Spurious Radiated Emission ........................................................................................... 12
8.2 6dB & 99% Bandwidth .................................................................................................... 15
9 Appendix A General Product Information ...................................................................... 16
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 2 of 17
Report Number: 60.790.18.051.01R01
2 Description of Equipment Under Test
Description of the Equipment Under Test
Product:
Digital Lock
Model no.:
Door Lock, Glass Lock, Plunger Lock
FCC ID:
2AA2X-1500011824
Rating:
3V DC (CR 123A battery)
Frequency:
125kHz (Tx and Rx)
Modulation:
AM
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 3 of 17
Report Number: 60.790.18.051.01R01
3 Summary of Test Standards
Test Standards
FCC Part 15 Subpart C 10-1-17 Edition
Federal Communications Commission, PART 15 — Radio Frequency Devices,
Subpart C — Unintentional Radiators
All the tests were performed using the procedures from ANSI C63.4(2014) and ANSI C63.10
(2013).
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 4 of 17
Report Number: 60.790.18.051.01R01
4 Details about the Test Laboratory
Site 1
Company name:
TÜV SÜD Hong Kong Ltd.
3/F, West Wing, Lakeside 2,
10 Science Park West Avenue,
Science Park, Shatin, Hong Kong
Site 2
Company name:
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13 Zhiheng Wisdomland Business Park,
Nantou Checkpoint Road 2,
Shenzhen 518052, P.R.China
FCC Registration Number: 514049
Emission Tests
Test Item
Test Site
FCC Part 15 Subpart C
FCC Title 47 Part 15.205, 15.209 Spurious Radiated Emission
FCC Title 47 Part 15.207 Conduct Emission
FCC Title 47 Part 15.215 20dB Bandwidth
Site 2
NA
Site 2
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 5 of 17
Report Number: 60.790.18.051.01R01
4.1 Test Equipment Site List
Radiated emission Test – Site 2
DESCRIPTION
EMI Test Receiver
Loop Antenna
Trilog Super Broadband Test
Antenna
Horn Antenna
Pre-amplifier
Signal Generator
Attenuator
3m Semi-anechoic chamber
Test software
MANUFACTURER
Rohde & Schwarz
Rohde & Schwarz
MODEL NO.
ESR 26
HFH2-Z2
SERIAL NO.
101269
100398
CAL. DUE DATE
2019-7-6
2019-7-6
Schwarzbeck
VULB 9163
707
2019-6-28
Rohde & Schwarz
HF907
102294
2019-6-28
Rohde & Schwarz
Rohde & Schwarz
Agilent
TDK
Rohde & Schwarz
SCU 18
SMY01
8491A
9X6X6
EMC32
102230
839369/005
MY39264334
---Version 9.15.00
2019-7-6
2019-7-6
2019-7-6
2020-7-7
N/A
MODEL NO.
ESR 3
ENV4200
ENV432
ENV216
ENY81
ENY81-CA6
TK9420(VT94
20)
EZ-17
TS2-26-3
EMC32
SERIAL NO.
101782
100249
101318
100326
100177
101664
CAL. DUE DATE
2019-7-6
2019-7-6
2019-7-6
2019-7-6
2019-7-6
2019-7-6
9420-584
2019-6-30
100816
080928189
Version9.15.00
2019-6-30
2019-7-6
N/A
MODEL NO.
FSV40
SERIAL NO.
101030
CAL. DUE DATE
2019-7-6
Conducted Emission Test – Site 2
DESCRIPTION
MANUFACTURER
EMI Test Receiver
Rohde & Schwarz
LISN
Rohde & Schwarz
LISN
Rohde & Schwarz
LISN
Rohde & Schwarz
ISN
Rohde & Schwarz
ISN
Rohde & Schwarz
High Voltage Probe
Rohde & Schwarz
RF Current Probe
Attenuator
Test software
Rohde & Schwarz
Shanghai Huaxiang
Rohde & Schwarz
20dB Bandwidth– Site 2
DESCRIPTION
Signal Analyzer
MANUFACTURER
Rohde & Schwarz
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 6 of 17
Report Number: 60.790.18.051.01R01
4.2 Measurement System Uncertainty
Measurement System Uncertainty Emissions
System Measurement Uncertainty
Items
Extended Uncertainty
Uncertainty for Radiated Emission in 3m chamber
9kHz-30MHz
Uncertainty for Radiated Emission in 3m chamber
30MHz-1000MHz
Uncertainty for Radiated Emission in 3m chamber
1000MHz-18000MHz
Uncertainty for Conducted Emission at AC Power Line
150kHz-30MHz
Uncertainty for frequency test
4.46dB
Horizontal: 4.91dB;
Vertical: 4.89dB;
Horizontal: 4.80dB;
Vertical: 4.79dB;
3.21dB
0.6×10-7
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 7 of 17
Report Number: 60.790.18.051.01R01
5 Summary of Test Results
Emission Tests
FCC Part 15 Subpart C
Test Condition
Pages
FCC Title 47 Part 15.205, 15.209 Spurious Radiated Emission
FCC Title 47 Part 15.207 Conduct Emission (1)
FCC Title 47 Part 15.215 20dB Bandwidth
Remark:
(1) Conducted Emission testing is not applicable for battery operating device.
12-14
NIL
16
Test Result
Pass Fail N/A
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 8 of 17
Report Number: 60.790.18.051.01R01
6 General Remarks
Remarks
Client informs that the Glass Lock and Plunger Lock have the same technical construction including
circuit diagram and electrical construction, with Digital Lock, Door Lock. The difference lies only in
the outlook/color, PCB Layout, components, component layout and mechanical construction of the
different models. (Client’s conformation letter shown at appendix A)
EMC tests were performed on all three models, only the Door Lock’s data was shown on this report,
which is the worst case.
This submittal(s) (test report) is intended for FCC ID: 2AA2X-1500011824, complies with Section
15.205, 15.207, 15.209, 15.215 of the FCC Part 15, Subpart C rules.
The TX and RX range is 125kHz.
SUMMARY:
- All tests according to the regulations cited on page 8 were
 - Performed
 - Not Performed
- The Equipment Under Test
 - Fulfills the general approval requirements.
 - Does not fulfill the general approval requirements.
Sample Received Date:
October 10, 2018
Testing Start Date:
October 16, 2018
Testing End Date:
January 7, 2019
Reviewed by:
Prepared by:
______________________________________
Hosea CHAN
EMC Project Engineer
____________________________________
Eric LI
EMC Senior Project Engineer
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 9 of 17
Report Number: 60.790.18.051.01R01
7 Test Setups
7.1 Radiated test setups 9kHz-30MHz
7.2 Radiated test setups Below 1GHz
7.3 Radiated test setups Above 1GHz
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 10 of 17
Report Number: 60.790.18.051.01R01
7.4 AC Power Line Conducted Emission test setups
7.5 Conducted RF test setups
Spectrum analyzer
EUT
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 11 of 17
Report Number: 60.790.18.051.01R01
8 Emission Test Results
8.1 Spurious Radiated Emission
EUT:
Op Condition:
Test Specification:
Comment:
Remark:
Door Lock
Operated, TX Mode
FCC15.205, 15.209
3V DC
9kHz to 30MHz
Test Result
Passed
Not Passed
Frequency
MHz
Result
dBµV/m
Limit
dBµV/m
Margin
dB
Detector
PK/QP/AV
0.125
0.250
0.468
49.52
48.23
51.23
105.67
99.65
94.20
-56.15
-51.42
-42.97
Peak
Peak
Peak
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 12 of 17
Report Number: 60.790.18.051.01R01
Spurious Radiated Emission
EUT:
Op Condition:
Test Specification:
Comment:
Remark:
Door Lock
Operated, TX Mode
FCC15.205, 15.209
3V DC
30MHz to 1GHz, Antenna: Horizontal
Test Result
Passed
Not Passed
70
Level in dBµV/m
60
50
40
30
20
10
30M
50 60
80 100M
200
300
400 500
800 1G
F re q u e n c y in H z
Frequency
(MHz)
46.247500
54.250000
99.597500
124.271875
164.587500
193.748125
MaxPeak
(dBµV/m)
17.30
18.81
16.49
16.78
16.21
19.66
Limit
(dBµV/m)
40.00
40.00
43.50
43.50
43.50
43.50
Margin
(dB)
-22.70
-21.19
-27.01
-26.72
-27.29
-23.84
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 13 of 17
Report Number: 60.790.18.051.01R01
Spurious Radiated Emission
EUT:
Op Condition:
Test Specification:
Comment:
Remark:
Door Lock
Operated, TX Mode
FCC15.205, 15.209
3V DC
30MHz to 1GHz, Antenna: Vertical
Test Result
Passed
Not Passed
70
Level in dBµV/m
60
50
40
30
20
10
30M
50 60
80 100M
200
300
400 500
800 1G
F re q u e n c y in H z
Frequency
(MHz)
30.424375
34.365000
46.247500
55.098750
96.141875
118.936875
MaxPeak
(dBµV/m)
21.71
19.62
19.82
21.67
17.50
17.18
Limit
(dBµV/m)
40.00
40.00
40.00
40.00
43.50
43.50
Margin
(dB)
-18.29
-20.38
-20.18
-18.33
-26.00
-26.32
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 14 of 17
Report Number: 60.790.18.051.01R01
8.2 6dB & 99% Bandwidth
EUT:
Op Condition:
Test Specification:
Comment:
Door Lock
Operated, TX Mode
FCC15.215, 20dB Bandwidth
3V DC
Bandwidth
20dB bandwidth
99% bandwidth
Test Result
Passed
Not Passed
Measured Value
6.2 kHz
13.1 kHz
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 15 of 17
Report Number: 60.790.18.051.01R01
9 Ap p en dix A G en er al Pr odu ct I nfo rma tion
Radiofrequency radiation exposure evaluation
According to KDB 447498 D01v06 section 4.3.1, For frequencies below 100 MHz and test
separation distances ≤ 50 mm, the Numeric threshold is determined as:
Step a)
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR
Step b)
{[Power allowed at numeric threshold for 50mm in step a)] + [(test separation distance – 50mm) · (f(MHz)/150)]} mW
Step c) 1)
For test separation distances > 50mm and < 200mm, the power threshold at the corresponding test separation distance at
100MHz in step b) is multiplied by [1 + log(100/f(MHz))]
Step c) 2)
For test separation distances ≤ 50mm, the power threshold determined by the equation in c) 1) for 50mm and 100MHz is
multiplied by ½.
>> The fundamental frequency of the EUT is 125kHz, the test separation distance is ≤ 50mm.
(Manufacturer specified the separation distance is: 20mm)
Step a)
>> Numeric threshold, mW / 50mm * √0.1GHz ≤ 3.0
Numeric threshold ≤ 474.3mW
Step b)
>> Numeric threshold ≤ 474.3mW + (50mm-50mm * 100MHz/150)
Numeric threshold ≤ 474.3mW
Step c) 1) & c) 2)
>> Numeric threshold ≤ 474.3mW * [1 + log 100/100MHz] * ½
Numeric threshold ≤ 237.15mW
>> The transmitter strength of EUT measured is: 49.52 dBµV/m
The power calculated is 0.000001786487mW
Which is smaller than the Numeric threshold.
Therefore, the device is exempt from stand-alone SAR test requirements.
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 16 of 17
Report Number: 60.790.18.051.01R01
General Product Information
Declaration letter of model difference
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
518052 Shenzhen, CHINA
Page 17 of 17
Download: 1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Mirror Download [FCC.gov]1500011824 Digital Lock Test Report EMC EMISSION - Mobile Technologies Inc.
Document ID4202488
Application IDU7UbHVWB1dgLmEbT5l2c1w==
Document DescriptionTest report-DCD
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize67.77kB (847110 bits)
Date Submitted2019-03-15 00:00:00
Date Available2019-03-15 00:00:00
Creation Date2019-03-07 17:21:40
Producing SoftwareMicrosoft? Word 2016; modified using iText? 5.5.10 ?2000-2015 iText Group NV (AGPL-version)
Document Lastmod2019-03-07 17:23:29
Document TitleEMC EMISSION - TEST REPORT
Document CreatorMicrosoft® Word 2016
Document Author: asd

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
Author                          : asd
Create Date                     : 2019:03:07 17:21:40+08:00
Creator                         : Microsoft® Word 2016
Keywords                        : 68.740.14.038.01
Modify Date                     : 2019:03:07 17:23:29+08:00
Producer                        : Microsoft? Word 2016; modified using iText? 5.5.10 ?2000-2015 iText Group NV (AGPL-version)
Title                           : EMC EMISSION - TEST REPORT
Has XFA                         : No
Language                        : en-US
Tagged PDF                      : Yes
Page Count                      : 17
Signer Contact Info             : 
Signing Location                : 中国
Signing Date                    : 2019:03:07 17:23:28+08:00
Signing Reason                  : 文档加密保护
Modification Permissions        : Fill forms, Create page templates, Sign
PDF Version                     : 1.5